DiR - Moligand™, 10 mM in DMSO , CAS No.100068-60-8

CAS: 100068-60-8 Cat. No.: D1499710 Fórmula: C63H101IN2 Peso molecular: 1013.41 Número EC: 144-876-3 PubChem CID: 74405886
Disponible para pedir
CALIDAD & PUREZA Moligand™ ? Moligand™ — Aladdin's line of ligands and bioactive small molecules. Use for receptor, pathway, and binding studies needing defined small-molecule tools. 10 mM in DMSO
Storage
Protected from light,Argon charged,Store at -80°C
Shipped In
Dry ice packs + Cold packs
★
Talla
Alemania (EU)
USA*
Precio
Cantidad
1ml
D1499710-1ml
Fabricado bajo pedido · 8–12 semanas
38,09€
Enter a quantity for the sizes you want to add.

Descripción general

DiR is a long-chain carbocyanine dye. Carbocyanine dyes are widely used as Di to label cells, organelles, liposomes, viruses and lipoproteins.

Especificaciones

Especificaciones y pureza
Moligand™, 10 mM in DMSO
Condiciones de almacenamiento de almacenamiento
Protected from light,Argon charged,Store at -80°C
Enviado en
Dry ice packs + Cold packs
Este producto requiere envío en cadena de frío. Los servicios terrestres y otros servicios económicos no están disponibles.
Grado
Moligand™
Nombres e identificadores
Isómeros SMILES
CCCCCCCCCCCCCCCCCCN1C2=CC=CC=C2C(C1=CC=CC=CC=CC3=[N+](C4=CC=CC=C4C3(C)C)CCCCCCCCCCCCCCCCCC)(C)C.[I-]
PubChem CID
74405886
Peso molecular
1013.41

Datos avanzados

Certificados (CoA, COO, BSE/TSE y tabla de análisis)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate TypeFechaArticulo
J2616774J2616774Certificate of AnalysisOct 20, 2026 D1499710
Preguntas frecuentes y artículos
Citations of This Product
Calculadoras de soluciones
Reseñas

Reseñas de cliente

Application Protocols

The following protocols are literature‑based best practices for DiR‑type dyes and are provided as general guidance (not product‑specific). Optimize for your system.

  1. Stock solution and aliquoting
  • Prepare 2–5 mM stock in anhydrous DMSO. Vortex to clarify; brief bath sonication if needed. Dispense into amber, argon‑blanketed micro‑aliquots (e.g., 10–50 μL). Store at −80 °C. Avoid repeated freeze–thaw; thaw on ice, use once, discard remainder.
  1. Cell membrane staining (suspension cells)
  • Pellet cells and resuspend at 1–5 × 10^6 cells/mL in serum‑free medium or HBSS.
  • Add dye to 1–3 μM final (DMSO ≤0.1% v/v). Mix gently and incubate 10–20 min at 37 °C protected from light.
  • Quench/stop by adding equal volume of complete medium; wash 2–3× with warm buffer. Analyze promptly by NIR‑capable cytometer or microscope.
  1. Liposome labeling (post‑insertion method)
  • Warm pre‑formed liposomes (e.g., 100 nm, PBS) to 37–45 °C.
  • Add dye from DMSO stock to reach 0.5–5 nmol dye per μmol total lipid; incubate 15–60 min with gentle mixing in the dark.
  • Remove free dye by gel filtration (Sephadex G‑50/G‑75), dialysis, or spin columns.
  1. Polymer nanoparticle loading (nanoprecipitation)
  • Dissolve polymer and dye in acetonitrile or acetone; rapidly inject into stirred aqueous phase containing 0.01–0.1% w/v stabilizer.
  • Stir to allow solvent exchange and particle formation; remove organic solvent under reduced pressure; wash particles to remove free dye.

Instrument tips

  • Excitation ~740–750 nm; emission collection ~770–820 nm (exact settings depend on instrument and matrix). Use NIR filters and minimize photobleaching by short exposures.
Biological Roles

DiR is not a natural metabolite or biomolecule; it is an exogenous lipophilic fluorescent probe.

Literature context (not product‑specific claims):

  • Membrane integration: The two C18 chains intercalate into phospholipid bilayers, positioning the polymethine chromophore near the lipid–water interface. This affords persistent membrane labeling with slow desorption.
  • Trafficking readouts: When incorporated into vesicles (e.g., liposomes, exosomes) or hydrophobic nanoparticles, DiR fluorescence in the NIR enables low‑autofluorescence detection in complex biological matrices for research studies (flow cytometry, microscopy, whole‑organ imaging systems).
  • Photophysics in biomembranes: Dye displays environment‑sensitive spectral shifts; membrane phase (gel vs liquid‑ordered/disordered), cholesterol content, and local packing can modulate λmax, quantum yield, and anisotropy. Aggregation within membranes (H/J) can quench or shift emission.
  • Protein interactions: Limited direct binding to proteins is expected compared to water‑soluble cyanines; serum proteins can still sequester dye if not well embedded in membranes, potentially altering biodistribution in model systems.

Important use note (from Product Data):

  • For research use only. No medical or clinical use is intended or implied.

If specific biological performance metrics (e.g., quantum yield in specific lipid compositions) are required for this lot, please consult the CoA or perform application‑specific validation.

Buffer Applications

This product is a lipophilic fluorescent dye and is not used as a buffering agent. Therefore, classical buffer system formulation (pKa/pH control, ionic strength) is not applicable.

Practical notes for use in aqueous buffers (general/literature guidance):

  • Delivery to buffers: Introduce from a DMSO or ethanol stock into buffered solutions immediately before use; final organic cosolvent typically kept ≤0.1–0.5% v/v to maintain cell/biomolecule compatibility.
  • Carriers: To prevent precipitation/aggregation, incorporate the dye into lipid carriers (liposomes, vesicles), polymeric micelles, or use low levels of nonionic surfactants (e.g., Tween‑80 at 0.02–0.05%) as warranted by the application.
  • pH effects: Spectral properties of carbocyanines are relatively insensitive to physiological pH; however, extreme pH or high ionic strength can promote aggregation or degradation.

For actual buffer recipes and pH ranges, refer instead to standard biological buffers (PBS, HEPES, Tris) appropriate to your biological system; the dye itself does not define buffer capacity.

Green Alternatives

Environmental and safety considerations for NIR lipophilic dyes often revolve around solvent use and dye loadings rather than the dye core itself. Below are literature‑based alternatives and tradeoffs (not product‑specific recommendations):

  • Solvent choices:

    • Replace DMF/chlorinated solvents with DMSO, ethanol, or isopropanol where feasible. DMSO and ethanol are greener and often provide adequate solubility and spectral performance.
    • Use aqueous dispersion strategies (e.g., pre‑loading into liposomes or polymeric micelles) to minimize organic cosolvent in working solutions.
  • Alternative tracers/approaches (comparison is contextual; select based on matrix and detection needs):

    • Indocyanine green (ICG): Water‑soluble FDA‑approved dye for clinical imaging; greener in terms of solvent handling but less hydrophobic anchoring—can leach from hydrophobic matrices.
    • DiD/DiI (shorter‑wavelength carbocyanines): Similar lipophilicity (DiI) or somewhat less (DiD); may reduce light exposure risk if using lower‑energy excitation; however, they emit outside deep‑NIR window.
    • Encapsulated fluorescent nanoparticles (e.g., silica‑coated, polymer dots): Reduced dye leaching and improved photostability; tradeoff is added material complexity and potential persistence in the environment.
  • Process improvements:

    • Prepare concentrated stocks to minimize overall solvent volume.
    • Employ closed, amberized systems to reduce waste due to photodegradation.
    • Validate lowest effective dye loading to achieve S/N targets, reducing environmental load.

Note: The intrinsic composition of this specific SKU and any stabilizers are not specified; consult CoA/SDS for detailed environmental and hazard information.

Pharmaceutical Uses

No therapeutic or clinical claims are made for this product. Research use only (per Product Data).

Formulation‑science context (general/literature; not product‑specific):

  • Tracer in formulation development: DiR‑type lipophilic dyes are commonly used as NIR reporters to study preparation, stability, and distribution of lipid‑based systems (liposomes, solid lipid nanoparticles, nanoemulsions) and hydrophobic polymeric carriers. They enable sensitive tracking without altering carrier composition significantly at low loadings.
  • Process analytics: NIR fluorescence facilitates rapid in‑process control (IPC) of dye distribution uniformity, leakage studies, and stress stability (heat, light, surfactant exposure) of carriers.
  • Excipient compatibility: Generally compatible with phospholipids, cholesterol, PEGylated lipids, and many hydrophobic polymers. Validate for leaching and quenching with surfactants and proteins present in the intended matrix.
  • Regulatory considerations: When used as an analytical tracer in nonclinical development, selection is based on detectability and minimal impact on the system; the dye itself is not intended as an API or excipient in a drug product. Any translational use would require suitability assessments beyond the scope of this listing.

If pharmacopeial status or impurity limits are required: Not specified for this item; refer to CoA/Spec Sheet and SDS, and conduct application‑specific risk assessments.

Physical Properties

Item-specific physicochemical specifications provided: none.

  • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.

General/literature properties for DiR‑type carbocyanine dyes (for context; not specifications for this item):

  • Physical state: Typically a dark solid (deep blue/green to black hue) as a salt (often iodide). Strongly lipophilic due to C18 chains.
  • Solubility profile: Sparingly soluble in water; readily soluble in polar aprotic organic solvents such as DMSO and DMF; soluble in ethanol and other alcohols to a lesser extent; partitions efficiently into lipid membranes, micelles, and hydrophobic polymer matrices.
  • Spectral characteristics (NIR; typical): absorption (λmax) ~740–750 nm; emission (λem) ~770–800 nm; high molar absorptivity on the order of 2–3 × 10^5 M^-1 cm^-1; broad Stokes shift in the NIR. Exact maxima depend on solvent, microenvironment, and isomer ratio.
  • LogP (qualitative): Very high (strong bilayer affinity) owing to two C18 chains; effective membrane insertion with minimal flip‑flop off‑rate in gel/fluid bilayers.
  • Stability considerations: Photosensitive; gradual photobleaching and possible E/Z isomerization under light; may aggregate (H/J) in aqueous buffers without adequate surfactant/lipid context, altering spectra.

If precise numeric values (mp, bp, density, refractive index, UV cutoff, water content, etc.) are required for this specific lot, please consult the CoA/Spec Sheet.

Quality and Grades

Item-specific grade: Moligand™ (as listed in Product Data).

What this generally implies (program description; not a guarantee of any unstated specification):

  • Moligand™ products are positioned for research applications requiring high-performance small molecules, probes, and ligands. For dyes, this typically emphasizes high chemical purity and performance in labeling/imaging contexts, low adventitious fluorescence contaminants, and consistent lot-to-lot spectral properties.
  • No explicit purity percentage, stabilizer content, or analytical limits (e.g., metals, water, peroxides) are provided in the Product Data. Therefore: Not specified for this item; refer to CoA/Spec Sheet.

Analytical characterization you may expect to see on the CoA/Spec Sheet (examples; consult actual CoA for this SKU):

  • Identity: NMR, HRMS/ESI, and/or HPLC‑PDA chromatogram with NIR trace to assess dye integrity and isomer distribution.
  • Purity: HPLC (UV/NIR) area percent and residual solvents.
  • Performance checks: Optional absorbance/fluorescence benchmarks in defined solvents (e.g., DMSO, ethanol) to confirm λmax within expected windows.

Practical implications for users:

  • For quantitative imaging and reproducibility, verify extinction coefficient and emission maxima in your exact solvent/matrix on receipt.
  • If your application is highly sensitive (e.g., in vivo optical instrument calibration, nanoparticle QC), request batch CoA/SDS for exact details before use.

Regulatory status:

  • Research use only (per Product Data). Not for diagnostic or therapeutic use.
Reaction and Applications

This product is primarily used as a performance dye/tracer rather than a synthetic reagent.

Literature applications (for DiR‑type carbocyanines; not product‑specific claims):

  • Lipid membrane labeling: The two C18 chains anchor the chromophore into lipid bilayers with slow lateral diffusion and minimal desorption, enabling long-term tracking of cell membranes and vesicles.
  • Nanocarrier tracking: Noncovalent loading into liposomes, polymersomes, micelles, and hydrophobic nanoparticle cores for NIR fluorescence tracking, distribution studies, and process development.
  • Materials imaging: Doping of hydrophobic polymers and electrospun fibers for NIR optical characterization and waveguiding/diffusion studies.
  • Spectroscopy/photophysics: Model NIR polymethine for studies of aggregation (H/J), solvatochromism, and excited‑state dynamics; calibration of NIR instruments.

Practical tips (general):

  • Prevent aggregation: Use high-quality anhydrous DMSO stocks; dilute with vigorous mixing; maintain low working concentrations (typically nM–μM) to avoid excitonic coupling in aqueous media.
  • Control microenvironment: Spectral maxima and quantum yield depend on solvent polarity, viscosity, and membrane phase; validate under your conditions.
  • Photoprotection: Work under subdued light; employ amberware; minimize light exposure during incubations and imaging.
  • Lot verification: Record absorbance spectrum in your solvent (e.g., DMSO or ethanol); compare λmax and spectral shape with literature ranges to confirm integrity.

No named organic synthesis reactions are typically performed with this dye; it serves as a probe rather than a building block.

Reaction Conditions

Classical organic reaction conditions are not typically applied to this finished dye. Instead, researchers implement formulation/incorporation conditions. Below are literature‑based handling/incorporation conditions (not product‑specific):

  • Stock preparation:

    • Dissolve at 1–5 mM in anhydrous DMSO under low light; vortex and, if needed, briefly sonicate. Filter through 0.22 μm PTFE if particulates persist.
  • Cell membrane labeling (adherent cells):

    • Dilute stock into serum‑free medium to 1–5 μM final, DMSO ≤0.1% v/v. Incubate 5–20 min at 37 °C in the dark. Rinse 2–3× with warm buffer/medium. Optimize concentration/time to balance signal and background.
  • Liposome loading (thin‑film hydration):

    • Co‑dissolve lipids and dye in chloroform/methanol (or ethanol for greener approach); cast a thin film; remove solvent; hydrate with buffer at 40–60 °C with agitation; size by extrusion. Typical dye:lipid molar ratios 1:5,000 to 1:500 depending on brightness and quenching tolerance.
  • Polymeric nanoparticle loading (emulsion/solvent evaporation):

    • Dissolve polymer and dye in a volatile organic solvent (e.g., ethyl acetate or acetone as greener alternatives to CH2Cl2); emulsify into aqueous surfactant; evaporate solvent; wash to remove free dye. Loading levels commonly 0.001–0.1% w/w relative to polymer.
  • Spectroscopy:

    • Record absorbance/fluorescence immediately after dilution to minimize aggregation drift; use quartz cuvettes; protect from light. Expect λmax in the NIR; verify for your matrix.

All parameters above are general literature guidance and should be optimized for your system.

Safety and Handling

Authoritative safety data must be taken from the SDS for this SKU.

Item-specific hazard fields provided: none.

  • Signal word: Not specified for this item; refer to SDS.
  • H-statements: Not specified for this item; refer to SDS.
  • GHS classification/pictograms: Not specified for this item; refer to SDS.

General handling guidance for lipophilic carbocyanine dyes (literature/best practice; not product-specific):

  • PPE: Wear lab coat, nitrile gloves, and splash goggles. Handle powders/solids in a fume hood to avoid dust inhalation.
  • Light sensitivity: Protect from light at all times (amber glassware/foil wrap). Minimize exposure during weighing and solution prep.
  • Incompatibilities: Strong oxidizers may degrade polymethine chromophores; avoid bases/nucleophiles that can attack the polymethine under forcing conditions; avoid prolonged exposure to acids that may promote dye decomposition.
  • Solution handling: Prepare concentrated stocks in dry, anhydrous DMSO or ethanol; filter (0.22 μm PTFE) if needed to remove particulates/aggregates. Use single‑use aliquots to avoid repeated freeze–thaw.
  • Photostability: Use minimal intense illumination during imaging; include anti‑fade strategies where applicable.
  • First aid (overview; follow SDS): Inhalation—move to fresh air. Skin/eye contact—rinse with water for 15 minutes; remove contaminated clothing. Ingestion—rinse mouth; seek medical attention. Provide SDS to medical personnel.
  • Waste: Dispose as organic dye/halide salt waste per institutional and regulatory guidelines. Prevent release to drains.

Storage per Product Data: Store at −80 °C, protected from light, argon charged. Shipments are on dry ice + cold packs.

Solvent Selection

Selection principles for DiR‑type lipophilic carbocyanine dyes (general/literature guidance):

  • Polarity/miscibility:

    • Strongly hydrophobic; practically insoluble in water without carriers.
    • Readily soluble in DMSO and DMF; moderately soluble in ethanol, isopropanol; soluble in chlorinated solvents (e.g., CH2Cl2) if required for materials processing.
    • Efficiently partitions into lipid bilayers, micelles, and hydrophobic polymer matrices.
  • Typical stock solutions (literature best practices):

    • 1–5 mM in anhydrous DMSO (amber vials). For alcohol stocks, 0.1–1 mM to reduce aggregation.
    • For direct membrane staining, dilute DMSO stocks into buffer with serum/albumin kept low to minimize nonspecific binding; final DMSO ≤0.1–0.5% v/v.
  • When to choose which solvent:

    • DMSO: Highest solvating power, minimal aggregation; preferred for master stocks and precise dosing.
    • Ethanol/IPA: Useful for pre‑mixing with lipid solutions or preparing working solutions for cell labeling; lower toxicity than DMF.
    • Aqueous buffers: Use only with carriers—e.g., incorporate with lipids/detergents, or pre‑load into nanoparticles, liposomes, or micelles.
  • Brief comparison (literature):

    • DMSO vs ethanol: DMSO reduces H/J aggregation better; ethanol may be preferable for rapid membrane insertion with minimal cosolvent toxicity in live-cell work.
    • Detergent‑assisted buffers (e.g., 0.02–0.05% Tween‑80): Can help disperse dye but may alter membrane integrity—validate carefully.

Note: Specific solubility numbers and UV cutoff are not specified for this item; refer to CoA/Spec Sheet if required.

Storage and Reconstitution

Item-specific storage and shipping (from Product Data):

  • Storage conditions: Protect from light; argon charged; store at −80 °C.
  • Shipped in: Dry ice packs + cold packs.

General reconstitution guidance (literature/best practice; not a specification):

  • Solvents: Reconstitute in anhydrous DMSO for highest solubility and stability; ethanol can be used for certain applications. Avoid water for primary dissolution due to poor solubility and aggregation.
  • Concentration: Prepare 1–5 mM master stocks. Filter through 0.22 μm PTFE if particulates/aggregates are observed.
  • Aliquoting: Dispense single‑use amber aliquots under inert gas (argon/nitrogen) to minimize oxidative and photolytic degradation.
  • Handling: Thaw aliquots on ice, use immediately, and avoid repeated freeze–thaw cycles. Keep solutions shielded from light at all times.
  • Working solutions: Prepare immediately before use by diluting into compatible media (buffer, culture medium, lipid dispersions). Limit final DMSO/EtOH content (commonly ≤0.1–0.5% v/v) to maintain biological compatibility.

Stability notes (general):

  • Photosensitive; prolonged light exposure leads to bleaching and E/Z isomerization.
  • Elevated temperatures accelerate degradation; store as directed above. For short‑term storage of working stocks, keep at 2–8 °C, protected from light, and use within the same day.

Any item‑specific reconstitution instructions, stabilizers, or concentration limits not listed here are: Not specified for this item; refer to CoA/Spec Sheet.

Structure and Identity

Overview: DiR is widely known in the literature as a lipophilic near‑infrared (NIR) carbocyanine dye used as a membrane tracer and for labeling hydrophobic nanocarriers.

Item-specific identifiers (from Product Data):

  • SKU: D1499710
  • Product name: DiR
  • CAS: 100068-60-8
  • PubChem CID: 74405886
  • InChIKey: Not specified for this item; refer to CoA/Spec Sheet.
  • SMILES: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.

Structural features (general chemistry knowledge; literature description, not a specification for this item):

  • Dye class: Heptamethine carbocyanine (NIR) bearing two long, saturated C18 alkyl chains (“DiIC18(7)”-type), typically supplied as a quaternary indolinium salt (often iodide or related counterion).
  • Functional groups: Two indolenium headgroups connected by a polymethine (heptamethine) bridge; quaternary ammonium (indolinium) centers confer cationic character; two long alkyl substituents confer strong lipophilicity and membrane affinity.
  • 2D description: Two terminal heteroaromatic indolinium rings at each end of a conjugated chain; each indolinium bears two adjacent methyls (tetramethyl overall across the pair) and one n‑octadecyl substituent. A delocalized polyene connects the heterocycles, responsible for NIR absorption.

Stereochemistry/tautomerism (literature):

  • Polymethine chain is formally polyene; E/Z isomerization around the methine double bonds can occur photochemically/thermally, affecting spectra. No defined stereocenters.

Note: Exact salt form, counterion, and any stabilizers are not specified for this item; consult the CoA/Spec Sheet for definitive identity information.

Synthetic Utility

As supplied, DiR functions as a finished NIR fluorescent probe rather than a synthetic intermediate.

General chemistry perspective (literature; not product‑specific):

  • Reactivity: The polymethine chain of carbocyanines is electron‑rich and can be susceptible to oxidation and nucleophilic attack under harsh conditions; this limits its use in further synthetic elaboration once fully assembled.
  • Quaternary indolinium centers: Permanently cationic; typical DiR lacks pendant reactive handles (e.g., NHS esters, azides), which constrains covalent bioconjugation. Incorporation is usually noncovalent (membrane embedding or encapsulation) rather than covalent coupling.
  • Counterion exchange: Ion pairing can sometimes be modified (e.g., iodide to non‑nucleophilic counterions) to influence solubility and processing, but such changes require careful purification and can alter spectral properties slightly.
  • Materials processing: In polymer science, the dye can be blended into hydrophobic matrices or electrospun with polymers (e.g., PLGA, PMMA) for NIR‑responsive materials—this is a formulation task, not a chemical transformation.

If your goal is to derivatize a cyanine dye covalently (e.g., to add click handles or bioconjugation groups), consider precursor cyanines designed with functional substituents; DiR itself is generally selected for strong bilayer anchoring rather than synthetic flexibility.

Target Specificity

Not applicable. This product is a small‑molecule fluorescent dye and is not an antibody, enzyme, or affinity ligand with defined biological target specificity.

General note (literature): DiR‑type dyes label lipid bilayers and hydrophobic domains non‑selectively by partitioning; any apparent “specificity” arises from the distribution of accessible hydrophobic environments in the experimental system rather than molecular recognition.

No clone, isotype, antigen, or species reactivity information applies.

¿Quieres que te enviemos un mensaje cuando tengamos descuentos disponibles?

Recordármelo más tarde

¡Gracias! Por favor, revisa tu bandeja de entrada de correo electrónico para confirmar.