FPFT-2216 - 10mM in DMSO , CAS No.2367619-87-0

CAS: 2367619-87-0 Cat. No.: F656278 Fórmula: C12H12N4O3S Peso molecular: 292.31
Disponible para pedir
CALIDAD & PUREZA 10mM in DMSO
Storage
Store at -80°C
Shipped In
Dry ice packs + Cold packs
★
Talla
Alemania (EU)
USA*
Precio
Cantidad
1ml
F656278-1ml
Fabricado bajo pedido · 8–12 semanas
573,49€
Enter a quantity for the sizes you want to add.

Descripción general

FPFT-2216, a “molecular glue” compound, degrades phosphodiesterase 6D ( PDE6D ), zinc finger transcription factors Ikaros ( IKZF1 ), Aiolos ( IKZF3 ), and casein kinase 1α ( CK1α ). FPFT-2216 can be used for the research of cancer and inflammatory disease

In Vitro

FPFT-2216 (1 μM; 5 hours) is able to degrade PDE6D, in addition to its known targets IKZF1, IKZF3, and CK1α in MOLT4 cells. FPFT-2216 (1 μM; 0 h, 2 h, 4 h, 6 h, 16 h, 24 h) shows complete degradation of PDE6D within 2 h, and the degradation of PDE6D persists for at least 24 h in MOLT4 cells. FPFT-2216 (0 nM, 1.6 nM, 8 nM, 40 nM, 200 nM, 1 μM; 4 h) exhibits over 50% degradation of PDE6D at a dose of 8 nM, while maximum degradation of PDE6D along with IKZF1, IKZF3, and CK1α at a dose of 200 nM in MOLT4 cells. FPFT-2216 does not impede the growth of KRAS G12C -dependent MIA PaCa-2 cells. FPFT-2216 (10, 20, 40 µM; 14 or 24 h) highly up-regulates the production of IL-2 although it is less potent than that of Pomalidomide in Naive CD4 + T cells. FPFT-2216 (10 µM; 14 or 24 h) degrades IKZF1 and CK-1α among ubiquitin–proteasomal degradative substrates of immunomodulatory drugs (IMiDs) in Naive CD4 + T cells. MCE has not independently confirmed the accuracy of these methods. They are for reference only. Western Blot AnalysisCell Line: MOLT4 cells Concentration: 1 μM Incubation Time: 0 h, 2 h, 4 h, 6 h, 16 h, 24 h Result: Showed complete degradation of PDE6D within 2 h, and the degradation of PDE6D persisted for at least 24 h. Western Blot AnalysisCell Line: MOLT4 cells Concentration: 0 nM, 1.6 nM, 8 nM, 40 nM, 200 nM, 1 μM Incubation Time: 4 h Result: Exhibited over 50% degradation of PDE6D at a dose of 8 nM, while maximum degradation of PDE6D along with IKZF1, IKZF3, and CK1α at a dose of 200 nM.

In Vivo

FPFT-2216 (30 mg/kg; p.o. or i.p.) induces significant degradation of CK-1α, and IKZF1 in CRBN I391V mice. MCE has not independently confirmed the accuracy of these methods. They are for reference only. Animal Model: CRBN I391V miceDosage: 30 mg/kg (solubilized in 0.5% carboxymethylcellulose/sodium and 0.25% Tween 80) Administration: p.o. or i.p. Result: Induced significant degradation of CK-1α, and IKZF1.

IC50& Target:PDE6D CK1α IKZF1 IKZF3

Especificaciones

Especificaciones y pureza
10mM in DMSO
Mecanismos bioquímicos y fisiológicos
FPFT-2216, a “molecular glue” compound, degrades phosphodiesterase 6D ( PDE6D ), zinc finger transcription factors Ikaros ( IKZF1 ), Aiolos ( IKZF3 ), and casein kinase 1α ( CK1α ). FPFT-2216 can be used for the research of cancer and inflammatory disease
Condiciones de almacenamiento de almacenamiento
Store at -80°C
Enviado en
Dry ice packs + Cold packs
Este producto requiere envío en cadena de frío. Los servicios terrestres y otros servicios económicos no están disponibles.
Tipo de acción
INHIBITOR
Nombres e identificadores
Peso molecular
292.31

Datos avanzados

Certificados (CoA, COO, BSE/TSE y tabla de análisis)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Calculadoras de soluciones
Reseñas

Reseñas de cliente

Application Protocols

No tested applications or recommended dilutions are provided in the Product Data for FPFT-2216.

General screening workflow guidance (not item-specific and not a substitute for the CoA/SDS):

  • Prepare a DMSO stock (e.g., 10 mM) if compatible; confirm complete dissolution visually and by LC–MS.
  • For plate-based assays, dispense with acoustic or positive-displacement systems; aim for final DMSO ≤0.5–1% v/v unless your assay specifies otherwise.
  • Include controls for solvent, signal window, and potential interference. Use counterscreens/orthogonal assays to validate activity.

Please refer to your internal SOPs and the lot-specific CoA/SDS for authoritative instructions.

Biological Roles

No biological mechanism, target class, or pathway information is provided for FPFT-2216 in the Product Data. Therefore, no item-specific biological roles can be inferred.

General considerations for small-molecule library members (not specific to FPFT-2216):

  • Potential roles in research include acting as tool compounds or preliminary hits in target-based or phenotypic assays. Until a target is validated, treat any observed activity as provisional and subject to orthogonal confirmation.
  • Evaluate assay interference risks (e.g., PAINS motifs, redox cycling, metal chelation, covalent reactivity) using cheminformatics filters once structural information is available from the CoA or internal disclosure.
  • Determine physicochemical liabilities affecting biological readouts—aggregation propensity, permeability, efflux susceptibility—using standard profiling panels (solubility, logD, pKa, PAMPA/MDCK, microsomal stability), if the project scope requires it.

No clinical, diagnostic, or therapeutic claims are made. This material is supplied strictly for research use only, as indicated in the Product Data.

Buffer Applications

Not typically applicable. FPFT-2216 is a small organic screening compound rather than a buffering reagent. No buffer capacity, pKa, or formulation details are provided in the Product Data.

Practical note (general): when preparing assay solutions containing small molecules, choose a buffer appropriate to the biological system (e.g., HEPES pH 7.4, PBS, Tris) and verify compound stability across the intended pH range. Keep final organic cosolvent levels within assay tolerance.

Green Alternatives

Because the structure and solvent needs of FPFT-2216 are not disclosed, specific green substitutions cannot be prescribed. The following general guidance may help reduce environmental impact during handling and screening without altering the compound itself.

  • Greener dissolution/dilution strategies (general guidance)

    • Use the minimum DMSO concentration necessary for solubility; keep final assay DMSO ≤0.5–1% where feasible.
    • Prefer ethanol or water-miscible bio-friendly solvent systems when compatible with the assay and compound stability.
  • Plate management

    • Consolidate screening plates to reduce dead volume and solvent waste. Employ low-evaporation seals to minimize rework and disposal.
  • Cleaning and waste

    • Substitute halogen-free solvents for glassware cleanup where possible (e.g., EtOH/IPA before resorting to chlorinated solvents). Segregate halogenated from non-halogenated waste streams to enable reclamation.
  • Energy and cold-chain efficiency

    • Given −80°C storage, optimize aliquot sizing to limit door-open times and freeze–thaw events. Batch pick with dry ice to reduce compressor load.
  • Comparison note

    • If method development allows, choose greener assay buffers (phosphate, HEPES) and avoid high loads of toxic cosolvents. For synthesis (if later applicable), solvent selection guides such as CHEM21 or ACS GCI should be consulted once the compound’s reactivity/solubility class is known.
Pharmaceutical Uses

No pharmacopeial status, excipient role, or formulation use is specified for FPFT-2216 in the Product Data. It is supplied for research use only.

General guidance (not item-specific):

  • If used in preclinical research workflows (e.g., early discovery), ensure documentation of lot-specific purity, identity, and concentration (qNMR or validated LC–UV). Confirm absence of reactive impurities that could confound ADME/tox assays.
  • Do not use in human or veterinary applications. No claims regarding therapeutic benefit, safety, or efficacy are made or implied.
Physical Properties

Item-specific physical constants are not disclosed for this product.

  • From Product Data

    • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
    • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
  • Common physicochemical parameters (not provided; do not treat as specifications)

    • Melting point (MP): Not specified for this item; refer to CoA/Spec Sheet.
    • Boiling point (BP): Not specified for this item; refer to CoA/Spec Sheet.
    • Density: Not specified for this item; refer to CoA/Spec Sheet.
    • Solubility (water/organic): Not specified for this item; refer to CoA/Spec Sheet.
    • LogP/logD: Not specified for this item; refer to CoA/Spec Sheet.
    • pKa: Not specified for this item; refer to CoA/Spec Sheet.
    • Refractive index/UV cutoff: Not specified for this item; refer to CoA/Spec Sheet.

General guidance for screening compounds (literature/practice, not item-specific):

  • If the compound is a typical drug-like small molecule, initial dissolution is often feasible in DMSO at 10–50 mM. Aqueous solubility can vary widely; consider using co-solvent systems (e.g., DMSO→buffer or DMSO:PEG400:H2O) during assay preparation.
  • Hygroscopic or low-Tg amorphous solids may oil-out upon warming—open vials cold and minimize exposure to ambient humidity. Verify physical form (solid vs film) visually before weighing.
  • For photolabile chemotypes (unknown here), protect from light during handling. Always confirm exact physical properties on the lot-specific CoA before method development.
Quality and Grades
  • From Product Data

    • Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
  • How to interpret grade (general guidance; not item-specific specifications)

    • “Screening” or “library” compounds are commonly supplied with LC–MS identity confirmation and an HPLC purity report (often ≥90–95% by one or more methods). The exact acceptance criteria vary by supplier and are defined on the CoA.
    • If chromatographic applications (e.g., reference standards) are intended, consider requiring additional metrics such as residual solvent content (GC), water content (Karl Fischer), and orthogonal purity (UPLC on two columns). Do not assume these unless stated on the CoA.
  • Stabilizers/additives

    • Any stabilizer, salt form, or hydration state would be declared on the CoA if present. None are specified in the provided data.
  • Recommended incoming QC (general practice)

    • Verify identity by LC–MS (expected [M+H]+) using the CoA-reported mass; confirm retention time match and isotopic pattern.
    • Cross-check purity by HPLC/UPLC with orthogonal gradients; investigate late-eluting non-volatile impurities if the material will be used in biology.
    • For hit-to-lead campaigns, consider quantitative NMR (qNMR) for assay stock concentration accuracy.

Always treat the CoA/Spec Sheet for your specific lot as authoritative for grade, purity, and analytical conditions.

Reaction and Applications

From Product Data, FPFT-2216 is offered as part of a small-molecule/compound library. No synthetic/reactivity information or intended chemical transformations are specified for this item.

  • Research application context (general, not item-specific specifications)

    • Typical use cases include primary/secondary screening in biochemical, biophysical, or cell-based assays; chemical probe exploration; and SAR development upon hit confirmation.
    • Compounds in screening collections are often evaluated across panels (enzymes, receptors, transporters) for target discovery workflows. Ensure appropriate counterscreens to identify assay interference (e.g., aggregators, redox cyclers, fluorescence quenchers/enhancers).
  • Assay development considerations (general practice)

    • Confirm compound integrity by LC–MS before each major campaign, especially after multiple freeze–thaw cycles.
    • Assess stability in assay buffers (e.g., DMSO→buffer dilution) via time-course LC–MS to flag rapid hydrolysis or oxidation.
    • Use orthogonal readouts where possible (e.g., enzymatic activity plus biophysical binding) to reduce false positives.
  • Not provided for this item

    • No named reactions, catalytic applications, or building-block roles are claimed in the product data. If synthetic utility is required, obtain structural information from the CoA or contact technical support for guidance on compatibility with common transformations.
Reaction Conditions

Not applicable based on provided data. No reactions or transformations are specified for FPFT-2216, and the structure is undisclosed.

General guidance if synthetic manipulation is planned after structure disclosure (non-specific):

  • Establish solvent and temperature windows via DSC/TGA and small-scale stability screens.
  • Use anhydrous, oxygen-free conditions for air/moisture-sensitive motifs; otherwise, standard conditions may suffice.
  • For scale-up or medicinal chemistry campaigns, record detailed conditions (solvent grade, water content, equivalents, temperature profile) and monitor by LC–MS/UPLC to track starting material consumption and impurity growth.
Safety and Handling

Authoritative safety information must be taken from the product SDS. The following summarizes what is and is not provided and offers prudent lab practices for an undisclosed small-molecule screening compound.

  • From Product Data

    • GHS classification: Not specified for this item; refer to SDS.
    • Signal word / H-statements / pictograms: Not specified for this item; refer to SDS.
  • General laboratory precautions (good practice for unknown toxicological profiles)

    • Handle in a certified chemical fume hood; avoid inhalation of dust/aerosols.
    • Wear appropriate PPE: lab coat, safety glasses, and chemically resistant gloves (e.g., nitrile). Consider double-gloving for DMSO solutions that can enhance dermal absorption.
    • Avoid skin/eye contact and ingestion. Prevent environmental release until hazards are known.
    • Storage incompatibilities: Keep segregated from strong oxidizers, strong acids/bases, and reactive reducing agents until compatibility is established (general guidance).
    • Thermal sensitivity: Store at −80°C as specified. Allow to equilibrate in a desiccator before opening to prevent condensation. Cold vials can cause frostbite—use cryo gloves when handling with dry ice.
  • First-aid overview (consult SDS)

    • Inhalation: Move to fresh air; seek medical attention if symptoms persist.
    • Skin/eye contact: Rinse with water for at least 15 minutes; remove contaminated clothing; obtain medical advice.
    • Ingestion: Rinse mouth; do not induce vomiting unless directed by medical personnel; seek immediate medical attention.
  • Spill/cleanup

    • Contain solids with inert absorbent, avoid dust formation, and dispose per institutional hazardous waste procedures. Decontaminate surfaces with suitable organic solvent followed by detergent/water, per SDS guidance.
Solvent Selection

No item-specific solubility profile is provided. The following is general guidance for small-molecule screening compounds and should not be treated as specifications.

  • Primary solvent for stocks (general practice)

    • DMSO is the default due to broad solvating power and assay compatibility. Start with 10 mM stock; increase to 20–50 mM only if fully dissolved without visible particulates.
  • Secondary solvents/co-solvents (if DMSO insufficient)

    • DMF or NMP (anhydrous) can improve dissolution; subsequently back-dilute into aqueous buffers with 0.1–1% final organic.
    • EtOH or MeOH may be acceptable for certain biochemical assays; check assay tolerance and compound stability.
    • For hydrophobic compounds, consider cosolvent systems (e.g., DMSO:PEG400:water or DMSO:Tween-80:buffer) while monitoring aggregation.
  • Aqueous buffers

    • Adjust pH to favor ionization of acidic/basic functional groups if known; without structure, empirically screen pH 5.5–7.4. Use 0.01–0.05% non-ionic surfactant to mitigate nonspecific binding and aggregation where permitted.
  • Practical tips

    • Warm gently (25–40°C) and vortex/sonicate to assist dissolution; avoid prolonged heating.
    • Filter 0.2 µm if assay permits; confirm no adsorption losses.
    • Record exact solvent composition on plates/tubes for reproducibility.
  • Solvent compatibility in assays

    • Keep final DMSO ≤0.5–1% v/v for sensitive cell assays and ≤2% for many biochemical assays, unless the specific assay indicates otherwise.
Storage and Reconstitution
  • From Product Data (item-specific)

    • Storage conditions: Store at −80°C.
    • Shipping: Dry ice packs + cold packs.
  • Storage guidance (specific plus best practice)

    • Maintain at −80°C in a dry, dark environment. Minimize freeze–thaw by aliquoting upon first receipt. Keep vials tightly closed with desiccant where possible. Allow vials to equilibrate to low humidity (e.g., in a desiccator) before opening to prevent condensation.
    • Track inventory with barcodes and record the number of freeze–thaw cycles; retire aliquots after several cycles to preserve integrity.
  • Reconstitution (general practice; not item-specific specifications)

    • Preferred solvent: DMSO for initial stock preparation unless your CoA indicates otherwise. Start at 10 mM; adjust concentration based on solubility and assay needs.
    • Procedure: Bring vial to room temperature in a desiccator, briefly centrifuge to collect contents, add calculated solvent volume, vortex and, if needed, sonicate briefly. Inspect for clarity and absence of particulates. If necessary, warm gently (≤40°C) and refilter through 0.2 µm PTFE/NYLON if compatible.
    • Storage of solutions: Keep DMSO stocks at −20 to −80°C, protected from light. Avoid repeated freeze–thaw. Use single-use aliquots for HTS to ensure consistent concentration.
  • Stability

    • No stability data are provided. For working assurance, periodically verify by LC–MS/HPLC after storage to confirm identity and purity. Always defer to the lot-specific CoA for any available stability information.
Structure and Identity

Brief overview: FPFT-2216 is listed as a small-molecule library member with a defined CAS registry number but no disclosed structural identifiers in the product data.

  • Item-specific identifiers (from Product Data)

    • SKU: F656278
    • Product name: FPFT-2216
    • CAS: 2367619-87-0
    • Category: Small molecules and compound library (全部 / 可售 / 小分子和化合物库)
    • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
    • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
    • InChIKey: Not specified for this item; refer to CoA/Spec Sheet.
    • SMILES: Not specified for this item; refer to CoA/Spec Sheet.
  • Structural features

    • 2D/3D structural details, ring systems, functional groups, and stereochemistry are not disclosed in the provided data. No structural description can be given without SMILES/InChI or a chemical name.
  • Notes on identity confirmation (general guidance)

    • For screening compounds, identity is typically supported by LC–MS and 1H NMR data on the lot-specific CoA. Where structure is confidential/undisclosed, an internal code (here, FPFT-2216) plus CAS may be used to track identity.
    • If further characterization is needed, recommended orthogonal methods include HRMS, 13C NMR, and HPLC purity profiling under at least two orthogonal stationary phases (general practice, not item-specific).
Synthetic Utility

No structural information or reactive functional groups are disclosed in the Product Data for FPFT-2216; therefore, no item-specific synthetic roles can be described.

General note for library compounds (non-specific):

  • If structure becomes available (e.g., under CDA), typical synthetic utility assessments include: functional group interconversions, opportunities for parallel synthesis to generate analogs, and feasibility of late-stage diversification (e.g., cross-coupling handles, heteroatom alkylations/acylations).
  • Before attempting any transformation, confirm identity/purity and assess stability to bases/acids, oxidants/reductants, and temperature via micro-scale scouting experiments.
Target Specificity

No target, binding profile, or selectivity data are provided in the Product Data for FPFT-2216. As supplied, it is a screening library compound with no declared biological target or specificity. Consult your assay results and any disclosed structure for project-specific target assessment.

Preguntas frecuentes

How should this product be stored?
Store at ?80 °C. Ultra-low temperature storage is required to maintain the specified shelf life.
How is this product shipped?
This product ships frozen with dry ice and cold packs. Unpack on arrival and transfer it to the storage condition stated above; handle dry ice with insulated gloves in a ventilated area.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 2367619-87-0, the molecular formula is C12H12N4O3S, and the molecular weight is 292.31 g/mol.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

¿Quieres que te enviemos un mensaje cuando tengamos descuentos disponibles?

Recordármelo más tarde

¡Gracias! Por favor, revisa tu bandeja de entrada de correo electrónico para confirmar.

¡Vaya! Las notificaciones están desactivadas.