Haloxon  - ≥98% , CAS No.321-55-1

CAS: 321-55-1 Cat. No.: H693433 Fórmula: C14H14Cl3O6P Peso molecular: 415.59 Número EC: 206-289-1 PubChem CID: 9454
Disponible para pedir
CALIDAD & PUREZA ≥98%
Storage
Room temperature
★
Talla
Alemania (EU)
USA*
Precio
Cantidad
5mg
H693433-5mg
Fabricado bajo pedido · 8–12 semanas

858,11€

1.001,28€
Guardar 143,18 € (14.30%)
10mg
H693433-10mg
Fabricado bajo pedido · 8–12 semanas

1.225,16€

1.429,95€
Guardar 204,79 € (14.32%)
Enter a quantity for the sizes you want to add.

Especificaciones

Especificaciones y pureza
≥98%
Condiciones de almacenamiento de almacenamiento
Room temperature
Tipo de acción
INHIBITOR
Pureza
≥98%
Nombres e identificadores
SMILES
CC1=C(C(=O)OC2=C1C=CC(=C2)OP(=O)(OCCCl)OCCCl)Cl
IUPAC Name
bis(2-chloroethyl) (3-chloro-4-methyl-2-oxochromen-7-yl) phosphate
InChIKey
KULDXINYXFTXMO-UHFFFAOYSA-N
InChI
1S/C14H14Cl3O6P/c1-9-11-3-2-10(8-12(11)22-14(18)13(9)17)23-24(19,20-6-4-15)21-7-5-16/h2-3,8H,4-7H2,1H3
Isómeros SMILES
CC1=C(C(=O)OC2=C1C=CC(=C2)OP(=O)(OCCCl)OCCCl)Cl
PubChem CID
9454
Peso molecular
415.59

Datos avanzados

Taxonomic Classification

Taxonomy Tree

KingdomOrganic compounds
SuperclassPhenylpropanoids and polyketides
ClaseCoumarins and derivatives
SubclassNot available
Intermediate Tree Nodes Not available
Direct ParentCoumarins and derivatives
Alternative Parents 1-benzopyrans  Pyranones and derivatives  Dialkyl phosphates  Benzenoids  Aryl chlorides  Heteroaromatic compounds  Lactones  Oxacyclic compounds  Organooxygen compounds  Organochlorides  Organic oxides  Hydrocarbon derivatives  Alkyl chlorides  
Molecular FrameworkAromatic heteropolycyclic compounds
Substituents Coumarin - Benzopyran - 1-benzopyran - Pyranone - Dialkyl phosphate - Aryl chloride - Aryl halide - Organic phosphoric acid derivative - Phosphoric acid ester - Pyran - Alkyl phosphate - Benzenoid - Heteroaromatic compound - Lactone - Oxacycle - Organoheterocyclic compound - Alkyl chloride - Organooxygen compound - Organochloride - Organohalogen compound - Hydrocarbon derivative - Alkyl halide - Organic oxygen compound - Organic oxide - Aromatic heteropolycyclic compound
DescripciónThis compound belongs to the class of organic compounds known as coumarins and derivatives. These are polycyclic aromatic compounds containing a 1-benzopyran moiety with a ketone group at the C2 carbon atom (1-benzopyran-2-one).
External Descriptors Not available
Estructura 3D
Modelo de Estructura Química Interactiva





Objetivos asociados (humanos)
TDP1 Tchem Tyrosyl-DNA phosphodiesterase 1 (345557 Activities)
Activity TypeRelationActivity valueUnitsAction TypeJournalPubMed IddoiAssay Aladdin ID
Objetivos asociados (no humanos)
Plasmodium falciparum (966862 Activities)
Activity TypeRelationActivity valueUnitsAction TypeJournalPubMed IddoiAssay Aladdin ID
Mecanismos de acción
Certificados (CoA, COO, BSE/TSE y tabla de análisis)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Propiedades químicas y físicas
Peso molecular415.6
XLogP33.300
Hydrogen Bond Donor Count0
Hydrogen Bond Acceptor Count6
Rotatable Bond Count8
Exact Mass413.959 Da
Monoisotopic Mass413.959 Da
Topological Polar Surface Area71.100 Ų
Heavy Atom Count24
Formal Charge0
Complexity529.000
Isotope Atom Count0
Defined Atom Stereocenter Count0
Undefined Atom Stereocenter Count0
Defined Bond Stereocenter Count0
Undefined Bond Stereocenter Count0
The total count of all stereochemical bonds0
Covalently-Bonded Unit Count1
Seguridad y peligros (GHS)
Pictogramas
Señal
Warning
Indicaciones de peligro

H302:Harmful if swallowed

H315:Causes skin irritation

H319:Causes serious eye irritation

H332:Harmful if inhaled

H335:May cause respiratory irritation

Precauciones

P261:Avoid breathing dust/fume/gas/mist/vapors/spray.

P264:Wash hands [and …] thoroughly after handling.

P270:Do not eat, drink or smoke when using this product.

P271:Use only outdoors or in a well-ventilated area.

P280:Wear protective gloves/protective clothing/eye protection/face protection.

P321:Specific treatment (see ... on this label).

P330:Rinse mouth.

P302+P352:IF ON SKIN: wash with plenty of water.

P304+P340:IF INHALED: Remove person to fresh air and keep comfortable for breathing.

P305+P351+P338:IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do - continue rinsing.

P362+P364:Take off contaminated clothing and wash it before reuse.

P405:Store locked up.

P403+P233:Store in a well-ventilated place. Keep container tightly closed.

P501:Dispose of contents/container to an approved waste disposal plant.

P264+P265:Wash hands [and …] thoroughly after handling. Do not touch eyes.

P301+P317:IF SWALLOWED: Get medical help.

P317:Get emergency medical help.

P337+P317:If eye irritation persists: Get medical help.

P332+P317:If skin irritation occurs: Get medical help.

P319:Get medical help if you feel unwell.

Calculadoras de soluciones
Reseñas

Reseñas de cliente

Application Protocols

No tested application protocols are provided for this listing. The compound is supplied for general research use; method development is user-defined.

General laboratory protocol suggestions (to be adapted and validated):

  • Preparation of stock solutions: Dissolve the compound in a dry, anhydrous solvent (e.g., acetonitrile, DCM, EtOAc) to prepare a 10–100 mM stock. Filter through a 0.2 µm PTFE filter if particulate matter is present. Record exact concentration gravimetrically if possible.
  • Stability check: Analyze a fresh aliquot by 31P NMR or LC–MS immediately after dissolution and after 24–72 h at intended storage conditions to confirm stability.
  • Purity assessment: Use HPLC (UV/ELSD) or GC with appropriate methods; include a stability-indicating gradient capable of resolving hydrolysis products.
  • Reaction scouting (if used as reagent/intermediate): Perform 5–20 mg scale tests across 2–3 solvents and 2–3 bases at 0–25°C; monitor by 31P NMR. Select conditions minimizing side-reactions.

Assay-specific instructions (e.g., WB, IHC, IF, FC): Not applicable; no antibody or bioassay kit information is associated with this item.

Always defer to your institution’s SOPs and the SDS for safety and waste handling. Document all parameters in ELNs for reproducibility.

Biological Roles

No item-specific biological characterization is provided in this listing; the product is designated for research use only.

General literature context (not item specifications):

  • Organophosphorus esters are widely studied for their interactions with serine hydrolases and other enzymes via phosphoryl transfer chemistry. Such interactions can range from reversible binding to covalent modification depending on structure and conditions.
  • In biochemical research, organophosphate analogs can be used as mechanistic probes in enzyme kinetics, model substrates for studying hydrolysis pathways, or references in analytical methods targeting phosphorus-containing xenobiotics.
  • Environmental/biotransformation studies often examine hydrolysis (enzymatic and nonenzymatic), oxidation/reduction at phosphorus or substituents, and conjugation pathways.

Practical research considerations:

  • Where enzymology is involved, confirm purity and identity by 31P NMR and LC–MS to avoid misassignments due to hydrolysis products.
  • Establish buffer conditions that minimize non-specific hydrolysis if kinetic measurements are intended.
  • When handling in biological labs, ensure fume hood use and appropriate containment given the potential toxicity of organophosphorus esters.

Important use note: For research use only. Not for human or veterinary use, diagnostic procedures, or clinical applications. Avoid implying physiological efficacy or therapeutic utility; limit use to in vitro/in vivo laboratory studies consistent with institutional approvals.

Buffer Applications

This compound is not a classical buffering agent and is not typically used to establish or maintain pH in aqueous systems.

If your research requires handling this compound in aqueous media (general guidance):

  • Choose buffers that minimize hydrolysis (often near neutral pH, low ionic nucleophilicity). Phosphate, HEPES, or MOPS buffers at pH 6.8–7.4 are common starting points; verify stability by 31P NMR or LC.
  • Avoid strongly basic buffers (e.g., carbonate pH >9) or strongly acidic conditions if the goal is to preserve the parent ester.
  • Incorporate co-solvents (e.g., acetonitrile, DMSO at low percentages) to aid solubility, while validating that the co-solvent does not accelerate degradation.

Item-specific buffer compatibility, pKa, and aqueous solubility: Not specified for this item; refer to CoA/Spec Sheet and determine empirically for your application.

Green Alternatives

Greenness considerations here pertain to handling and solvent choices around this compound, since the intrinsic hazard profile of organophosphorus esters may pose environmental and health concerns. Selection of media and process conditions can mitigate impact without altering the identity of the compound.

  • Safer solvent choices (general guidance):
    • Prefer ethyl acetate, 2-methyltetrahydrofuran (2-MeTHF), or dimethyl carbonate (DMC) where compatible, instead of chlorinated solvents like dichloromethane.
    • Use acetonitrile or propylene carbonate over DMF/DMAc where feasible to reduce reproductive toxicity concerns (always check downstream compatibility and waste handling).
  • Process intensification: Miniaturize, use flow chemistry, and adopt in-line analytics (e.g., 31P NMR or IR) to reduce material inventory and exposure.
  • Waste minimization: Segregate phosphorus-containing waste; implement base-catalyzed hydrolysis quench where permitted by your EHS program to deactivate reactive phosphorus esters before disposal.

Illustrative comparison (general; not item-specific):

  • DCM vs EtOAc: EtOAc is biodegradable, lower toxicity, and lower environmental impact; DCM often offers superior solubility but raises VOC and toxicity concerns.
  • THF vs 2-MeTHF: 2-MeTHF originates from renewable sources and can lower peroxide risk operationally (still test for peroxides); THF is widely available but forms peroxides readily.

Note: Intrinsic toxicity/hazard of organophosphorus esters typically dominates greenness scoring. Engineering controls, closed handling, and rigorous waste management are crucial regardless of solvent choice.

Pharmaceutical Uses

No pharmacopeial status, excipient role, or formulation specifications are provided for this item. The product is supplied strictly for research use only and is not intended for therapeutic, diagnostic, or veterinary applications.

General formulation context (non-clinical, for method development in labs):

  • Organophosphorus esters can be studied as reference materials in analytical method validation (e.g., LC–MS/MS) for impurity profiling or environmental monitoring workflows. In such contexts, solvent selection, stability-indicating methods, and storage conditions must be rigorously defined.
  • Where nonclinical formulation is necessary (e.g., for preclinical toxicology or mechanistic studies under appropriate approvals), vehicles often include polyethylene glycol, aqueous micellar systems, or cosolvent blends; however, any such use must be guided by internal SOPs and regulatory frameworks.

Compliance reminders:

  • Do not incorporate this material into products for human or animal administration.
  • Do not claim or imply therapeutic benefit or dosing. All handling should remain within the scope of laboratory research under institutional oversight.

Item-specific pharmacopeia references, residual solvent limits, and excipient compatibility: Not specified for this item; refer to CoA/Spec Sheet.

Physical Properties

Only item-specific values provided in this listing are included; all others are left unspecified. Use the product’s CoA and SDS for authoritative specifications when establishing handling or analytical methods.

Item-specific data from this listing:

  • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.

Commonly referenced (literature/general) properties for organophosphorus esters (not item specifications):

  • Physical state: often liquids or low-melting solids, sometimes with modest volatility; exact MP/BP depend strongly on substituents.
  • Density and refractive index: organophosphates frequently show densities near or above 1.1 g/mL and refractive indices ≥1.42 (literature, class generalization). Do not use as acceptance criteria.
  • Solubility: many are sparingly soluble in water and readily soluble in common organic solvents (e.g., dichloromethane, acetone, acetonitrile, alcohols). Actual miscibility must be confirmed experimentally for this item.
  • pKa/logP: organophosphate esters are typically neutral under ambient conditions, with logP spanning wide ranges per structure; empirical determination is recommended.

If method development is planned (e.g., GC/LC):

  • Establish a primary identity/assay method (e.g., 1H/13C/31P NMR, HRMS, and HPLC/GC purity) based on your internal standards.
  • Determine working solvent and stability profile by small-scale scouting (light, heat, base/acid sensitivity), as organophosphorus esters can hydrolyze or transesterify under harsh conditions.

All numeric property values not listed above: Not specified for this item; refer to CoA/Spec Sheet.

Quality and Grades

Item-specific quality details are not provided in this listing.

  • Grade/purity: Not specified for this item; refer to CoA/Spec Sheet.
  • Stabilizers/inhibitors: Not specified for this item; refer to CoA/Spec Sheet.
  • UV cutoff/LC baseline suitability: Not specified for this item; refer to CoA/Spec Sheet.

Guidance for interpreting grades (general, for planning purposes only):

  • Research or technical grade typically ensures identity and nominal purity suitable for exploratory synthesis or method development. Analytical, HPLC, or LC–MS grades emphasize tighter control of nonvolatile residue and UV-absorbing impurities for detection-sensitive workflows.
  • For organophosphorus esters, trace water and alcohols can induce hydrolysis or transesterification; even when purity meets assay limits, microimpurities may impact stability. Confirm residual solvent/water by KF and headspace GC if relevant to your application.
  • If your use case is quantitative (e.g., reference standard, toxicology, kinetic studies), request batch-specific CoA including assay method, impurity profile, residual solvents, water content, and where relevant, 31P NMR purity/identity.

Quality control suggestions (general):

  • On receipt: verify identity by 1H/13C and 31P NMR and HRMS; check purity by GC/LC.
  • Track stability: store aliquots at room temperature as listed, and consider retention samples in cool/dry/dark conditions to benchmark stability vs. time.
  • Document any stabilizers declared on the CoA; they can interfere with certain reactions or analyses.
Reaction and Applications

Manufacturer-supplied application notes are not provided in this listing. The following comments reflect general uses and considerations for organophosphorus esters; they are not exhaustive and are not item-specific specifications.

  • Reactivity profile (literature/general): Organophosphorus(V) esters can act as electrophiles at phosphorus, undergoing nucleophilic substitution (P–X ↔ P–OR exchange) and hydrolysis. The rate and selectivity depend on substituents, leaving groups, and conditions (solvent, pH, catalysts).
  • Catalysis and activation: Bases, nucleophilic catalysts, or Lewis acids can accelerate transesterification or substitution at phosphorus. Phase-transfer conditions may assist when aqueous nucleophiles are used.
  • Stability considerations: Hydrolytic lability is a key factor; control water content and temperature. 31P NMR is recommended to monitor integrity during reactions or storage.
  • Applications in synthesis (general): Phosphorylation of alcohols/diols, preparation of mixed phosphate esters, and generation of isotopically labeled phosphates (with appropriate precursors) are representative families. Some organophosphates serve as standards or surrogates in environmental or analytical method development.
  • Workup/purification: Avoid prolonged exposure to silica or alumina under moist conditions. Neutral or buffered aqueous workups at low temperature reduce decomposition.

Practical tips:

  • Use anhydrous solvents, molecular sieves, and inert atmosphere when hydrolysis would compromise your outcome.
  • If derivatization or exchange at phosphorus is intended, pre-screen conditions on milligram scale; product distributions can be sensitive to small changes in base strength and solvent polarity.

Item-specific “Manufacturer Applications”: Not provided in listing.

Reaction Conditions

No item-specific reaction condition data are provided. The following general conditions pertain to organophosphorus ester chemistry and should be validated experimentally for this product.

Typical condition motifs (literature, general):

  • Nucleophilic substitution at P: Neutral to mildly basic media in aprotic solvents (e.g., acetonitrile, THF, DCM). Catalysts: tertiary amines (Et3N, DIPEA), DMAP, or Lewis acids depending on leaving groups. Temperatures: 0–60°C. Times: 0.5–24 h.
  • Transesterification: Alcohol (2–10 equiv) with base (NaH, t-BuOK, or alkoxides generated in situ) in THF/MeCN; 0–25°C to control selectivity. Monitor by 31P NMR.
  • Hydrolysis (if desired for degradation studies): Buffered aqueous media; rates increase with pH and temperature. Use carbonate (pH 10) or dilute acid (pH 1–2) as bracketing conditions for kinetic profiling.
  • Stabilization during workup: Quench reactive intermediates at low temperature, partition rapidly, and dry organic layers over neutral agents (Na2SO4, MgSO4) to reduce secondary hydrolysis.

Analytical methods:

  • 31P NMR (primary), 1H/13C NMR, LC–MS/HRMS for mass confirmation, and HPLC/GC for purity. Calibrate 31P chemical shift using external standards (e.g., 85% H3PO4, set to 0 ppm).

Expected yields/selectivity: Highly structure-dependent; no item-specific expectations are provided in this listing. Perform small-scale screens to map solvent/base/temperature spaces before scale-up.

Safety and Handling

Safety data specific to this catalog entry are not provided in the listing and must be taken from the SDS.

Provided item data:

  • GHS signal word: Not specified for this item; refer to SDS.
  • H-statements: Not specified for this item; refer to SDS.
  • GHS classification/pictograms: Not specified for this item; refer to SDS.
  • Storage conditions: Room temperature (per listing). Protect container from moisture and incompatible reagents.

General precautions for organophosphorus compounds (literature; not a substitute for the SDS):

  • Toxicity: Many organophosphorus esters can be acutely toxic and may inhibit serine hydrolases. Avoid inhalation, ingestion, and skin contact. Work in a fume hood with appropriate containment.
  • PPE: Laboratory coat, nitrile gloves (double-gloving for extended handling), splash goggles; change gloves frequently. Use closed systems or syringe/Schlenk techniques to minimize exposure.
  • Incompatibilities: Strong bases/acids (can promote hydrolysis or transesterification), strong oxidizers, and moisture (potential hydrolysis). Avoid heating to decomposition and sources of ignition if volatile.
  • First aid (overview; defer to SDS): Remove contaminated clothing. Skin/eye contact: immediate decontamination with copious water. Inhalation: move to fresh air; seek medical attention. Ingestion: do not induce vomiting; seek medical attention immediately.
  • Spill/cleanup: Contain and absorb with inert material; avoid aerosolization. Decontamination of organophosphates can involve alkaline hydrolysis under controlled conditions; follow institutional protocols and the SDS.

Waste disposal: Treat as hazardous chemical waste; segregate per institutional and local regulations. Document all disposals.

Solvent Selection

This item is itself a named compound rather than a general-purpose solvent. However, solvent choice is crucial for its handling, dissolution, purification, and reactivity studies.

General guidance (literature/class-level for organophosphorus esters):

  • Polarity and miscibility: Many organophosphates dissolve well in moderately polar aprotic solvents (e.g., dichloromethane, acetonitrile, THF, ethyl acetate). Solubility in alcohols is also common but may risk transesterification in strongly acidic/basic conditions.
  • Water: Frequently sparingly soluble; measure actual solubility before aqueous work. Hydrolysis risk increases in aqueous media, especially at elevated pH.
  • Chromatography: For silica gel purification, use nonbasic eluents (hexane/EtOAc or DCM/MeOH with minimal base). Monitor for hydrolysis or tailing; pre-neutralized silica or rapid flash methods can help.
  • NMR: For characterization, CDCl3, CD2Cl2, acetone‑d6, or acetonitrile‑d3 are common choices; 31P NMR provides rapid identity/stability assessment.

Comparison pointers (when selecting diluents for reactions or stock solutions):

  • DCM vs EtOAc: DCM offers higher solubility and lower nucleophilicity; EtOAc is more benign but may participate in exchange under strong conditions.
  • MeCN vs THF: MeCN is robust toward many conditions; THF offers strong solvation of salts but is peroxide-forming and more moisture-sensitive.

Item-specific solubility data: Not specified for this item; verify experimentally and consult the CoA.

Storage and Reconstitution

Item-specific storage information provided:

  • Storage conditions: Room temperature (per listing). Maintain in a tightly closed container, in a dry, well-ventilated place. Protect from moisture and direct sunlight.
  • Shipped in: Not specified for this item; refer to CoA/Spec Sheet.
  • Appearance on receipt: Not specified for this item; refer to CoA/Spec Sheet.

General recommendations for organophosphorus esters (literature; supplement to item listing):

  • Container: Use amber glass with PTFE-lined cap to limit permeation and moisture ingress. For long-term storage, consider subdividing into single-use aliquots under dry inert gas.
  • Environmental controls: Avoid prolonged exposure to elevated temperature or humidity. If hydrolysis sensitivity is a concern, store over desiccant in a secondary sealed container.
  • Reconstitution/solution preparation: Use anhydrous solvents (e.g., acetonitrile, dichloromethane, ethyl acetate). Prepare fresh solutions immediately before use where feasible. If stock solutions must be kept, store at 2–8°C or −20°C in sealed vials and validate stability by 31P NMR/LC after thawing (this is general guidance; not item-specific).
  • Freeze–thaw: For neat solid/liquid, minimize freeze–thaw cycling by aliquoting. For solutions, avoid repeated thawing; discard if precipitation, discoloration, or LC/NMR changes are observed.

All unspecified storage/stability parameters (e.g., shelf life, permissible moisture): Not specified for this item; refer to CoA/Spec Sheet.

Structure and Identity

Brief overview: Haloxon is supplied as a research/lab chemical. Core identity elements in the present listing are minimal; consult the CoA/SDS for definitive identifiers before use in regulated work.

  • Product name: Haloxon (SKU: H693433)
  • CAS: 321-55-1 (provided)
  • PubChem CID: 9454 (provided)
  • InChIKey: 189946 (as provided; note this is not in the standard 27-character InChIKey format; verify against CoA/SDS)
  • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
  • SMILES: Not specified for this item; refer to CoA/Spec Sheet.

Structural features (general/literature context):

  • Literature places “Haloxon” within the family of organophosphorus esters (phosphorus(V) compounds). Specific ring systems/aryl content and stereochemical features should be verified on receipt (literature information varies by supplier and regulatory listing).
  • Functional groups expected for this class include a phosphoryl P=O moiety and labile P–X or P–OR bonds (literature, general to organophosphates). Do not rely on this description for analytical confirmation.

2D description (general):

  • Organophosphorus esters typically feature a central tetra-coordinated phosphorus (P(V)) bearing a double-bonded oxygen and three single-bond substituents (alkoxy/halide/aryl; literature). For this specific item, the exact substitution pattern is not specified here; confirm via CoA/NMR/HRMS/IR prior to quantitative work or method development.
Synthetic Utility

Without an explicit structure in this listing, synthetic discussions are framed at the organophosphorus ester class level. Verify applicability to this item by consulting the CoA and confirming structure by spectroscopy.

  • Functional group behavior (general): The phosphoryl P=O activates phosphorus toward nucleophilic substitution. Leaving groups at phosphorus (e.g., halide or good alkoxides) enable exchange with alcohols, amines, or thiols under appropriate conditions. Hydrolysis yields phosphate mono/diesters or phosphoric acid derivatives.
  • Transformations: Transesterification at phosphorus, nucleophile-promoted displacement (SN2(P)), and, with tailored substrates, Arbuzov-like rearrangements or Atherton–Todd phosphorylation pathways (when auxiliary reagents are used) can be relevant.
  • Protecting group logic: Phosphate esters can function as protected forms of inorganic phosphate; selective deprotection/hydrolysis conditions allow stepwise access to mono/di/triesters in synthesis of nucleotide analogs or phosphorylated small molecules (general literature).
  • Isotopic and label chemistry: 18O/17O or 32P/33P labeling strategies sometimes leverage phosphorus ester exchange under carefully controlled conditions.

Operational guidance:

  • Carefully control moisture; employ dry solvents and inert atmosphere to avoid unplanned hydrolysis.
  • Use 31P NMR as a rapid reaction monitor to distinguish starting material, intermediates, and hydrolysis products.

Item-specific reactivity parameters (rates, selectivity, solvent effects): Not specified for this item; determine empirically.

Target Specificity

This product is a small-molecule chemical reagent and not a biological targeting reagent (e.g., antibody, enzyme, or probe with defined antigen/epitope specificity) in this listing.

  • Antigen/epitope, clone, isotype, species reactivity: Not applicable.
  • Any biochemical interaction data (e.g., enzyme targets, IC50): Not specified for this item; refer to primary literature and do not infer activity from class-level behavior without direct evidence for this batch.

For research planning: If your work involves biochemical targets (e.g., serine hydrolases or phosphoryl transfer enzymes), establish target engagement with validated assays and authentic standards. Do not assume specificity without experimental confirmation.

¿Quieres que te enviemos un mensaje cuando tengamos descuentos disponibles?

Recordármelo más tarde

¡Gracias! Por favor, revisa tu bandeja de entrada de correo electrónico para confirmar.

¡Vaya! Las notificaciones están desactivadas.