β-Lactamase Ⅳ

Cat. No.: rp216610
AVAILABLE TO ORDER
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. EnzymoPure™ ? EnzymoPure™ — Aladdin's line of high-quality enzymatic solutions. Use when enzyme purity and defined activity drive assay or process performance. Sterile ? Sterile grade — processed and verified free of viable microorganisms. Use directly in aseptic procedures and cell culture without further sterilization. 5000KU/bottle
 ·  off list, applied to all prices below.
Size
Status
Price
Qty
5000KU
rp216610-5000KU
3
$59.90
Enter a quantity for the sizes you want to add.
🧪

Why this grade

EnzymoPure™, BioReagent, sterile, 5000KU/bottle BioReagent,Sterile,EnzymoPure™ for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Store at 2-8°C Ships Wet ice Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Overview

Is it sterile: Yes

Metallozyme is a water-soluble protein using recombinant genes, lyophilized and irradiated with cobalt-60, and aseptic packaging of celine bottles. A recombinant gene protein constructed according to the chemical structure of cephalosporins and penan. The active center of its gene fragment can destroy the chemical structural formula of cephalosporins and penan antibiotics, so that the antibacterial properties of the two drugs are lost after ring opening/chain breaking.
When doing sterility check of antibiotics, use a manual syringe to absorb sterile water and inject it into the drug vial, shake well, dissolve, and then suck it out. Add to 500ml solution of 0.9% sodium chloride, shake well, do not dissolve with the needle on the incubator, input, avoid high concentration of solution through the filter membrane, resulting in difficult to rinse thoroughly.
Here, it is emphasized again: when doing sterile examination of antibiotics, it is necessary to inject sterile water into the manual syringe to dissolve the sample, and then transfer the dissolved sample to 500ml solution of 0.9% sodium chloride, so that the sample will not cause local concentration too high, difficult to wash thoroughly through the filter membrane.
During sterility test, take 1 bottle of freeze-dried metal enzyme powder and add 5ml of sterile water to dissolve, shake well to make a metal enzyme solution, take 2ml of enzyme solution and put 1500ml of washing solution and shake well. After the rinse solution has washed the filter membrane of the incubator, the pump is exhausted. A manual syringe was used to Pierce the respiratory mouth of the three incubators, and 1ml of enzyme solution was added to each of them, and the enzymes were spread on the entire surface of the filter membrane as far as possible. Then, the high concentration of enzymes was fully in contact with the filter membrane of the incubator, so as to destroy (neutralize and inactivate) the residual cephalosporins and penem drugs on the filter membrane, and then pumped into the corresponding medium and shook well. Positive pairs were treated with 1ml of E. coli (100CFU/ml).

Adding 1ml of the metal enzyme solution to the three incubators can remove the residual cephalosporins and penem on the inner wall of the incubators and the surface of the filter membrane.
Shake the positive pair gently once a day in the morning and afternoon.

Customers can do methodological verification according to the above, but also according to the actual operation of the verification.


Specifications

Product Name
β-Lactamase Ⅳ
Synonyms
β-Lactamase
Grade
BioReagent, Sterile, EnzymoPure™
Specifications & Purity
EnzymoPure™, BioReagent, sterile, 5000KU/bottle
Note
This product is about to be sold out and will be discontinued. The replacement product is L140816
Molecule Type
Enzyme
Storage and Shipping
Concentration
5000KU/bottle
Storage
Store at 2-8°C
Shipped In
Wet ice
Stability And Storage
Store at 2-8℃ long term (12 months). Upon receipt, it is recommended to aliquot.

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificates(CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate TypeDateItem
ZJ25F0420229Certificate of AnalysisFeb 24, 2026 rp216610
Documents & Articles
Solution Calculators
Reviews

Customer Reviews

Need help choosing the grade?

Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.

View BioReagent grade guide → View EnzymoPure™ grade guide → View Sterile grade guide →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.