Plant Polyphenol Oxidase (PPO) Activity Assay Kit (Catechol, Micro Method) - BioReagent, high purity

Cat. No.: P1501774
Disponible para pedir
CALIDAD & PUREZA BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
★
Talla
Alemania (EU)
USA*
Precio
Cantidad
48T
P1501774-48T
Fabricado bajo pedido · 8–12 semanas
173,46€
96T
P1501774-96T
Fabricado bajo pedido · 8–12 semanas
268,91€
Enter a quantity for the sizes you want to add.
🧪
Por qué esta calidad

BioReagent BioReagent para flujos de trabajo cromatográficos y analíticos sensibles que requieren una interferencia mínima de la línea base.

🌡

Almacenamiento y envío

Store at 2-8°C,Protected from light Envío Wet ice. Consulte el COA específico del lote para conocer las especificaciones exactas.

📋

Documentos de calidad

SDS, COA, ficha técnica y hoja de especificaciones disponibles para descargar. COA específico del lote accesible mediante búsqueda por número de lote.

📚

Prueba documental

Citado en 0 publicaciones revisadas por pares sobre cromatografía, síntesis orgánica y reacciones de acoplamiento cruzado.

Descripción general

Polyphenol Oxidase (PPO, EC1.10.3.1) is widely found in the plastids of plants, fungi, and insects. It is a copper-containing oxidase that can oxidize monophenols and diphenols to produce quinones, leading to browning. It is closely related to fruit and vegetable processing, tea quality, and tissue culture. The Plant Polyphenol Oxidase (PPO) Activity Assay Kit (Catechol, Micro method) provides a simple method to detect the activity level of polyphenol oxidase (PPO) in plant tissue samples.

Detection Principle: Polyphenol oxidase (PPO) in the sample catalyzes the oxidation of catechol to produce quinones, which have a characteristic absorption peak at 410 nm. The rate of increase in absorbance at 410 nm is measured to calculate PPO activity.

P1501774
Component
48T96TStorage
P1501774A
Extraction Buffer
60 mL120 mL
2-8℃
P1501774B
ReagentⅠ
24 mL48 mL2-8℃
P1501774C
ReagentⅡ
6 mL12 mL2-8℃. Store in the dark.

Note: Before formal testing, it is recommended to perform a preliminary test with 2-3 samples expected to have significant differences.

User-Prepared Instruments and Reagents

  • Microplate reader or visible spectrophotometer (capable of measuring absorbance at 410 nm)

  • 96-well plate or micro glass cuvettes, adjustable micropipettes and tips

  • Refrigerated centrifuge, ice maker, constant temperature water bath

  • Deionized water

  • Homogenizer

Experimental Procedure

1. Reagent Preparation

Reagent Name
Reagent Preparation
Notes
Extraction Buffer
Ready-to-use; Equilibrate to room temperature before use.
Store at 4°C.
ReagentⅠ
Ready-to-use; Equilibrate to room temperature before use.
Store at 4°C.
ReagentⅡ
Ready-to-use; Equilibrate to room temperature before use.
Store at 4°C protected from light; Toxic, handle with care.

2. Sample Preparation

Note: Fresh samples are recommended. If not used immediately, samples can be stored at -80°C for one month.

2.1 Preparation of Crude Enzyme Extract

Homogenize the plant sample in ice-cold Extraction Buffer with a mass (g) to volume (mL) ratio of 1:5 to 1:10 (recommended: 0.1 g tissue + 1 mL Extraction Buffer). Centrifuge the homogenate at 8,000 g, 4°C for 10 minutes. Collect the supernatant and keep it on ice for assay.

2.2 Boiled Sample Control

Take an appropriate amount of the crude enzyme extract and heat it in a boiling water bath for 5 minutes (seal to prevent moisture loss). Cool to room temperature.

3. Assay Steps

3.1 Preheat the microplate reader or visible spectrophotometer for at least 30 minutes. Set the wavelength to 410 nm. For spectrophotometers, zero the instrument with deionized water.

3.2 Sample Measurement (Add reagents sequentially into 1.5 mL microcentrifuge tubes):

ReagentControl Tube (μL)Test Tube (μL)
Boiled Sample500
Sample (supernatant)050
ReagentⅠ
200200
ReagentⅡ
50
50

3.3 Mix thoroughly, then incubate in a 25 °C water bath for 10 min, followed immediately by incubation in a boiling water bath for 10 min. After mixing, centrifuge at 5,000 × g at 25 °C for 10 min.

3.4 Absorbance measurement: Transfer 200 μL of the supernatant to a 96-well plate and measure the absorbance at 410 nm. Record the values as Acontrol and Asample (or Atest), respectively.

Note:

  • Each test tube requires a corresponding control tube.

  • It is recommended to perform a preliminary test with 2-3 samples expected to have significant differences before the formal experiment.

  • The optimal reaction temperature for PPO may vary slightly among different samples and can be adjusted between 25-37°C.

4. Calculation of Results

Note: We provide both the derived formula and a simplified formula. They are equivalent. It is recommended to use the simplified formula in bold for final calculation.

1. Data ProcessingCalculate ΔA = Asample − Acontrol.

2. Calculation of Sample PPO Activity

Calculation based on sample weight

Unit definition: One unit of enzyme activity is defined as the amount of enzyme that causes a 0.005 change in absorbance at 410 nm per minute per gram of tissue in each mL of reaction system.

PPO (U/g) = ΔA × Vtotal‑rxn ÷ (W × Vsample ÷ Vtotal‑sample) ÷ 0.005 ÷ T = 120 × ΔA ÷ W
Calculation based on protein concentration
Unit definition: One unit of enzyme activity is defined as the amount of enzyme that causes a 0.005 change in absorbance at 410 nm per minute per milligram of tissue protein in each mL of reaction system.
PPO (U/mg prot) = ΔA × Vtotal‑rxn ÷ (Vsample × Cpr) ÷ 0.005 ÷ T = 120 × ΔA ÷ Cpr
Vtotal‑rxn: Total volume of reaction system, 0.3 mL; 
Vsample: Volume of added sample, 0.05 mL; 
Vtotal‑sample: Volume of added Extraction Buffer, 1 mL;

T: Reaction time, 10 min; 

W: Sample weight, g; 

Cpr: Protein concentration (mg/mL).

Result Presentation

Example‑1: Weigh 0.1 g blueberry, perform the assay according to the test procedure, and detect with a 96‑well plate. Obtained ΔA = Asample − Acontrol = 0.349 − 0.261 = 0.088.
Calculated by sample weight: PPO (U/g) = ΔA × Vtotal‑rxn ÷ (W × Vsample ÷ Vtotal‑sample) ÷ 0.005 ÷ T = 120 × ΔA ÷ W = 105.6 U/g. 
FAQ 
 What should I do if the measured Asample value is too high or too low? If Asample>1, the PPO activity of the sample is excessively high. Dilute the sample appropriately with Extraction Buffer and re‑measure, or reduce the sample weight for extraction. If Asample<0.02, increase the sample amount properly.

Precautions

This product is for research use only. Not for use in clinical diagnosis. For your safety and health, please wear lab coats and disposable gloves during operation.

Especificaciones

Especificaciones y pureza
BioReagent
Grado
BioReagent
Aplicación
Cell Metabolism, Enzyme activity assay
Sensibilidad
Light-sensitive
Almacenamiento y envío
Condiciones de almacenamiento de almacenamiento
Store at 2-8°C,Protected from light
Enviado en
Wet ice
Estabilidad y almacenamiento
Store at 2-8℃ long term (12 months). Store in the dark.

Documentación

📋 Hoja de datos de seguridad (SDS)

Documento completo sobre peligros, manipulación, almacenamiento y cumplimiento normativo.

<<<<<<< HEAD Descargar SDS → ======= Descargar SDS → >>>>>>> release248-p3

✅ Certificado de análisis (COA)

Datos de calidad específicos del lote. Introduzca su número de lote para obtener el COA exacto.

Buscar COA →

📊 Ficha técnica

Resumen de referencia rápida de las especificaciones y aplicaciones del producto.

Ver ficha técnica →

🔬 Hoja de especificaciones

Atributos de calidad completos y criterios de aceptación para esta calidad.

Ver hoja de especificaciones →

Datos avanzados

Certificados (CoA, COO, BSE/TSE y tabla de análisis)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Preguntas frecuentes y artículos
Calculadoras de soluciones
Reseñas

Reseñas de cliente

¿Necesita ayuda para elegir la calidad?

Nuestra guía de selección de calidades cubre la pureza, el estado del estabilizador y la idoneidad de la aplicación para todas las variantes de nuestro catálogo.

Ver la guía de calidades BioReagent →

¿Quieres que te enviemos un mensaje cuando tengamos descuentos disponibles?

Recordármelo más tarde

¡Gracias! Por favor, revisa tu bandeja de entrada de correo electrónico para confirmar.

¡Vaya! Las notificaciones están desactivadas.