Benzonase ELISA Kit

Cat. No.: B1522792
Disponibile su ordine
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. for Enzyme immunoassay(ELISA) ? ELISA grade — low-background reagents validated for enzyme immunoassays. Use to build sensitive, reproducible ELISA assays.
★
Size
Germania (EU)
USA*
Price
Qty
96T
B1522792-96T
Su ordinazione · 8–12 settimane
520,56€
Enter a quantity for the sizes you want to add.
🧪

Why this grade

BioReagent,for enzyme immunoassay(ELISA) BioReagent,per il test immunoenzimatico (ELISA) for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Store at 2-8°C,Protected from light Ships Wet ice Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Panoramica

This kit adopts the double-antibody sandwich ELISA method to detect Benzonase content in samples. Benzonase-specific antibodies are pre-coated on microplate wells. During detection, standards and samples are added separately into antibody-coated wells. Benzonase in samples binds to the immobilized antibodies. After incubation, unbound substances are washed away. HRP-labeled Benzonase detection antibody is added to form antibody-antigen-HRP antibody complexes. TMB substrate is added for color development. The color intensity is proportional to Benzonase concentration. The residual Benzonase in samples is determined by detecting color development of Benzonase standards.

Detection Range: 0.094~6 ng/mL

Quantitation Limit: 0.094 ng/mL

Limit of Detection: 0.019 ng/mL

Required Instruments

Microplate reader, microplate constant temperature shaker, vortex mixer, pipettes, plate sealing film, etc.

Reagent Preparation

1. Equilibration: Allow all required reagents to equilibrate at room temperature (25±3℃) for at least 30 minutes. Determine the number of wells needed, take out required microplate strips, and return unused strips to aluminum foil bags with desiccant. Reseal and store at 2–8℃.

2. Prepare 1× Washing Buffer: Dilute 20× Washing Buffer with deionized water at a volume ratio of 1:20 according to required volume, mix well for standby use.

3. Standard Solution Dilution (Example):

No.
Standard Concentration (ng/ml)Standard Volume (μl)Diluent Volume (μl)Total Volume (μl)Final Concentration (ng/ml)Remaining Volume (μl)
StA100020180200100170
St8100304705006250
St762502505003250
St632502505001.5250
St51.52502505000.75250
St40.752502505000.375250
St30.3752502505000.188250
St20.1882502505000.094500
St1 (Blank)//3003000300

Assay Procedure

1. Mix all reagents equilibrated to room temperature gently before use.

2. Pipette 100 μL of standard solutions (St1~St8) or test samples into corresponding wells. Seal the plate with a plate sealer, then incubate at 25±3 ℃ and 400–500 rpm for 1 hour.

3. Washing: Discard the liquid in wells. Add at least 350 μL of 1× Washing Buffer to each well (using a multichannel pipette or wash bottle). Discard residual liquid and pat the plate dry on lint-free absorbent paper. Repeat washing for 3 cycles.

(Note: Do not allow wells to dry excessively for a long time before adding Benzonase detection antibody. Improper washing may cause high CV between duplicate wells and abnormal absorbance signals.)

4. Add 100 μL of HRP-labeled Benzonase detection antibody to each well. Seal the plate and incubate at 25±3 ℃, 400–500 rpm for 30 minutes.

5. Washing: Discard the liquid in wells. Add at least 350 μL of 1× Washing Buffer to each well. Discard liquid and pat the plate dry. Repeat washing 3 times.

(Note: Avoid prolonged excessive drying of wells prior to TMB substrate addition.)

6. Color development: Add 100 μL TMB substrate to each well, and incubate for 20 minutes at room temperature in the dark.

7. Termination: Add 100 μL Stop Solution to each well, tap the plate gently to mix thoroughly and terminate the reaction.

8. Detection: Measure the absorbance at 450 nm within 10 minutes after adding Stop Solution.

Data Calculation

It is recommended to perform logarithmic transformation of concentration and fit standard curve with 4-Parameter Logistic regression model.

Table 1 Typical Standard Curve Data

Standard Concentration (ng/ml)OD Reading 1
OD Reading 2
Average OD Value
61.771.7781.774
31.0881.1531.121
1.50.7040.6580.681
0.750.3860.4170.401
0.3750.2410.2410.241
0.1880.1540.1690.161
0.0940.1160.1220.119
00.0820.0820.082

Typical Standard Curve (4PL Logistic Model)

Performance

1. Limit of Detection (LOD): 0.019 ng/mL. Calculated by substituting the average absorbance of 20 blank controls plus 2 standard deviations into the standard curve.

2. Limit of Quantitation (LOQ): 0.094 ng/mL. The lowest concentration with coefficient of variation (n=6) ≤ 20%.

3. Linearity: Standard curves are plotted with serially diluted standard solutions, with R² ≥ 0.98.

4. Repeatability: Evaluated by detecting three samples of known concentrations for 20 replicates.

5. Intermediate Precision: Evaluated by detecting three samples of known concentrations 4 times by different operators on different days.


ParameterRepeatability (n=20)
Low  Concentration 
Repeatability (n=20)
Mid  Concentration 
Repeatability (n=20)
High  Concentration 
Intermediate Precision (n=4)
Low  Concentration 
Intermediate Precision (n=4)
Mid  Concentration 
Intermediate Precision (n=4)
High  Concentration 
Mean (ng/mL)0.280.924.550.280.924.49
SD0.0350.0750.3710.0370.0780.343
CV (%)12.48.28.113.18.67.6

6. Recovery: The recovery rates of spiked Benzonase at different levels within the full detection range in biological matrix were verified.

Average Recovery (%) (n=3)Recovery Range (%)
97.689.7~102.1

Precautions

1. For research use only, not for clinical diagnosis or treatment.

2. Store reagents as labeled. Equilibrate reagents and samples to room temperature before detection.

3. Equilibrate pre-coated microplates to room temperature before opening packages. Return unused strips to sealed bags and store at 2–8℃. Seal all leftover reagents properly.

4. Mix Benzonase standard and HRP detection antibody thoroughly before use.

5. Pat washed wells dry on lint-free paper. Do not over-dry wells, which will increase CV and blank OD deviation.

6. TMB substrate should be colorless and transparent. Pale blue TMB indicates contamination and cannot be used.

7. Samples with extreme pH (<5.0 or >8.5), high salt, polysaccharide, urea, organic solvent or detergent may result in low recovery.

8. Due to complex biological matrix, use positive controls and duplicate wells to ensure accurate results.

Safety Instructions

1. Stop Solution is acidic. Operate with caution.

2. Wear proper personal protective equipment: lab coat, gloves, mask, goggles, etc.

Specifications

Specifiche e purezza
BioReagent,for enzyme immunoassay(ELISA)
Grado
BioReagent, per il test immunoenzimatico (ELISA)
Applicazione
ELISA
Campo di rilevamento
0.094~6 ng/ml
Metodo di rilevamento
Sandwich ELISA
Detection instrument
Microplate reader
Detection wavelength
450 nm
Stoccaggio e spedizione
Condizioni di conservazione di stoccaggio
Store at 2-8°C,Protected from light
Spedito in
Wet ice
Stabilità e conservazione
Each component has a shelf life of 12 months under corresponding storage conditions.
Contents & Storage
Item No.AppearanceComponents96 TStorage
B1522792ALiquidBenzonase Standard1000 ng/ml, 0.8 ml, 1 Vial2-8℃
B1522792BLiquidBenzonase Detection Antibody (HRP labeled)12 ml, 1 Vial2-8℃. Store in the dark.
B1522792CLiquidTMB Substrate12 ml, 1 Vial2-8℃. Store in the dark.
B1522792DLiquidStop Solution12 ml, 1 Vial2-8℃
B1522792ELiquidSample Diluent50 ml, 1 Vial2-8℃
B1522792FLiquidWash Buffer (20×)50 ml, 1 Vial2-8℃
B1522792G—Pre-coated Assay Plate96 wells,1 Plate2-8℃

Documentazione

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Domande frequenti e articoli
Calcolatori di soluzioni
Recensioni

Recensioni dei clienti

Need help choosing the grade?

Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.

View BioReagent grade guide → View for Enzyme immunoassay(ELISA) grade guide →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.