Technical Articles: Reagent Chemistry, Synthesis & Bioscience Guides

Recombinant CD45R Antibody (AF555): Usage & Protocol Guide

Recombinant CD45R Antibody (AF555) is an AF555-conjugated recombinant antibody targeting the CD45R isoform, designed for reliable detection and immunophenotyping of lymphocyte subpopulations in flow cytometry and immunofluorescence applications.

Fluorescent Label
AF555 (Alexa Fluor 555 equivalent)
Antibody Format
Recombinant antibody (derived from Ab219620Z parent clone)
Target Antigen
CD45R (a restricted isoform of CD45/PTPRC)
Primary Applications
Flow cytometry, immunofluorescence, immunophenotyping
Parent Unlabeled Antibody
Ab219620Z

Product Overview and Target Background

Recombinant CD45R Antibody (AF555) (Ab223841) is a fluorescently labeled recombinant antibody directed against CD45R, a restricted isoform of the CD45 family of protein tyrosine phosphatases (also known as PTPRC, Leukocyte Common Antigen). CD45 is a transmembrane glycoprotein expressed exclusively on hematopoietic cells and plays a critical role in regulating antigen receptor signaling in lymphocytes. The CD45R isoform (also referred to as CD45RA in many contexts) is characteristically expressed on naive T cells, B cells, and certain natural killer (NK) cell subsets, making it an important marker for distinguishing naive from memory lymphocyte populations.

The AF555 fluorescent conjugate provides excitation at approximately 555 nm and emission at approximately 570 nm, making it compatible with standard 532 nm or 561 nm laser lines commonly found on modern flow cytometers. The recombinant format of this antibody ensures batch-to-batch consistency, reduced lot-to-lot variation, and improved specificity compared to conventional hybridoma-derived antibodies. The unlabeled parent antibody for this product is Ab219620Z.

Optimization, Controls, and Troubleshooting

Antibody Titration: Always titrate Recombinant CD45R Antibody (AF555) before use. Excessive antibody concentration leads to high background fluorescence, while insufficient amounts reduce signal intensity and sensitivity. A checkerboard titration across a 2–3 log concentration range is recommended to identify the optimal signal-to-noise ratio.

Essential Controls:

  • Isotype control: Use an AF555-conjugated recombinant isotype control antibody of the same subclass to assess non-specific background staining.
  • FMO (Fluorescence Minus One) control: Include an FMO control for the AF555 channel in multicolor panels to accurately set gating boundaries.
  • Positive control: Use a cell type known to express CD45R (e.g., human peripheral blood naive T cells or B cells) as a positive control in each experiment.
  • Negative control: Use a CD45R-negative cell line or depleted cell population to assess background.

Troubleshooting Common Issues:

  • High background: Increase wash stringency, reduce antibody concentration, or extend Fc blocking time. Ensure cells are kept at 4°C throughout staining to minimize non-specific binding.
  • Low or absent signal: Verify laser and filter configuration on the cytometer. Check that the antibody has been stored correctly (see Storage and Handling section). Confirm target cell population expresses CD45R.
  • Spectral spillover: In multicolor panels, generate single-color compensation controls and use the FMO strategy. AF555 may show spillover into PE or PE-CF594 channels; adjust panel design accordingly.

Storage, Handling, and Stability

Proper storage of Recombinant CD45R Antibody (AF555) is critical to maintaining fluorescent label integrity and antibody activity. Follow the guidelines below:

  • Storage temperature: Store at 2–8°C (refrigerated). Do not freeze AF555-conjugated antibodies, as freeze-thaw cycles can disrupt the fluorochrome and cause protein aggregation.
  • Light protection: AF555 is a light-sensitive fluorochrome. Always store and handle the antibody protected from direct light exposure. Use amber tubes or foil wrapping when possible.
  • Aliquoting: For long-term use, consider aliquoting the product upon receipt into single-use volumes to minimize repeated opening of the stock vial.
  • Contamination prevention: Use aseptic technique when handling the antibody. Do not return unused portions to the original vial.
  • Expiry: Refer to the product label for the specific expiration date. Discard if the solution appears turbid, discolored, or if precipitation is observed.

For shipping and delivery conditions, refer to Aladdin Scientific's shipping and delivery guidelines. Antibodies labeled with AF555 are typically shipped with a cold pack to maintain the 2–8°C temperature range during transit.

Frequently asked questions

What laser and filter settings should I use for AF555 on my flow cytometer?

AF555 is optimally excited by a 532 nm or 561 nm laser. The recommended emission filter is typically a 575/25 nm or 586/15 nm bandpass filter, though exact filter selection may vary by instrument. Consult your cytometer's configuration guide and always use single-color compensation controls to manage spectral spillover in multicolor panels.

Can I use Recombinant CD45R Antibody (AF555) for intracellular staining?

CD45R is a cell surface antigen, and Recombinant CD45R Antibody (AF555) is intended for surface staining protocols. Intracellular staining is not the primary application for this antibody. If you are co-staining with intracellular targets, perform the surface staining with Ab223841 first, then fix and permeabilize cells before applying intracellular antibodies.

What is the difference between the labeled Ab223841 and the parent antibody Ab219620Z?

Ab219620Z is the unlabeled (unconjugated) parent recombinant anti-CD45R antibody. Recombinant CD45R Antibody (AF555) (Ab223841) is derived from this same recombinant clone but is directly conjugated to the AF555 fluorochrome, enabling direct detection without the need for a secondary antibody. The direct conjugate format simplifies multicolor panel design and reduces overall staining time.

How should I determine the optimal working dilution for Ab223841?

The optimal working dilution must be determined empirically by titration for each specific cell type, sample matrix, and instrument setup. It is recommended to test a range of concentrations (e.g., 0.1 µg/mL to 10 µg/mL or as guided by the product datasheet) using a known CD45R-positive cell population and select the concentration that provides the highest specific signal with the lowest background.

Is Recombinant CD45R Antibody (AF555) suitable for use with fixed cells?
Recombinant CD45R Antibody (AF555) can be used with lightly fixed cells (e.g., 1–4% paraformaldehyde) for surface CD45R detection, which is particularly useful when working with biosafety level 2 or higher samples. However, fixation may alter epitope accessibility and fluorochrome brightness. If fixation is required, titrate and validate the antibody on fixed cells separately, and note that AF555 fluorescence intensity may be reduced after fixation.

References

  1. Aladdin Scientific Product Information: Recombinant CD45R Antibody (AF555), SKU Ab223841. Aladdin Scientific internal product documentation.
  2. Hermiston ML, Xu Z, Weiss A. CD45: A Critical Regulator of Signaling Thresholds in Immune Cells. Annual Review of Immunology. 2003;21:107–137.
  3. Terstappen LW, Huang S, Picker LJ. Flow cytometric assessment of human T-cell differentiation in thymus and bone marrow through four stages of maturation. Blood. 1992;79(3):666–677.

Products are supplied for research and development use only. Not for use in humans, animals, diagnosis, or therapy.

Categories: Technical Articles: Reagent Chemistry, Synthesis & Bioscience Guides

Products are supplied for research and development use only. Not for use in humans, animals, diagnosis, or therapy.

Cite this article

Aladdin Scientific. "Recombinant CD45R Antibody (AF555): Usage & Protocol Guide" Aladdin Knowledge Base, updated 28 nov 2026. https://www.aladdinsci.com/eu_it/faqs/recombinant-cd45r-antibody-af555-usage-protocol-guide-en.html
Was this article helpful? Yes No 1 out of 3 found this helpful

Desidera che le inviamo un messaggio quando avremo sconti disponibili?

Ricordamelo più tardi

Grazie! Controlli la sua casella di posta per confermare.

Ops! Le notifiche sono disabilitate.