Glucose detection kit (GOD-POD microplate method)

Cat. No.: A1371397
Disponibile su ordine
QUALITÀ & PUREZZA BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
★
Dimensione
Germania (EU)
USA*
Prezzo
Qtà
200T
A1371397-200T
Su ordinazione · 8–12 settimane
34,62€
500T
A1371397-500T
Su ordinazione · 8–12 settimane
51,98€
Enter a quantity for the sizes you want to add.

Panoramica

Glucose (Glucose, Dextrose, Glu), also known as corn sugar, is the most widely distributed and most important monosaccharide in nature. It is a polyhydroxy aldehyde with the chemical formula C₆H₁₂O₆ and a molecular weight of 180.16. Enzymatic methods are commonly used for glucose determination in biochemical assays, with the glucose oxidase method and hexokinase method being the most frequently used. These methods are characterized by high sensitivity, accuracy, and precision; mild reaction conditions; specificity for glucose without interference from other sugars or reducing substances; simple operation; and suitability for automated analyzers.

The Glucose Assay Kit (GOD-POD Microplate Method), also known as the Glucose Oxidase Method or Glucose Oxidase-Peroxidase Coupling Method, operates on the following principle: Under the catalysis of glucose oxidase, glucose is oxidized to gluconic acid, consuming oxygen from the solution and producing hydrogen peroxide. The hydrogen peroxide then reacts with a chromogenic substrate to form a red quinone compound. In the initial reaction phase, the amount of hydrogen peroxide produced is proportional to the glucose concentration, which can be detected using a microplate reader at 505 nm.

This kit can be used for the quantitative determination of glucose content in samples such as human or animal serum, plasma, cerebrospinal fluid, cells, and tissues. However, it is not suitable for direct detection of glucose in urine. The concentration of the Glu Standard provided is 5 mmol/L (equivalent to 90 mg/dL). This kit is intended for research use only and is not suitable for clinical diagnosis or other purposes.

Before use, mix the Phenol Reagent and Enzyme Reagent at a 1:1 ratio to prepare the GOD-POD Working Solution. Store at 4°C.

Reagents, consumables and Equipments not provided

  • Microplate reader

  • Centrifuge tubes or 96-well plates, homogenizer, centrifuge, water bath or incubator

  • Physiological saline or PBS

Procedure (For Reference Only)

1. Sample Preparation

1.1 Serum, Plasma, Cerebrospinal Fluid Samples

Separate serum or plasma from the test sample should be non-hemolyzed. Measure directly. If the concentration exceeds the linear range (30 mmol/L), dilute with physiological saline or PBS before measurement.

1.2 Cell Samples

(1) Take an appropriate number of cells (generally recommended > 10⁶ cells). Centrifuge at 1000 g for 10 minutes. Discard the supernatant, retaining the pellet.

(2) Wash 1-2 times with PBS or physiological saline. Centrifuge at 1000 g for 10 minutes. Discard the supernatant, retaining the pellet.

(3) Add 200–300 μL of PBS or physiological saline for homogenization. Disrupt cells by sonication in an ice bath (300 W power, 3-5 seconds each time with 30-second intervals, repeated 3-5 times). Manual homogenization can also be used. The prepared homogenate should not be centrifuged. Alternatively, add 1-2% Triton X-100 and incubate in an ice bath for 30–60 minutes. The prepared lysate should not be centrifuged.

1.3 Tissue Samples

Accurately weigh an appropriate amount of tissue sample. Add physiological saline or PBS at a ratio of sample weight (g): saline/PBS (mL) = 1:9. Homogenize manually or mechanically in an ice bath. Centrifuge at 2500–3000 g for 10 minutes and collect the supernatant.

2. Sample Addition

Take a 96-well plate and set up Blank, Standard, and Assay wells according to the table below. Add the various solutions sequentially, mix thoroughly, and incubate in a 37°C water bath or 45°C incubator for 15 minutes.

Addition (μL)Blank WellStandard WellAssay Well
ddH₂O2.5——
Glu Standard (5mmol/L)—2.5—
Sample to be tested——2.5
GOD-POD Working Solution250250250

3. Measurement

After cooling, measure the absorbance at 505 nm. Zero the reader with the Blank well. Read the absorbance of the Standard and Assay wells, recorded as A<sub>Standard</sub> and A<sub>Assay</sub>, respectively.

4. Calculation

Glu (mmol/L) = Glu (mmol/L) = AAssay / AStandard × 5 

Glu (mg/L) = AAssay / AStandard × 900

Reference Interval:

Healthy adults, fasting blood glucose: 3.9–6.1 mmol/L (70–110 mg/dL)

Note: Glu Standard (5mmol/L) = 90 mg/dL = 900 mg/L

Performance Characteristics

AppearanceColorless to light yellow clear liquid
Linear Range0–30 mmol/L, r > 0.990
Coefficient of VariationIntra-assay < 2-5%, Inter-assay < 5%
Blank Absorbance< 0.2 (1 cm light path)
Stability6 months (sealed)

Notes

  1. The prepared GOD-POD Working Solution should be stored at 4°C protected from light and is stable for 1 week. Avoid repeated freeze-thaw cycles of refrigerated reagents to prevent inactivation or reduced efficiency.

  2. Use serum or plasma anticoagulated with potassium oxalate-sodium fluoride (which inhibits glucose breakdown) for measurement. This method can be directly used to detect glucose content in cerebrospinal fluid. If the test samples cannot be measured promptly, store them at 2-8°C; they are stable for up to 3 days.

  3. Although this method is often used for quantitative determination of urine glucose, it cannot be measured directly. First, perform a semi-quantitative test on the urine sample using the Benedict's method. Based on the approximate content obtained, dilute the urine sample with distilled water to bring the glucose concentration below 3 mg/mL. Then perform the assay, multiplying the result by the dilution factor. Untreated urine contains high concentrations of reducing substances like uric acid that can interfere with the peroxidase reaction, potentially causing falsely low results.

  4. Low-concentration samples may also turn red over extended periods. Therefore, measure promptly after the 15-minute incubation; avoid prolonged delays.

  5. If the microplate reader is not zeroed, the blank reference range is typically between 0.04 and 0.09, and the 5 mmol/L standard reference range is typically between 0.25 and 0.45. Reference ranges may vary depending on factors such as instrument and operating method.

  6. The detection limit of this kit is 0.1 mmol/L, and the upper limit is 30 mmol/L. Visually, concentrations ≤ 0.6 mmol/L appear almost colorless, concentrations around 0.7 mmol/L show a faint red color, and concentrations ≥ 2.5 mmol/L show a distinct red color. Generally, results near the upper limit are more accurate than those near the lower limit.

  7. The linear range of this method reaches up to 30 mmol/L. If the sample glucose concentration is too high, results may be falsely low. Dilute the sample with physiological saline or PBS and re-assay, multiplying the result by the dilution factor.

  8. Use the reagents as soon as possible after opening to avoid affecting subsequent experimental results.

  9. For your safety and health, please wear a lab coat and disposable gloves during operation.

Specifiche

Specifiche e purezza
BioReagent
Grado
BioReagent
Applicazione
Biochemical Testing
Tipo di campione
Cellula, Liquido cerebrospinale, Plasma, Siero, Tessuti animali e vegetali
Metodo di rilevamento
Colorimetric Method
Detection instrument
Microplate reader
Detection wavelength
505nm
Sensibilità
Light-sensitive
Stoccaggio e spedizione
Condizioni di conservazione di stoccaggio
Store at 2-8°C,Protected from light,Room temperature,Store at -20°C,Avoid repeated freezing and thawing
Spedito in
Normal,Wet ice,Ice chest + Ice pads
Stabilità e conservazione
Each component has a shelf life of 1 year under corresponding storage conditions.
Contents & Storage
Storage and Transport Unit Item No.Storage and Transport Unit NameComponent No.Component NameAppearance200 T500 TStorage
A1371397NTGlucose Colorimetric Detection Kit t (GOD-POD Microplate Method)(RT Components)A1371397APhenol ReagentLiquid25mL65mLRoom temperature. Store in the dark


A1371397DddH₂OLiquid1mL1mLRoom temperature
A1371397WTGlucose Colorimetric Detection Kit t (GOD-POD Microplate Method)(2-8℃ Components)A1371397CGlu Standard (5mmol/L)Liquid1mL1mL2-8℃
A1371397DTGlucose Colorimetric Detection Kit t (GOD-POD Microplate Method)(2-20℃ Components)A1371397BEnzyme ReagentLiquid25mL65mL-20℃.Avoid freeze-thaw cycle.
Note:
Each component is individually packaged according to its storage temperature (RT/2-8℃/-20℃) upon shipment, with differentiated temperature‑controlled transportation to guarantee product performance. Orders containing materials requiring multiple temperature zones may be delivered in separate batches; please refer to the actual received goods. Upon receipt, store components separately at the temperatures specified in the component list. The shelf‑life is 12 months from the date of manufacture.

Dati avanzati

Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

23 results found

Lot NumberCertificate TypeDataOggetto
K2612405K2612405Certificate of AnalysisNov 12, 2026 A1371397
K2612404K2612404Certificate of AnalysisNov 12, 2026 A1371397
J2623502J2623502Certificate of AnalysisOct 23, 2026 A1371397
J2617014J2617014Certificate of AnalysisOct 17, 2026 A1371397
J2610170J2610170Certificate of AnalysisOct 10, 2026 A1371397
J2609465J2609465Certificate of AnalysisOct 09, 2026 A1371397
I2622339I2622339Certificate of AnalysisSep 22, 2026 A1371397
ZJ26F0939123ZJ26F0939123Certificate of AnalysisSep 10, 2026 A1371397
ZJ26F0939122ZJ26F0939122Certificate of AnalysisSep 10, 2026 A1371397
I2604225I2604225Certificate of AnalysisSep 04, 2026 A1371397
G2615281G2615281Certificate of AnalysisJul 15, 2026 A1371397
G2608555G2608555Certificate of AnalysisJul 08, 2026 A1371397
F2624399F2624399Certificate of AnalysisJun 24, 2026 A1371397
F2611341F2611341Certificate of AnalysisJun 11, 2026 A1371397
ZJ25F0724703ZJ25F0724703Certificate of AnalysisMay 19, 2026 A1371397
ZJ25F0724704ZJ25F0724704Certificate of AnalysisMay 19, 2026 A1371397
ZJ25F0724705ZJ25F0724705Certificate of AnalysisMay 19, 2026 A1371397
ZJ25F0724706ZJ25F0724706Certificate of AnalysisMay 19, 2026 A1371397
D2617620D2617620Certificate of AnalysisApr 17, 2026 A1371397
D2610581D2610581Certificate of AnalysisApr 10, 2026 A1371397
C2625698C2625698Certificate of AnalysisMar 25, 2026 A1371397
ZJ26F0333277ZJ26F0333277Certificate of AnalysisMar 19, 2026 A1371397
K2507197K2507197Certificate of AnalysisNov 07, 2025 A1371397
Domande frequenti e articoli
Calcolatori di soluzioni
Recensioni

Recensioni dei clienti

Hai bisogno di aiuto per scegliere la qualità?

La nostra guida alla selezione delle qualità copre purezza, stato dello stabilizzatore e idoneità all'applicazione per tutte le varianti del nostro catalogo.

Visualizza la guida alle qualità BioReagent →

Desidera che le inviamo un messaggio quando avremo sconti disponibili?

Ricordamelo più tardi

Grazie! Controlli la sua casella di posta per confermare.

Ops! Le notifiche sono disabilitate.