Methylene Blue Staining Solution (2%) - BioReagent

CAS: 7220-79-3 Cat. No.: M1528810 Formula: C₁₆H₂₄ClN₃O₃S Peso molecolare: 373.9 Beilstein Registry Number: 3599847 Numero EC: 615-731-6
Disponibile su ordine
QUALITÀ & PUREZZA BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. Biological Stain ? Biological stain grade — dyes characterized for staining cells and tissues. Use in histology and microscopy where staining consistency matters. 2% in water
Storage
Protected from light,Room temperature
Shipped In
Normal
Application
Tissue Staining
★
Dimensione
Germania (EU)
USA*
Prezzo
Qtà
100ml
M1528810-100ml
Su ordinazione · 8–12 settimane
32,02€
500ml
M1528810-500ml
Su ordinazione · 8–12 settimane
86,69€
Enter a quantity for the sizes you want to add.

Panoramica

Methylene blue, also known as methylthioninium chloride, basic blue 9, etc., has the molecular formula C₁₆H₂₄ClN₃O₃S (hydrated form), a molecular weight of 373.9, and a CAS number of 7220-79-3.

Methylene blue staining solution is commonly used for staining silk, paper, bacteria, cells, etc. Because it is easily oxidized, staining results are not suitable for long-term storage.

Procedure (for reference only):

1. Sample Processing

① Paraffin sections

Deparaffinize in xylene for 5–10 min.

Replace with fresh xylene and deparaffinize again for 5–10 min.

Immerse in anhydrous ethanol for 5 min.

Rinse in distilled water for 2 min.

② Frozen sections

Rinse in distilled water for 2 min.

③ Cultured cells

Fix with 4% paraformaldehyde for at least 10 min.

Wash with distilled water for 2 min.

Replace with fresh distilled water and wash again for 2 min.

2. Methylene Blue Staining

Stain with Methylene Blue Staining Solution (2%) for 3–10 min (the time can be adjusted according to the staining results and requirements).

Wash thoroughly with distilled water or tap water, then observe and photograph.


Staining Results:

Tissues or cells: blue

Precautions:

1.When using this reagent for the first time, it is recommended to perform a preliminary experiment with 1–2 samples.

2.For your safety and health, please wear a lab coat and disposable gloves during operation.

3.This product is for research use only and must not be used for any other purposes.

Specifiche

Specifiche e purezza
BioReagent, Biological Stain, 2% in water
Stabilità e conservazione
Store at RT long term (12 months). Store in the dark.
Condizioni di conservazione di stoccaggio
Protected from light,Room temperature
Spedito in
Normal
Grado
Biological Stain, BioReagent
Product Line
Prodotti biologici
Nomi e identificatori
Isomeri SMILES
CN(C)C1=CC2=C(C=C1)N=C3C=CC(=[N+](C)C)C=C3S2.O.O.O.[Cl-]
WGK Germania
2
Peso molecolare
373.9
Beilstein
3599847
Reaxys
16692608
Reaxys-RN_link_address
https://www.reaxys.com/reaxys/secured/hopinto.do?context=S&query=IDE.XRN=16692608&ln=

Dati avanzati

Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Proprietà chimiche e fisiche
SensibilitàLight-sensitive
Punto di fusione (°C)235°C
Sicurezza e pericoli (GHS)
Pictogrammi
GHS08,   GHS07
Segnale
Warning
Indicazioni di pericolo

H315:Causes skin irritation

H319:Causes serious eye irritation

H335:May cause respiratory irritation

H373:May causes damage to organs through prolonged or repeated exposure

H302:Harmful if swallowed

Precauzioni

P261:Avoid breathing dust/fume/gas/mist/vapors/spray.

P305+P351+P338:IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do - continue rinsing.

P280:Wear protective gloves/protective clothing/eye protection/face protection.

P302+P352:IF ON SKIN: wash with plenty of water.

P321:Specific treatment (see ... on this label).

P405:Store locked up.

P501:Dispose of contents/container to an approved waste disposal plant.

P264:Wash hands [and …] thoroughly after handling.

P260:Do not breathe dust/fume/gas/mist/vapors/spray.

P271:Use only outdoors or in a well-ventilated area.

P270:Do not eat, drink or smoke when using this product.

P304+P340:IF INHALED: Remove person to fresh air and keep comfortable for breathing.

P403+P233:Store in a well-ventilated place. Keep container tightly closed.

P362+P364:Take off contaminated clothing and wash it before reuse.

P330:Rinse mouth.

P264+P265:Wash hands [and …] thoroughly after handling. Do not touch eyes.

P301+P317:IF SWALLOWED: Get medical help.

P337+P317:If eye irritation persists: Get medical help.

P332+P317:If skin irritation occurs: Get medical help.

P319:Get medical help if you feel unwell.

WGK Germania
2
Reaxys
16692608
Reaxys-RN_link_address
https://www.reaxys.com/reaxys/secured/hopinto.do?context=S&query=IDE.XRN=16692608&ln=
Calcolatori di soluzioni
Recensioni

Recensioni dei clienti

Application Protocols

Formal, item-validated protocols are not provided in the product data. The following are general literature/good-practice outlines for a 2% stock used as a stain. Adjust to your samples and safety rules.

  • Simple cell/bacteria stain (brightfield):

    1. Prepare a working solution by diluting the 2% stock to 0.02–0.2% with water or PBS. 2) Apply to fixed smear or wet mount for 30 s–3 min. 3) Rinse gently with water/buffer. 4) Air-dry and observe.
  • Agarose gel DNA stain:

    1. Post-stain: Dilute stock to ~0.02–0.05% in TAE/TBE. 2) Immerse gel 20–60 min with gentle agitation. 3) Destain in buffer/water until background subsides; image under white light or blue-light transilluminator (reflectance).
  • Redox indicator demo:

    1. Add a few drops of diluted MB to a reducing mixture (e.g., glucose + base). 2) Observe loss of blue color; upon shaking in air, color returns as MB is re-oxidized.
  • Tissue sections (general):

    1. Rinse section. 2) Stain with diluted MB for 1–5 min. 3) Rinse and differentiate briefly if needed. 4) Mount in aqueous medium.

Notes:

  • Optimize dilution, contact time, and rinses to balance intensity and background.
  • Filter working solutions to remove particulates that contribute to speckling.
  • Document lot number, dilution, buffer, and exposure times for reproducibility.

These are general guidelines, not item-specific validated protocols.

Biological Roles

This section summarizes literature context for the active dye methylene blue; it does not describe medical/clinical use.

  • Charge-driven interactions: As a cationic phenothiazinium dye, methylene blue associates with negatively charged biomolecules (nucleic acids, acidic polysaccharides) and cell surfaces, enabling contrast in light microscopy.

  • Nucleic acid affinity (literature): Intercalative and electrostatic interactions with DNA/RNA yield visible staining under white light. Binding strength and spectral properties depend on ionic strength, pH, and crowding agents.

  • Protein/tissue interactions: Prefers acidic tissue components; often accentuates nuclei and certain granules. Limited penetration into highly hydrophobic domains without surfactants or permeabilization.

  • Redox activity: Engages in reversible redox cycling (MB ↔ leucomethylene blue), which can report on cellular reducing environments. This underlies its use as a redox indicator in microbiology and biochemical assays.

  • Photochemical behavior: Upon illumination in the presence of oxygen, acts as a photosensitizer capable of generating reactive oxygen species (e.g., singlet oxygen). In biological contexts, this can lead to photobleaching of the dye and photo-oxidation of nearby biomolecules (hence light protection is recommended during storage).

  • Aggregation: Exhibits concentration-dependent dimerization/aggregation in aqueous media, altering absorption maxima and apparent staining intensity (literature). Dilution and ionic composition can tune monomer–dimer equilibria for consistent staining outcomes.

Note: The above are general literature characteristics of methylene blue and may vary with formulation; consult your own controls for your specific matrix and protocol.

Buffer Applications

This product is a staining solution, not a buffering reagent.

  • Buffer function: Not applicable — the solution is intended to deliver dye, not to control pH. Any buffering capacity present is not specified for this item; refer to CoA/Spec Sheet.

Practical guidance:

  • If your workflow requires pH control or ionic strength, dilute the 2% solution into an appropriate buffer (e.g., PBS, Tris-buffered saline) immediately before use to prepare a working solution.
  • For gel staining, rinsing/destaining in the same buffer used for electrophoresis (e.g., TAE/TBE) often reduces background.
  • Record the final buffer composition and dilution factor to maintain reproducibility across runs.
Green Alternatives

Consider environmental, safety, and waste aspects when choosing stains and nucleic acid visualization methods.

  • Why consider alternatives: Methylene blue is aqueous and non-volatile, which is positive; however, it is a persistent colorant that can visibly contaminate aqueous waste streams and plastics. It is also redox-active and can impact aquatic assays.

Comparison (literature/general; suitability depends on assay):

  • Aqueous basic stains

    • Methylene blue (this item): Aqueous, minimal solvent hazard; moderate sensitivity; strong visible color; can photofade; background can be managed with rinses.
    • Toluidine blue O: Similar handling; different metachromasia for polysaccharides; may offer better contrast for certain tissues.
    • Crystal violet/safranin (often alcoholic): Higher hazard due to solvent and mutagenicity concerns (crystal violet); avoid where possible.
  • Nucleic acid gel stains

    • Methylene blue: Non-fluorescent, view under white light; lower sensitivity; fully aqueous handling.
    • SYBR Safe/GelGreen: Higher sensitivity under blue/UV light; lower mutagenicity claims by vendors; require fluorescence imagers; cost/tradeoffs.
    • Ethidium bromide: Very sensitive but higher hazard classification; typically avoided in green labs.
  • Redox indicators

    • Resazurin (alamarBlue): Fluorescent readouts, often lower dye mass required; needs fluorimetry.
    • Janus green B: Alternative mitochondrial/redox stain with its own hazard profile.

Waste minimization tips:

  • Use smallest effective volumes; adopt re-usable, closed staining trays; implement dye capture (activated carbon) before disposal per local regulations.
Pharmaceutical Uses

No pharmaceutical or clinical applications are claimed for this product. It is supplied strictly for research and laboratory use.

Contextual/literature notes (non-claims):

  • Methylene blue (methylthioninium chloride) appears in various pharmacopeial monographs for specific quality attributes when intended for medicinal use. Those specifications are distinct from research-grade materials and are not implied here.
  • In laboratory manufacturing contexts, methylene blue is sometimes used as a colorant/marker in diagnostics development, leak testing, and device wettability studies due to its intense visible color and water solubility.

This product is a BioReagent-grade 2% solution and should not be used for any human or veterinary applications. For any regulated diagnostic or GMP manufacturing, obtain grade-appropriate materials and documentation (e.g., USP/EP grade, DMF, or CQ documentation) and validate suitability.

Physical Properties

Item-specific physical specifications for this 2% solution are not provided in the product data.

  • Appearance (item-specific): Not specified for this item; refer to CoA/Spec Sheet.
  • Concentration: 2% (w/v) as named; exact mass/volume basis and tolerances — Not specified for this item; refer to CoA/Spec Sheet.
  • pH (as supplied): Not specified for this item; refer to CoA/Spec Sheet.
  • Density (solution): Not specified for this item; refer to CoA/Spec Sheet.
  • Stability/light sensitivity: See Safety & Handling and Storage; protect from strong light as a general best practice for phenothiazinium dyes.

Literature/general properties of the active dye (methylene blue) — for context only:

  • Solubility: Highly soluble in water; soluble in alcohol; limited solubility in nonpolar solvents (literature).
  • UV–Vis λmax (water, literature): ~660–668 nm with prominent absorption in the red/near-IR; an additional band near ~610 nm depending on conditions. Exact spectra are pH/ionic-strength dependent.
  • Redox behavior: Reversible redox couple (MB/Methylene White), enabling use as a redox indicator; colorless in reduced form (literature).
  • LogP (literature, cationic dye): Effectively low apparent partitioning into nonpolar phases due to charge; precise values vary with ion pairing and medium.
  • pKa: Not typically expressed as a simple acid–base pKa due to delocalized cation; spectral properties depend on aggregation and ionic strength (literature).

Note: Use the specific batch CoA/Spec Sheet for any quantitative property needed for regulated/validated methods.

Quality and Grades
  • Supplied grade: BioReagent — intended for laboratory research and life-science workflows. This designation generally indicates control of common biological contaminants and consistency suitable for staining/imaging and routine biochemical procedures. It is not a clinical/diagnostic grade and is not intended for therapeutic use.

  • What BioReagent typically implies (general):

    • Sourced and processed to minimize bioburden and interfering residues in standard bioassays.
    • Appropriate performance in typical staining applications (e.g., microscopy, gel staining) when used as directed.
    • Does not imply specific trace-metal, UV-cutoff, or chromatography absorbance specifications unless stated.
  • This item (2% solution) — specification notes:

    • Exact dye salt form, stabilizers, and pH range — Not specified for this item; refer to CoA/Spec Sheet.
    • Lot-specific performance characteristics (e.g., background in gels, microscopy clarity) should be verified in your workflow; retain lot numbers for reproducibility.
  • Verification & documentation:

    • For regulated work, request the CoA/Spec Sheet for concentration tolerances and any available test results.
    • Record-keeping: note SKU, lot, receipt date, opening date, and any in-lab dilutions made.
  • Related grades (context, not supplied here): Analytical Reagent (AR), HPLC, ACS, or USP/NF grades have different intents and control criteria; choose based on assay requirements and regulatory context.

Reaction and Applications

Focused on laboratory staining and analytical uses rather than synthetic reactions.

  • Microscopy/simple staining (general):

    • Rapid coloration of cells and tissues, highlighting nuclei and acidic components due to the dye’s cationic nature.
    • Common for teaching labs, wet mounts, and quick morphology checks.
  • Microbiology (general):

    • Simple stain for bacteria; can serve as a counterstain in certain differential methods (procedure-dependent).
    • Acts as a redox indicator: turns colorless upon reduction ("methylene white") and re-oxidizes to blue with air exposure — useful in anaerobic testing demonstrations.
  • Nucleic acid/gel staining (literature practice):

    • Stains DNA/RNA in agarose gels as a non-fluorescent alternative to intercalating fluorophores. Sensitivity is lower than fluorescent dyes; extended staining and destaining steps enhance band contrast.
  • Photochemical/analytical roles (literature):

    • Photosensitizer for generating singlet oxygen in educational demos; absorbance near 660–668 nm enables photoredox experiments. For quantitative photochemistry, defined dye molarity is preferred; if using this 2% solution, determine molarity spectrophotometrically.

Practical tips:

  • Filter through 0.22–0.45 µm if particulate background is observed (use syringe filter; discard first drops).
  • For consistent results, standardize contact time and rinse schedules; record microscope settings for reproducibility.
  • Avoid strong reducing agents in the workflow unless intentional (they will bleach the stain and alter results).
Reaction Conditions

General literature guidance for uses of methylene blue (active dye); adjust to your system and consult primary references.

  • Photochemical oxidations (literature):

    • Solvent: Water, alcohols, or mixed aqueous buffers; oxygen or air as terminal oxidant.
    • Light: Visible light centered ~630–670 nm (LED arrays or broad-spectrum lamps). Protect from overheating.
    • Catalyst loading: µM–mM ranges depending on substrate and path length; too high leads to self-quenching/aggregation.
    • Notes: Maintain oxygenation (stirring, O2 bubbling); monitor by UV–Vis to observe photobleaching/recovery.
  • Redox indicator assays (literature):

    • Conditions: Reducing environment (e.g., glucose + alkaline conditions with suitable mediator) leads to leuco form; re-oxidation by air restores color.
    • Readout: Visual (blue ↔ colorless) or spectrophotometric at ~660–668 nm.
  • MBAS assay for anionic surfactants (literature):

    • pH-controlled ion-pair formation; extraction into immiscible organic phase and spectrophotometry at ~650–660 nm.
    • Requires meticulous glassware cleaning to avoid background.
  • Gel staining (laboratory practice):

    • Stain: 0.02–0.1% MB working solutions often used; immersion 15–60 min.
    • Destain: Water or electrophoresis buffer until bands contrast adequately.

Note: The above are general guidance ranges from literature/typical practice and are not item-specific specifications. Optimize empirically for your substrate, path length, and instrumentation.

Safety and Handling

Authoritative hazard classification for this specific 2% solution is not provided in the product data.

  • GHS classification/Pictograms/Signal word (item-specific): Not specified for this item; refer to the SDS for definitive information.
  • General hazards (literature/typical for methylene blue solutions): May cause eye and skin irritation; can cause persistent staining of skin, labware, and surfaces. Harmful if swallowed in significant amounts. Avoid inhalation of aerosols/mists. Redox-active; may be decolorized by reducing agents.
  • PPE (good laboratory practice):
    • Wear lab coat, nitrile gloves, and safety glasses or face shield when splashing is possible.
    • Work on absorbent pads to minimize staining; designate dye-handling area.
  • Handling tips:
    • Prevent contact with porous materials and instrument housings; wipe spills promptly with water/detergent.
    • Avoid contact with strong oxidizers and with strong reducing agents (will bleach the dye and may generate byproducts).
    • Minimize light exposure during long experiments to limit photofading.
  • First aid overview (general):
    • Skin: Wash with soap and water. Remove contaminated clothing.
    • Eyes: Rinse cautiously with water for several minutes; remove contact lenses if present and easy to do; continue rinsing. Seek medical attention if irritation persists.
    • Ingestion/Inhalation: Seek medical advice; provide SDS to responders.
  • Spill response: Contain with inert absorbent; clean with aqueous detergent. Collect waste as aqueous dye waste per institutional and local regulations.

Always consult the product’s SDS for official hazard, exposure limits, and emergency procedures.

Solvent Selection

This product is a ready-to-use aqueous 2% staining solution. Solvent selection is typically not required unless you plan to dilute or rinse.

  • Polarity/miscibility (general):

    • Matrix: Water (item-specific co-solvents not provided).
    • Fully miscible with water and common aqueous buffers (PBS, TBE/TBE, Tris-based), though buffer components can influence spectral properties and background.
    • Limited compatibility with nonpolar solvents; methylene blue partitions poorly into hydrophobic media due to its cationic nature (literature).
  • When to dilute in buffer vs. water:

    • Use water for simple cellular or microbial wet-mount stains where ionic strength/pH control is not critical.
    • Use buffered saline (e.g., PBS) when staining fixed tissues or gels where pH stability and osmolarity reduce background and preserve morphology.
  • Rinsing/destaining:

    • Rinse with water or the working buffer to reduce nonspecific background.
    • For nucleic acid gel work, prolonged rinsing in buffer/water can lower background while preserving band contrast.
  • Comparison (general context):

    • Versus organic dye solutions (e.g., in ethanol): aqueous MB minimizes solvent hazards and is compatible with live-wet mounts (non-sterile research use), but dries slowly and readily stains glass/plastics.
    • Versus basic counterstains like crystal violet or safranin (often in alcohol): MB is gentler and easier to clean up but offers different specificity and hue.
Storage and Reconstitution
  • Storage conditions (item-specific): Room temperature (per product data). Protect from prolonged direct light to minimize photofading (best practice for phenothiazinium dyes).
  • Shipping: Normal (ambient) per product data.
  • Format: Ready-to-use 2% staining solution. No reconstitution required.

Handling and longevity (general best practices):

  • Keep container tightly closed to limit evaporation and contamination. Wipe threads and cap interior to avoid crystallized residue/staining.
  • If precipitate or microbial contamination is observed, discard the solution. If minor particulates form, you may pre-filter a portion through a 0.22–0.45 µm membrane for immediate use; do not return filtered aliquots to the stock.
  • For long experiments, transfer a working aliquot to an amber vial or wrap in foil to reduce light exposure.

Compatibility and dilution:

  • Dilute with water or appropriate buffer immediately before use. Record final dilution, buffer composition, and date of preparation.

Item-specific parameters not provided:

  • pH, stabilizers, preservative content, and exact counterion — Not specified for this item; refer to CoA/Spec Sheet.

Always consult the product label and SDS for any additional storage cautions or incompatibilities.

Structure and Identity

A ready-to-use 2% aqueous staining solution formulated with the cationic phenothiazinium dye commonly known as methylene blue (MB), supplied for life-science staining workflows.

  • SKU: M1528810
  • Product name: Methylene Blue Staining Solution (2%)
  • Formulation: 2% (w/v) solution; precise composition (counterion, stabilizers, pH) — Not specified for this item; refer to CoA/Spec Sheet.
  • Grade: BioReagent
  • Research use: For research use only

Structural features of the active dye (methylene blue) — literature description:

  • Core scaffold: Tricyclic phenothiazinium ring system (thiazine fused to two benzene rings)
  • Charge/state: Cationic chromophore; commonly isolated as a chloride salt; may occur with variable hydration (literature)
  • Functional motifs: Dimethylamino substituents (electron-donating), sulfur and tertiary amine within the phenothiazine core, conjugated system responsible for intense blue color
  • 2D structure (verbal): A planar, extended, polycyclic aromatic system containing a central thiazine ring (S and N in ring), para-dimethylamino phenyl substituents create a delocalized, resonance-stabilized cation.

Identifiers for methylene blue (active dye) — literature values (for reference only; not item-specific):

  • Common name: Methylene blue (also: methylthioninium chloride)
  • Molecular formula (anhydrous salt, literature): C16H18ClN3S
  • Molecular weight (anhydrous salt, literature): ~319.85 g/mol (hydration state can increase apparent MW)
  • SMILES (literature, representative cation): CN(C)c1ccc2nc3ccc(=N+C)sc3cc2c1 · Cl− (counterion not shown in cation SMILES)
  • InChIKey (literature, methylthioninium chloride): Not specified here to avoid conflating item-specific identity; consult primary databases.

Note: Because this listing is for a prepared 2% solution, batch-specific identifiers (exact salt form, pH, excipients) should be taken from the item’s CoA/Spec Sheet.

Synthetic Utility

While primarily a biological stain, the active dye methylene blue has recognized roles in chemical methodology (literature context).

  • Photoredox catalysis: Serves as an organic photosensitizer for visible-light-driven oxidations (e.g., aerobic oxidative coupling, sulfide to sulfoxide conversions) via generation of singlet oxygen or electron-transfer pathways. The cationic nature can influence substrate association in polar media.

  • Redox mediator: Useful as an electron shuttle in electrochemical setups and biochemical model systems; reversible MB/leucomethylene blue couple provides a convenient spectroscopic handle around 660–668 nm.

  • Analytical chemistry: Acts as a reporter dye in methylene blue active substances (MBAS) assays for anionic surfactants; ion-pair formation and extraction underpin the method.

  • Practical note for this 2% solution: For synthetic/analytical uses requiring defined molarity, determine concentration by UV–Vis using an appropriate extinction coefficient (literature) because mass% of the solution may not directly translate to molarity without density and exact salt/hydration details. Alternatively, prepare standard curves versus known MB standards.

  • Compatibility: Best in aqueous or mixed polar solvents; strong reducing agents will bleach the dye, terminating photoredox cycles unless reoxidized by air or an oxidant.

Target Specificity

Not applicable. This product is a general staining solution and is not an antibody, probe, or affinity reagent with defined target specificity.

  • No antigen/epitope, clone, isotype, or species reactivity information is relevant to this item.
  • For nucleic acid visualization, methylene blue interacts broadly with DNA/RNA via electrostatic/intercalative mechanisms (literature, non-specific). If sequence-specific recognition is required, use labeled probes or antibodies designed for your target.

Desidera che le inviamo un messaggio quando avremo sconti disponibili?

Ricordamelo più tardi

Grazie! Controlli la sua casella di posta per confermare.

Ops! Le notifiche sono disabilitate.