Technical Articles: Reagent Chemistry, Synthesis & Bioscience Guides

Aflatoxin B1 (AFB1) ELISA Kit Protocol & Usage Guide

Aflatoxin B1 (AFB1) ELISA Kit is a sensitive, competitive enzyme-linked immunosorbent assay designed for the quantitative determination of AFB1 in food, feed, agricultural commodities, and biological matrices.

Assay Principle
Competitive ELISA (indirect format); AFB1 in the sample competes with enzyme-conjugated AFB1 for antibody binding sites
Recommended Sample Types
Grain, corn, peanut, feed, spices, and other food/agricultural matrices
Detection Method
Colorimetric absorbance measurement at 450 nm
Storage Condition
Store at 2–8 °C; avoid freeze-thaw cycles

Principle and Kit Overview

The Aflatoxin B1 (AFB1) ELISA Kit (EJ1515354) employs a competitive enzyme-linked immunosorbent assay (ELISA) format. Microtiter plate wells are pre-coated with an AFB1–protein conjugate. During the assay, free AFB1 present in the sample competes with the plate-bound conjugate for a limited number of anti-AFB1 antibody binding sites. After washing away unbound components, an enzyme-labeled secondary antibody and substrate solution are added. The resulting colorimetric signal is inversely proportional to the AFB1 concentration in the sample: higher AFB1 levels yield lower absorbance values. A standard curve constructed from provided calibrators is used to calculate the AFB1 concentration in unknown samples.

This kit is intended for research use in food safety screening, agricultural quality control, and mycotoxin research. It offers a rapid alternative to chromatographic methods such as HPLC-MS for high-throughput screening.

Materials Required and Sample Preparation

Materials provided in the kit: Pre-coated microtiter plate, AFB1 standards, enzyme-conjugate reagent, anti-AFB1 antibody solution, wash buffer concentrate, substrate solution (TMB), stop solution, and assay diluent.

Materials required but not provided: Microplate reader capable of measuring absorbance at 450 nm, multichannel pipette and tips, distilled or deionized water, graduated cylinders, timer, and appropriate personal protective equipment (PPE) including gloves, lab coat, and eye protection.

Sample preparation — solid food/feed matrices:

  1. Finely grind the sample and weigh an appropriate amount (typically 5–10 g) into an extraction vessel.
  2. Add a suitable extraction solvent (commonly 70% methanol/water or acetonitrile/water) at a ratio recommended in the kit insert. Shake or vortex vigorously for 3–5 minutes.
  3. Centrifuge at approximately 3,000–5,000 × g for 5–10 minutes. Collect the supernatant.
  4. Dilute the extract with the assay diluent at the ratio specified in the kit insert before adding to the plate. This step reduces matrix effects and brings the extract within the assay range.

Important: Aflatoxin B1 is a potent mycotoxin and classified as an IARC Group 1 carcinogen. All sample handling must be performed in a well-ventilated fume hood. Contaminated materials must be decontaminated with 5% sodium hypochlorite solution before disposal. Consult the relevant Safety Data Sheet (SDS) before use.

Step-by-Step Assay Procedure

Allow all kit reagents to equilibrate to room temperature (18–25 °C) for at least 30 minutes before use. Prepare the wash buffer by diluting the concentrate with deionized water according to the kit insert instructions.

  1. Standard and sample addition: Pipette the AFB1 standards and prepared samples into the designated wells in duplicate. Include a blank (assay diluent only) and all standard concentrations in each run.
  2. Antibody addition: Add the anti-AFB1 antibody solution to each well immediately after samples and standards. Mix gently by tapping the plate frame.
  3. First incubation: Cover the plate with the provided adhesive film and incubate at room temperature for the time specified in the kit insert (typically 30–60 minutes) on a plate shaker set to low speed.
  4. Washing: Aspirate or flick out the contents of the wells. Wash the plate 3–5 times with diluted wash buffer (300 µL per well per wash). After the final wash, invert the plate and blot firmly on absorbent paper to remove residual liquid.
  5. Enzyme conjugate addition: Add the enzyme-conjugate reagent to each well. Incubate as specified in the kit insert.
  6. Second washing: Repeat the wash procedure as described in step 4.
  7. Substrate addition: Add the TMB substrate solution to each well. Incubate at room temperature in the dark for the time specified in the kit insert. A blue color will develop in wells with low AFB1 concentrations.
  8. Stop and read: Add the stop solution to each well in the same order and at the same pace as the substrate. The color will change from blue to yellow. Measure the absorbance at 450 nm within 10 minutes using a microplate reader.

Record all absorbance values immediately after reading. Do not freeze the plate after the assay has begun.

Data Analysis and Results Interpretation

Constructing the standard curve: Calculate the mean absorbance (OD450) for each standard and sample from duplicate readings. Divide each mean OD value by the mean OD of the zero standard (B/B0 × 100%) to obtain the percentage binding. Plot the percentage binding on the y-axis against the corresponding AFB1 standard concentration on the x-axis using a semi-logarithmic or four-parameter logistic (4PL) curve-fit model.

Calculating sample concentrations: Interpolate the AFB1 concentration for each sample from the standard curve using its percentage binding value. Multiply the interpolated concentration by the dilution factor applied during sample preparation to obtain the final concentration in the original sample.

Acceptance criteria: A valid assay requires that the standard curve exhibits the expected sigmoidal shape and that the absorbance values of the standards decrease monotonically with increasing AFB1 concentration. Duplicate coefficient of variation (CV%) should generally be below 15%.

Reporting units: Results are typically expressed in ng/mL (ppb) for liquid extracts and converted to ng/g (ppb) for solid matrices by accounting for the extraction volume, sample weight, and dilution factor.

Troubleshooting Guide

The following table summarizes common issues and their likely causes and remedies when using the Aflatoxin B1 (AFB1) ELISA Kit.

  • High background / high blank OD: Ensure complete aspiration of liquid during washing steps. Increase the number of wash cycles. Check that substrate solution has not been contaminated and is stored away from light.
  • Low or no color development: Verify that the enzyme conjugate and substrate were added and that reagents were equilibrated to room temperature before use. Check that the stop solution was not added before sufficient substrate incubation time.
  • Poor standard curve (flat or non-sigmoidal): Confirm that standards were prepared and diluted correctly. Ensure the kit has not expired and has been stored at 2–8 °C. Avoid using reagents that have been frozen unless specified.
  • High CV% between duplicates (>15%): Use calibrated pipettes. Ensure homogeneous mixing after each reagent addition. Minimize time differences between wells during reagent dispensing by using a multichannel pipette.
  • Sample OD outside the standard curve range: Re-extract and re-dilute the sample to bring the response within the linear range of the standard curve. Apply the appropriate dilution factor when back-calculating the concentration.
  • Non-specific inhibition / matrix effects: Increase the dilution of the sample extract in assay diluent. Consider using a sample clean-up procedure such as immunoaffinity column (IAC) purification prior to assay.

Frequently asked questions

What sample types are compatible with the Aflatoxin B1 (AFB1) ELISA Kit?

The Aflatoxin B1 (AFB1) ELISA Kit (EJ1515354) is designed for use with a wide range of food and feed matrices, including cereals, corn, peanuts, animal feed, spices, and dried fruits. Sample extracts prepared using aqueous methanol or acetonitrile extraction followed by appropriate dilution in assay diluent are generally compatible. Always consult the kit insert for matrix-specific preparation and dilution recommendations.

How should the Aflatoxin B1 (AFB1) ELISA Kit be stored, and what is its stability?

The Aflatoxin B1 (AFB1) ELISA Kit should be stored at 2–8 °C. Reagents should not be frozen unless specified in the kit insert, as freeze-thaw cycles can denature the antibody and enzyme conjugate components and compromise assay performance. Use all components before the expiry date printed on the outer packaging. Once the foil-sealed plate is opened, unused strips should be resealed with desiccant and stored at 2–8 °C.

Is the Aflatoxin B1 (AFB1) ELISA Kit suitable for regulatory or confirmatory testing?

The Aflatoxin B1 (AFB1) ELISA Kit is intended for research use only and is optimized for high-throughput screening applications. For regulatory compliance or official confirmatory purposes, results should be verified using validated reference methods such as HPLC with fluorescence detection (HPLC-FLD) or liquid chromatography–mass spectrometry (LC-MS/MS) in accordance with applicable national or international standards.

Can the assay be run with fewer than a full plate of samples?

Yes. The Aflatoxin B1 (AFB1) ELISA Kit is typically formatted with breakable strip wells, allowing the user to run only the number of wells required. Unused strips should be resealed with desiccant and stored at 2–8 °C for future use. Always include the full set of standards and a blank in each partial run to ensure a valid standard curve.

References

  1. International Agency for Research on Cancer (IARC). Aflatoxins. IARC Monographs on the Evaluation of Carcinogenic Risks to Humans. Volume 100F. Lyon, France: IARC; 2012.
  2. European Commission Regulation (EC) No 1881/2006 of 19 December 2006 setting maximum levels for certain contaminants in foodstuffs. Official Journal of the European Union.
  3. Anfossi L, Baggiani C, Giovannoli C, D'Arco G, Giraudi G. Lateral-flow immunoassays for mycotoxins and phycotoxins: a review. Analytical and Bioanalytical Chemistry. 2013;405(23):7553–7567. doi:10.1007/s00216-013-7205-x

Products are supplied for research and development use only. Not for use in humans, animals, diagnosis, or therapy.

Categories: Technical Articles: Reagent Chemistry, Synthesis & Bioscience Guides

Products are supplied for research and development use only. Not for use in humans, animals, diagnosis, or therapy.

Cite this article

Aladdin Scientific. "Aflatoxin B1 (AFB1) ELISA Kit Protocol & Usage Guide" Aladdin Knowledge Base, updated 24/11/2026. https://www.aladdinsci.com/us_pt/faqs/aflatoxin-b1-afb1-elisa-kit-protocol-en.html
Was this article helpful? Yes No 6 out of 13 found this helpful

Deseja que lhe enviemos uma mensagem quando tivermos descontos disponíveis?

Lembrar-me mais tarde

Obrigado! Por favor, verifique a sua caixa de entrada de e-mail para confirmar.

Ops! As notificações estão desativadas.