Technical Articles: Reagent Chemistry, Synthesis & Bioscience Guides

Mesoporous Carbon Handling & Characterization Protocol

(停产)Carbon, mesoporous is a high-surface-area graphitized carbon material featuring an ordered mesopore architecture that makes it valuable for adsorption, catalysis support, and electrochemical energy-storage research.

Reference Number
Sigma 699624
Product Status
Discontinued (停产)
Material Class
Graphitized mesoporous carbon
Pore Size Range
Mesopore regime: 2–50 nm (IUPAC definition)
Primary Applications
Adsorption, electrode fabrication, catalyst support

Materials, Safety & Storage

(停产)Carbon, mesoporous (C431910) is a finely divided carbonaceous powder. Before working with this material, review the relevant Safety Data Sheet (SDS). Key precautions include:

  • Personal protective equipment: Wear a NIOSH-approved dust respirator (minimum N95), chemical-splash goggles, and nitrile gloves when weighing or transferring the powder, as fine carbon particles are a potential inhalation hazard.
  • Engineering controls: Conduct all powder-handling steps inside a fume hood or a well-ventilated enclosure to prevent airborne dust accumulation.
  • Storage: Store in a tightly sealed container at room temperature (15–25 °C) in a dry environment away from strong oxidizers. Moisture uptake can alter surface chemistry and pore characteristics.
  • Waste disposal: Dispose of carbon powder and contaminated materials according to local regulations for solid chemical waste.

Required materials: analytical balance (±0.1 mg), spatula (PTFE or stainless steel), amber glass or HDPE storage vials, desiccator, and appropriate solvent (e.g., ethanol or water) for dispersion experiments.

Sample Preparation & Dispersion

Proper dispersion of (停产)Carbon, mesoporous is critical for reproducible results in both analytical characterization and application testing. Follow the steps below:

  1. Drying: Prior to any gravimetric measurement or BET analysis, dry the carbon powder at 100–120 °C under vacuum for at least 2 hours to remove adsorbed moisture. Allow to cool in a desiccator before weighing.
  2. Weighing: Tare a clean vial on the analytical balance. Using a micro-spatula, transfer the required mass of powder (typically 10–50 mg for characterization; 1–5 mg mL⁻¹ for dispersion).
  3. Dispersion in aqueous media: Add the weighed powder to the chosen solvent. Sonicate using a probe or bath sonicator for 10–30 minutes in an ice bath to prevent local heating. For electrode inks, a common formulation uses 5 wt% Nafion solution as a binder (ratio to be optimized per application).
  4. Dispersion in organic solvents: Isopropanol (IPA) or N-methyl-2-pyrrolidone (NMP) are commonly used. Probe sonication at low amplitude (20–30% of maximum) for 15–20 minutes is recommended.
  5. Stability check: Allow the dispersion to stand for 30 minutes and visually inspect for rapid sedimentation, which indicates insufficient sonication or incompatible solvent choice.

Note: The mesoporous architecture of this carbon provides a large internal surface area, meaning solvent uptake into pores may cause the dispersion to appear less concentrated than expected; account for this in concentration calculations.

Pore Structure Characterization (BET & BJH)

The defining feature of (停产)Carbon, mesoporous is its high specific surface area and controlled pore size distribution. The standard characterization workflow uses nitrogen physisorption:

  1. Instrument preparation: Use a volumetric gas-adsorption analyzer (e.g., Micromeritics ASAP series or equivalent). Calibrate with certified reference materials before testing unknown samples.
  2. Sample degassing: Load 50–100 mg of dried carbon into the sample tube. Degas at 150–200 °C under vacuum (target <5 µmHg) for a minimum of 4 hours to remove all physisorbed species.
  3. Adsorption isotherm measurement: Run a full N₂ adsorption–desorption isotherm at 77 K (liquid nitrogen). Collect at least 30 data points across relative pressures (P/P₀) from 0.01 to 0.99.
  4. BET surface area: Apply the Brunauer–Emmett–Teller (BET) model to the linear region of the isotherm (typically P/P₀ = 0.05–0.30) to determine specific surface area (m² g⁻¹).
  5. Pore size distribution: Apply the Barrett–Joyner–Halenda (BJH) method to the desorption branch of the isotherm to calculate pore size distribution and total pore volume. For mesoporous carbons, expect a dominant peak in the 2–50 nm range.
  6. Data reporting: Report BET surface area (m² g⁻¹), BJH average pore diameter (nm), total pore volume (cm³ g⁻¹), and isotherm type (expected Type IV for mesoporous materials with hysteresis loop).

Complementary techniques: Transmission electron microscopy (TEM) can confirm pore morphology; Raman spectroscopy (D and G bands) can assess the degree of graphitization of the carbon framework.

Typical Application Workflows

(停产)Carbon, mesoporous has been used in several research domains. Representative workflows are described below.

Electrochemical Electrode Fabrication

  1. Prepare an ink by dispersing carbon powder in IPA with Nafion binder (mass ratio to be optimized, typically 90:10 carbon:binder by dry weight).
  2. Sonicate the ink for 30 minutes in an ice bath.
  3. Deposit the ink onto a glassy carbon or carbon paper substrate by drop-casting or spray-coating.
  4. Dry at 60–80 °C under mild vacuum or in air to evaporate solvent.
  5. Characterize electrode performance by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) in the electrolyte of interest.

Adsorption Studies

  1. Prepare stock solutions of the target analyte (e.g., organic dye or heavy metal ion) at known concentrations.
  2. Add a defined mass of carbon (e.g., 5 mg) to each analyte solution (e.g., 10 mL) in sealed vials.
  3. Agitate on a rotary shaker at room temperature for a defined contact time (e.g., 2–24 hours).
  4. Centrifuge or filter the suspension, then analyze the supernatant by UV-Vis spectrophotometry or ICP-MS to determine residual analyte concentration.
  5. Calculate adsorption capacity (mg g⁻¹) using mass-balance equations.

Catalyst Support Preparation

  1. Disperse the carbon in the appropriate solvent and add the metal precursor salt (e.g., chloroplatinic acid for Pt catalysts) in the desired loading ratio.
  2. Stir at room temperature or under mild heating, then reduce using a chemical reductant (e.g., NaBH₄) or via thermal reduction under H₂/Ar atmosphere.
  3. Filter, wash, and dry the supported catalyst. Characterize by XRD, TEM, and ICP-OES to confirm metal loading and dispersion.

Troubleshooting & Discontinued-Product Guidance

Because (停产)Carbon, mesoporous (C431910) has been discontinued, users should consider the following guidance:

IssueLikely CauseRecommended Action
Poor dispersion / rapid settlingInsufficient sonication energy; hydrophobic surfaceIncrease sonication time; switch to IPA or add surfactant; verify solvent compatibility
Low BET surface area vs. specificationInadequate degassing; moisture contaminationExtend degassing time and increase temperature; store material in desiccator
Irreproducible electrode performanceNon-uniform ink deposition; variable drying conditionsUse automated pipette for consistent volume; control drying temperature precisely
Product unavailable for reorderItem discontinued (停产)Contact Aladdin Scientific technical support to identify a suitable alternative mesoporous carbon grade; specify required surface area, pore volume, and application

Discontinued-product notice: Stock remaining in your laboratory should be used according to the original SDS and within any stated shelf-life. For publication purposes, cite the Sigma reference number 699624 and note that the product is no longer commercially available. Contact Aladdin Scientific for alternative product recommendations.

Frequently asked questions

What is mesoporous carbon and why is it useful in research?

Mesoporous carbon is a carbon material with a controlled pore structure in the 2–50 nm range (IUPAC definition), resulting in a high specific surface area and large pore volume. These properties make it valuable as an electrode material in supercapacitors and batteries, as a catalyst support, and as an adsorbent for pollutants or biomolecules.

How should mesoporous carbon (C431910) be stored to maintain its properties?
(停产)Carbon, mesoporous (C431910) should be stored in a tightly sealed container at room temperature (15–25 °C) in a dry environment, ideally inside a desiccator. Prolonged exposure to moisture can alter surface chemistry and block mesopores, reducing effective surface area and adsorption capacity.
What analytical methods are used to characterize mesoporous carbon?

The primary characterization method is nitrogen physisorption at 77 K to determine BET specific surface area and BJH pore size distribution. Complementary methods include transmission electron microscopy (TEM) for direct pore imaging, Raman spectroscopy to assess graphitization (D and G bands), and X-ray diffraction (XRD) to evaluate crystallinity.

Since C431910 is discontinued, what should I do if I need a similar product?

Contact Aladdin Scientific technical support and specify your application requirements, including the minimum BET surface area, pore size range, pore volume, and any purity or particle-size constraints. The team can recommend a currently available mesoporous or high-surface-area carbon product that meets your experimental needs.

Is mesoporous carbon safe to handle in a standard laboratory setting?

Mesoporous carbon is generally of low acute toxicity, but fine carbon particles present an inhalation risk. Always handle the powder in a well-ventilated fume hood, wear an N95 or higher dust respirator, chemical-splash goggles, and nitrile gloves. Consult the SDS for complete hazard information before use.

References

  1. Brunauer, S.; Emmett, P. H.; Teller, E. Adsorption of Gases in Multimolecular Layers. Journal of the American Chemical Society, 1938, 60(2), 309–319. doi:10.1021/ja01269a023
  2. Barrett, E. P.; Joyner, L. G.; Halenda, P. P. The Determination of Pore Volume and Area Distributions in Porous Substances. Journal of the American Chemical Society, 1951, 73(1), 373–380. doi:10.1021/ja01145a126
  3. IUPAC. Recommendations for the characterization of porous solids. Pure and Applied Chemistry, 1994, 66(8), 1739–1758. doi:10.1351/pac199466081739
  4. Ryoo, R.; Joo, S. H.; Jun, S. Synthesis of Highly Ordered Carbon Molecular Sieves via Template-Mediated Structural Transformation. Journal of Physical Chemistry B, 1999, 103(37), 7743–7746. doi:10.1021/jp993846g

Products are supplied for research and development use only. Not for use in humans, animals, diagnosis, or therapy.

Categories: Technical Articles: Reagent Chemistry, Synthesis & Bioscience Guides

Products are supplied for research and development use only. Not for use in humans, animals, diagnosis, or therapy.

Cite this article

Aladdin Scientific. "Mesoporous Carbon Handling & Characterization Protocol" Aladdin Knowledge Base, updated 23/11/2026. https://www.aladdinsci.com/us_pt/faqs/mesoporous-carbon-handling-characterization-protocol-en.html
Was this article helpful? Yes No 2 out of 3 found this helpful

Deseja que lhe enviemos uma mensagem quando tivermos descontos disponíveis?

Lembrar-me mais tarde

Obrigado! Por favor, verifique a sua caixa de entrada de e-mail para confirmar.

Ops! As notificações estão desativadas.