L-Hexanoylcarnitine-d 3 (chloride) is the deuterium labeled L-Hexanoylcarnitine chloride.
In Vitro
Stable heavy isotopes of hydrogen, carbon, and other elements have been incorporated into drug molecules, largely as tracers for quantitation during the drug development process. Deuteration has gained attention because of its potential to affect the pharmacokinetic and metabolic profiles of drugs. MCE has not independently confirmed the accuracy of these methods. They are for reference only.
Form:Solid
Specifications
Specifications & Purity
≥99%
Biochemical and Physiological Mechanisms
L-Hexanoylcarnitine-d 3 (chloride) is the deuterium labeled L-Hexanoylcarnitine chloride.
Storage
Store at 2-8°C,Desiccated
Shipped In
Wet ice
This product requires cold chain shipping. Ground and other economy services are not available.
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Reviews
Customer Reviews
Application Protocols
Not applicable in the sense of antibody/cell imaging protocols. For small‑molecule analytical standards, the following general LC–MS workflow notes are provided (literature/general best practices):
Internal standard spiking: Add a fixed concentration of L‑hexanoylcarnitine‑d3 chloride to all calibrators, QCs, and unknowns prior to sample prep to correct for recovery and ion suppression.
Sample preparation: Protein precipitation with 3–4 volumes of cold methanol (or acetonitrile), vortex, incubate, and centrifuge. Transfer supernatant to LC–MS vials and dilute with initial mobile phase.
Chromatography: Reversed‑phase or HILIC can be used. Start with aqueous (0.1% formic acid) and organic (MeOH or ACN + 0.1% FA) mobile phases; gradient adjusted to resolve C2–C18 acylcarnitines.
Detection: ESI positive mode; monitor MRM of the d3 parent/product ion pair matched to the unlabeled analyte transition with shifted m/z.
Calibration: Construct matrix‑matched calibration curves; use weighted regression (e.g., 1/x or 1/x2) typical for wide dynamic ranges.
These are illustrative, method‑agnostic notes; tailor to your instrumentation and regulatory context.
Biological Roles
This product is a labeled analogue used to study endogenous biology; the following describes the unlabeled hexanoylcarnitine in biological systems (literature/general). No biological activity is claimed for this product beyond research use.
Role in metabolism: Hexanoylcarnitine is an acylcarnitine formed by carnitine O‑acyltransferases to shuttle medium‑chain fatty acids (C6) across mitochondrial membranes for β‑oxidation. It reflects the acyl‑CoA pool and carnitine availability.
Transport: Carnitine/acylcarnitine translocase (CACT) exchanges acylcarnitines and free carnitine across the inner mitochondrial membrane (literature). The quaternary ammonium facilitates carrier recognition.
Analytical biomarker context: Medium‑chain acylcarnitines are monitored in metabolomics to evaluate fatty acid oxidation flux, peroxisomal activity, and nutritional state (fasting/feeding). The d3 standard enables accurate quantification of the endogenous compound via isotope dilution.
Ionization/fragmentation in MS (general): Positive ESI produces abundant [M]+ due to the permanent cation; characteristic fragments include neutral losses and acyl‑specific ions, supporting selective MRM transitions.
Caveat: The deuterated standard is not intended to perturb biological systems; it is used as a spike‑in to correct for matrix effects and losses during sample preparation and analysis.
Buffer Applications
Not typically used as a buffer component. L‑Hexanoylcarnitine‑d3 chloride is an analytical standard for LC–MS workflows rather than a pH‑controlling reagent.
Practical note (general):
When preparing calibration or QC solutions, dissolve in water, methanol, or aqueous organic mobile phase adjusted with a volatile acid (e.g., 0.1% formic acid) to achieve consistent ionization in MS. Buffer capacity is provided by the mobile phase additives, not by the acylcarnitine standard itself.
Green Alternatives
As an analyte/reference standard, substitution is generally not appropriate; the labeled analogue must match the target analyte for accurate isotope‑dilution mass spectrometry. However, greener choices can be made around solvents and workflows.
Greener solvent choices (literature/general):
Prefer water/ethanol or water/methanol over acetonitrile where chromatographic performance allows. Methanol and ethanol have more favorable environmental profiles than acetonitrile.
Reduce organic consumption via UHPLC with shorter columns and optimized gradients.
Comparison of common mobile phases (general):
Water/methanol (with 0.1% formic acid): greener, good ESI response; may slightly alter selectivity versus ACN.
Miniaturize assays (microflow LC‑MS) to cut solvent use and waste.
Use reusable glass vials with low‑adsorption inserts to minimize plastics.
Implement on‑line SPE to reduce sample prep solvent volumes.
Trade‑offs:
Switching from acetonitrile to methanol can change retention and resolution among acylcarnitines; method re‑optimization (gradient, temperature) may be required.
Note: There is no true “green alternative” to the isotopically matched standard itself without compromising analytical specificity.
Pharmaceutical Uses
No therapeutic or clinical uses are claimed. This product is for research use only.
Employed as an internal standard in bioanalytical method development and validation supporting nonclinical or clinical pharmacokinetic/pharmacodynamic studies of lipid metabolism where endogenous acylcarnitines are quantified. The standard is spiked into matrix samples to ensure accurate quantitation.
Compatibility: The chloride salt form dissolves readily in common LC–MS diluents (water, methanol, acetonitrile/water with volatile acids), facilitating preparation of calibrators and quality controls.
Documentation: For regulated bioanalysis, use lots with complete CoA, stability data, and traceability; however, unless explicitly stated, this product is not GMP‑manufactured.
Excipient status: Not applicable—this compound is not used as a formulation excipient.
Regulatory references: None provided for this item; consult internal SOPs and applicable guidance (e.g., FDA/EMA bioanalytical method validation) when deploying isotope‑labeled standards in regulated studies.
Physical Properties
Item-specific physicochemical constants are not provided in the Product Data. Where useful, literature/general expectations for acylcarnitine chloride salts are summarized and clearly labeled.
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
Melting point: Not specified for this item; refer to CoA/Spec Sheet. (Literature: many acylcarnitine salts are low‑melting solids or glassy; values vary with chain length and counterion.)
Boiling point: Not applicable (decomposes before boiling; literature/general for ionic organic salts).
Density: Not specified for this item; refer to CoA/Spec Sheet.
Refractive index: Not applicable (solid) unless provided; Not specified for this item.
Solubility (literature/general): high in water and polar protic solvents (e.g., water, methanol), moderate in acetonitrile/water mixtures; poor in nonpolar solvents (hexanes, toluene). Exact solubility for this item: Not specified.
LogP/logD (literature/general): acylcarnitines show increasing apparent hydrophobicity with acyl chain length, yet remain overall polar due to the zwitterionic/quaternary ammonium motif; logD is pH‑dependent for nonpermanent charges; here the ammonium is permanent.
pKa (literature/general): quaternary ammonium has no acid–base equilibrium (permanent cation). Carboxylate is deprotonated in betaine form; no classical pKa applicable.
Hygroscopicity (literature/general): quaternary ammonium carnitine salts can be hygroscopic; minimize atmospheric moisture exposure.
Quality & Grades
Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
Context and expectations (general/literature for analytical isotope standards):
Isotopic enrichment: analytical d‑labeled acylcarnitines are typically supplied at ≥98 atom% D at the labeled positions to ensure minimal isotopic interference in LC–MS/MS quantitation. Exact enrichment for this item is not specified; refer to CoA for definitive value and labeling pattern.
Residual solvents/inorganic salts: high‑quality standards minimize residuals for accurate mass balance; specific limits for this item are not specified.
Counterion identity: this product is the chloride salt, providing excellent water/methanol solubility and stable ionization in ESI‑MS workflows; chloride content specifics are not provided here.
Documentation: for targeted bioanalytical use, request CoA with lot‑specific assay (purity by HPLC or qNMR), water content (Karl Fischer), and isotopic distribution.
What the grade implies (general):
Analytical/reference standard grade materials are optimized for identity/purity traceability and stability; they are not manufactured under GMP unless explicitly stated. Low UV background and LC compatibility are typical considerations for MS standards.
Compliance notes:
Research use only (non‑GMP, non‑clinical). For regulated work, maintain chain‑of‑custody and retain CoA and stability data for the lot in use.
Reaction & Applications
Primary utility is as an isotope‑labeled internal standard and reference material rather than as a synthetic reagent. Nevertheless, chemistry around acylcarnitines informs handling and method development.
LC–MS/MS internal standard for quantitation of endogenous L‑hexanoylcarnitine in biological matrices (plasma, serum, DBS). The d3 label provides mass separation to correct for matrix effects and ion suppression.
Method validation: used for calibration curves, recovery experiments, and stability studies (bench‑top, freeze–thaw, autosampler) in targeted metabolomics and lipidomics.
Chemical behavior and implications:
Ester moiety: susceptible to base‑catalyzed hydrolysis; maintain neutral/slightly acidic conditions in aqueous media. Acidic modifiers (0.1% formic acid) aid ESI positive‑mode response without rapid hydrolysis (literature practice).
Quaternary ammonium: enhances ESI+ ionization; common fragmentations include neutral losses (e.g., trimethylamine) and acyl‑specific product ions enabling MRM transitions (literature).
Practical tips:
Prepare fresh working dilutions daily for quantitative work; store concentrated stocks refrigerated as recommended (see Storage tab).
Use polypropylene or silanized glass to minimize adsorption; include BSA or organic modifiers in low‑ng/mL work if nonspecific binding is observed (method‑dependent).
Employ stable isotope‑labeled IS at a constant concentration across calibrators and samples to ensure accurate quantitation.
Reaction Conditions
As a reference standard, this compound is not commonly used as a reagent in transformations. The following conditions relate to stability and analytical workflows (literature/general):
Solution preparation: 0.1–1.0 mg/mL stock solutions in methanol, water, or 50:50 MeOH:H2O are typical for LC–MS standards; working solutions diluted to ng/mL–µg/mL as required. Exact concentrations are user/method dependent.
pH sensitivity: Avoid pH > 9 to minimize ester hydrolysis; neutral to mildly acidic (0.1% formic acid) conditions are common in LC–MS.
Temperature: Keep solutions refrigerated (4–8°C) when not in use; minimize autosampler residence at ambient temperature during long sequences to limit degradation.
Light: No specific photolability is reported for acylcarnitines; store protected from light as a general precaution.
Matrix extraction: Protein precipitation with MeOH or ACN, followed by dilution into initial mobile phase, is widely used. Solid‑phase extraction (mixed‑mode cation exchange) can enhance cleanliness for complex matrices.
MS settings (example guidance; literature): quantify in ESI positive mode with MRM transitions targeting the labeled parent and characteristic fragments; collision energies are compound‑ and instrument‑specific.
All parameters above are general guidance; optimize for your instrument and matrix. Item‑specific stability data should be taken from the CoA or internal validation.
Safety & Handling
GHS classification: Not specified for this item; refer to SDS.
Signal word / H‑statements / pictograms: Not specified for this item; refer to SDS.
General laboratory safety (literature/general for organic salts and isotope‑labeled standards):
PPE: wear lab coat, safety glasses, and suitable chemical‑resistant gloves. Handle powders in a fume hood or ventilated enclosure to avoid inhalation of dust/aerosols.
Avoid contact with strong oxidizers and strong acids/bases that can catalyze ester hydrolysis or decomposition.
Thermal stability: ester functionality may hydrolyze under strong acidic/basic or high‑temperature conditions; avoid unnecessary heating.
Deuterated material handling: treat as you would the unlabeled analogue; isotopic labeling does not inherently change hazard classification but is valuable for traceability—prevent cross‑contamination with unlabeled standards.
First aid (overview; defer to SDS):
Inhalation: move to fresh air; seek medical attention if symptoms develop.
Skin/eye contact: rinse with water for several minutes; remove contaminated clothing; seek medical advice if irritation persists.
Ingestion: rinse mouth; seek medical attention.
Spill/leak response: avoid dust generation; collect with inert absorbent, transfer to appropriate waste.
Waste: dispose in accordance with institutional and local regulations for organic laboratory chemicals and isotope‑labeled standards.
Storage incompatibilities: store away from moisture and reactive chemicals; avoid prolonged exposure to basic solutions which can saponify the ester.
Solvent Selection
Given the quaternary ammonium and carboxylate (betaine) character plus an esterified C6 acyl chain, L‑hexanoylcarnitine‑d3 chloride is overall polar yet amphiphilic.
Solubility/miscibility (literature/general; item-specific values not provided):
Highly soluble: water, methanol, ethanol; also miscible in aqueous acetonitrile and aqueous isopropanol commonly used in LC–MS mobile phases.
Moderately soluble: neat acetonitrile, dimethyl sulfoxide (DMSO); solubility improved by small amounts of water or acid modifier (e.g., 0.1% formic acid) for LC–MS.
Poorly soluble: nonpolar solvents (hexanes, cyclohexane, toluene, CPME) due to the permanent cationic headgroup.
Polarity/dielectric considerations (general):
Permanent cation (trimethylammonium) promotes strong ion–dipole interactions in high‑dielectric media (water, MeOH, MeCN/H2O). The C6 acyl chain modestly increases hydrophobic interactions (useful for reversed‑phase retention).
Practical selection tips:
For stock solutions (analytical): prepare in water, methanol, or 50:50 MeOH:H2O with 0.1% formic acid to enhance stability and ionization (literature practice). Filter (0.2 µm) if particulates are observed.
For sample prep: avoid strong bases which can hydrolyze the ester; neutral to slightly acidic aqueous/organic systems are preferred.
Comparison (general):
Shorter acylcarnitines (e.g., acetyl‑carnitine) are more hydrophilic; longer chains (e.g., palmitoyl‑carnitine) need higher organic content for dissolution and chromatographic elution. Hexanoyl sits mid‑range, eluting at moderate organic in RP‑LC.
Storage & Reconstitution
Storage conditions (item‑specific from Product Data): Store at 2–8°C, desiccated.
Shipping (item‑specific): Shipped on wet ice.
General reconstitution guidance (literature/general for acylcarnitine standards):
Solvents: Dissolve in high‑purity water, methanol, or 50:50 MeOH:H2O. For LC–MS, inclusion of 0.1% formic acid can enhance ionization and solution stability. Sonicate briefly if needed; avoid strong bases.
Concentrates vs. working stocks: Prepare a concentrated stock (e.g., 0.5–1 mg/mL) and aliquot to minimize freeze–thaw. Working solutions can be prepared freshly on the day of use at the required concentration.
Containers: Use low‑adsorption polypropylene or silanized glass vials. Rinse containers with solvent prior to use to reduce adsorption losses.
Stability: Item‑specific stability data are not provided; refer to CoA/Spec Sheet. As general practice, store sealed, desiccated, and protected from light; limit time at room temperature.
Freeze–thaw: Although shipped cold and stored refrigerated, if frozen aliquots are prepared, avoid repeated freeze–thaw cycles; thaw on ice and mix gently.
Note: Always consult the lot‑specific CoA/SDS for definitive guidance on concentration limits, solution stability, and any special precautions.
Research Use Note (item‑specific): For research use only.
Structure & Identity
L‑Hexanoylcarnitine‑d3 chloride is a deuterium‑labeled acylcarnitine: the L‑carnitine scaffold is O‑acylated with a hexanoyl (caproyl) group in which three hydrogens are replaced by deuterium (d3). The quaternary ammonium of carnitine is balanced by chloride.
SKU: L647203
Product name: L‑Hexanoylcarnitine‑d3 chloride
CAS: 2483831‑95‑2
Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
InChIKey: Not specified for this item; refer to CoA/Spec Sheet.
Structural features (general/literature description):
Core scaffold: L‑carnitine (trimethylated quaternary ammonium attached to a chiral β‑hydroxy carboxylate, typically existing as a zwitterion with an external chloride counterion in the chloride salt form).
Functional groups: quaternary ammonium (permanent cation), secondary alcohol (on C‑3 of carnitine), ester linkage (O‑acyl to hexanoyl‑d3), carboxylate (as part of the inner salt), chloride counterion.
Isotopic label: d3 commonly located on the terminal methyl of the hexanoyl chain in commercial standards (literature/general); exact labeling position for this item is not specified—refer to CoA.
Stereochemistry: L‑configuration at the carnitine center (literature), no additional stereocenters in the acyl chain.
2D description in words (literature/general): a trimethylammonium headgroup attached via a two‑carbon chain to a chiral carbon bearing a hydroxyl and an O‑acyl hexanoyl‑d3 ester; the carboxylate and quaternary ammonium form a betaine, paired with chloride.
Synthetic Utility
While primarily an analytical standard, understanding the functional groups informs potential chemical manipulations and stability.
Functional group reactivity (literature/general):
Ester (O‑acyl): susceptible to hydrolysis (base > acid) and transesterification under alcoholysis; avoids strong nucleophiles/bases during handling.
Quaternary ammonium: chemically robust; can engage in ion‑pair interactions and phase behavior but does not undergo typical amine acid–base chemistry.
Carboxylate (as betaine): limited reactivity in the salt; can be converted to other salts under ion‑exchange conditions.
Potential laboratory transformations (general):
Controlled hydrolysis to free L‑carnitine (analytical degradation studies) for stability‑indicating methods.
Derivatization for enhanced chromatographic behavior (e.g., formation of butyl esters of acylcarnitines for GC–MS workflows; note: this would alter the compound and is typically done on analyte in sample, not on the internal standard unless matched).
Retrosynthetic perspective (general):
Typically prepared by acylation of L‑carnitine (or its protecting group derivatives) with labeled hexanoyl‑d3 chloride/anhydride or via coupling to hexanoyl‑d3‑NHS ester under mild conditions, preserving stereochemistry at the L‑center.
Note: Any synthetic modification will defeat its role as a matched internal standard unless the analyte is derivatized in parallel.
Target Specificity
Not applicable. This product is a small‑molecule isotope‑labeled standard, not a biological affinity reagent. There is no antigen/epitope, clone, isotype, or species reactivity associated with this item.
Frequently Asked Questions
What is the purity of this product?
This product is supplied at ≥99% purity (chemical assay). Lot-specific values are stated on the Certificate of Analysis.
How should this product be stored?
Store at 2–8 °C, desiccated. Keep the container tightly closed with desiccant — the material is moisture-sensitive.
How is this product shipped?
This product ships chilled on wet ice. Unpack on arrival and transfer it to the storage condition stated above.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 2483831-95-2, the molecular formula is C13H23D3ClNO4, and the molecular weight is 298.82 g/mol.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
We use cookies to ensure the website functions properly and, where permitted, to improve your experience. You can manage your preferences at any time in Settings. Learn more in our Cookie Policy.
Shall we send you a message when we have discounts available?
Remind me later
Thank you! Please check your email inbox to confirm.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.