Nile Red Fluorescent Staining Solution - BioReagent

Cat. No.: N1528891
AVAILABLE TO ORDER
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
Storage
Store at -20°C
Shipped In
Ice chest + Ice pads
★
Size
Germany (EU)
USA*
Price
Qty
500ml
N1528891-500ml
Made to order · 8–12 wks
€156.11
Enter a quantity for the sizes you want to add.

Overview

Nile Red (9-diethylamino-5H-benzo[alpha]-phenoxazine-5-one; molecular formula: C₂₀H₁₈N₂O₂; molecular weight: 318.37) is a lipophilic fluorescent dye that can precisely distinguish intracellular lipids from other storage materials, and is commonly used for detecting lipid content in animal and microbial cells. The Nile Red fluorescence staining method offers advantages including rapidity, simplicity, high sensitivity, low sample requirement, and compatibility with continuous live-cell monitoring. Upon binding to lipids (including wax esters, triacylglycerols, and various fatty acids), it exhibits strong orange-red fluorescence when excited at 543 nm (emission wavelength: 598 nm), and also displays red fluorescence under ultraviolet light. This product is a ready-to-use fluorescence staining solution that has been rigorously sterilized. It enables rapid, sensitive, and reliable quantitative detection of intracellular lipid components in living cells through fluorescence signal generation upon lipid binding. It is suitable for lipid detection in various cell types, including bacterial cells, and can also be used for protein electrophoresis staining. For research use only. Not for other applications.

Specifications

Specifications & Purity
BioReagent
Storage
Store at -20°C
Shipped In
Ice chest + Ice pads
This product requires cold chain shipping. Ground and other economy services are not available.
Grade
BioReagent
Product Line
Biological Products

Advanced Data

Certificates (CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Solution Calculators
Reviews

Customer Reviews

Application Protocols

Manufacturer-validated applications, tested sample types, and recommended dilutions for SKU N1528891 are not specified in the provided product data. Please refer to the product label and CoA/Spec Sheet for any lot-specific instructions.

General guidance note (not a protocol and not item-specific):

  • Because Nile Red’s performance depends strongly on sample type and instrument configuration, users should consult primary literature and institutional SOPs for method development, then empirically optimize working concentration, incubation time, and wash conditions. Protect reagents and samples from light throughout.
Biological Roles

Scope: As a synthetic fluorescent probe, Nile Red does not have an intrinsic biological role. The following describes how it is used to interrogate biological systems (general/literature).

  • Reporter of neutral lipids: Nile Red partitions into hydrophobic stores (triacylglycerols, cholesteryl esters) and becomes strongly fluorescent, allowing visualization and semi-quantitative assessment of lipid accumulation in cells and organisms.
  • Membrane/environment polarity indicator: Emission maxima and intensity shift with the local dielectric environment; thus, the dye provides a qualitative readout of membrane order and microdomain composition.
  • Cellular compatibility: At low micromolar or sub-micromolar working concentrations and brief incubations, cells are typically amenable to staining; however, cytotoxicity can increase with concentration and solvent content (literature). Always perform cell line–specific optimization and controls.
  • Photophysics in biological media: Fluorescence is quenched in bulk aqueous phase, which improves contrast by limiting background; binding to serum proteins can produce weak background signals—hence serum-free staining is often recommended.
  • Multiplexing: Due to solvatochromism, emission color can vary between lipid droplets and membranes; this can be exploited to distinguish lipid species qualitatively, but requires careful spectral separation from other fluorophores.

Note: No clinical/diagnostic claims are made. Performance depends on sample type, fixation/permeabilization, and instrument configuration. Consult primary literature and validate in your specific model system.

Buffer Applications

Relevance: This product is a lipid-selective fluorescent staining solution. It does not function as a buffer. However, the choice of buffer during staining and imaging strongly influences background and specificity (general/literature guidance).

  • Compatible media for staining: Balanced salt solutions (e.g., PBS, HBSS) without serum or detergents typically minimize nonspecific background. After staining and washing, samples may be returned to complete media for imaging if required by the assay.
  • Detergents and serum: Detergents can solubilize lipids and disrupt partitioning; serum proteins can bind the dye and elevate background. Omit these components during the staining step when possible.
  • pH: Physiological pH (~7.2–7.4) is generally suitable; extreme pH can alter membrane integrity and dye photophysics (literature).
  • Fixation: For fixed-cell imaging, ensure fixatives are fully quenched and permeabilization conditions do not extract neutral lipids (avoid strong solvent extractions); validate retention of lipid droplets post-fixation.
  • Mounting media: Use antifade mounting media that do not contain surfactants that would mobilize lipids; verify spectral compatibility to avoid fluorescence attenuation or spectral shifts.

Item-specific buffer recommendations, working dilutions, and protocols are not provided in the product data for this SKU; refer to the CoA/Spec Sheet and SDS, and optimize conditions empirically for your system.

Green Alternatives

Assessment scope: This product is a fluorescent staining solution for research use. Environmental considerations mainly involve solvent choice, dye mass, and waste minimization. No item-specific solvent identity is provided.

Greener practice options (general guidance):

  • Minimize organic solvent carryover: Keep final DMSO/EtOH content in samples as low as feasible while maintaining staining quality.
  • Use smaller volumes and higher-sensitivity imaging to reduce dye usage and waste.
  • Consider solvent alternatives with improved safety profiles where compatible (e.g., aqueous-compatible delivery with cyclodextrins or Pluronic carriers at very low concentrations), but verify that such additives do not disrupt lipid partitioning or introduce background.
  • Waste management: Collect dye-containing solutions as hazardous waste; avoid drain disposal. Use amber vials to extend shelf life and reduce frequency of repurchase/shipping.

Comparative view (literature, qualitative):

  • Nile Red vs BODIPY neutral lipid probes: BODIPYs may allow lower working concentrations and more photostable imaging (less waste per experiment) but can require organic cosolvent stocks as well.
  • Nile Red vs solvatochromic “push–pull” alternatives (e.g., Laurdan): Laurdan enables membrane order mapping in aqueous media but typically requires UV/blue excitation and may not target neutral lipid droplets as selectively.

Trade-offs:

  • Switching probes can affect instrumentation (filter sets/lasers) and biological compatibility. Any change should be validated experimentally with attention to toxicity and background fluorescence.
Pharmaceutical Uses

This product is intended for research use only.

Contextual, non-clinical information (general/industry practice):

  • Analytical staining: Nile Red is used in research and development laboratories to visualize and estimate neutral lipid content in cells, microorganisms, and formulation matrices (e.g., lipid nanoparticles, emulsions) by fluorescence microscopy or spectroscopy.
  • Process/characterization support: In preclinical formulation labs, it may serve as a qualitative probe to assess lipid phase behavior, droplet presence, or polymer–lipid interactions. Such use is exploratory and not part of any pharmacopeial monograph.
  • Not an excipient or API: Nile Red is not recognized as a pharmaceutical excipient or active ingredient for human use. No clinical, diagnostic, or therapeutic applications are claimed or supported here.

Item-specific regulatory or compendial status: Not specified for this item; refer to CoA/Spec Sheet if needed for internal documentation.

Physical Properties

Item-specific properties (this solution):

  • Concentration, solvent, pH, and stabilizers: Not specified for this item; refer to CoA/Spec Sheet.
  • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Density, refractive index, viscosity: Not specified for this item; refer to CoA/Spec Sheet.

General/literature properties of Nile Red (neat dye) for context only (not item specifications):

  • Solubility: sparingly soluble in water; readily soluble in aprotic polar and organic solvents (e.g., DMSO, DMF, acetone, ethanol). Bright fluorescence only in nonpolar/hydrophobic media due to environment-sensitive quenching in water.
  • Spectral characteristics (environment dependent):
    • Absorption: typically in the 500–560 nm region depending on solvent polarity (literature).
    • Emission: strong solvatochromism—about green/yellow emission in nonpolar lipids (~570–600+ nm) shifting to red in more polar media (literature). Exact maxima depend strongly on microenvironment and formulation.
  • pKa/logP: often treated as a neutral, hydrophobic probe under staining conditions; reported high hydrophobicity (literature). Numerical values vary by source and are not provided here.

Practical implications:

  • Expect minimal fluorescence in bulk aqueous buffer; signal intensifies upon partitioning into lipid droplets/membranes.
  • Avoid interpreting exact peak positions without calibrating for the specific sample matrix and instrument settings.
Quality & Grades
  • Item grade: BioReagent. This generally denotes suitability for common life-science laboratory workflows (fluorescence imaging, staining, and related assays) with attention to background fluorescence and impurity levels appropriate for research use.
  • Purity specifications, stabilizers, and formulation details: Not specified for this item; refer to CoA/Spec Sheet.

What BioReagent grade means in practice (general guidance):

  • Fluorescence performance: Background autofluorescence from impurities is typically controlled so as not to compromise microscopy or flow measurements under recommended conditions.
  • Contaminants: Limits typically target low particulate and low metal/ionic contaminants that could quench fluorescence or induce photochemistry; exact limits are product-specific and not provided here.
  • Documentation: Lot-specific CoA may include functional QC (e.g., fluorescence spectrum or pass/fail staining test) and storage guidance to preserve signal integrity.

Implications for users:

  • For imaging and flow cytometry, BioReagent grade is typically sufficient. For highly quantitative spectroscopy, calibrate with your instrument and consider running a dye standard curve in your matrix.
  • If your application requires known exact concentration or solvent identity (e.g., for validated SOPs or GLP workflows), request the lot CoA/Spec Sheet to confirm formulation details.
Reaction & Applications

This product is intended for analytical staining rather than synthetic chemistry. Relevant applications (general/literature):

  • Lipid droplet visualization: Robust staining of neutral lipids (triacylglycerols, cholesteryl esters) in cells, tissues, yeasts, algae, and microplastics. Strong fluorescence upon partitioning into lipid-rich domains.
  • Membrane polarity sensing: Solvatochromism allows qualitative assessment of lipid order/polarity; emission shifts to longer wavelengths in more polar environments.
  • Flow cytometry and plate-based assays: After short incubations, cells can be analyzed for lipid content; excitation/emission filters should be selected according to the instrument (e.g., excitation ~530–560 nm with appropriate long-pass or band-pass emission filters; literature guidance).
  • Environmental/analytical use: Detection of hydrophobic polymer particles and oil contaminations; Nile Red adsorbs to nonpolar surfaces, enabling fluorescence-based identification (literature).

Practical tips (literature/practice):

  • Protect from light during handling and staining; minimize exposure time before imaging.
  • Work quickly in serum-free buffer to reduce nonspecific background; wash to remove unbound dye.
  • Optimize working concentration and incubation time empirically for each cell type/tissue and instrument. Excess dye can increase background and cytotoxicity.
  • For multicolor imaging, check spectral overlap with other fluorophores; Nile Red’s emission can bleed into TRITC/Texas Red channels depending on the microenvironment.

Note: Manufacturer-validated use cases for this specific SKU are not provided in the product data; consult the CoA/Spec Sheet and SDS for any item-specific recommendations.

Reaction Conditions

Not applicable to this product’s intended use. This is a staining solution for imaging/analytical workflows rather than a reagent for chemical reactions.

Operational conditions for staining (general/literature, not item-specific protocols):

  • Temperature: Ambient (room temperature) staining is common; some protocols prefer 37°C for live cells to maintain physiology. Avoid prolonged incubations that increase background or toxicity.
  • Light: Protect from light during preparation and incubation to reduce photobleaching.
  • Time and dose: Empirically optimize working concentration and incubation time to balance signal and background; excessive concentrations can cause nonspecific staining and cytotoxicity.
  • Washing: Use dye-free buffer to remove unbound dye prior to imaging or analysis.

Item-specific validated conditions, recommended concentrations, and incubation times are not provided for this SKU; consult the CoA/Spec Sheet and adapt literature methods to your system.

Safety & Handling

Item-specific hazard data (GHS/CLP) for SKU N1528891:

  • Signal word, hazard statements, pictograms, classification: Not specified for this item; refer to SDS.

General safety guidance for Nile Red staining solutions (literature/practice; not a substitute for the SDS):

  • Likely hazards: organic dye in an organic solvent (commonly DMSO, alcohol, or similar). Potential for eye/skin irritation; harmful if swallowed; organic solvent can facilitate dermal absorption of solutes. Treat as flammable if packaged in flammable solvent.
  • PPE: lab coat, nitrile gloves, safety glasses; handle inside a chemical fume hood to avoid inhalation of solvent vapors and aerosolized dye.
  • Incompatibilities: strong oxidizers; avoid strong acids/bases that may degrade the chromophore. Prevent contact with reactive reducing agents and peroxides.
  • Special risks: light sensitive—store and handle under subdued light or with amber containers to minimize photobleaching. Stains skin and surfaces; use spill pads and dedicated glassware.
  • First aid (overview):
    • Skin/eye contact: rinse with plenty of water for several minutes; remove contaminated clothing; seek medical attention if irritation persists.
    • Inhalation: move to fresh air; seek medical attention if symptoms occur.
    • Ingestion: rinse mouth; do not induce vomiting; seek medical attention.
  • Waste: collect dye-containing solutions and contaminated disposables as hazardous organic chemical waste per institutional and local regulations.

Always consult the product’s SDS and institutional EHS policies for authoritative instructions.

Solvent Selection

Applicability to this product:

  • This is a pre-formulated staining solution. The internal solvent system is not specified; refer to the CoA/Spec Sheet. Guidance below concerns use-phase media selection during staining and imaging (general/literature practices).

Key considerations for use-phase solvents/buffers:

  • Polarity: Nile Red is strongly environment-sensitive. Fluorescence is weak in bulk water but increases and blue-shifts in hydrophobic media (lipid droplets, membranes). Maintain aqueous buffers for biological integrity, but allow dye to partition into hydrophobic targets.
  • Typical aqueous buffers: PBS, HBSS, or balanced salt solutions without serum or detergents during staining to reduce background. Reintroduce serum/media after excess dye removal if compatible with your assay.
  • Organic cosolvent: If the stock/solution is DMSO- or ethanol-based, final working concentrations of organic solvent in the sample are commonly kept ≤0.1–1% v/v to minimize biological perturbation (literature guidance; verify with your system).
  • Detergents: Avoid nonionic detergents (e.g., Triton X-100) during staining—they can solubilize lipids and disrupt the partitioning that produces signal.

Comparison (literature, qualitative):

  • Nile Red vs BODIPY neutral lipid dyes: BODIPYs show narrower solvatochromism and often brighter signals with better-defined excitation/emission; Nile Red provides polarity-sensitive color shifts useful for ratiometric interpretation of lipid environments.
  • Nile Red vs Nile Blue: Nile Red is more hydrophobic and typically better for neutral lipid droplets; Nile Blue can label more polar lipid domains.
Storage & Reconstitution

Item-specific instructions:

  • Storage conditions: Store at -20°C (per product data). Keep tightly closed in original container.
  • Shipping: Shipped in an ice chest with ice pads (per product data).
  • Reconstitution: Not applicable/Not specified for this item; this is supplied as a staining solution. Refer to the label/CoA if dilution to a working solution is recommended.

General handling guidance for dye solutions (literature/practice):

  • Light sensitivity: Store in amber vials or protect the container from light to prevent photobleaching and degradation.
  • Freeze–thaw: Minimize freeze–thaw cycles; if multiple uses are expected, aliquot upon first thaw and refreeze promptly. Avoid repeated warming to room temperature.
  • Stability: Working solutions in aqueous buffers are typically prepared fresh to minimize background and photodegradation; discard if color/clarity changes or if precipitation appears.

Note: For definitive shelf-life, concentration, and solvent identity, consult the lot-specific CoA/Spec Sheet and SDS. This product is for research use only.

Structure & Identity
  • Item type: Pre-formulated fluorescence staining solution containing the hydrophobic dye commonly known as Nile Red. Specific composition and concentration for this SKU are not specified; refer to CoA/Spec Sheet.
  • SKU: N1528891; Grade: BioReagent.
  • CAS, CID, InChIKey, SMILES: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular formula and molecular weight: Not specified for this item; refer to CoA/Spec Sheet.

General/literature description of the chromophore (for context only):

  • Nile Red (also known as Nile Blue oxazone) is a phenoxazone-based, strongly solvatochromic fluorescent dye bearing a dialkylamino substituent. It preferentially partitions into hydrophobic environments (neutral lipids, membranes) where its fluorescence is bright and blue–yellow shifted relative to polar media.
  • Structural features (literature): fused tricyclic aromatic heteroaromatic core (phenoxazinone) with one ring nitrogen and ring oxygen; exocyclic carbonyl (–C=O) within the central ring; para-dialkylamino substituent that donates electron density, producing an internal push–pull system responsible for solvatochromism.
  • 2D structure (literature, qualitative): an extended planar, conjugated system with a carbonyl at the 5-position of the phenoxazinone core and a 9-position diethylamino (or similar dialkylamino) group; overall neutral in typical staining conditions.

Notes:

  • Because this product is a solution formulation, exact identifiers of the neat dye and any stabilizers/solvents are not provided here. Always consult the product label and CoA for item-specific identity data.
Synthetic Utility

Not typically applicable. Nile Red Fluorescent Staining Solution is intended for analytical staining in life-science workflows, not as a reagent or intermediate in chemical synthesis.

For completeness (general chemistry context):

  • The Nile Red chromophore represents a push–pull phenoxazinone scaffold of interest in dye chemistry and photophysics, but such transformations are carried out on the neat dye, not on pre-formulated staining solutions.
  • If you require Nile Red as a building block for derivatization (e.g., click handles, PEGylation), procure the neat dye or appropriate functionalized analogues rather than a ready-to-use staining solution.
Target Specificity
  • This product is not an antibody or affinity reagent. No antigen, clone, isotype, or species reactivity applies.
  • Item-specific binding targets or validated selectivity: Not specified for this item; refer to CoA/Spec Sheet.

General/literature context (for user expectations only):

  • Nile Red exhibits preferential accumulation and bright fluorescence in hydrophobic environments such as neutral lipid droplets and nonpolar membrane regions. Binding is driven by hydrophobic partitioning rather than specific molecular recognition.

Need help choosing the grade?

Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.

View BioReagent grade guide →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.