Platelet Dilution (Counting Solution) - BioReagent,Biological Stain,for microscopy

Cat. No.: P1511110
AVAILABLE TO ORDER
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. Biological Stain ? Biological stain grade — dyes characterized for staining cells and tissues. Use in histology and microscopy where staining consistency matters. for Microscopy ? Microscopy grade — reagents/stains suited to sample prep and imaging. Use in microscopy where clarity and low background are needed.
Synonyms
Platelet dilution | Platelet counting solution
Storage
Room temperature
Shipped In
Normal
Application
Cell analysis
 ·  off list, applied to all prices below.
Size
Status
Price
Qty
100ml
P1511110-100ml
1-2 wks(?)
Item is derived from our semi-finished stock and is processed in 1-2 weeks.
$19.90
500ml
P1511110-500ml
1-2 wks(?)
Item is derived from our semi-finished stock and is processed in 1-2 weeks.
$59.90
Enter a quantity for the sizes you want to add.
🧪

Why this grade

BioReagent,Biological Stain,for microscopy Biological Stain,BioReagent,for Microscopy for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Room temperature Ships Normal Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Overview

  Platelets are one of the formed elements in the blood of mammals. They are small, biologically active cytoplasmic fragments shed from the cytoplasm of mature megakaryocytes in the bone marrow through lysis. Platelets possess a specific morphological structure and biochemical composition, and play a crucial role in physiological and pathological processes such as hemostasis, wound healing, inflammatory response, thrombosis, and organ transplant rejection.

  Platelet Diluent is a type of solution that can lyse red blood cells in the blood while preserving the intact morphology of platelets. It is used to dilute blood samples, which are then loaded into a hemocytometer for the direct counting of platelets under a high-power microscope. This platelet diluent is for research use only and not intended for clinical diagnosis or any other applications.

Operating Procedures (For Reference Only):

1. Take a small test tube and add 0.38 mL of platelet diluent to it.

2. Use a clean, dry micropipette to draw 20 μL of capillary blood. Wipe off excess blood from the outside of the pipette, add the blood to the platelet diluent, aspirate the supernatant gently three times, and mix the solution thoroughly immediately.

3. After complete hemolysis, mix the solution again for 1 minute. Take one drop of the well-mixed platelet suspension and load it into the hemocytometer, taking care to avoid bubble formation or overflow. Let it stand at room temperature for 10–15 minutes to allow platelets to settle completely.

4. Place the hemocytometer under the high-power microscope of a light microscope, and count the number of platelets in five medium squares in total—i.e., the four corner medium squares and the central medium square within the large central counting square—one by one.

Calculation:

  Platelet count/L = Number of platelets in 5 medium squares × 10⁹/L

Precautions:

1. The needle puncture should be slightly deep. After wiping off the first drop of blood, collect blood for platelet counting first. Perform all operations rapidly to prevent platelet aggregation.

2. Complete platelet counting within 1 hour after blood collection to avoid interfering with the test results.

3. Ensure the small test tubes and hemocytometers are thoroughly clean to prevent misidentification of foreign particles as platelets.

4. Use moderate light during counting, and take care to distinguish refractive platelets from impurities.

5. Counting with a phase-contrast microscope yields better and more accurate results.

6. For your safety and health, wear a lab coat and disposable gloves during all operations.

Specifications

Synonyms
Platelet dilution | Platelet counting solution
Specifications & Purity
BioReagent, Biological Stain, for microscopy
Stability And Storage
Store at room temperature long term (12 months).
Storage
Room temperature
Shipped In
Normal
Grade
Biological Stain, BioReagent, for Microscopy

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificates(CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

2 results found

Lot NumberCertificate TypeDateItem
ZJ26F0332991Certificate of AnalysisMar 13, 2026 P1511110
ZJ26F0332992Certificate of AnalysisMar 13, 2026 P1511110
Solution Calculators
Reviews

Customer Reviews

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.