Stafia-1 is a potent STAT5a inhibitor ( K i =10.9 μM, IC 50 =22.2 μM). Stafia-1 displays high selectivity over STAT5b and other STAT family members
In Vitro
Stafia-1 shows at least 9-fold selectivity over STAT5b and higher selectivity against other STAT family members. MCE has not independently confirmed the accuracy of these methods. They are for reference only.
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Reviews
Customer Reviews
Application Protocols
Item-specific facts (from Product Data)
No tested application protocols are provided for Stafia-1.
General protocols for small-molecule testing (not item-specific)
Stock preparation: Dissolve in DMSO to 10–50 mM. Vortex/sonicate as needed. Aliquot into amber microvials and store at -20°C.
Biochemical enzyme assay: Prepare a 10-point 3-fold dilution series in assay buffer with constant DMSO (e.g., 0.1% v/v). Include vehicle control and a positive control inhibitor if available. Preincubate with enzyme if slow-binding behavior is suspected.
Cell-based assay: Dilute stocks into culture media to achieve ≤0.1–0.5% DMSO. Incubate for a defined period (e.g., 4–48 h depending on readout). Monitor cytotoxicity independently to decouple on-target effects.
Aggregation control: Include 0.01% nonionic detergent where compatible; run light scattering or enzyme counterscreens sensitive to colloids.
Data integrity: Confirm compound concentration by LC–UV or qNMR. Track lot/aliquot IDs and freeze–thaw count.
Note
These procedures are general best practices and not validated specifically for Stafia-1. Optimize conditions for your target and assay format.
Biological Roles
Item-specific facts (from Product Data)
No target, pathway, or biological function is specified for Stafia-1.
General context for small-molecule research probes (not item-specific)
Small molecules are widely used to modulate protein function transiently, enabling time-resolved interrogation of signaling pathways, enzyme mechanisms, and cellular phenotypes. They complement genetic perturbations by offering tunable dose and reversibility.
Typical experimental objectives include: establishing potency (IC50/EC50), mechanism of action (competitive, allosteric, covalent), and selectivity across protein families (kinases, GPCRs, enzymes) using standardized panels.
Off-target liabilities, redox activity, and colloidal aggregation are common artifacts that can masquerade as “biological roles.” Employ orthogonal counterscreens and biophysical assays to validate true target engagement.
Experimental considerations
Determine compound stability in assay media (serum, pH, light) and metabolic stability in S9 or microsomes when relevant to cellular experiments.
Measure permeability (PAMPA, Caco-2) and protein binding (plasma, media components) to contextualize cellular potency relative to free concentration.
Note
Because no biological role is provided for this item, users should treat Stafia-1 as an uncharacterized research tool and develop target/phenotype associations de novo.
Buffer Applications
Applicability
Stafia-1 is not a buffer reagent. No buffering capacity or buffer recipe information is provided for this item.
General guidance for dosing small molecules into buffers (not item-specific)
Prepare a concentrated DMSO stock (e.g., 10–50 mM) and dilute into prewarmed buffer to minimize precipitation; maintain final DMSO typically ≤0.1–0.5% v/v for cell-based assays or as dictated by the assay’s tolerance.
If the compound is ionizable and aqueous solubility is limited, adjust buffer pH to favor the ionized form (acidic compounds: pH ≥ 8; basic compounds: pH ≤ 6), within the constraints of biological compatibility.
Include low levels of nonionic surfactant (e.g., 0.01% Tween-20 or Triton X-100) in certain biochemical assays to reduce aggregation artifacts, if compatible with the readout.
Validate solution clarity visually and by quick analytical check (e.g., HPLC injection in assay buffer matrix) to confirm no precipitation or adsorption.
Note
All parameters above are general practice and not item-specific specifications. Refer to your assay SOPs for buffer composition and acceptable cosolvent levels.
Green Alternatives
Framing
With no structure-specific data for Stafia-1, green chemistry considerations focus on solvent choice, workup, and waste minimization during handling and assay preparation.
Greener solvent choices (general; not item-specific)
Prefer DMSO over DMF/NMP for stock solutions when possible; DMSO is considered relatively benign and has favorable environmental/health profiles compared with DMF/NMP.
Use ethanol or 2-propanol as cosolvents in place of methanol or acetonitrile when compatible with the assay.
For chromatographic purification, consider ethanol/water or ethyl acetate/Heptane in place of acetonitrile/THF, where resolution permits.
Illustrative comparison (literature, general)
DMSO vs DMF: DMSO is less volatile and less problematic toxicologically; DMF is effective but has stricter exposure concerns.
Ethyl acetate vs dichloromethane: EtOAc is less hazardous and biodegradable; DCM provides stronger elution but higher health/environmental impacts.
Operational practices
Scale down screening preparations; prepare only required aliquots to reduce waste.
Employ microplate-based preparations to minimize solvent volumes.
Consolidate waste streams (halogenated vs non-halogenated) for appropriate disposal.
Note
Green alternatives must remain subordinate to data quality and compound integrity. Validate solubility and assay performance after any solvent substitutions.
Pharmaceutical Uses
Item-specific facts (from Product Data)
No pharmacopeial status, excipient role, or formulation use is specified for Stafia-1.
General context (not item-specific)
As supplied, this product is designated for research use only. Without established clinical grade, GMP manufacturing controls, or compendial monographs, it is not intended for human or veterinary administration.
In early discovery, small molecules may be evaluated in preclinical research to explore exposure–response relationships, but such work requires institution-specific approvals and appropriate quality controls beyond the scope of this listing.
Formulation considerations for research (general)
For in vivo exploratory studies (where permitted), solubilization strategies often use vehicles such as PEG400/saline, Captisol, or acid/base adjusted aqueous solutions with co-solvents. These approaches must be developed case-by-case and validated for stability and tolerance.
Disclaimer
No pharmaceutical use, dosage, or clinical claim is made or implied for this item.
Physical Properties
Item-specific facts (from Product Data)
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Melting/boiling point, density, solubility, refractive index, pKa, logP: Not specified for this item; refer to CoA/Spec Sheet.
General/literature guidance (not item-specific)
Screening small molecules are commonly solids with melting points spanning 80–250 °C and show diverse polarity; however, this is highly structure-dependent.
A practical first-line dissolution sequence for unknown small molecules: DMSO > DMF > methanol/ethanol > acetonitrile > water with co-solvent and/or pH adjustment (if ionizable). This is general guidance and not a specification for this item.
If a structure is known, predicted properties (cLogP, pKa, TPSA) from computational tools can inform aqueous solubility and permeability expectations.
Analytical tips
If MP is unknown, a small-scale differential scanning calorimetry (DSC) or melting point determination helps assess crystallinity and potential polymorphism.
Solubility screening can be performed gravimetrically or by HPLC area vs known standards across cosolvent systems (e.g., water:cosolvent ratios of 90:10 to 50:50).
Quality & Grades
Item-specific facts (from Product Data)
Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
Context and expectations (general; not item-specific)
Research screening compounds are commonly supplied at ≥95% purity by HPLC with characterization by 1H NMR and MS; however, do not assume—verify on the item’s CoA.
If a stabilizer or counterion is used, it will be listed on the CoA; absence of such a note should not be taken as proof of absence.
What to check on receipt
Identity confirmation: compare LC–MS mass, retention time, and, if available, 1H NMR vs the CoA.
Purity: verify by orthogonal methods (HPLC-UV at multiple wavelengths, ELSD/RI, and, if chromophore-poor, qNMR).
Residual solvents, water, and inorganic salts: Not specified for this item; refer to CoA/Spec Sheet. If critical for your application, perform KF for water and GC for residuals.
Implications for use
For biological assays, impurities can confound SAR; consider rapid repurification if purity is below your internal threshold.
Document the exact lot number and CoA to ensure reproducibility across studies.
Reaction & Applications
Item-specific facts (from Product Data)
Manufacturer applications: Not provided beyond research-use context.
General research applications for small-molecule library members (not item-specific)
Chemical biology probes: May serve as starting points to interrogate protein function, signaling pathways, or phenotype via target engagement in vitro or in cells.
Screening and SAR: Suitable for primary/secondary screening, counter-screens, and early structure–activity relationship campaigns after resynthesis/analogs are available.
Target deconvolution workflows: Pair with thermal shift assays (DSF), CETSA, affinity capture (if a handle can be appended), or label-free MS-based chemoproteomics to identify potential targets.
Biophysical characterization: Use MST, ITC, DSF, SPR when solubility and chromophore properties allow.
Assay development tips (general)
Verify concentration by UV (if chromophore present) or quantitative NMR; avoid relying solely on gravimetry for hygroscopic/solvate-containing samples.
Control for assay interference: Include detergent to minimize aggregation artifacts; assess intrinsic fluorescence/absorbance; run redox/thiol-reactivity counterscreens.
Confirm reversibility and dose-response with orthogonal readouts; evaluate time-dependence to detect covalent or slow-binding behavior.
Important note
No specific biochemical target, potency, or selectivity data are provided for Stafia-1; users should establish these parameters experimentally.
Reaction Conditions
Applicability
No chemical reaction conditions are defined for Stafia-1 as a reagent. This section focuses on solution preparation and stability testing relevant to research use.
General preparation and stability assessment (not item-specific)
Stock solutions: Prepare 10–50 mM in anhydrous DMSO. Sonicate gently if needed. Filter through 0.22 µm PTFE for particulate removal.
Aqueous dilution: Add stock slowly into vigorously mixed buffer/media at room temperature or 37°C to avoid local supersaturation; verify that final DMSO is within assay tolerance.
Light and temperature: Until stability is known, protect from light (amber vials) and keep on ice during assay setup; return promptly to -20°C storage.
pH stability: If ionizable, test stability at pH 5, 7.4, and 9 over 24–48 h by LC–MS to detect hydrolysis/oxidation.
Freeze–thaw: Evaluate by repeated cycles (e.g., 3–5) and monitor potency/purity drift. Aliquot to minimize cycles.
Analytical controls
Use an internal standard in LC–MS to quantify recovery and monitor degradation products.
For colored/fluorescent compounds, acquire absorbance/fluorescence spectra to identify interference windows in optical assays.
Note
The above are general best practices and not specifications for this item.
Safety & Handling
Item-specific facts (from Product Data)
GHS Classification, Signal Word, Pictograms, H-Statements: Not specified for this item; refer to SDS.
Storage: Store at -20°C. Shipments are sent on ice packs to maintain low temperature.
General safety guidance (not item-specific; always defer to SDS)
Handle unknown small molecules with caution as “hazard not fully characterized.” Use lab coat, nitrile gloves, and safety glasses; work in a fume hood to avoid inhalation of dusts or solvent vapors.
Avoid skin contact, ingestion, and eye exposure. Consider DMSO solutions as facilitating dermal absorption; prevent skin contact with solutions.
Incompatibilities are structure-dependent; in the absence of data, keep dry, away from strong oxidizers and strong acids/bases, and protect from light until stability is confirmed.
First aid (general): If inhaled—move to fresh air; if on skin—wash with soap and water; if in eyes—rinse cautiously with water for several minutes; if swallowed—rinse mouth, seek medical advice. Provide SDS to medical personnel.
Waste: Collect solutions and solids as organic chemical waste. Do not discharge to the drain.
Risk management
Establish internal handling limits (e.g., ≤10 mM stock manipulations, closed containers, secondary containment) until potency/tox profile is known.
Perform preliminary stability tests (freeze–thaw, light, and pH exposure) on milligram quantities before scaling use.
Solvent Selection
Item-specific facts (from Product Data)
No solvent recommendations are specified for this item. Storage at -20°C is specified.
General dissolution strategy for small molecules (not item-specific)
Primary solvent: DMSO often provides the broadest solubility; prepare a concentrated stock (e.g., 10–50 mM) and dilute into assay media.
Secondary options: DMF, NMP for very nonpolar compounds; methanol or ethanol for moderately polar/neutral; acetonitrile as a mid-polar aprotic option.
Aqueous systems: If ionizable, adjust pH to favor the soluble form (bases: pH ≤ 6; acids: pH ≥ 8) while keeping final assay-compatible pH.
Cosolvent dilution: Maintain final DMSO in biological assays typically ≤0.1–0.5% v/v (general practice), using serial dilutions to avoid precipitation.
Comparison of common solvents (literature, general)
DMSO: Very high polarity/proticity parameter, miscible with water; biologically tolerated at low %; can carry compounds through membranes—use PPE.
DMF: Strong solvent power, miscible with water; less preferred in bioassays due to cytotoxicity at low %.
Ethanol/Methanol: Good for many heteroatom-rich molecules; miscible with water; volatility aids removal.
Acetonitrile: Useful for HPLC compatibility and intermediate polarity; lower solubilizing power than DMSO.
Practical tips
Filter 0.22 µm before use for aggregate-prone compounds.
Check for precipitation after dilution by visual inspection and analytical (HPLC/UPLC) confirmation.
Storage & Reconstitution
Item-specific facts (from Product Data)
Storage conditions: Store at -20°C.
Shipping: Ice chest with ice pads.
Appearance, formulated buffer, and reconstitution solvent: Not specified for this item; refer to CoA/Spec Sheet.
General guidance (not item-specific)
Upon receipt: Allow the sealed container to equilibrate to room temperature before opening to prevent moisture condensation if supplied as a solid. If moisture sensitivity is suspected, handle in a dry box or under inert gas.
Reconstitution: For most small molecules, dissolve in anhydrous DMSO to prepare a concentrated stock (e.g., 10–50 mM). If aqueous reconstitution is required, consider pH adjustment or co-solvents after confirming compatibility.
Aliquoting: Divide into single-use aliquots in amber vials or 96-well plates; minimize headspace and freeze at -20°C or below. Avoid repeated freeze–thaw cycles.
Stability: Until data are available, protect from light and avoid prolonged exposure to room temperature. Periodically verify integrity by HPLC/LC–MS after storage.
Handling on bench: Keep solutions on ice during setup; return promptly to freezer. Record preparation date, concentration, and solvent system on the label.
Research use only
This product is intended solely for research applications. For definitive stability and reconstitution instructions, consult the item’s CoA and SDS.
Structure & Identity
Item-specific facts (from Product Data)
Product name: Stafia-1 (SKU: S649602)
CAS: 2582757-90-0
Category: Small molecules and compound library entry (小分子和化合物库)
Storage: Store at -20°C; shipped in ice chest with ice pads
Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
InChIKey: Not specified for this item; refer to CoA/Spec Sheet.
General/literature notes (not item-specific)
“Stafia-1” is presented as a research small molecule. Without a disclosed structure, specific functional groups, ring systems, or stereochemistry cannot be described. If available from the CoA or SDS, include structural line notation (SMILES) to enable database cross-referencing, in silico predictions, and method development.
Practical guidance
If structural data become available, document: functional groups (e.g., amide, heteroaromatic), H-bond donor/acceptor counts, and any stereocenters. These parameters guide solubility strategy and analytical method selection (HPLC vs UHPLC, reverse- vs normal-phase).
Synthetic Utility
Applicability
Stafia-1 is supplied as a small-molecule library member for research use; no functional-group or building-block utility is provided.
General guidance (not item-specific)
If structural information becomes available and Stafia-1 contains elaboratable handles (e.g., halogen, anilide, nitrile, alkyne), it could be derivatized for SAR or conjugation (e.g., biotinylation, photoaffinity tags) to support target identification.
Stable isotopologues or linkable analogs may be prepared to facilitate LC–MS bioanalytical quantitation or chemoproteomic capture, respectively, but this requires knowledge of the underlying scaffold and reactive compatibility.
Analytical enablement
Prior to derivatization, assess purity and stability; establish an LC–MS method and, if needed, a chiral separation if stereocenters are present (unknown for this item).
Note
Without disclosed structure, no specific synthetic transformations can be recommended for Stafia-1.
Target Specificity
Item-specific facts (from Product Data)
Target, pathway, species reactivity, and binding data are not specified for Stafia-1.
Assess selectivity indices by comparing activity against close homologs or panel medians; confirm with dose–response curves and mechanism-of-action studies.
Note
No specific antigen/epitope/clone data apply; this product is a small molecule, not an antibody or biologic.
Frequently Asked Questions
What is the purity of this product?
This product is supplied at ≥99% purity (chemical assay). Lot-specific values are stated on the Certificate of Analysis.
How should this product be stored?
Store at ?20 °C. Freezer storage is required to maintain the specified shelf life.
How is this product shipped?
This product ships in an insulated container with ice pads. Unpack on arrival and transfer it to the storage condition stated above.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 2582757-90-0, the molecular formula is C24H27O10P, and the molecular weight is 506.44 g/mol.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
We use cookies to ensure the website functions properly and, where permitted, to improve your experience. You can manage your preferences at any time in Settings. Learn more in our Cookie Policy.
Shall we send you a message when we have discounts available?
Remind me later
Thank you! Please check your email inbox to confirm.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.