Uniform Polystyrene Microspheres - Color: red, Size: 7.0μm, 2.5%w/v in Water - ethanol (1:1, v/v), Matrix: polystyrene

Cat. No.: C196689
AVAILABLE TO ORDER
GRADE & PURITY Color: red, Size: 7.0μm, 2.5%w/v in Water - ethanol (1:1, v/v), Matrix: polystyrene
Storage
Room temperature
Shipped In
Normal
★
Size
Germany (EU)
USA*
Price
Qty
10ml
C196689-10ml
—
3 In stock

€353.95

€459.81
Save €105.86 (23.02%)
Enter a quantity for the sizes you want to add.

Specifications

Specifications & Purity
Color: red, Size: 7.0μm, 2.5%w/v in Water - ethanol (1:1, v/v), Matrix: polystyrene
Storage
Room temperature
Shipped In
Normal

Advanced Data

Certificates (CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

2 results found

Lot NumberCertificate TypeDateItem
G2213427G2213427Certificate of AnalysisJan 19, 2026 C196689
H1824077H1824077Certificate of AnalysisApr 26, 2022 C196689
Documents & Articles
Solution Calculators
Reviews

Customer Reviews

Application Protocols

No tested application protocols are provided for this specific item; refer to CoA/Spec Sheet. The following are general protocol outlines for polystyrene microspheres (literature/practice):

  • Resuspension of settled beads: gently invert/roll the container; if needed, brief low-power bath sonication (10–60 s) can help. Avoid probe sonicators at high power to prevent fragmentation.
  • Washing (aqueous systems): pellet by gentle centrifugation appropriate to bead size (e.g., 1–5 μm often 1,000–5,000 × g, 3–10 min; verify for your size), decant, and resuspend in filtered buffer. Add 0.01% nonionic surfactant if compatible.
  • Particle counting: dilute into filtered buffer to achieve 10⁴–10⁵ particles per frame (imaging) or appropriate concentrations for flow cytometers. Mix thoroughly to avoid sedimentation bias.
  • Passive adsorption (plain PS, literature): incubate protein in carbonate buffer pH ~9.2 or PBS at 4–25 °C for 1–2 h; wash and block with protein blocker. Optimize to minimize desorption and nonspecific binding.
  • Covalent coupling (carboxylated beads, literature): activate with freshly prepared EDC/NHS in MES buffer pH 5–6, couple ligand in PBS pH 7.2–7.4, then quench and block.

Important: exact bead size, surface chemistry, solids %, and preservatives critically determine centrifugal forces, buffer composition, and coupling conditions. Always adapt and verify with small-scale pilots.

Biological Roles

Polystyrene is a synthetic, non-biodegradable aromatic polymer with no intrinsic biological role. The microspheres are typically used as inert carriers or physical probes rather than bioactive components.

General considerations for bio-related research (literature; not item-specific):

  • Surface interactions: plain polystyrene is hydrophobic and tends to adsorb proteins nonspecifically via hydrophobic and π-interactions. This can be exploited for passive adsorption assays or mitigated by passivation (e.g., BSA, casein, PEGylation) or by using functionalized/charged surfaces.
  • Bioconjugation: carboxylated or aminated polystyrene beads can be derivatized via EDC/NHS, glutaraldehyde, epoxy, or click chemistries to immobilize biomolecules. Surface chemistry for this item is not specified.
  • Cellular applications: microspheres can serve as size standards, phagocytosis probes, or tracers in microscopy; ensure removal of preservatives/surfactants that may affect cells. Confirm sterility/endotoxin if used near biological systems.
  • Optical behavior: high refractive index and strong Mie scattering make polystyrene beads useful for instrument alignment and sensitivity checks in flow cytometry and microscopy.

Note: This product is for research use only. It is not intended for diagnostic or therapeutic use. Always verify endotoxin, sterility, preservatives, and surface chemistry on the CoA/Spec Sheet before use in biological contexts.

Buffer Applications

Polystyrene microspheres are not buffering agents and do not establish pH. Therefore, conventional buffer system selection (e.g., phosphate, Tris, HEPES) is not directly applicable to composition of the beads.

Practical notes when using beads in buffered media (general guidance):

  • Choose buffers that maintain colloidal stability for the specific surface chemistry (e.g., low ionic strength phosphate or HEPES for sulfate/carboxylated beads). Exact surface chemistry for this item is not specified; verify on CoA.
  • Avoid high salt or divalent cations that can screen charges and induce aggregation of charged beads.
  • Add nonionic surfactants (e.g., 0.01–0.05% Tween 20) only if compatible with your assay; surfactants may interfere with protein binding or enzyme activity.
  • Adjust pH to optimize coupling reactions (e.g., EDC/NHS coupling typically pH ~4.5–7.4, literature) if working with functionalized beads.
  • Filter buffers (0.2 μm) to minimize particulate contamination that complicates particle counting or imaging.
Green Alternatives

Selecting bead materials with lower environmental persistence or improved life-cycle profiles can be advantageous when application requirements permit. The following comparisons are general literature guidance and not specific to this item.

  • Biobased/biodegradable polymers:
    • Polylactic acid (PLA) or polycaprolactone (PCL) microspheres: biodegradable under suitable conditions; reduced long-term microplastic persistence. Tradeoffs: lower Tg or different solvent compatibility; mechanical stability and optical properties differ from polystyrene.
    • Cellulose or modified starch beads: renewable feedstock and hydrophilic surfaces; excellent for aqueous systems. Tradeoffs: narrower solvent window; lower refractive index.
  • Inorganic alternatives:
    • Silica microspheres: thermally stable, solvent-resistant, inherently hydrophilic, and often reusable. Tradeoffs: higher density (~2.0 g/cm³) changes settling behavior; different optical scattering.
  • Greener practice with polystyrene beads:
    • Minimize release to the environment; implement closed handling, filtration of waste streams, and capture of washings.
    • Prefer aqueous dispersions over volatile organic solvents when compatible with the application.
    • Reuse beads where possible (e.g., regeneration of affinity supports) to reduce consumption.

Comparison snapshot (general):

  • Polystyrene: high refractive index, versatile surface chemistry, broad availability; persistent microplastic; aromatic/chlorinated solvent reliance for processing.
  • Silica/Cellulose/PLA: improved environmental profile in many contexts but may require protocol adjustments for optical properties, density, or chemical durability.
Pharmaceutical Uses

No pharmacopeial grade or specific pharmaceutical designation is provided for this item; refer to CoA/Spec Sheet. The following information reflects general research/formulation contexts (not clinical claims):

  • Pre-formulation research: polystyrene microspheres can serve as model particulates for studying suspension behavior, rheology, syringeability, and device performance.
  • Assay development: solid supports for ligand immobilization in binding assays, immunoassays, or as reference materials for particle sizing instruments used in quality control labs.
  • Process development surrogates: inert tracers for scale-down studies of mixing, filtration, and separation processes.
  • Not typically used as excipients in approved human drug products due to non-biodegradability; biodegradable polymers (e.g., PLGA) are preferred for drug delivery applications (literature).

Key selection parameters for pharmaceutical R&D:

  • Particle size/CV and particle count accuracy for metrology.
  • Extractables/leachables and residual surfactants/preservatives.
  • Endotoxin/bioburden levels and sterilization method (if any).
  • Surface functionality and coupling capacity for ligand attachment.

This product is for research use only and not for human or animal therapeutic use. For GMP-related applications, request detailed quality documentation and lot-specific CoA.

Physical Properties

Item-specific physical properties (particle size, coefficient of variation, solids %, dispersant, and exact density) are Not specified for this item; refer to CoA/Spec Sheet.

General polystyrene properties (literature/computed guidance; not item specifications):

  • Appearance: typically white to off-white solid; microsphere dispersions appear milky to opalescent depending on size and concentration.
  • Density (bulk polymer, literature): ~1.04–1.06 g/cm³ at 25 °C. Effective density of microspheres in dispersion is influenced by trapped solvent and porosity.
  • Glass transition temperature Tg (literature): ~95–105 °C for atactic polystyrene; no true crystalline melting point (amorphous polymer).
  • Solubility (literature): insoluble in water; soluble in aromatic hydrocarbons (e.g., toluene, xylene) and chlorinated solvents (e.g., dichloromethane, chloroform). Swelling in THF and ethyl acetate is common; solubility depends on molecular weight and crosslinking.
  • Refractive index (bulk PS, literature): nD ~1.590 at 20–25 °C. This high index yields strong Mie scattering for submicron to micron spheres.
  • Zeta potential/charge: Not specified for this item; depends on surface functionalization and dispersant.
  • Particle size distribution: Not specified for this item; uniform spheres often exhibit CV ≤ 5% (literature), but this should not be assumed—verify on CoA.
  • Thermal behavior: softening above Tg; thermal degradation typically begins >280–300 °C in inert atmosphere (literature). Avoid prolonged heating near/above Tg to preserve size/shape.
Quality & Grades

Item-specific grade/purity is Not specified for this item; refer to CoA/Spec Sheet.

What “uniform” typically implies (literature/general):

  • Tight particle size distribution characterized by a low coefficient of variation (CV). High-quality metrology beads often target CV ≤ 5%, with best-in-class ≤ 3%. This item’s exact CV and size are not specified—verify on CoA.
  • Sphericity and smooth surfaces suitable for optical/flow applications.
  • Low residual monomer/surfactant levels for sensitive bioassays; exact residuals are not specified for this item.

Considerations when selecting a grade of polystyrene microspheres:

  • Surface functionality: plain (hydrophobic), sulfate or carboxyl for electrostatic stability and bioconjugation, amine/aldehyde/epoxy for covalent coupling. Surface type for this item is not specified.
  • Dispersion medium: water, buffered saline, or organic; solids %, preservative (e.g., sodium azide) and surfactant content are critical to application compatibility. Not specified for this item.
  • Optical quality: low fluorescence background and known refractive index are important for imaging/flow cytometry calibration; confirm on CoA.
  • Sterility/bioburden/endotoxin: for bioassays, some grades are sterile or low endotoxin; status is not specified here.

Always consult the CoA/Spec Sheet for the specific lot’s particle size, CV, solids content, surface chemistry, dispersion medium, and any stabilizers/preservatives.

Reaction & Applications

Manufacturer application text: Not provided. The following are general uses of uniform polystyrene microspheres (literature/practice; not specific to this item):

  • Calibration and sizing standards: particle sizing by DLS/NTA, single-particle optical scattering, image-based metrology, and flow cytometry (FSC/SSC) often employ uniform polystyrene beads with known diameters and refractive index. For quantitative work, exact diameter/CV must be taken from the CoA.
  • Assay carriers: after surface functionalization (e.g., carboxylate/amine), beads serve as solid supports for antibodies, oligonucleotides, or enzymes in immunoassays, agglutination tests, and lateral flow assay conjugates. Plain beads can be passivated to reduce nonspecific adsorption.
  • Microfluidics and rheology: tracer particles for velocimetry (μPIV), mixing studies, and viscoelasticity probes, leveraging refractive index and density near 1.05 g/cm³ (literature).
  • Materials templating: sacrificial templates for inverse opals or porous materials; removal by solvent dissolution or thermal treatment.
  • Separation technologies: with magnetic cores or after density modification, beads support bioseparations and affinity capture (general concept; this item is not specified as magnetic).

Practical tips:

  • Gentle dispersion: roll, invert, or briefly sonicate at low power to avoid fragmentation; avoid cavitation near or above Tg.
  • Avoid swelling solvents unless intentional; confirm dimensional stability experimentally.
  • For bioconjugation, verify surface chemistry and preservative content; azide or surfactants may interfere with coupling or biological assays.
  • Validate bead concentration (particles/mL) and solids % from CoA for quantitative protocols.
Reaction Conditions

No item-specific reactivity or functionalization conditions are provided; the following are general literature guidelines for modifying polystyrene microspheres. Always confirm compatibility with the actual surface chemistry and dispersion medium indicated on the CoA.

  • Chloromethylation (for subsequent nucleophilic substitutions): classical routes use chloromethyl methyl ether or safer surrogates with Lewis acids; conduct under strictly controlled conditions due to reagent hazards. Swollen beads in dichloroethane or toluene improve accessibility.
  • Sulfonation (to introduce –SO3H/–SO3− groups): fuming sulfuric acid or chlorosulfonic acid in inert solvents at low temperature; degree of sulfonation controls charge/catalytic acidity. Thorough quench and washing required.
  • Nitration/reduction: mixed acid nitration at low temperature followed by reduction to anilines allows further derivatization; monitor to prevent over-swelling and degradation.
  • Carboxylation routes: copolymerization with acrylic acids (during bead synthesis) or surface oxidation post-polymerization; for EDC/NHS coupling, typical buffers are MES (pH ~4.5–6) or PBS (pH 7.2–7.4), with freshly prepared carbodiimide solutions.
  • Metal deposition: sensitize (e.g., SnCl2/PdCl2) then electroless plate Ni/Cu/Au; control temperature and agitation to maintain monodispersity.
  • Protein coupling (carboxylated beads, literature): activate with EDC/NHS at 0–25 °C for 15–60 min; couple protein in suitable buffer (avoid primary amines if targeting carboxyl activation); block and wash thoroughly.

General tips: minimize aggressive swelling; maintain gentle stirring; verify bead integrity by microscopy/DLS before and after reactions.

Safety & Handling

Hazard classification for this specific item is Not specified; refer to the product SDS for authoritative information.

General safety considerations for polystyrene microspheres (literature/practice; not item-specific classifications):

  • GHS/Signal Word/Pictograms/H-statements: Not specified for this item; consult SDS.
  • Combustibility: polystyrene is a combustible polymer. Avoid ignition sources, hot surfaces, and finely dispersed dusts. Burning may release irritating smoke and styrenic compounds.
  • Particulate exposure: avoid inhalation of dust or aerosols; may cause mechanical irritation to eyes, skin, or respiratory tract. Use appropriate containment for powders and during sonication/spraying of dispersions.
  • PPE: lab coat, safety glasses, and suitable gloves. Use local exhaust ventilation when handling dry powders or when generating aerosols.
  • Incompatibilities (general): strong oxidizing agents; chlorosulfonic/sulfuric acids (sulfonation); halogenating/nitrating media; strong solvents at elevated temperature can swell/dissolve beads and alter size.
  • Environmental note: as microplastics, prevent release to drains and the environment. Collect and dispose of waste according to institutional and local regulations.
  • First aid (general guidance; defer to SDS):
    • Inhalation: move to fresh air; seek medical advice if symptoms persist.
    • Eye contact: rinse with water for several minutes; remove contact lenses if present and easy to do; seek attention if irritation persists.
    • Skin: wash with soap and water.
    • Ingestion: rinse mouth; do not induce vomiting; seek medical advice if unwell.
  • Spills: for dry powder, avoid dust generation; sweep with minimal disturbance. For dispersions, contain and wipe/absorb; prevent environmental release.
Solvent Selection

Solvent considerations depend on whether the microspheres are provided dry or as a dispersion (not specified for this item; refer to CoA/Spec Sheet).

General guidance for polystyrene (literature):

  • Water: bulk polystyrene is water-insoluble; plain beads are hydrophobic and may aggregate in salt-rich buffers. Sulfate/carboxyl-functional beads disperse better in aqueous media at suitable ionic strength and pH.
  • Good solvents/swelling media: toluene, xylene, chlorobenzene, dichloromethane, chloroform, and THF swell/dissolve polystyrene to varying degrees. Use with caution: swelling can irreversibly change particle size and surface properties.
  • Poor solvents: alkanes (hexane) and alcohols (ethanol, isopropanol) generally do not dissolve polystyrene but may be used for washing with limited swelling.
  • Buffer compatibility: phosphate or HEPES buffers at low-to-moderate ionic strength are commonly used for functionalized beads; surfactants (e.g., 0.01–0.1% Tween 20) can help maintain dispersion for hydrophobic surfaces.

When to choose alternatives:

  • For aqueous bioconjugation or cell-based assays, use hydrophilic/surface-functionalized polystyrene or silica/cellulose beads to reduce nonspecific binding.
  • For organic-phase synthesis or templating, polystyrene beads tolerate aromatic/chlorinated solvents but avoid prolonged exposure if dimensional fidelity is critical.

Small comparison (general):

  • Polystyrene vs silica: PS is lighter and higher refractive index; silica is more thermally/solvent robust and intrinsically hydrophilic.
  • Polystyrene vs PMMA: PS has higher refractive index and different surface chemistry; PMMA is often less prone to static but has lower Tg.
Storage & Reconstitution

Storage conditions (from Product Data):

  • Store at room temperature. Shipped under normal conditions.

Additional practical guidance (general; not item-specific requirements):

  • If supplied as an aqueous dispersion (not specified here), keep container tightly closed to prevent evaporation and contamination. Avoid freezing unless the CoA indicates freeze–thaw stability; freezing can cause aggregation or cracking.
  • If supplied dry, store in a clean, dry environment away from direct sunlight and heat sources. Protect from dust generation and static. Desiccation can help maintain flowability.
  • Avoid prolonged exposure to solvents that swell polystyrene (e.g., toluene, DCM, THF) unless intentional; swelling may irreversibly alter particle size.
  • Mix well before use: gently invert or roll to redisperse settled particles. For stubborn sediment, brief low-power bath sonication can assist. Do not vortex aggressively with large beads to avoid foaming and bubble entrapment.
  • Container compatibility: polystyrene beads can adhere to hydrophobic plastics; pre-wet surfaces with buffer containing a small amount of compatible surfactant if loss to walls is observed.
  • Shelf life: Not specified for this item; refer to CoA/Spec Sheet for recommended shelf life and any preservative content.

Disposal: Treat as laboratory plastic particulate waste. Collect and dispose of according to institutional guidelines to prevent environmental release.

Structure & Identity

Uniform Polystyrene Microspheres are spherical particles composed of polystyrene, a vinyl aromatic polymer derived from the monomer styrene.

  • Item-specific identifiers (CAS, SMILES, InChIKey, exact molecular formula/MW): Not specified for this item; refer to CoA/Spec Sheet.
  • Polymer repeat unit (literature): polystyrene consists of repeating styrene units with empirical repeat formula (C8H8)n. Average molecular weight is distributional and not defined by a single value for microspheres.
  • Structural features (general):
    • Backbone: saturated carbon chain (–CH2–CH(Ph)–)n with pendant phenyl rings on every other carbon.
    • Morphology: spherical particles; “uniform” typically implies narrow size distribution (low coefficient of variation), but the exact size and CV are not specified for this item; refer to CoA/Spec Sheet.
    • Stereochemistry: atactic polystyrene is most common for suspension/emulsion polymerization beads (literature). No defined stereocenters on the repeat unit beyond tacticity.
  • 2D description in words: a linear hydrocarbon backbone bearing phenyl substituents on alternating carbons; spheres are formed physically from this polymer, not by a unique covalent structure.
  • Surface chemistry: Not specified for this item (e.g., plain, sulfate-, carboxyl-, amino-functional). Surface groups, if any, critically affect colloidal stability and conjugation; consult the CoA/Spec Sheet for surface functionality.
  • Additives/stabilizers: Not specified for this item; refer to CoA/Spec Sheet.
Synthetic Utility

Uniform polystyrene microspheres can function as versatile solid supports and templates in synthetic chemistry and materials science (general literature guidance; not item-specific claims):

  • Solid support for heterogeneous synthesis: after surface functionalization (e.g., chloromethylation, sulfonation, nitration followed by further transformations), beads can bear catalytic or reactive groups. Crosslinked polystyrene supports are common in ion-exchange resins and phase-transfer catalysts.
  • Bioconjugation platform: carboxylated/aminated surfaces enable covalent immobilization of biomolecules via EDC/NHS, glutaraldehyde, epoxy, isothiocyanate, or click chemistries for assay construction.
  • Templating: monodisperse spheres assemble into colloidal crystals, serving as templates for inverse opals or periodic porous networks in ceramics, carbons, or oxides; removal by calcination or solvent dissolution.
  • Seeded growth: act as seeds for polymer shell growth (core–shell architectures) or metallization (e.g., electroless plating after surface activation) to yield composite particles.
  • Analytical standards: calibration of chromatographic particle analyzers, Coulter counters, and optical instruments.

Considerations:

  • Verify crosslinking level and surface chemistry on the CoA; crosslinking strongly influences solvent swelling, reaction accessibility, and dimensional stability.
  • Avoid aggressive conditions (strong oxidants, high temperatures above Tg) that deform spheres or alter surface.
  • Maintain dispersion quality during reactions to prevent aggregation and ensure uniform functionalization.
Target Specificity

Not applicable. This product is polymer microspheres, not a biological affinity reagent or antibody. No antigen/epitope specificity, clone, or isotype applies. For affinity applications, any target specificity would derive from ligands you conjugate to the bead surface, which are not part of this item. Refer to CoA/Spec Sheet for any surface functionalization details if provided.

Frequently Asked Questions

How should this product be stored?
Store at room temperature.
How is this product shipped?
This product ships under standard ambient conditions. No temperature-controlled packaging is required.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.