Uniform Polystyrene Microspheres - Color: red, Size: 10.0μm, 2.5%w/v in Water - ethanol (1:1, v/v), Matrix: polystyrene

Cat. No.: C196692
AVAILABLE TO ORDER
GRADE & PURITY Color: red, Size: 10.0μm, 2.5%w/v in Water - ethanol (1:1, v/v), Matrix: polystyrene
Storage
Room temperature
Shipped In
Normal
★
Size
Germany (EU)
USA*
Price
Qty
2ml
C196692-2ml
—
1 In stock

€133.55

€161.31
Save €27.77 (17.21%)
10ml
C196692-10ml
—
1 In stock

€390.40

€459.81
Save €69.42 (15.10%)
Enter a quantity for the sizes you want to add.

Specifications

Specifications & Purity
Color: red, Size: 10.0μm, 2.5%w/v in Water - ethanol (1:1, v/v), Matrix: polystyrene
Storage
Room temperature
Shipped In
Normal

Advanced Data

Certificates (CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

4 results found

Lot NumberCertificate TypeDateItem
C2613557C2613557Certificate of AnalysisJan 30, 2026 C196692
C2613561C2613561Certificate of AnalysisJan 30, 2026 C196692
E2422273E2422273Certificate of AnalysisMar 15, 2024 C196692
G2213528G2213528Certificate of AnalysisJun 16, 2022 C196692
Documents & Articles
Solution Calculators
Reviews

Customer Reviews

Application Protocols

Item-specific, validated protocols are not provided. The following general, literature-based procedures apply to polystyrene microspheres; adjust to your bead size/surface and application.

A. Redispersion of settled beads

  • Gently invert/roll the container for 1–2 minutes. If needed, bath-sonicate for 1–5 minutes. Avoid vigorous vortexing for large/fragile beads.
  • If aggregation persists, add 0.01–0.05% Tween 20 (compatibility permitting) and repeat.

B. Buffer exchange/washing

  • Centrifuge at an RCF appropriate to bead size (example: 2,000–10,000 g for 0.1–1 µm; 500–2,000 g for 1–10 µm) for 5–15 minutes.
  • Carefully decant supernatant. Resuspend pellets with gentle pipetting into fresh buffer. Repeat 2–3×.

C. Passive protein adsorption (for unmodified hydrophobic beads)

  • Prepare beads at 0.01–1% solids in carbonate buffer pH 9.2 or PBS.
  • Add protein to 10–100 µg/mg beads; incubate 1–2 h at RT with gentle mixing.
  • Wash 3× with buffer; block with 0.1–1% BSA or casein; store at 4 °C if compatible.

D. Counting/concentration estimation

  • For submicron beads, use NTA or flow cytometry; for micron beads, hemocytometer or imaging-based counts. Verify solids % by drying a known volume.

Always confirm surface chemistry and stability for your specific lot (Not specified for this item; refer to CoA/Spec Sheet).

Biological Roles

As synthetic polymeric particles, polystyrene microspheres do not have intrinsic biological roles or metabolic functions. However, they are widely used as inert supports and model particulates in biological research (literature/general):

  • Assay supports: serve as carriers for passive adsorption of proteins/antibodies via hydrophobic interactions or, when functionalized, for covalent immobilization (e.g., carboxylate beads with EDC/NHS coupling). Surface chemistry for this item is Not specified; confirm before use.
  • Cellular studies: size- and surface-controlled probes for phagocytosis/endocytosis mechanisms, mechanobiology, and cellular uptake modeling (ensure appropriate biocompatible coatings; observe biosafety practices).
  • Flow cytometry: size/fluorescence standards for instrument setup and compensation when labeled; unlabeled beads aid in scatter calibration due to high refractive index.
  • Immunology/microbiology: substrates for agglutination tests and latex tests (when appropriately functionalized/labelled); ensure compatibility with your biohazard and waste protocols.

Notes and cautions:

  • Endotoxin/bioburden: levels are process-dependent and item-specific; Not specified for this item—request CoA if critical.
  • Cytotoxicity: plain polystyrene is broadly biocompatible in vitro, but additives/residual monomer/surfactant or solvents can affect cells; perform controls.
  • Sterility: unless specifically sterilized and labeled as such, assume non-sterile; sterilization method compatibility (e.g., ethanol wash vs autoclave) depends on bead size/format and surface.
Buffer Applications

While not a buffering reagent, these microspheres are commonly suspended and processed in laboratory buffers. Practical, research-focused guidance (general):

  • Common media: DI water, PBS (pH 7.2–7.6), TBS, or assay-specific buffers. Add 0.01–0.1% nonionic surfactant (e.g., Tween 20) to reduce nonspecific aggregation and surface adsorption when beads are hydrophobic.
  • Ionic strength and pH:
    • Maintain moderate ionic strength (e.g., 10–150 mM) to balance electrostatic stabilization and assay needs; very high salt can induce flocculation for small beads.
    • Keep pH away from isoelectric point of any surface functionality to maximize colloidal stability (surface for this item Not specified).
  • Blocking agents:
    • For biomolecule work, block residual hydrophobic sites with 0.1–1% BSA, casein, or fish gelatin after adsorption/coupling; rinse thoroughly to reduce background.
  • Washing/exchange protocol (general):
    • Pellet gently (RCF depends on bead diameter; e.g., 2–10k g for 100–500 nm; lower RCF for micron beads), decant, and resuspend with slow pipetting or rolling. Avoid harsh vortexing for large beads.
  • Sterile handling:
    • If sterility is required, filter buffers (0.22 µm) and use aseptic technique. Do not autoclave polystyrene suspensions unless validated for your specific size/surface; heat can deform beads (Tg ~95–105 °C, literature).
Green Alternatives

Considering environmental footprint and solvent use, alternatives and practices can reduce impact while meeting performance needs (general/literature guidance):

  • Material alternatives:

    • Silica microspheres: inorganic, thermally robust, tolerate green aqueous processing, recyclable; tradeoff: higher density (sedimentation), different optical index (n≈1.45) vs PS (n≈1.59).
    • Biobased/biodegradable polymers (e.g., PLA/PLGA): reduced persistence; tradeoff: hydrolytic/thermal sensitivity, narrower solvent compatibility; optical index lower than PS.
    • PMMA beads: lower aromatic content; different solvent profile; slightly lower refractive index (≈1.49).
  • Process improvements with PS beads:

    • Prefer water-based buffers with low-toxicity surfactants; avoid aromatic/chlorinated solvents that swell/dissolve PS.
    • Implement closed-loop washing and solvent recovery for any necessary solvent steps.
    • Use gentle, energy-efficient dispersion methods (bath sonication vs probe, when feasible) to limit microplastic shedding.

Comparison snapshot (literature/general):

  • Polystyrene: high RI, excellent optical contrast; not biodegradable; sensitive to aromatics/chlorinated solvents.
  • Silica: green processing in water/alcohols; easy silanization; can be etched (HF) to template structures—requires HF precautions.
  • PLA/PLGA: biodegradable; suitable for bio-delivery research; softer, can deform; RI lower—less optical contrast.

Selection guidance: choose the substrate optimizing sustainability, optical needs, mechanical properties, and downstream disposal pathways.

Pharmaceutical Uses

No therapeutic or clinical claims are made. In pharmaceutical and diagnostic research/manufacturing contexts (general/literature):

  • Calibration and QC: used as particle size standards for instrument qualification (e.g., particle counters, flow cytometers) and process metrology.
  • Solid supports: platforms for assay development in immunodiagnostics (e.g., latex agglutination, lateral flow component evaluation) when beads are appropriately functionalized and validated.
  • Formulation/process development: model particulates for studying suspension stability, filtration, and device fouling in non-clinical studies.
  • Excipient status: Polystyrene microspheres are not typical pharmacopeial excipients for parenteral use; any use in drug product contexts requires rigorous safety/compatibility assessment and regulatory approval.

Item-specific regulatory grade/sterility/endotoxin: Not specified for this item; refer to CoA/Spec Sheet. For GMP-relevant work, request documentation on manufacturing controls, bioburden/endotoxin (if aqueous), and extractables/leachables. Ensure traceability of lot numbers and retain samples as part of internal QA programs.

Physical Properties

The following are either item-specific (when stated) or general/literature descriptors for polystyrene microspheres.

  • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Particle size, CV, concentration, dispersant: Not specified for this item; refer to CoA/Spec Sheet.
  • Density (bulk/true): ~1.04–1.06 g/cm³ for polystyrene (literature). Effective density of suspensions depends on medium and additives.
  • Glass transition (Tg): ~95–105 °C (literature). Above Tg, softened particles may deform under load.
  • Melting point: Amorphous polymer; no discrete Tm (literature).
  • Refractive index: ~1.59 at 589 nm for bulk polystyrene (literature); important for optical calibration/flow cytometry scattering.
  • Solubility (polymer): Insoluble in water; swells/soluble in many aromatic and chlorinated solvents (e.g., toluene, xylene, dichloromethane, chloroform); limited swelling in THF and ethyl acetate (literature). Dispersibility in water is governed by surface charge/surfactants.
  • Surface charge (zeta potential): Highly item-dependent; Not specified for this item; refer to CoA/Spec Sheet.
  • pKa: Not applicable to unfunctionalized polystyrene. If carboxylated or aminated surfaces are present, apparent pKa values are surface-chemistry dependent (not specified for this item).
  • UV–Vis: Polystyrene absorbs in the deep UV; scattering dominates visible spectra for micron/submicron beads (literature).
Quality & Grades
  • Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
  • What “Uniform” implies (general):
    • Monodispersity with a narrow size distribution (low coefficient of variation, CV). Many high-quality calibration beads target CV ≤ 5% or lower (literature), but the exact CV for this item is Not specified; refer to CoA.
    • Lot-to-lot consistency in mean diameter, concentration, and surface properties.
  • Surface chemistry: Not specified for this item. Uniform polystyrene microspheres may be offered as unmodified (hydrophobic), or surface-modified (e.g., sulfate-, carboxylate-, or amine-functional) to enhance colloidal stability and enable bioconjugation. Verify on the CoA/Spec Sheet.
  • Matrix/vehicle: Not specified for this item. Beads may ship as dry powder or as an aqueous suspension with stabilizers/preservatives; consult labeling.
  • Analytical controls typically applied to this class (general):
    • Particle sizing by DLS, NTA, or microscopy; concentration by gravimetry/UV or particle counting; zeta potential; residual surfactant; microbial control for aqueous suspensions.
  • Documentation and traceability:
    • Request lot-specific CoA for mean size, CV, concentration, dispersant composition, and recommended handling. Aladdin Scientific can provide supporting documents upon request to meet QA/QC and method validation needs.
Reaction & Applications

This product class is widely used as physical/analytical materials rather than reactants. Typical research applications (literature/general):

  • Calibration and metrology:
    • Flow cytometry and particle sizer calibration using known bead diameters and refractive index contrast.
    • Microscopy focus/PSF characterization; optical trapping benchmarks.
  • Assay development and separations:
    • Solid phase for adsorption-based immobilization of proteins/antibodies (on hydrophobic or appropriately modified surfaces).
    • Magnetic-free immunocapture or agglutination assays using density differences and sedimentation control.
  • Materials science:
    • Template-directed self-assembly into colloidal crystals/photonic structures; opal/Inverse opal templating.
    • Emulsion/ Pickering emulsion stabilizers where surface chemistry supports interfacial activity.
  • Microfluidics:
    • Channel characterization, flow visualization, and device calibration.

Practical tips (general):

  • Prevent aggregation: add 0.01–0.1% nonionic surfactant; avoid freeze–thaw; use gentle sonication (bath) to redisperse.
  • Washing/exchange: pellet by mild centrifugation appropriate to bead size (e.g., 2–10k g for submicron) and resuspend in the target buffer; avoid harsh vortexing for fragile, larger beads.
  • Bioconjugation: if beads are functionalized (carboxyl/amine/sulfate), standard EDC/NHS or glutaraldehyde chemistries can be used; surface type for this item is Not specified—verify before planning couplings.
Reaction Conditions

As polymer microspheres, these are not typically subjected to small-molecule reaction conditions in use. For surface modification and materials processing (literature/general guidance):

  • Physical processing:
    • Dispersion: bath sonication 1–10 min to break soft aggregates; avoid probe sonication for fragile/large beads. Gentle rolling/inversion preferred.
    • Assembly: evaporation-induced self-assembly on substrates (slow drying, controlled humidity) yields colloidal crystals; anneal near but below Tg to improve order without deformation.
  • Chemical modification (only if compatible with your specific beads; surface not specified for this item):
    • Sulfonation (conc. H2SO4 or fuming reagents) introduces –SO3H/–SO3− groups; strictly controlled conditions and safety measures required.
    • Chloromethylation (e.g., chloromethyl methyl ether alternatives, safer reagents) to introduce benzyl chlorides for subsequent substitution/grafting—observe stringent safety protocols.
    • Carbodiimide coupling (EDC/NHS) on carboxylated beads to attach amines; Schiff-base chemistry on aldehyde-modified beads.
  • Typical solvents: aqueous buffers for charged/functional beads; alcohols for pre-wetting; avoid aromatics/chlorinated solvents unless intentionally swelling or dissolving the PS.
  • Yields/outcomes: Highly system-dependent; verify by zeta potential shift, FTIR/XPS, dye binding, or functional assay.

Always consult the SDS/CoA for your lot and validate conditions at small scale before full implementation.

Safety & Handling
  • GHS classification, pictograms, signal word, H-statements: Not specified for this item; refer to SDS for authoritative safety information.
  • General polymer safety (literature/general):
    • Typically regarded as non-hazardous solid/aqueous dispersion. Avoid generating dust/aerosols; polymer dusts can be nuisance dust and, in rare cases, pose combustible dust hazards in confined spaces.
    • Thermal decomposition above ~280–300 °C can release irritating fumes (styrene, aromatic compounds). Avoid heating above the glass transition to prevent deformation/agglomeration.
  • Incompatibilities (general):
    • Swells/dissolves in aromatic or chlorinated solvents (toluene, xylene, DCM, chloroform); assess compatibility before contact with organic solvents or solvent-wetted labware.
    • Strong oxidizers may attack the polymer; concentrated acids can sulfonate the surface (literature).
  • PPE and handling:
    • Wear lab coat, safety glasses, and appropriate gloves. Use local exhaust ventilation when handling dry powders or when sonication may create aerosols.
    • Prevent bead aggregation by gentle inversion/rolling rather than vigorous vortexing unless validated for your particle size.
  • First aid (overview; defer to SDS):
    • Inhalation of dust: move to fresh air; seek medical advice if symptoms persist.
    • Eye/skin contact: rinse with water. Ingestion: rinse mouth; seek medical advice.
  • Environmental: Avoid release to drains; collect spills by wet wiping to minimize static/dust.
Solvent Selection

For polystyrene microspheres, the operative question is dispersion medium compatibility rather than solvent as a reagent.

  • Aqueous media (general guidance):
    • Water, PBS, TBS, and other physiological buffers are commonly used when surface charge or stabilizer enables dispersion. Add 0.01–0.1% nonionic surfactant (e.g., Tween 20) to mitigate aggregation for hydrophobic/bare beads (assess compatibility with downstream assays).
    • Avoid high ionic strength without surfactant for small (<500 nm) beads; screening of electrostatic repulsion can induce flocculation.
  • Organic solvents (compatibility; literature):
    • Aromatic (toluene, xylene) and many chlorinated solvents (DCM, chloroform) can swell/dissolve polystyrene—avoid for maintaining particle integrity.
    • Lower-swelling solvents (alcohols, acetone) may be used transiently for wetting/cleaning but can still alter surface or aggregation state; test at small scale.
  • Pre-wetting strategy:
    • If supplied dry and hydrophobic, pre-wet with ethanol or isopropanol, then stepwise exchange into water/buffer with surfactant to obtain a stable aqueous dispersion (general practice).
  • Comparison to alternatives (general):
    • Silica beads offer excellent solvent/thermal tolerance and easy silane chemistry but higher density (sedimentation). PMMA beads are less aromatic, lower RI, and different solvent compatibility.
  • Selection tip:
    • Choose the dispersion medium that matches your assay matrix, balancing colloidal stability, biomolecule compatibility, and avoidance of PS-swelling solvents.
Storage & Reconstitution
  • Storage temperature (from Product Data): Room temperature.
  • Shipped in: Normal (ambient) conditions per Product Data.
  • Light/moisture: Store in a closed container away from direct sunlight and dust. For aqueous suspensions, keep tightly sealed to minimize evaporation and contamination.
  • Do not freeze aqueous suspensions unless validated—freeze–thaw can induce irreversible aggregation or cracking of larger beads.
  • Matrix and preservatives: Not specified for this item; refer to CoA/Spec Sheet. If a preservative is present (e.g., low % sodium azide), follow institutional chemical hygiene and waste procedures.
  • Shelf life: Not specified for this item; monitor for aggregation, changes in dispersion behavior, or microbial growth (if aqueous) as indicators for replacement.
  • Reconstitution/redispersion (general):
    • If supplied as a dry powder: pre-wet with ethanol or IPA, then slowly add buffer with mild agitation to reach desired solids content; add 0.01–0.1% nonionic surfactant if compatible.
    • If supplied as a suspension: gently invert/roll to homogenize before aliquoting; brief bath sonication can help break soft agglomerates.
  • Compatibility: Avoid prolonged contact with aromatic/chlorinated solvents that swell/dissolve polystyrene. Validate container compatibility (HDPE/PP typically suitable; some solvents may craze polystyrene labware).
Structure & Identity

Uniform Polystyrene Microspheres are monodisperse polymer particles based on polystyrene, i.e., a polymer of styrene (vinylbenzene). As a polymeric material/dispersion, they do not possess a single small‑molecule structure.

  • Item-specific identifiers (CAS, InChIKey, SMILES, formula, MW): Not specified for this item; refer to CoA/Spec Sheet.
  • Polymer identity (literature/general):
    • Repeat unit: [–CH2–CH(Ph)–]n derived from styrene monomer (vinylbenzene).
    • Conceptual “2D structure” description: a saturated carbon backbone bearing pendant phenyl rings on every other carbon (atactic/racemic placement typical for free-radical polymerization). Microspheres are spherical assemblies of this polymer, optionally stabilized by residual surfactant or surface functionalities (not specified for this item).
  • Structural features (general):
    • Aromatic phenyl side groups impart hydrophobicity, high refractive index, and susceptibility to swelling in aromatic/chlorinated solvents (literature).
    • Surface chemistry determines colloidal behavior and conjugation options (e.g., bare/hydrophobic, sulfate-, carboxylate-, or amine-functional; not specified for this item).
  • Morphology: “Uniform” refers to tight particle size distribution (low CV) across the lot; exact mean size and CV are Not specified for this item; refer to CoA/Spec Sheet.
Synthetic Utility

Although not a reagent for molecular synthesis, polystyrene microspheres have considerable utility as materials in synthetic and materials chemistry (literature/general):

  • Solid templates: sacrificial templates for inverse opals/porous materials. Beads are assembled into colloidal crystals, infiltrated with an inorganic/organic precursor, then removed by calcination or solvent etching to create ordered macroporosity.
  • Heterogeneous supports: after suitable surface modification (e.g., chloromethylation, sulfonation, or grafting), beads can bear catalysts or ligands for phase-separable catalysis. For this item, surface functionality is Not specified; implement only if compatible.
  • Seeded polymerization: used as seeds for shell growth (core–shell particles), grafting-from polymerizations (e.g., SI-ATRP), or deposition of inorganic shells (silica, titania) to tune optics/mechanics.
  • Reaction controls: monodispersity enables systematic studies of diffusion, reaction at curved interfaces, and colloidal interaction potentials.

Practical notes:

  • Solvent caution: avoid aromatic/chlorinated solvents that swell/dissolve PS unless specifically needed for templating/etching steps; validate dimensional stability.
  • Thermal processing: polystyrene softens above Tg (~95–105 °C); thermal treatments for templating typically remove PS by oxidative calcination—ensure downstream material tolerates the schedule.
Target Specificity

Not applicable. This product is a polymeric microsphere material, not a biomolecular reagent with target/epitope specificity. No antibody or biological target information is provided for this item.

Frequently Asked Questions

How should this product be stored?
Store at room temperature.
How is this product shipped?
This product ships under standard ambient conditions. No temperature-controlled packaging is required.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.