1kb Ladder

Cat. No.: L665551
Disponível para encomenda
Storage
Store at -20°C
Shipped In
Ice chest + Ice pads
★
Tamanho
Alemanha (EU)
USA*
Preço
Qtd
100T
L665551-100T
Sob encomenda · 8–12 semanas

37,23€

43,30€
Gravar 6,07 € (14.03%)
500T
L665551-500T
Sob encomenda · 8–12 semanas

144,83€

169,12€
Gravar 24,30 € (14.37%)
Enter a quantity for the sizes you want to add.

Visão geral

The 1 kb Ladder consists of 8 DNA fragments, namely 1 kb, 2 kb, 3 kb, 4 kb, 5 kb, 6 kb, 8 kb, and 10 kb. This product is a DNA solution that already contains 1 x Loading Buffer, which can be taken as 5 μ Direct electrophoresis is very convenient to use; The amount of 5 kb DNA fragments during electrophoresis is about 150 ng, showing bright bands, while the amount of DNA in other bands is about 50 ng.

Component L665551 100 preps L665551 500 preps
1 kb Ladder 500 µl 5×500 µl

Notes:
1. This product can be directly thawed and mixed for use without heating.
2. Please replace the electrophoresis buffer in time and use the newly prepared agarose gel to avoid affecting the electrophoresis results.
3. During DNA agarose gel electrophoresis, the purity of gel has a great impact on the clarity of DNA bands, so try to use high-quality agarose. The recommended concentration of gel is 0.7% -1%, and the voltage is 4-8 v/cm.
4. The concentration of gel is closely related to the separation performance of DNA fragments. The higher the concentration of gel, the better the separation performance of short DNA fragments; On the contrary, the smaller the gel concentration, the more conducive to the separation of long DNA fragments.
5. When used in combination with macromolecular dyes, it is recommended to appropriately reduce the amount of Marker or increase the amount of dye used.

Usage:
Take 5 μ L Add it into the sample adding hole of agarose gel (if the sample adding hole is wider than 6 mm, the sample loading amount must be increased appropriately), and conduct electrophoresis.
Experimental results:


0.7% agarose gel electrophoresis (5 μ L)

Especificações

Condições de armazenamento de armazenamento
Store at -20°C
Enviado em
Ice chest + Ice pads
Este produto requer transporte de cadeia fria. Serviços terrestres e outros serviços econômicos não estão disponíveis.
Product Line
Produtos biológicos

Dados avançados

Certificados(CoA,COO,BSE/TSE e Mapa de Análise)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
FAQs e artigos
Calculadoras de soluções
Revisões

Avaliações dos Clientes

Application Protocols
  • Item-specific (Product Data)

    • Manufacturer protocols: Not specified for this item; refer to CoA/Spec Sheet.
  • General workflow (literature; adjust to your gel system)

    1. Thaw on ice and mix gently by pipetting; briefly spin to collect contents.
    2. If not pre‑mixed with loading dye, combine ladder with 6× loading buffer to 1× final just before loading.
    3. Load an appropriate volume per well (commonly a few microliters depending on ladder concentration, well size, and desired band intensity). Include at least one ladder lane per gel, ideally bracketing sample lanes.
    4. Run gel in TAE/TBE/SB at a suitable agarose percentage for the expected fragment sizes (see Reaction Conditions).
    5. Stain and image using a compatible nucleic acid dye and transilluminator; capture images within the linear dynamic range for densitometry if quantitation is required.
    6. Document gel with fragment size annotations; retain conditions (gel %, buffer, voltage, run time) for reproducibility.
  • Tips

    • Aliquot the ladder upon first thaw to avoid repeated freeze–thaw.
    • Use nuclease‑free tips and tubes; avoid contaminating the stock with sample DNA or enzymes.
Biological Roles

This product is a laboratory DNA standard and is not intended to play a biological role in living systems.

  • Item-specific (Product Data)

    • Intended use: For research use only (per Product Data).
  • General context (literature)

    • DNA nature: Consists of non‑coding double‑stranded DNA fragments used solely as electrophoretic size references.
    • No cellular function: Not designed for transfection, expression, or interaction with biological pathways.
    • Biosafety: As purified DNA, it poses minimal biosafety risk; however, observe standard BSL‑1 practices and institutional waste policies, especially when gels contain intercalating dyes.
Buffer Applications

Not a buffering reagent. However, its performance depends on the electrophoresis buffer used.

  • General guidance (literature)
    • Compatible systems: Commonly run in TAE or TBE for agarose gels; SB can be used for fast runs if resolution and staining are suitable.
    • pH control: Buffers near neutral to slightly basic (pH ~8.0–8.5) maintain DNA integrity and consistent migration.
    • Ionic strength: Excessive ionic strength increases heat and can distort bands; follow standard buffer recipes and dilution accuracy.
Green Alternatives

Although a 1 kb DNA ladder itself is not a solvent or reagent with a major environmental burden, workflows around its use can be greener.

  • Greener staining options (general/literature)

    • Replace ethidium bromide with safer intercalating dyes (e.g., SYBR‑class or other low‑toxicity stains) to reduce mutagenic waste.
  • Buffer/electrophoresis choices

    • Use low‑conductivity, rapid‑run buffers (e.g., SB) to cut run times and energy consumption, when compatible with your ladder and detection method.
  • Waste minimization

    • Cast thinner gels and optimize lane usage to reduce agarose and buffer volume.
    • Switch to blue‑light transilluminators to avoid UV exposure risks and extend stain lifetime.
  • Comparison snapshot (literature; not item-specific)

    • Ethidium bromide vs. safer stains: EtBr offers high sensitivity but is mutagenic and requires special disposal; safer stains lower hazard but may cost more and sometimes have different excitation/emission profiles.
    • TBE vs. TAE/SB: TBE offers sharper bands for small fragments but generates borate‑containing waste; TAE/SB can be faster and less energy‑intensive for larger fragments.
Pharmaceutical Uses

This product is a research‑use DNA size standard and is not used as an excipient or in pharmaceutical formulations.

  • Compliance note
    • No pharmacopeial monograph applies to mixed‑size DNA ladders. For regulated workflows, consult your quality unit and obtain item‑specific CoA/Spec Sheet and SDS.
Physical Properties
  • Item-specific (Product Data)

    • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
    • Concentration, buffer, dye content: Not specified for this item; refer to CoA/Spec Sheet.
  • General/literature values (for typical 1 kb DNA ladders; not item specifications)

    • Physical state: Aqueous solution (commonly in TE, Tris‑based, or proprietary buffers) or lyophilized; colorless to slightly tinted if pre‑dye is present.
    • Solubility: Fully miscible with water and standard electrophoresis buffers (TAE, TBE, SB).
    • Stability: dsDNA is stable at −20°C for long‑term storage; working aliquots are often kept at 4°C to −20°C to minimize freeze–thaw cycles.
    • pH: Typically near neutral (pH ~7–8) when in Tris‑based buffers (literature); exact pH depends on formulation.
    • UV absorbance: DNA exhibits a maximum at ~260 nm (A260) with A260/A280 ~1.8 for pure DNA (literature). These are general nucleic acid properties and not item specifications.
    • Viscosity/density: Similar to aqueous buffers at low DNA concentrations; may be higher if loading agents (e.g., glycerol, Ficoll) are included (literature).
Quality and Grades
  • Item-specific (Product Data)

    • Grade/purity: Not specified for this item; refer to CoA/Spec Sheet.
  • General considerations for DNA ladders (literature/typical)

    • Performance criteria: Sharp, well‑resolved bands across the stated size range; minimal smearing or satellite bands; consistent mass per band (if mass‑calibrated formulations).
    • Nuclease control: DNase/RNase‑free manufacturing and packaging are critical; many suppliers test for nuclease contamination.
    • Buffer system: Presence/absence of loading dye and density agents affects convenience. Pre‑mixed loading dye enables direct gel loading; dye‑free concentrates allow flexibility with fluorescent stains and downstream applications.
    • Photostability: Pre‑stained ladders may show altered mobility or band intensity; quality includes dye stability under illumination.
    • Documentation: A CoA should specify fragment sizes, approximate ng per band or per lane, recommended loading volume, and storage stability. Always consult the item’s specific CoA/Spec Sheet for definitive criteria.
Reaction and Applications
  • Primary application (item context)

    • Agarose gel electrophoresis size standard for double‑stranded DNA across kilobase ranges. Used to estimate fragment lengths and sometimes to approximate mass when mass‑calibrated ladders are employed.
  • Typical laboratory uses (general/literature)

    • Fragment sizing: Assess restriction digests, PCR products (long amplicons), ligation outcomes, plasmid linearization, and genomic DNA shearing profiles.
    • QC checkpoints: Monitor library construction, BAC/YAC preparation, or long‑range PCR by verifying expected size distributions.
    • Educational/training: Demonstrate gel electrophoresis principles and calibration.
  • Practical tips

    • Loading: Mix ladder with loading dye if not pre‑formulated; avoid overloading to prevent band merging/smearing.
    • Gel concentration: Choose agarose percentage appropriate to the size range (e.g., lower % for larger kb bands; see Reaction Conditions).
    • Imaging: Use appropriate stain and exposure to keep bands within the linear detection range; include a reference lane on each gel.
    • Handling: Keep on ice during use; aliquot to avoid repeated freeze–thaw cycles which can blunt band resolution.
    • Calibration: When accurate quantitation is needed, use a ladder with defined mass per band and image under identical conditions as samples.
Reaction Conditions

While not a reactant, the ladder’s performance depends on electrophoresis conditions.

  • General/literature guidance (not item specifications)
    • Gel matrix: Agarose concentration inversely correlates with resolvable fragment size. Typical ranges: ~0.7% for large kb fragments, ~1.0% for mid‑kb, ~1.5–2.0% for sub‑kb to ~2 kb. Choose lower % to resolve larger bands.
    • Running buffers: TAE (good for larger fragments and downstream recovery), TBE (high ionic strength/sharp bands for smaller fragments), SB (fast runs with lower heat).
    • Voltage/current: Moderate field strengths (e.g., ~4–10 V/cm measured between electrodes) balance resolution and run time; excessive voltage causes band smiling and heat.
    • Loading: Use sufficient density agent (e.g., glycerol or Ficoll in loading dye) to prevent sample loss from wells; avoid overloading to maintain discrete bands.
    • Staining/imaging: Post‑stain or pre‑cast staining per dye manufacturer; image under UV or blue light matched to the dye’s excitation.
    • Temperature: Running at room temperature is common; for very long runs or high voltage, consider cooling or recirculating buffer to limit thermal gradients.
Safety and Handling
  • Item-specific (Product Data)

    • GHS classification, pictograms, signal word, H‑statements: Not specified for this item; refer to SDS.
    • Storage condition: Store at −20°C (per Product Data).
    • Shipping: Shipped in ice chest with ice pads (per Product Data) to maintain cold chain.
  • General guidance (literature; defer to SDS/CoA)

    • Anticipated hazards: Most DNA ladders in aqueous buffers are generally considered non‑hazardous; however, formulations may contain dyes, salts, or preservatives—consult the SDS.
    • PPE: Laboratory coat, gloves, and eye protection when handling solutions and gels, especially when working with intercalating dyes and UV light.
    • Incompatibilities: Avoid nucleases (DNase) and nuclease‑contaminated consumables; maintain clean, nuclease‑free conditions. Do not mix with strong oxidizers or microbial contaminants.
    • Special risks: UV transillumination can cause skin/eye injury—use shields and appropriate eyewear. Ethidium bromide (if used for gel staining) is mutagenic—handle and dispose per institutional guidelines; consider safer stains.
    • First aid (overview): If skin/eye contact with staining reagents occurs, rinse with water for 15 minutes and seek medical attention per SDS. Ingestion/inhalation unlikely in normal use; follow institutional protocols.
Solvent Selection

This product is an aqueous DNA mixture rather than a solvent; classical solvent selection does not apply.

  • Item-specific (Product Data)

    • Formulation/solvent: Not specified for this item; refer to CoA/Spec Sheet.
  • Practical notes (general/literature)

    • Compatibility: Fully compatible with water and standard electrophoresis running buffers such as TAE, TBE, or SB. Avoid divalent cation contamination that can promote nuclease activity.
    • Additives: If not pre‑mixed with loading agents, add a compatible loading buffer (e.g., glycerol/Ficoll with tracking dyes) to reach sufficient density for well loading without diffusion.
    • Alternatives: For downstream cloning, choose dye‑free ladders in nuclease‑free buffer to minimize carryover of interfering dyes or salts.
Storage and Reconstitution
  • Item-specific (Product Data)

    • Storage conditions: Store at −20°C.
    • Shipping: Ice chest with ice pads to maintain temperature.
  • General guidance (literature; not item specifications)

    • Aliquoting: Divide into single‑use aliquots on receipt; repeated freeze–thaw can shear DNA and broaden bands.
    • Short‑term handling: Keep on ice during setup; return promptly to −20°C after use. Working aliquots may be stored at 4°C for limited periods if recommended by the CoA.
    • Reconstitution: If supplied lyophilized (check label), reconstitute with nuclease‑free water or the specified buffer to the stated concentration; mix gently to avoid shearing.
    • Stability: Many ladders remain stable for months at −20°C; verify lot‑specific expiry and stability on the CoA.
    • Light exposure: Protect from intense light if pre‑stained formulations are used.
    • Contamination control: Use DNase/RNase‑free consumables; avoid introducing loading dyes or stains into the stock vial.
Structure and Identity

A 1 kb Ladder is a DNA size standard composed of double‑stranded DNA fragments spanning kilobase lengths for calibration of nucleic acid electrophoresis.

  • Item-specific (Product Data)

    • SKU: L665551
    • Product Name: 1kb Ladder
    • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
    • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet. (Note: ladders contain a mixture of fragment sizes and do not have a single MW.)
    • CAS, CID, InChIKey, SMILES: Not specified for this item; DNA ladders are mixtures and typically do not have single identifiers.
  • General description (literature/typical)

    • Composition: Mixture of linear, double‑stranded DNA fragments at defined sizes near integer kilobases (e.g., ~0.5–10 kb or broader), often produced by restriction digestion or synthetic assembly.
    • Structural features: Standard B‑form dsDNA with phosphodiester backbone; fragments are non‑coding and sequence‑agnostic for sizing purposes.
    • Physical form: Supplied either as an aqueous solution in TE or similar buffer, sometimes with added loading dyes and density agents (varies by supplier; check label/CoA).
    • Visualization: Designed for staining with intercalating dyes (e.g., ethidium bromide or safer alternatives) or supplied pre‑stained in some formats.
Synthetic Utility

Not a synthetic building block or reagent. Its utility is analytical/QA for nucleic acid workflows.

  • Analytical utility (general/literature)
    • Serves as a molecular ruler to validate sizes of synthetic DNA constructs, plasmids, and long PCR products.
    • Indirect support for synthesis: Helps optimize restriction digests, ligations, and assembly reactions by confirming expected fragment distributions.
Target Specificity

Not applicable. A DNA ladder is a non‑targeted size standard and does not bind a biological target, antigen, or epitope.

Deseja que lhe enviemos uma mensagem quando tivermos descontos disponíveis?

Lembrar-me mais tarde

Obrigado! Por favor, verifique a sua caixa de entrada de e-mail para confirmar.

Ops! As notificações estão desativadas.