Reference materials and standards for analytical verification and quality control. Choose certified or traceable standards (where available) by analyte and application, and access documentation to support method development and compliance.
Reference Materials
Browse by type, application, or key specifications such as purity, grade, packaging, and handling requirements.
4,573 products
Popular Products
- Retinoic acidMoligand™ ? Moligand™ — Aladdin's line of ligands and bioactive small molecules. Use for receptor, pathway, and binding studies needing defined small-molecule tools. ≥98%In Stock Item #: R106320View ProductPricing & Pack Sizes
Technical Identifiers
- IUPAC Name
- (2E,4E,6E,8E)-3,7-dimethyl-9-(2,6,6-trimethylcyclohexen-1-yl)nona-2,4,6,8-tetraenoic acid
- SMILES
- CC1=C(C(CCC1)(C)C)C=CC(=CC=CC(=CC(=O)O)C)C
- InChIKey
- SHGAZHPCJJPHSC-YCNIQYBTSA-N
- InChI
- 1S/C20H28O2/c1-15(8-6-9-16(2)14-19(21)22)11-12-18-17(3)10-7-13-20(18,4)5/h6,8-9,11-12,14H,7,10,13H2,1-5H3,(H,21,22)/b9-6+,12-11+,15-8+,16-14+
- Synonyms
- (2E,4E,6E,8E)-3,7-dimethyl-9-(2,6,6-trimethylcyclohex-1-en-1-yl)nona-2,4,6,8-tetraenoic acid | TRETINOIN COMPONENT OF...
- Bisphenol A, Antagonist of Androgen receptor;Agonist of Estrogen receptor-βSolid Analytical standard ? Analytical standard — certified-purity material for quantitative calibration. Use to prepare calibration standards and validate analytical methods. Moligand™ ? Moligand™ — Aladdin's line of ligands and bioactive small molecules. Use for receptor, pathway, and binding studies needing defined small-molecule tools. for pharmaceutical anlysisIn Stock Item #: B108653View ProductPricing & Pack Sizes
Technical Identifiers
- IUPAC Name
- 4-[2-(4-hydroxyphenyl)propan-2-yl]phenol
- SMILES
- CC(C)(C1=CC=C(C=C1)O)C2=CC=C(C=C2)O
- InChIKey
- IISBACLAFKSPIT-UHFFFAOYSA-N
- InChI
- 1S/C15H16O2/c1-15(2,11-3-7-13(16)8-4-11)12-5-9-14(17)10-6-12/h3-10,16-17H,1-2H3
- Synonyms
- Bis(4-hydroxyphenyl) dimethylmethane | bis-phenol-a | Bisphenol-A | DTXCID30182 | 4,2-propane | 4,4'-Dihydroxdiphenyl...
- GentiopicrosideCAS: 20831-76-9 Formula: C16H20O9 Molecular Weight: 356.33Solid Analytical standard ? Analytical standard — certified-purity material for quantitative calibration. Use to prepare calibration standards and validate analytical methods. ≥98%In Stock Item #: G114059View ProductPricing & Pack Sizes
Technical Identifiers
- IUPAC Name
- (3S,4R)-4-ethenyl-3-[(2S,3R,4S,5S,6R)-3,4,5-trihydroxy-6-(hydroxymethyl)oxan-2-yl]oxy-4,6-dihydro-3H-pyrano[3,4-c]pyran-8-one
- SMILES
- C=C[C@H]1[C@H](O[C@]2([H])O[C@H](CO)[C@@H](O)[C@H](O)[C@H]2O)OC=C3C(OCC=C31)=O
- InChIKey
- DUAGQYUORDTXOR-GPQRQXLASA-N
- InChI
- 1S/C16H20O9/c1-2-7-8-3-4-22-14(21)9(8)6-23-15(7)25-16-13(20)12(19)11(18)10(5-17)24-16/h2-3,6-7,10-13,15-20H,1,4-5H2/t7-,10-,11-,12+,13-,15+,16+/m1/s1
- Synonyms
- (3S,4R)-4-ethenyl-3-[(2S,3R,4S,5S,6R)-3,4,5-trihydroxy-6-(hydroxymethyl)oxan-2-yl]oxy-4,6-dihydro-3H-pyrano[3,4-c]pyr...
- Five canions mixed standard ( Sodium,Ammonium,Potassium, Magnesium,Calcium )100μg/mL in H2O,Uncertainty:2%In Stock Item #: BWW292924View ProductPricing & Pack Sizes
Technical Identifiers
- Fluoride Ion Selective Electrode Solutions1000ppm StandardIn Stock Item #: I123834View ProductPricing & Pack Sizes
Technical Identifiers
- Synonyms
- Fluoride electrode solution
- DimethoateAnalytical standard ? Analytical standard — certified-purity material for quantitative calibration. Use to prepare calibration standards and validate analytical methods.In Stock Item #: D109819View ProductPricing & Pack Sizes
Technical Identifiers
- IUPAC Name
- 2-dimethoxyphosphinothioylsulfanyl-N-methylacetamide
- SMILES
- CNC(=O)CSP(=S)(OC)OC
- InChIKey
- MCWXGJITAZMZEV-UHFFFAOYSA-N
- InChI
- 1S/C5H12NO3PS2/c1-6-5(7)4-12-10(11,8-2)9-3/h4H2,1-3H3,(H,6,7)
- Synonyms
- dimethoate|60-51-5|Phosphamide|Rogor|Phosphamid|Lurgo|Perfecthion|Perfekthion|Daphene|Dimeton|Dimevur|Fosfotox|Racusa...
- Iodide anion standard solution1mg/ml (1,000ppm)In Stock Item #: A299227View ProductPricing & Pack Sizes
Technical Identifiers
- Synonyms
- AMMONIUM IODIDE [MI] | H4IN | UNII-OZ8F027LDH | HSDB 476 | MFCD00011424 | Ammonium jodatum | EINECS 234-717-7 | SY009...
- Cadmium Ion Selective Electrode Solutions0.1 M StandardIn Stock Item #: I123813View ProductPricing & Pack Sizes
Technical Identifiers
- Synonyms
- Cadmium ion electrode solution
- Zinc standard1000mg/L Zn in 1%HClOut of Stock Item #: Z117294View ProductPricing & Pack Sizes
Technical Identifiers
- Carbon Dioxide (Carbonate) Ion Selective Electrode Solutions0.1 M StandardIn Stock Item #: I123815View ProductPricing & Pack Sizes
Technical Identifiers
- Synonyms
- Carbon dioxide (carbonate) ion electrode solution
- Aqueous electrolytic conductivity-KCl40000μS/cm(25℃)in H2O,Uncertainty:0.25%In Stock Item #: BWW395892View ProductPricing & Pack Sizes
Technical Identifiers
- Synonyms
- Potassium chloride
- Aqueous electrolytic conductivity-KCl100000μS/cm(25℃)in H2O,Uncertainty:0.25%In Stock Item #: BWW396848View ProductPricing & Pack Sizes
Technical Identifiers
- Synonyms
- Potassium chloride
Fast Shipping Same-day shipping on in-stock items
Technical Details Quality & specification info on every product page
Pack Size Options Multiple packaging sizes with pricing access from listing
R&D Use Only Products supplied for research and development use
Frequently Asked Questions
How do I choose the right reference standard for my method?
Match the standard to your analytical technique (HPLC, GC, MS) and method requirements (USP, EP, JP, in-house). Verify traceability, certificate of analysis, expiration date, and storage requirements before use.
What documentation comes with reference materials?
Each reference material includes a certificate of analysis with assigned value, measurement uncertainty, traceability statement, expiration date, and storage conditions. Pharmacopoeia-compliant standards include compendial method references.
What specifications matter most for analytical standards?
Assigned purity and uncertainty, traceability to primary standards, expiration date, storage conditions (often -20°C or 4°C), pack size matching method requirements, and compliance with applicable pharmacopoeia.
How should reference materials be stored after opening?
Most reference materials should be stored at the conditions specified on the certificate (typically -20°C to 4°C), protected from light and moisture. Once opened, use within the period stated by the manufacturer to maintain assigned value validity.







