Annexin V-APC/DAPI Apoptosis Detection Kit - BioReagent, Biological Stain, for microscopy, Suitable for Immunofluorescence(IF), ready-to-use, high purity

Cat. No.: A1456534
Disponível para encomenda
GRAU & PUREZA Suitable for Immunofluorescence(IF) ? IF grade — validated for immunofluorescence with low background staining. Use to localize targets in cells/tissue by fluorescence microscopy. BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. Ready-to-use ? Ready-to-use — supplied pre-formulated at working concentration, no prep needed. Use to save time and reduce pipetting/dilution errors. Biological Stain ? Biological stain grade — dyes characterized for staining cells and tissues. Use in histology and microscopy where staining consistency matters. for Microscopy ? Microscopy grade — reagents/stains suited to sample prep and imaging. Use in microscopy where clarity and low background are needed.
★
Tamanho
Alemanha (EU)
USA*
Preço
Qtd
20T
A1456534-20T
Sob encomenda · 8–12 semanas
164,78€
50T
A1456534-50T
Sob encomenda · 8–12 semanas
277,59€
100T
A1456534-100T
Sob encomenda · 8–12 semanas
433,78€
200T
A1456534-200T
Sob encomenda · 8–12 semanas
694,10€
Enter a quantity for the sizes you want to add.
🧪
Por que este grau

Suitable for Immunofluorescence(IF), BioReagent, ready-to-use, Biological Stain, for microscopy Biological Stain,BioReagent,for Microscopy,Ready-to-use,Suitable for Immunofluorescence(IF) para fluxos de trabalho cromatográficos e analíticos sensíveis que exigem interferência mínima da linha de base.

🌡

Armazenamento e envio

Store at 2-8°C,Protected from light Envio Wet ice. Consulte o COA específico do lote para obter as especificações exatas.

📋

Documentos de qualidade

SDS, COA, ficha técnica e folha de especificações disponíveis para download. COA específico do lote acessível por meio de pesquisa por número de lote.

📚

Comprovação documental

Citado em 0 publicações revisadas por pares nas áreas de cromatografia, síntese orgânica e reações de acoplamento cruzado.

Visão geral

  Annexins are a family of calcium-dependent phospholipid-binding proteins that preferentially bind phosphatidylserine (PS). Under normal physiologic conditions, PS is predominantly located in the inner leaflet of the plasma membrane. Upon initiation of apoptosis, PS loses its asymmetric distribution across the phospholipid bilayer and is translocated to the extracellular membrane leaflet marking cells as targets of phagocytosis. Once on the outer surface of the membrane, PS can be detected by fluorescently labeled Annexin V in a calcium-dependent manner.

  In early-stage apoptosis, the plasma membrane excludes viability dyes such as 4',6-diamidino-2-phenylindole (DAPI), propidium iodide (PI), 7-AAD. These cells will stain with Annexin V but not a viability dye, thus distinguishing cells in early apoptosis. However, in late stage apoptosis, the cell membrane loses integrity thereby allowing Annexin V to also access PS in the interior of the cell. A viability dye can be used to resolve these late-stage apoptotic and necrotic cells (Annexin V, viability dye-positive) from the early-stage apoptotic cells (Annexin V positive, viability dye-negative).

This kit is suitable for the identification and enumeration of dead cells, such as apoptotic or necrotic cells, by flow cytometry.

Instruction for use

1.  Dilute 10x Binding Buffer to 1x using distilled water (1 mL 10x Binding Buffer + 9 mL ddH2O).

2.  Wash cells twice with cold PBS and then resuspend the desired amount of cells in Annexin V Binding Buffer at a concentration of 0.5-1.0x106 cells /mL.

3.  Add 5 μL of Annexin V-APC and 2 μL of DAPI staining solution to 100 μL of cell suspension.

4.  Add 100 µLof 1x Binding Buffer to each assay.  Gently vortex the cells and incubate for 10 min at RT (25°C) in the dark.

Precautions

1. Please try to avoid light when using to slow down the quenching of fluorescence.

2. DAPI Solution is toxigenic and mutagenic; handle with care.

3. Due to the calcium dependence of the Annexin V:PS interaction, it is critical to avoid buffers containing EDTA or other calcium chelators during Annexin V experiments.

Especificações

Sinónimos
Annexin V-APC/DAPI Apoptosis Kit | Annexin V-APC Assay Kit
Especificações e pureza
Suitable for Immunofluorescence(IF), BioReagent, ready-to-use, Biological Stain, for microscopy
Grau
Biological Stain, BioReagent, for Microscopy, Ready-to-use, Suitable for Immunofluorescence(IF)
Aplicação
Apoptosis, Flow Cytometry, IF/ICC
Sensibilidade
light-sensitive
Armazenamento e envio
Condições de armazenamento de armazenamento
Store at 2-8°C,Protected from light
Enviado em
Wet ice
Estabilidade e armazenamento
Store at 2-8℃ long term (12 months)
Contents & Storage

A1456534

Components

20 T

50 T

100 T

Storage

Quantity Per Test

A1456534A

10× Annexin V Binding Buffer

5 mL

10 mL

20 mL

2-8℃

200 μL per  0.5-1.0x105 cells

A1456534B

Annexin V-APC

100 μL

250 μL

500 μL

2-8℃. Store in the dark.

5 μL per  0.5-1.0x105 cells

A1456534C

DAPI Staining Solution

40 μL

100 μL

200 μL

2-8℃. Store in the dark.

2 μL per 0.5-1.0x105 cells

Note: The recommended number of cells to stain per test is 0.5-1.0x10⁵ cells.
Imagens

Annexin V-APC/DAPI Apoptosis Detection Kit (A1456534) - Flow Cytometry
Flow cytometric analysis was performed on Jurkat cells, either untreated (left panel) or treated with 2 µM camptothecin (C111281) for 16 hours (right panel), using the Annexin V-APC/DAPI Apoptosis Detection Kit (A1456534).
The cells were stained with Annexin V-APC and DAPI and then analyzed. In the untreated sample (left panel), the majority of cells were negative for both Annexin V-APC and DAPI, indicating a viable, non-apoptotic population. Following the 16-hour treatment with camptothecin (right panel), three main cell populations were identified:
1. Viable, non-apoptotic cells: Annexin V-APC negative/DAPI negative.
2. Early apoptotic cells: Annexin V-APC positive/DAPI negative.
3. Late apoptotic and dead cells: Annexin V-APC positive/DAPI positive.

Documentação

📋 Ficha de dados de segurança (FDS)

Documento abrangente sobre perigos, manuseamento, armazenamento e conformidade regulamentar.

<<<<<<< HEAD Baixar SDS → ======= Baixar SDS → >>>>>>> release248-p3

✅ Certificado de análise (COA)

Dados de qualidade específicos do lote. Introduza o número de lote para obter o COA exato.

Consultar COA →

📊 Ficha técnica

Resumo de referência rápida das especificações e aplicações do produto.

Ver ficha técnica →

🔬 Folha de especificações

Atributos de qualidade completos e critérios de aceitação para este grau.

Ver folha de especificações →

Dados avançados

Certificados(CoA,COO,BSE/TSE e Mapa de Análise)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

3 results found

Lot NumberCertificate TypeDataItem
ZJ26F0332435ZJ26F0332435Certificate of AnalysisMar 06, 2026 A1456534
ZJ26F0332436ZJ26F0332436Certificate of AnalysisMar 06, 2026 A1456534
ZJ26F0332437ZJ26F0332437Certificate of AnalysisMar 06, 2026 A1456534
FAQs e artigos
Calculadoras de soluções
Revisões

Avaliações dos Clientes

Perguntas frequentes

What does Suitable for Immunofluorescence(IF) mean?
Suitable for Immunofluorescence(IF) indicates the product has been validated for use in immunoassays such as ELISA, IF, IHC and flow cytometry. Validation may include positive/negative control samples, signal-to-noise testing, and protocol-specific QC. Lot-specific test data is published on the Certificate of Analysis where available.
What does BioReagent mean?
BioReagent indicates that the product has been processed and tested for biological and biochemical applications. Specifications may include endotoxin limits, microbial controls, sterility, low DNase/RNase/protease activity, and verified biological activity where relevant.
How should this product be stored?
Store at 2–8 °C, protected from light. The material is light-sensitive — keep it in its original opaque or amber container.
How is this product shipped?
This product ships chilled on wet ice. Unpack on arrival and transfer it to the storage condition stated above.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Deseja que lhe enviemos uma mensagem quando tivermos descontos disponíveis?

Lembrar-me mais tarde

Obrigado! Por favor, verifique a sua caixa de entrada de e-mail para confirmar.

Ops! As notificações estão desativadas.