Magnetic adsorbent - Matrix:SiO2,Surface group:-SO3HSize:3-4um,unit:10mg/ml

Cat. No.: M121923
Disponível para encomenda
GRAU & PUREZA Matrix:SiO2,Surface group:-SO3HSize:3-4um,unit:10mg/ml
Storage
Room temperature
Shipped In
Normal
★
Tamanho
Alemanha (EU)
USA*
Preço
Qtd
5ml
M121923-5ml
—
2 Em stock

137,88€

179,54€
Gravar 41,65 € (23.20%)
Enter a quantity for the sizes you want to add.

Especificações

Especificações e pureza
Matrix:SiO2,Surface group:-SO3HSize:3-4um,unit:10mg/ml
Condições de armazenamento de armazenamento
Room temperature
Enviado em
Normal

Dados avançados

Certificados(CoA,COO,BSE/TSE e Mapa de Análise)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate TypeDataItem
G2228799G2228799Certificate of AnalysisJul 13, 2022 M121923
Calculadoras de soluções
Revisões

Avaliações dos Clientes

Application Protocols

Item-specific validated protocols: Not specified for this item; refer to CoA/Spec Sheet.

General protocols (adapt to surface chemistry):

  • Batch adsorption and cleanup (generic):
    1. Pre-equilibrate beads in working buffer/solvent; remove supernatant magnetically.
    2. Add sample (suggested 5–50 mg beads per mL). Mix end-over-end 5–30 min.
    3. Magnetically capture; decant supernatant.
    4. Wash 1–3× with buffer/solvent to remove unbound matrix components.
    5. Elute target (pH/salt/solvent change) or discard beads if scavenging impurities.
  • Metal scavenging (example): treat reaction mixture diluted in suitable solvent (e.g., MeOH, MeCN, or toluene depending on coating compatibility). Mix 10–30 min; separate magnetically; assay residual metal by ICP-MS.
  • Nucleic acid cleanup (SPRI-like; if silica/PEG-compatible): mix sample with 1.0–1.8× bead suspension and PEG/NaCl binding buffer; incubate 5–10 min; magnetically clear; wash twice with 70–80% ethanol; air-dry briefly; elute in TE or water.

Tips:

  • Avoid strong magnets placed abruptly against thin glass to prevent bead compaction and loss.
  • For viscous samples, extend mixing and consider gentle sonication if permitted by coating.
  • Pre-filter gross particulates to protect bead surfaces and improve mass transfer.
Biological Roles

Item-specific biological attributes: Not specified for this item; refer to CoA/Spec Sheet for any bio-affinity functionalization.

General context:

  • Magnetic adsorbents are not biological macromolecules and have no intrinsic metabolic role. Their relevance in biology is as tools for separation and purification when functionalized with appropriate ligands.
  • Typical bio-oriented uses (literature/examples):
    • Nucleic acid workflows: selective binding of DNA/RNA in the presence of PEG/NaCl or chaotropes, followed by magnetic washing and elution.
    • Protein purification: affinity (e.g., Ni–NTA for His6 tags, streptavidin–biotin systems), ion exchange (–COO−, –NR3+), or hydrophobic interaction surfaces.
    • Cell separation: beads bearing antibodies/lectins for positive/negative selection; requires well-defined biocompatible coatings and gentle magnetic handling.
  • Considerations: endotoxin levels, preservative content, and cytotoxicity of coatings/ligands are critical for sensitive biological assays but are product-specific and must be verified before use.

Note: No clinical or therapeutic claims are made. For research use only (per product data). Suitability for live-cell or sensitive biomolecule work depends on the specific surface chemistry and cleanliness of the supplied material.

Buffer Applications

Item-specific buffer recommendations: Not specified for this item; refer to CoA/Spec Sheet.

General guidance by functionality (literature):

  • Ion exchange surfaces:
    • Anion exchangers (quaternary ammonium): bind at pH where target is negatively charged; use low-salt binding (e.g., 20–50 mM Tris, pH 7.5–8.5), elute with 0.3–1 M NaCl or pH shift.
    • Cation exchangers (carboxyl/sulfonate): bind at pH below target pI; use acetate/phosphate buffers, elute with salt or base.
  • Nucleic acid SPRI-like binding: 15–25% PEG 8000 with 0.7–1.2 M NaCl (or 1–5 M guanidinium for silica-like surfaces) promotes binding; wash with 70–80% ethanol; elute in low-salt TE or water.
  • Affinity (e.g., Ni–NTA): bind in phosphate or Tris with 300 mM NaCl; wash with 10–30 mM imidazole; elute with 200–300 mM imidazole or pH shift.

Practical tips:

  • Pre-wet and equilibrate beads with working buffer to stabilize performance.
  • Avoid chelators (EDTA, citrate) with metal-affinity systems; avoid high-organic fractions if coating is not solvent-tolerant.
  • Optimize pH/ionic strength to balance capacity and selectivity; verify recovery and purity in small-scale screens before scaling.
Green Alternatives

Item-specific sustainability notes: Not specified for this item; refer to CoA/Spec Sheet.

General sustainability perspective:

  • Magnetic adsorbents can reduce solvent and consumable usage by replacing filtration media, centrifugation, and multiple wash cycles with rapid magnetic decantation, lowering energy and time footprints.
  • Reusability: many coated adsorbents are regenerable through mild washing or pH/salt cycling, reducing material demand and waste generation compared to single-use sorbents.
  • Process intensification: faster cycles and smaller equipment can decrease process mass intensity (PMI) and increase space–time yields.

Comparison (general):

  • Versus activated carbon: magnetic adsorbents typically enable faster separations and straightforward retrieval without filtration; however, AC may offer higher capacity for broad-spectrum organics and lower material cost.
  • Versus ion-exchange resins (non-magnetic): magnetic formats simplify phase separation but may have lower bed utilization in batch; column resins excel in continuous operation.
  • Versus centrifugation/filtration: magnetic capture avoids filter aids and clogged membranes, with less operator exposure to aerosols.

Trade-offs:

  • Coating synthesis and metal-oxide cores carry embedded energy/footprint; select regenerable systems and benign ligands/coatings when possible.
  • Iron leaching/ligand shedding must be controlled; validate low extractables to protect downstream processes and minimize environmental release.
Pharmaceutical Uses

Item-specific pharmacopeial status/excipient role: Not specified for this item; refer to CoA/Spec Sheet. Not for human or veterinary use; for research use only (per product data).

General roles in pharmaceutical R&D and manufacturing (non-clinical):

  • Process development aids: magnetic scavengers for removal of residual transition metals (e.g., Pd, Pt, Ni) from API intermediates; removal of colored impurities or unreacted reagents from reaction mixtures.
  • Analytical sample prep: cleanup prior to LC/GC/ICP analysis (e.g., matrix de-salting, protein precipitation followed by magnetic clarification, or solid-phase extraction analogs).
  • Bioprocess research: rapid screening of binding/elution conditions for proteins or oligonucleotides without columns; small-scale clarification of cell culture supernatants.
  • Catalyst handling: magnetic catalyst supports allow quick separation, reducing risk of catalyst carryover in downstream steps.

Considerations:

  • Extractables/leachables and particulate control are critical; verify by orthogonal analytics (TOC, ICP-MS, LC-UV) prior to deployment in GMP environments.
  • Regeneration/cleaning validation should demonstrate consistent performance and low cross-contamination.
  • For any use impacting regulated processes, specific product documentation and risk assessments are required.
Physical Properties

Item-specific: Not specified for this item; refer to CoA/Spec Sheet for particle size, size distribution, saturation magnetization (Ms), surface area (BET), pore size, functional group loading, form (dry vs suspension), and moisture content.

General/literature values (qualitative):

  • Appearance: often black to dark brown (iron-oxide–based) powders or aqueous dispersions; polymer/silica coatings can lighten color.
  • Magnetic behavior: many nano-formulations are superparamagnetic (no remanence, rapid magnetization/demagnetization) facilitating redispersion after magnetic capture.
  • Density: bulk iron oxides are dense (>4 g/cm³), but effective bulk density of formulated adsorbents varies widely with coatings and porosity.
  • Porosity/surface area: shell design (mesoporous silica, polymer brushes) controls access to binding sites; BET surface areas can range from tens to hundreds of m²/g (literature), but are highly product-specific.
  • Solvent compatibility: water-compatible systems are common; some are engineered for polar organics or mixed solvents. Stability depends on coating chemistry (silica generally tolerates aqueous buffers across moderate pH; bare Fe3O4 is acid/base sensitive).
  • Thermal/chemical stability: iron oxides are thermally robust, but organic coatings/ligands define practical operating windows (typically ambient to 60–80 °C in aqueous media, literature). Always verify per item specifications before use.
Quality and Grades

Item-specific grade/purity: Not specified for this item; refer to CoA/Spec Sheet.

How quality is typically defined for magnetic adsorbents (general guidance):

  • Functional performance metrics: adsorption capacity (e.g., mg target per g adsorbent), distribution coefficient (Kd), kinetics, and selectivity in specified media.
  • Physical metrics: particle size and polydispersity, magnetic saturation (Ms), coercivity (ideally low for superparamagnetic beads), BET surface area, and pore size distribution for mesoporous systems.
  • Chemical metrics: surface functional group loading (mmol/g), leachables (iron, ligands, monomers), and residual solvent content.
  • Cleanliness for analytical workflows: low metal/background extractables for trace analysis; absence of UV-absorbing contaminants for chromatographic cleanups.
  • Lot-to-lot control: consistent coating thickness, ligand density, and magnetization ensure reproducible capture and release profiles.

Implications of stabilization/coatings (general):

  • Silica-coated cores typically offer broader pH tolerance and lower iron leaching compared with bare Fe3O4.
  • Polymer or polydopamine coatings provide versatile post-functionalization but may introduce organic extractables if not fully cured.

Documentation: For this item, consult the Aladdin CoA/Spec Sheet for the validated test panel, recommended operating ranges, and any preconditioning required prior to first use.

Reaction and Applications

Item-specific intended applications: Not specified for this item; refer to catalog notes and CoA/Spec Sheet.

General/literature applications for magnetic adsorbents:

  • Rapid separations: bind–wash–elute workflows using a handheld magnet for pollutant removal (dyes, phenols), metal scavenging (e.g., Pd, Ni, Cu after cross-couplings), or cleanup of reaction mixtures.
  • Heterogeneous catalysis: magnetic cores support catalytic nanoparticles or organocatalysts, enabling facile catalyst recovery and reuse.
  • Biochemical capture (when appropriately functionalized): affinity purification (e.g., His-tag via Ni–NTA, boronate for glycoproteins), nucleic acid isolation (SPRI-like), or cell capture via antibody/lectin coatings. For this product, confirm surface chemistry before use.
  • Process intensification: replace filtration with magnetic decantation, minimizing fouling and enabling viscous or particulate-laden streams to be processed.

Practical tips:

  • Pre-equilibrate adsorbent in the working medium to condition the surface and remove fines; discard the pre-wash if background contaminants matter.
  • Dose selection: start with 5–50 mg adsorbent per mL of solution (literature heuristic) and titrate to capacity; monitor breakthrough by UV–vis, ICP, or HPLC depending on analyte.
  • Contact time: many systems approach equilibrium within minutes under good mixing; confirm kinetics for your matrix.
  • Magnet handling: approach the vessel side slowly to avoid compacting/entrapping fines; allow a clear supernatant before decanting; resuspend with vortex/sonication as permitted by coating.
Reaction Conditions

Item-specific operating ranges: Not specified for this item; refer to CoA/Spec Sheet for recommended pH, temperature, solvent compatibility, and regeneration protocols.

General/literature guidance for adsorption-based workflows:

  • Temperature: many adsorption processes are effective at ambient temperature (20–25 °C); modest warming (30–50 °C) can accelerate kinetics if coatings are stable.
  • pH: governs ionization states; map adsorption vs pH to locate maxima/minima. Iron oxides exhibit point of zero charge (PZC) in the ~6–8 range (literature); coatings shift behavior substantially.
  • Ionic strength: salt screens electrostatics; low salt for binding on ion-exchange surfaces, high salt for elution or to suppress nonspecific interactions.
  • Contact time and mixing: end-over-end or orbital mixing for 5–30 min is a common starting point; verify equilibrium by time-course sampling.
  • Dose: begin with 5–50 mg/mL (adsorbent/solution) and optimize based on capacity and matrix effects.
  • Regeneration: use pH swings, salt, or mild solvents to desorb; avoid harsh conditions that strip coatings or dissolve cores unless specified.

Analytical monitoring:

  • Use UV–vis/HPLC/GC/ICP as appropriate to quantify adsorption and elution; construct isotherms (Langmuir/Freundlich) for process design.

Note: Always verify compatibility with your analyte and solvent system before scaling.

Safety and Handling

Item-specific GHS/Signal word/H-statements/pictograms: Not specified for this item; refer to the product SDS for authoritative safety information.

General guidance for magnetic adsorbents (literature/best practice):

  • Potential hazards: fine powders may create nuisance dust; nanoparticles present inhalation risks—minimize airborne release. Some functional groups (e.g., quaternary ammonium, chelators) and residual monomers/solvents may cause irritation.
  • PPE: wear lab coat, safety glasses, and appropriate gloves (nitrile commonly suitable). Use a fume hood or ventilated enclosure when handling dry powders or during sonication that may aerosolize droplets.
  • Incompatibilities: strong acids or bases can dissolve/etch iron oxide cores or degrade silica/polymer shells. Strong oxidants/reductants may alter surface chemistry or core oxidation state. Avoid halogenating agents unless compatibility is documented.
  • Handling tips: prevent magnetic compaction against vessel walls by controlling magnet strength and approach speed; use low-retentive pipette tips for suspensions. Sonicate gently to redisperse if compatible with coating.
  • First aid (overview; defer to SDS): move to fresh air if inhaled dust; rinse skin/eyes with water for several minutes if contacted; seek medical attention if irritation persists.
  • Disposal: treat as laboratory chemical waste; adsorbed contaminants (e.g., metals, dyes) can change waste classification—segregate accordingly and follow institutional/EHS guidance.
Solvent Selection

Item-specific solvent compatibility: Not specified for this item; refer to CoA/Spec Sheet.

General selection principles for magnetic adsorbents:

  • Match medium to surface chemistry: ion-exchange surfaces operate in aqueous buffers with controlled ionic strength and pH; hydrophobic/π–π surfaces may prefer aqueous-organic mixtures (e.g., water/MeOH, water/ACN) to tune selectivity.
  • pH and ionic strength strongly modulate adsorption for charged targets; screen buffers such as acetate (pH 4–5.5), phosphate (pH 6–8), or Tris/HEPES (pH 7–8.5). Avoid buffers that coordinate strongly if using metal-chelating ligands (e.g., EDTA can strip metals).
  • Organic tolerance: silica shells often tolerate up to moderate fractions of water-miscible solvents; polymeric coatings vary widely—verify alcohols, ketones, or chlorinated solvents case-by-case.
  • Viscosity and mass transfer: lower viscosity media (warm, diluted organics) can improve kinetics; gentle agitation or end-over-end mixing reduces boundary-layer limitations.

When to choose water-only vs mixed solvents:

  • Water-only buffers: highest biocompatibility and simplest waste; ideal for biomolecule capture when solubility allows.
  • Aqueous-organic blends: useful to disrupt nonspecific binding or recover hydrophobic analytes; ensure coating stability first.

Comparison (general):

  • Magnetic adsorbent vs traditional resins: faster separations without filtration/centrifugation; easier scale-down/up; sometimes lower capacity than fully porous chromatographic media.
Storage and Reconstitution

Item-specific storage: Room temperature (per Product Data). Shipped under normal conditions.

Additional item-specific details (formulation, preservatives, shelf life): Not specified for this item; refer to CoA/Spec Sheet and product label.

General guidance:

  • If supplied as a dry powder: store tightly closed in a clean, dry container at ambient temperature; protect from excessive humidity and corrosive atmospheres. Keep away from strong magnets to prevent compaction against container walls.
  • If supplied as an aqueous suspension: store at recommended temperature (often RT or 2–8 °C depending on preservative/coating—verify on label). Gently resuspend by inversion or vortexing before use; avoid freeze–thaw unless explicitly allowed, as freezing can fracture beads or destabilize coatings.
  • Reconstitution (for dry formats): wet with compatible solvent/buffer, then sonicate briefly or vortex to disperse; pre-equilibrate by washing with working buffer. Degas buffers if bubble entrapment affects handling.
  • Stability: avoid prolonged exposure to strong acids/bases or oxidants; minimize microbial contamination by using sterile technique for bio-oriented work or adding appropriate preservatives if compatible with application.

Always consult the SDS and CoA/Spec Sheet for definitive handling and storage instructions specific to this SKU.

Structure and Identity

Item-specific: Not specified for this item; refer to CoA/Spec Sheet for composition, functional groups, and particle architecture.

General/literature context:

  • Magnetic adsorbents are typically composite materials built around a magnetic core (commonly magnetite Fe3O4 or maghemite γ-Fe2O3) coated with an inorganic (e.g., SiO2) or polymeric shell that presents adsorption sites (e.g., –OH, –NH2, –COOH, quaternary ammonium, imidazole, thiol, or tailored ligands/chelators).
  • Structural features usually include:
    • A magnetic core enabling rapid capture with an external magnet (superparamagnetic behavior is common at nanoscale to minimize remanence/agglomeration).
    • A stabilizing/interfacial layer (silica, dextran, PEG, polystyrene, polyacrylate, polydopamine) that confers colloidal stability and protects the core.
    • Surface functional groups providing selectivity via ion exchange, chelation, hydrophobic or π–π interactions, hydrogen bonding, or affinity ligands (e.g., Ni–NTA for His-tags; boronate for cis-diols).
  • 2D description (generic): a spherical or irregular core (iron oxide) encapsulated by a thin shell, with outward-facing functional moieties distributed across the surface. Particles may be nano- (10–200 nm) or micro-scale (1–50 μm) depending on application.
  • Molecular formula, SMILES, InChIKey: Not applicable to undefined composite materials (literature: such materials are mixtures/solids rather than discrete molecules).
Synthetic Utility

Item-specific reactivity: Not specified for this item; refer to CoA/Spec Sheet.

General synthetic roles of magnetic adsorbents:

  • Scavenging: remove metal catalysts (e.g., Pd from Suzuki/Heck, Cu from click reactions) using thiol/amine/iminodiacetate-functionalized surfaces; quantify residuals by ICP-MS.
  • Quench and cleanup: capture electrophiles (acid chlorides, isocyanates) or nucleophiles (amines) using complementary functionalized beads to simplify workups.
  • Phase-switchable workups: bind product or impurity selectively, decant mother liquor, wash, and elute under mild conditions (pH/salt/solvent change).
  • Catalyst supports: immobilize organometallic or organocatalytic species on magnetic cores for easy recovery and reuse with minimal filtration.
  • Solid-phase transformations: enable on-bead derivatization, then magnetic separation to remove reagents/byproducts, akin to solid-phase synthesis but without packed beds.

Strategic advantages:

  • Rapid, filtration-free separations reduce mechanical losses and exposure to air/moisture for sensitive systems.
  • Easy parallelization in multi-well formats for route scouting.

Tips:

  • Titrate bead loading to minimize co-adsorption of product; verify selectivity via small-scale experiments.
  • Validate elution conditions that preserve product integrity; avoid strong oxidants/reductants that may affect the iron-oxide core or ligands.
Target Specificity

Item-specific target/epitope/clone/isotype: Not applicable. This product is a magnetic adsorbent, not a biological antibody or targeted biochemical with defined antigen specificity.

General note:

  • If the adsorbent is functionalized with affinity ligands (e.g., Ni–NTA, streptavidin, antibodies), the target specificity depends entirely on that ligand chemistry and its density/orientation on the surface. For this item, such details are Not specified; refer to the CoA/Spec Sheet for any affinity features.

Deseja que lhe enviemos uma mensagem quando tivermos descontos disponíveis?

Lembrar-me mais tarde

Obrigado! Por favor, verifique a sua caixa de entrada de e-mail para confirmar.

Ops! As notificações estão desativadas.