Permethrin solution - analytical standard, 100μg/ml in petroleum ether , CAS No.52645-53-1

CAS: 52645-53-1 Cat. No.: P111931 Fórmula: C21H20Cl2O3 Peso molecular: 391.29 Beilstein Registry Number: 5765325 Número CE: 258-067-9
Disponível para encomenda
GRAU & PUREZA Analytical standard ? Analytical standard — certified-purity material for quantitative calibration. Use to prepare calibration standards and validate analytical methods. 100μg/ml in petroleum ether
Storage
Protected from light,Store at -20°C
Shipped In
Ice chest + Ice pads
★
Tamanho
Alemanha (EU)
USA*
Preço
Qtd
1ml
P111931-1ml
—
2 Em stock

38,09€

48,51€
Gravar 10,41 € (21.47%)
Enter a quantity for the sizes you want to add.

Especificações

Especificações e pureza
analytical standard, 100μg/ml in petroleum ether
Condições de armazenamento de armazenamento
Protected from light,Store at -20°C
Enviado em
Ice chest + Ice pads
Este produto requer transporte de cadeia fria. Serviços terrestres e outros serviços econômicos não estão disponíveis.
Grau
Analytical standard
Nomes e identificadores
SMILES isoméricas
CC1(C(C1C(=O)OCC2=CC(=CC=C2)OC3=CC=CC=C3)C=C(Cl)Cl)C
WGK Alemanha
3
RTECS
GZ1255000
Número UN
3077
Grupo de embalagem
III
Peso molecular
391.29
Beilstein
5765325
Reaxys
5765325
Reaxys-RN_link_address
https://www.reaxys.com/reaxys/secured/hopinto.do?context=S&query=IDE.XRN=5765325&ln=

Dados avançados

Certificados(CoA,COO,BSE/TSE e Mapa de Análise)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate TypeDataItem
C2222456C2222456Certificate of AnalysisMar 05, 2022 P111931
Propriedades químicas e físicas
Sensibilidadelight sensitive
Índice de refração1.5627
Ponto de ebulição (°C)>290℃(760 torr)
Ponto de fusão (°C)35°C
Segurança e perigos (GHS)
Pictograma(s)
GHS02,   GHS07,   GHS08,   GHS09
Sinal
Danger
Declarações de perigo

H224:Extremely flammable liquid and vapor

H304:May be fatal if swallowed and enters airways

H315:Causes skin irritation

H340:May cause genetic defects

H350:May cause cancer

H411:Toxic to aquatic life with long lasting effects

H335+H336:May cause respiratory irritation,May cause drowsiness or dizziness

Declarações de precaução

P301+P310:IF SWALLOWED: Immediately call a POISON CENTER/doctor/...

P304+P340:IF INHALED: Remove person to fresh air and keep comfortable for breathing.

P305+P351+P338:IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do - continue rinsing.

P308+P313:IF exposed or concerned: Get medical advice/attention.

P332+P313:IF SKIN irritation occurs: Get medical advice/attention.

P370+P378:In case of fire: Use ... to extinguish.

P403+P233:Store in a well-ventilated place. Keep container tightly closed.

P403+P235:Store in a well-ventilated place. Keep cool.

WGK Alemanha
3
RTECS
GZ1255000
Reaxys
5765325
Reaxys-RN_link_address
https://www.reaxys.com/reaxys/secured/hopinto.do?context=S&query=IDE.XRN=5765325&ln=
Classe
9
Citations of This Product
Calculadoras de soluções
Revisões

Avaliações dos Clientes

Application Protocols

No item-specific, validated application protocols are provided for this product. The following are general laboratory practices for using small-molecule pesticide analytical standards (literature/general):

  • Stock handling:

    • On receipt, inspect vial integrity and allow to equilibrate to room temperature before opening to prevent condensation. Protect from light.
    • Record lot number and any concentration/solvent details from the CoA.
  • Working standards:

    • Prepare serial dilutions gravimetrically when possible to minimize volumetric error, using solvent compatible with your analytical method (e.g., hexane/isooctane for GC, acetonitrile/methanol for LC).
    • Use amber vials, PTFE-lined caps; rinse pipette tips/syringes with the diluent to minimize adsorption.
  • Calibration:

    • Prepare multi-level calibration (e.g., 6–10 points) across the expected range. Include at least one independent check standard.
    • For isomer-resolving methods, report calibration as total permethrin or per-isomer; be consistent across samples and standards.
  • Matrix spikes:

    • Spike known volumes into blank matrices at representative levels; allow solvent to evaporate or equilibrate before extraction to mimic real samples.
  • Quality control:

    • Include procedural blanks, solvent blanks, and matrix duplicates. Monitor continuing calibration verification (CCV) every 10–15 injections.

Always defer to your internal SOPs and regulatory guidance (e.g., SANTE/FDA/EPA) as applicable.

Biological Roles

This section summarizes the biological mode-of-action of permethrin as a chemical entity for context in environmental and biochemical studies. It does not imply any clinical or therapeutic use.

  • Mode of action (literature):

    • Pyrethroid insecticide that targets voltage-gated sodium channels (Nav) in nerve membranes, prolonging channel opening and causing repetitive firing in insects. Stereochemistry can influence potency and binding kinetics.
  • Selectivity (literature):

    • Greater potency in arthropods due to differences in sodium channel isoforms and metabolic detoxification pathways. Mammalian sodium channels exhibit lower sensitivity, and biotransformation (e.g., esterases, cytochrome P450s) tends to reduce systemic persistence compared to insects.
  • Metabolism and degradation (literature):

    • Hydrolysis of the ester to 3-phenoxybenzoic acid (3-PBA) and 3-phenoxybenzyl alcohol; oxidative pathways yield conjugates excretable in urine in mammals. In the environment, photolysis and biodegradation occur, with strong sorption to soils/sediments driven by high hydrophobicity (logKow >6).
  • Biomonitoring markers (literature):

    • 3-PBA is a common metabolite measured in exposure studies; method development often employs analytical standards for both parent permethrin and metabolites.
  • Laboratory relevance:

    • Understanding the biochemical targets helps in designing selective extraction/cleanup and choosing detection schemes (e.g., MS/MS transitions targeting characteristic fragments of the phenoxybenzyl moiety).

Note: No medical or veterinary claims are made; this product is for research use only.

Buffer Applications

Not typically applicable. Permethrin is a highly hydrophobic neutral organic compound and is not used to prepare aqueous buffers or biological buffer systems. For analytical work, focus on organic solvent systems and chromatographic methods described in Solvent Selection, Reaction & Applications, and Reaction Conditions.

Green Alternatives

While the analyte (permethrin) itself is not a "green" chemical, you can improve the sustainability of analytical workflows by careful solvent and method selection. The product’s exact solvent is Not specified for this item; refer to CoA/Spec Sheet. The guidance below reflects general greener-practice considerations (literature/general).

  • Solvent considerations for standards and dilutions:

    • Prefer acetonitrile or ethanol over chlorinated solvents when LC methods are viable.
    • For GC workflows, isooctane can substitute for hexane in some labs due to lower neurotoxicity concerns, though both are volatile organic compounds.
    • Ethyl acetate can be a compromise diluent for some extractions and LC injections; assess compatibility with your method.
  • Miniaturization and waste reduction:

    • Adopt microvials and low-volume inserts to reduce solvent consumption in calibration.
    • Use multi-analyte mix standards to consolidate runs when validation permits.
  • Energy and materials:

    • Store at recommended low temperature efficiently (shared cold storage, insulated secondary containment). Use amber glass to reduce light-driven degradation without excessive secondary packaging.
  • Trade-offs (example comparison):

    • Hexane: Excellent GC solvent; higher VOC emissions, lower flash point.
    • Isooctane: Similar GC compatibility; slightly better toxicological profile; still a VOC.
    • Acetonitrile: LC-friendly, recyclable by distillation; nitrile waste handling required.
    • Ethanol/Ethyl acetate: Renewable feedstock potential; check analyte stability and detector baseline.

Always verify recovery, stability, and detector compatibility when changing solvents.

Pharmaceutical Uses

Not applicable to this product listing. This is an analytical standard for laboratory research use only and is not an excipient, API, or formulation aid in pharmaceutical manufacturing. No pharmacopeial monograph or compendial status is claimed for this item. For any regulatory applications, users must source appropriate certified reference materials and follow applicable pharmacopeial standards.

Physical Properties

Item-specific properties (solution standard):

  • Solvent, concentration, and appearance: Not specified for this item; refer to CoA/Spec Sheet.

Compound-level literature values for permethrin (parent analyte; provided for context only):

  • Physical state: Viscous liquid/low-melting solid depending on isomeric composition (literature).
  • Melting point: Reported ranges ~34–39 °C for technical mixtures (literature).
  • Boiling point: Decomposes; reported >200 °C at reduced pressure (literature).
  • Density: Approx. 1.19 g/mL at 20–25 °C (literature, mixture-dependent).
  • Water solubility: Very low, typically 5–10 µg/L at 20–25 °C (literature).
  • Organic solvent solubility: Miscible or highly soluble in nonpolar and moderately polar organics (hexane, toluene, acetone, dichloromethane, ethyl acetate, acetonitrile; literature).
  • logKow (octanol/water): ~6.1–6.5 (highly hydrophobic; literature).
  • pKa: Neutral molecule; no ionizable centers in the environmental pH range (literature).
  • Refractive index: nD ~1.56–1.58 (literature, mixture-dependent).

Analytical implications (general):

  • Strong hydrophobicity and aromatic chromophores give good GC-ECD response and LC-UV response (near 226–230 nm) with optimal sensitivity often achieved by MS or ECD detection (literature).
  • Low aqueous solubility favors extraction into nonpolar solvents; strong retention on C18 and phenyl stationary phases with high organic mobile phase compositions (literature).

Note: None of the physical values above are item specifications. For the exact properties of this solution standard (e.g., concentration, solvent), consult the product CoA/Spec Sheet.

Quality and Grades
  • Item-specific grade: Analytical standard.

    • Meaning: Prepared and qualified for use as a reference material in quantitative and qualitative analytical workflows (e.g., calibration curves, system suitability, spike-recovery, proficiency testing). Typically supplied with documentation such as an assay value, uncertainty, lot-specific chromatographic purity, and traceability. The exact attributes for this product are Not specified for this item; refer to CoA/Spec Sheet.
  • Purity and composition: For solution standards, the key quality attributes are the identity and purity of the parent analyte and the accuracy/traceability of the assigned concentration in a defined solvent. Concentration, solvent system, stabilizers (if any), and isomeric composition are Not specified for this item; refer to CoA/Spec Sheet.

  • Practical implications for permethrin:

    • Isomer composition matters: Analytical methods may resolve cis/trans isomers. Your calibration should match the isomer profile of the target or report total permethrin accordingly.
    • Matrix compatibility: Choose diluents compatible with your chromatographic method (e.g., hexane for GC-ECD, acetonitrile or MeOH for LC-MS/MS) to avoid peak distortion.
    • Documentation: Expect batch-specific CoA indicating target concentration, uncertainty, and recommended storage. Always retain the CoA in your data package to support traceability and compliance.
  • Comparison to other grades:

    • Technical-grade pesticide is unsuitable for calibration due to unknown impurities and isomer ratios.
    • Analytical standards are controlled and intended for instrument calibration and method validation.
Reaction and Applications

As sold, this product is an analytical standard solution intended for calibration and method validation. Reaction chemistry is not the primary use. Relevant applications (literature/general analytical practice) include:

  • Instrument calibration and system suitability:

    • GC-ECD/GC-MS quantitation of pyrethroid residues in food, environmental water, soil, and surface wipes.
    • LC-UV/LC-MS/MS confirmation where thermal lability or matrix coelution complicates GC workflows.
  • Method validation:

    • Spike-and-recovery experiments, linearity (multi-level calibration), LOD/LOQ determination, precision and accuracy studies, and matrix effects assessment using matrix-matched standards.
  • Sample preparation development:

    • Optimization of extraction and cleanup protocols (e.g., QuEChERS for food, SPE on C18/PS-DVB/Florisil for water and soil) by spiking known amounts of permethrin standard.
  • Stability/partitioning studies:

    • Evaluate photolysis, hydrolysis, and adsorption to organic matter; determine Kd and Koc using the standard as a tracer in controlled systems.
  • Practical tips:

    • Use calibrated glassware or gravimetric dilutions to prepare working standards. Minimize adsorption losses by conditioning vials with the solvent and avoiding plastics that can absorb hydrophobic analytes.
    • Match isomeric profile: If your method resolves cis/trans, document whether calibration is total response or isomer-specific.
    • Protect solutions from light, use amber vials, and store cold to maintain integrity.
Reaction Conditions

For this analytical standard, "reaction" conditions translate to typical analytical conditions used to measure permethrin. The exact solvent and concentration of the supplied solution are Not specified for this item; refer to CoA/Spec Sheet. Below are literature/general method parameters to guide method development:

  • GC-ECD/GC-MS (literature, typical):

    • Column: 30 m × 0.25 mm × 0.25 µm 5% phenyl/95% dimethylpolysiloxane.
    • Oven: Start 80–100 °C (hold 1–2 min), ramp 10–20 °C/min to 280–300 °C (hold 5–10 min).
    • Injector: Splitless 200–250 °C; use solvent-appropriate liner to reduce breakdown.
    • Carrier: He or H2 at 1–2 mL/min.
    • Notes: Permethrin is GC-compatible; monitor for potential on-column isomerization with overly hot inlets.
  • LC-UV/LC-MS/MS (literature, typical):

    • Column: C18 or phenyl-hexyl, 100–150 mm × 2.1–4.6 mm, 3–5 µm.
    • Mobile phase: High-organic eluent (e.g., 70–95% acetonitrile or methanol) with water; small acid or ammonium buffer (0.1% formic acid/5 mM ammonium formate) can aid MS response.
    • Detection: UV 226–230 nm; MS/MS transitions targeting phenoxybenzyl fragments.
    • Flow: 0.2–1.0 mL/min; column temp 30–40 °C.
  • Sample preparation (literature):

    • Food QuEChERS: ACN extraction, salt-out, PSA/C18 cleanup.
    • Water/soil: LLE with hexane/MTBE or SPE (C18/HLB), elute with nonpolar solvents.
  • Expected performance:

    • Linearity typically spans low µg/L to mg/L in solvent; matrix LOQs often in low µg/kg (food) or ng/L–µg/L (water) with MS/MS.

These are general guidelines, not item specifications.

Safety and Handling

Item-specific hazard fields (from Product Data):

  • Signal word, H-statements, GHS classification, pictograms: Not specified for this item; refer to SDS.

General safety information for permethrin compounds and solution standards (literature; consult the SDS for authoritative guidance):

  • Likely GHS hazards for permethrin (parent): Hazardous to the aquatic environment, acute and chronic Category 1; may be harmful if swallowed; skin sensitizer (literature classifications vary by formulation). The specific classification of this item depends on its solvent and concentration.
  • Primary risks: Pyrethroids are neurotoxicants to insects; avoid inhalation, ingestion, and skin contact. Solutions may include flammable solvents (e.g., hexane, acetonitrile, methanol); check label and SDS.
  • PPE: Laboratory coat, safety glasses or splash goggles, and appropriate chemically resistant gloves (e.g., nitrile). Use in a chemical fume hood to control vapors/aerosols.
  • Handling: Prevent environmental release. Avoid sources of ignition if the solvent is flammable. Use secondary containment when transporting working aliquots.
  • Incompatibilities: Strong oxidizers; avoid prolonged exposure to strong bases or acids that may hydrolyze the ester (general chemistry). Do not mix with oxidants or halogenating agents. Store away from food/feed.
  • First aid (general): If on skin, wash with soap and water; remove contaminated clothing. If in eyes, rinse cautiously with water for several minutes. If inhaled, move to fresh air. If swallowed, rinse mouth; do not induce vomiting—seek medical advice. Always follow the SDS for this specific item.
  • Environmental: Extremely toxic to aquatic organisms; collect spills to prevent drain release. Dispose according to local regulations.
Solvent Selection

This item is supplied as a solution standard; the exact solvent is Not specified for this item; refer to CoA/Spec Sheet. The guidance below concerns solvent choice for handling/diluting permethrin standards in typical analytical methods (literature/general practice).

  • Polarity and miscibility (compound-level behavior):

    • Highly hydrophobic (logKow ~6.1–6.5, literature); negligible water solubility.
    • Readily soluble in nonpolar and moderately polar organic solvents (hexane, isooctane, toluene, dichloromethane, ethyl acetate, acetone, acetonitrile, methanol; literature). Avoid high-water-content media.
  • Method-driven selection:

    • GC-ECD/GC-MS: Hexane or isooctane are common for stock and calibration solutions; toluene can improve stability for some pyrethroids. Keep final solvent compatible with autosampler vials/seals.
    • LC-UV/LC-MS/MS: Acetonitrile or methanol stocks; dilute into high-organic mobile phase (e.g., 60–95% organic) to minimize peak distortion. For ESI, acetonitrile often affords better desolvation and less adducting than methanol.
  • Stability considerations:

    • Ester hydrolysis is base/acid catalyzed; avoid prolonged exposure to strong bases or acids in solution. Maintain dry solvents where possible.
    • Light sensitivity: Protect from light (amber vials, foil). Lower temperatures slow degradation.
  • Small comparison (general):

    • Hexane/isooctane: Ideal for GC, nonpolar extractions; flammable, low polarity.
    • Acetonitrile: LC-friendly, lower viscosity; polar aprotic, miscible with water; may require high organic content to prevent precipitation.
    • Toluene: Good solvency and stability for hydrophobes; higher boiling, stronger odor.
Storage and Reconstitution

Item-specific storage and logistics:

  • Storage conditions: Protected from light, Store at -20 °C (per Product Data).
  • Shipped in: Ice chest + ice pads (per Product Data) to maintain low temperature and protect from thermal and photolytic degradation.

Handling and reconstitution (general guidance for solution analytical standards):

  • Concentration/solvent: Not specified for this item; refer to CoA/Spec Sheet for exact composition.
  • Upon arrival: Keep sealed in original amber vial. Allow to warm gradually to room temperature before opening to avoid condensation. Mix gently (do not vortex if the solvent is volatile) to re-homogenize.
  • Aliquoting: If frequent use is expected, subdivide into small amber vials under low-light conditions to minimize freeze–thaw cycles and headspace oxygen. Use gas-tight syringes for volatile solvents.
  • Light protection: Store in amber glass and/or wrap with aluminum foil to minimize photolysis.
  • Freeze–thaw: Minimize cycles. If the solvent’s freezing point is above -20 °C, allow complete thaw and mix before use.
  • Stability: Solution stability is matrix- and temperature-dependent; verify by periodic check standards and compare against initial response. Discard if precipitation, phase separation, or significant response drift is observed.
  • Disposal: Treat as hazardous chemical waste; avoid release to drains. Follow institutional and local regulations.

For any item-specific details such as shelf life, assigned concentration, and uncertainty, consult the lot-specific CoA/Spec Sheet.

Structure and Identity

Permethrin is a synthetic pyrethroid ester; this catalog item is supplied as a solution analytical standard for research and analytical use.

  • Item-specific identifiers

    • SKU: P111931
    • CAS: 52645-53-1 (permethrin)
    • Product form: Solution analytical standard — solvent/concentration: Not specified for this item; refer to CoA/Spec Sheet.
  • Literature identifiers (for compound identity; not item-specific specs)

    • Common name: Permethrin (mixture of cis/trans isomers)
    • IUPAC (one descriptor of racemic mixture): 3-phenoxybenzyl (1R,3R)-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylate (stereochemistry varies by isomer)
    • Molecular formula (literature): C21H20Cl2O3
    • Molecular weight (literature): ~391.29 g/mol
    • PubChem CID: 40326
    • InChIKey (literature, parent permethrin): RLLPVAHGXHCWKD-UHFFFAOYSA-N
    • SMILES (literature, one non-stereospecific form): ClC(=CCl)C1C(C1(C)C)C(=O)OCC2=CC(=CC=C2)OC3=CC=CC=C3
  • Structural features (general chemistry)

    • Functional groups: Aromatic ether (phenoxy), benzylic alcohol-derived benzyl ester, dichlorovinyl moiety, cyclopropane carboxylate, two gem-dimethyl substituents.
    • Stereochemistry: Two stereocenters on the cyclopropane ring; commercial/analytical materials are commonly mixtures of cis/trans isomers (e.g., ~25:75, literature). No specific isomer ratio is stated for this item; refer to CoA/Spec Sheet.
    • 2D description: A 3-phenoxybenzyl group is esterified to a substituted cyclopropanecarboxylate; a dichloroethenyl substituent resides at the cyclopropane 3-position, and gem-dimethyls at the 2-position.
Synthetic Utility

As supplied, this product is intended as an analytical standard rather than a synthetic building block. For completeness, the following outlines the compound-level synthetic context of permethrin (literature, not a procedure for this item):

  • Retrosynthetic analysis (general):

    • Permethrin is the benzyl ester derived from 3-phenoxybenzyl alcohol and chrysanthemic acid [3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid].
  • Key transformations:

    • Construction of the cyclopropane core (chrysanthemic acid) typically via cyclopropanation methodologies or via rearrangement from suitable precursors; introduction of the 2,2-dichlorovinyl group by halogenation/elimination sequences.
    • Esterification of chrysanthemic acid with 3-phenoxybenzyl alcohol under dehydrative coupling (acid chloride, DCC/DMAP, or carbodiimide-based protocols) to give the benzyl ester.
  • Stereochemical considerations:

    • Two stereocenters on the cyclopropane yield cis/trans isomers; commercial materials are mixtures. Enantio- and diastereoselective routes exist to individual isomers with potentially different biological activities.
  • Analytical implications in synthesis:

    • NMR, GC/LC, and chiral/diast. chromatographies are used to determine isomer ratios and purity. GC-ECD and LC-MS/MS are especially sensitive for trace-level determination.

This information is provided for chemical context only; the current catalog item is not positioned for synthetic use.

Target Specificity

Not applicable. This product is a small-molecule analytical standard and not a biological targeting reagent (e.g., antibody, inhibitor with defined selectivity panel supplied). For biological mode-of-action context, see Biological Roles.

Perguntas frequentes

What does analytical standard mean?
analytical standard is a defined analytical purity tier suitable for quantitative analytical methods. It specifies a minimum assay percentage, controlled limits on common impurities (water, heavy metals, residue on ignition), and lot-to-lot consistency. analytical standard is one of several purity tiers — choose based on the sensitivity and regulatory requirements of your method.
How should this product be stored?
Store at ?20 °C, protected from light. The material is light-sensitive — keep it in its original opaque or amber container.
How is this product shipped?
This product ships in an insulated container with ice pads. Unpack on arrival and transfer it to the storage condition stated above.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 52645-53-1, the molecular formula is C21H20Cl2O3, and the molecular weight is 391.29 g/mol.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Deseja que lhe enviemos uma mensagem quando tivermos descontos disponíveis?

Lembrar-me mais tarde

Obrigado! Por favor, verifique a sua caixa de entrada de e-mail para confirmar.

Ops! As notificações estão desativadas.