Sodium lactate ringer's solution

Cat. No.: S1445703
Disponível para encomenda
Storage
Store at -20°C
Shipped In
Ice chest + Ice pads
★
Tamanho
Alemanha (EU)
USA*
Preço
Qtd
1mg
S1445703-1mg
Sob encomenda · 8–12 semanas
Enter a quantity for the sizes you want to add.

Visão geral

Sodium lactate ringer's solution is an isotonic crystalloid solution used to regulate body fluids, electrolytes and acid-base balance, and to provide fluid rehydration in the perioperative period. Sodium lactate ringer's solution consists of a sterile aqueous solution of sodium lactate, sodium chloride, potassium chloride, and calcium chloride (RL, 130 mEq sodium/L, 274 mOsm/L).

Especificações

Condições de armazenamento de armazenamento
Store at -20°C
Enviado em
Ice chest + Ice pads
Este produto requer transporte de cadeia fria. Serviços terrestres e outros serviços econômicos não estão disponíveis.

Dados avançados

Certificados(CoA,COO,BSE/TSE e Mapa de Análise)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Calculadoras de soluções
Revisões

Avaliações dos Clientes

Application Protocols

No tested applications, methods, or dilutions are specified for this item in the provided data. Refer to the CoA/Spec Sheet for any item-specific guidance.

General, non-item-specific suggestions (for context only; not validated for this product):

  • Tissue/cell rinsing: Bring to working temperature, verify sterility if required, and equilibrate CO2 if using in CO2-incubated workflows. Avoid mixing with phosphate-rich buffers to prevent Ca2+ precipitation.
  • Buffer exchange: Use centrifugal filters or dialysis with appropriate MWCO; confirm compatibility of Ca2+/K+ with your sample.

Because no validated protocols are provided, users should establish conditions empirically and consult the SDS and CoA.

Biological Roles

Note: The following are general biological roles of components commonly present in lactated Ringer-type solutions and are provided for context only. They are not item-specific specifications.

  • Lactate (literature)

    • Central metabolite in carbohydrate metabolism; interconverts with pyruvate via lactate dehydrogenase and can enter the TCA cycle after conversion to pyruvate.
    • Serves as a carbon/energy source for many cell types and contributes mild buffering in the acidic range (pKa ~3.86), though weak at physiological pH.
  • Sodium and chloride (literature)

    • Principal extracellular ions governing osmotic balance and membrane potential maintenance.
  • Potassium (literature)

    • Major intracellular cation; small extracellular K+ additions help maintain more physiologic ionic conditions in extracellular solutions used ex vivo.
  • Calcium (literature)

    • A ubiquitous second messenger; extracellular Ca2+ is essential for cell adhesion, channel function, and signaling. Presence of Ca2+ makes the solution unsuitable for applications requiring Ca2+-free environments.
  • Water matrix

    • Provides the solvent environment that preserves osmolarity and ionic strength akin to physiological settings.

For your specific application, verify the exact ion concentrations and osmolality on the product CoA, as biological responses can be sensitive to relatively small compositional changes.

Buffer Applications

This product is an electrolyte solution with limited intrinsic buffering capacity around neutral pH. It is not a dedicated buffer like phosphate or HEPES systems.

  • General guidance (literature)

    • Lactate/lactic acid pKa ~3.86: effective buffering mainly in the acidic range; at pH ~7, buffering is modest. Consequently, lactated Ringer-type solutions are better viewed as isotonic electrolyte carriers rather than robust pH buffers.
    • Typical uses include washing, perfusion, or short-term holding where ionic composition (Na+, K+, Ca2+, Cl−, lactate) is desired and strong buffering is unnecessary or provided by a CO2/HCO3− system.
  • Practical notes

    • If a stable pH near 7.2–7.6 is critical, consider HEPES, MOPS, or phosphate buffers. Avoid phosphate if calcium must be retained in solution due to precipitation risk.
    • For electrophoresis or enzyme assays, verify compatibility: chloride and calcium may interfere with certain systems; phosphate-free nature can be advantageous in calcium-sensitive preparations.
  • Item-specific details

    • Specific pH, buffering capacity, and composition are Not specified for this item; refer to CoA/Spec Sheet.
Green Alternatives

This product is an aqueous salt solution with inherently low environmental impact compared to organic solvents. “Green alternatives” are thus framed as functional substitutes with similar performance but different tradeoffs for specific workflows.

  • Environmental/operational profile (general)

    • Water-based, non-flammable, and typically low VOC. Primary impacts arise from cold-chain logistics and single-use plastics.
  • Potential substitutes (literature/general; choose based on application)

    • Phosphate-buffered saline (PBS): Widely available; stronger buffering from phosphate but incompatible with calcium-containing systems due to Ca3(PO4)2 precipitation risk.
    • Normal saline (0.9% NaCl): Simplest isotonic vehicle; lacks K+, Ca2+, and lactate—reduced risk of precipitation with phosphate but less physiologically representative electrolytes.
    • HEPES-buffered saline: Excellent buffering near neutral pH; includes organic buffer component (HEPES) that can have photochemical byproducts under intense light.
  • Comparison highlights

    • Lactated Ringer’s: includes Ca2+/K+ and metabolizable lactate; low phosphate; mild buffering.
    • PBS: strong inorganic buffering; no Ca2+/Mg2+ (typical lab PBS) to avoid precipitation; higher phosphate load.
    • Saline: minimal composition; broad compatibility but limited buffering and no divalent cations.

Select based on ion requirements, buffering needs, and compatibility with downstream assays.

Pharmaceutical Uses

This listing is for research use only. No clinical or therapeutic use is claimed or implied.

  • Formulation and process context (general)

    • In pharmaceutical R&D laboratories, lactated Ringer-type solutions are used as isotonic vehicles, rinses, or excipient-like media for in vitro studies of devices, materials compatibility, and assay development.
    • The presence of Ca2+ and K+ can better emulate extracellular ionic conditions relative to simple saline, while low phosphate reduces risk of calcium phosphate precipitation.
  • Compliance note

    • Pharmacopeial-compliant grades (e.g., USP/EP) entail specific composition, sterility, endotoxin, and particulate limits and are packaged for clinical use. Such compliance is NOT specified for this item.
  • Manufacturing considerations (general)

    • When solutions with calcium are used around equipment, monitor for scale formation with phosphate-containing cleaning agents.
    • For aseptic processes, only use solutions with documented sterility/endotoxin levels and appropriate container–closure systems; otherwise restrict to non-sterile bench applications.
  • Item-specific statement

    • Grade/purity and any pharmacopeial status: Not specified for this item; refer to CoA/Spec Sheet.
Physical Properties
  • Item-specific properties

    • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
    • Density, pH, osmolarity, conductivity: Not specified for this item; refer to CoA/Spec Sheet.
    • Refractive index, logP, pKa (mixtures): Not specified for this item; refer to CoA/Spec Sheet.
  • General/literature characteristics for lactated Ringer-type solutions (for background; not product specifications)

    • Physical state: aqueous electrolyte solution, typically colorless and clear when properly prepared.
    • Typical pH: mildly acidic to near-neutral (commonly around pH 6.2–7.5 depending on exact formulation and CO2 exposure; literature).
    • Typical osmolarity: approximately isotonic (literature values often ~270–280 mOsm/L, depending on composition).
    • Conductivity: high, reflecting ionic strength (literature).
    • Lactate acid–base: lactic acid pKa ~3.86 (literature); at physiological pH, lactate exists predominantly as the lactate anion and provides limited buffering compared with phosphate/HEPES.
    • Solubility: fully miscible with water; not compatible with many organic solvents for most biological uses; salts may precipitate in high-alcohol content.
  • Notes for users

    • Because this is a salt solution containing Ca2+, insoluble precipitates can form upon concentration, freezing, or mixing with phosphate, carbonate, oxalate, and sulfate sources (general/literature caution). Check clarity after thawing and before use.
    • Exact numerical specifications for this catalog item should be confirmed on the CoA/Spec Sheet.
Quality and Grades
  • Item-specific grade/purity

    • Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
    • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Interpreting common quality designations (general guidance)

    • Research grade: suitable for general laboratory work. Sterility, endotoxin, and bioburden limits are not implied unless explicitly stated on the CoA/Spec.
    • Cell culture/sterile grade: typically sterile-filtered and packaged to maintain sterility; low bioburden/endotoxin specifications are defined on the CoA. Not assumed for this item unless stated.
    • USP/EP/JP or injection grades: pharmacopeial compliance implies stringent composition, impurity, sterility, and particulate standards. This listing is for research use only; no pharmacopeial status is implied.
  • Stabilizers/antimicrobials

    • No stabilizers or preservatives are specified for this item. If bacteriostatic agents are present in a formulation, they must be declared; absence of such a declaration here means “Not specified; refer to CoA/Spec Sheet.”
  • Practical tips

    • For sensitive biological assays, verify sterility, endotoxin, and conductivity on the CoA. If sterility is required and not specified, sterile-filter (0.22 μm) into aseptic containers before use.
    • Because Ca2+ is present in typical lactated Ringer-type solutions (literature), confirm calcium content on the CoA if your application is calcium-sensitive (e.g., chelator studies, phosphate-containing media).
Reaction and Applications
  • Life-science and analytical workflows (general/literature)

    • Isotonic wash/perfusion medium for tissues and cells when calcium and potassium are required, and when low phosphate is preferred to avoid precipitation with calcium.
    • Sample handling/rinsing in workflows where chloride background is acceptable (e.g., conductometry calibration, electrode maintenance where compatible).
    • Short-term holding medium for cells or tissues under ambient CO2; lactate provides limited pH moderation but is not a strong buffer at neutral pH.
  • Chemical constraints

    • Not suited for water-sensitive reactions or metal-catalyzed organic synthesis; high ionic strength and dissolved Ca2+/Cl− can poison catalysts or drive side reactions.
    • Calcium readily forms insoluble salts with phosphate, carbonate, oxalate, and sulfate. Mixing LR with such anions can yield precipitates; visually inspect mixtures.
    • EDTA, EGTA, and other chelators will sequester Ca2+ and alter the solution’s effective composition.
  • Practical tips

    • If sterility is required and not specified, sterile-filter immediately after thawing and before use.
    • Equilibrate to the working temperature before making pH measurements; ionic activity and CO2 dissolution can shift apparent pH.
    • For electrophysiology or ion-sensitive assays, confirm exact ion concentrations on the CoA; do not assume literature ratios for this specific item.
Reaction Conditions

Conventional reaction condition guidance does not apply directly, as this product is a finished aqueous electrolyte solution rather than a reagent for chemical transformations.

  • Compatibility notes (general/literature)

    • Water-rich, high ionic strength medium; incompatible with water-sensitive reagents and many transition-metal catalysts.
    • Calcium and chloride ions may coordinate to catalysts or substrates, inhibiting reactivity; chloride can participate in ligand exchange.
    • Mixing with phosphate buffers can cause calcium phosphate precipitation; with carbonates/oxalates/sulfates, analogous precipitates may form.
  • Practical handling

    • If used as a matrix for bioconjugation or biomolecule handling, ensure the chemistry tolerates salts, Ca2+, and chloride. Many NHS-ester reactions and maleimide coupling steps prefer amine-free, phosphate-free buffers; check literature recommendations.
    • For enzymatic assays, verify that ionic strength and specific ions do not inhibit the enzyme of interest; Ca2+ is essential for some enzymes and inhibitory for others.

No temperature, time, or yield guidance is provided for this item; consult reaction-specific literature if considering use as an assay medium or carrier.

Safety and Handling
  • Hazard information (item-specific)

    • Signal Word: Not specified for this item; refer to SDS.
    • H-Statements: Not specified for this item; refer to SDS.
    • GHS Classification/Pictograms: Not specified for this item; refer to SDS.
  • General laboratory handling (for aqueous electrolyte solutions)

    • Use standard lab PPE: lab coat, safety glasses, and appropriate gloves. Avoid microbial contamination if sterile handling is required for your workflow.
    • Storage per product data: Store at -20°C. Note: Freezing may cause salt crystallization or phase separation; allow controlled thawing (2–8°C), then mix gently until fully homogeneous. Inspect for clarity and absence of particulates before use.
    • Incompatibilities: Calcium-containing solutions can precipitate with phosphates, carbonates, oxalates, and sulfates. Avoid mixing with concentrated phosphate buffers, EDTA (will chelate Ca2+), or reagents incompatible with chloride ions or high ionic strength (general/literature guidance).
    • Special risks: Not expected to form peroxides. Freezing/heating cycles can alter concentration via evaporation or cryoconcentration. Maintain container integrity to prevent contamination or evaporation.
  • First-aid overview (general)

    • Skin/eye contact: Rinse with water. Remove contaminated clothing. If irritation persists, seek medical attention.
    • Ingestion/inhalation: Rinse mouth, move to fresh air if aerosolized. Seek medical attention if unwell.

Always consult the product’s SDS for authoritative hazard, exposure controls, and disposal guidance. Dispose of salt solutions according to institutional and local regulations.

Solvent Selection

This product is itself an aqueous electrolyte solution rather than a solvent chosen for organic synthesis. Solvent selection in the classical sense is not typically applicable. However, for life-science workflows the following considerations are useful:

  • Polarity and miscibility

    • Highly polar and fully miscible with water; not miscible with most hydrophobic organic solvents. Mixing with high percentages of alcohols or acetone can induce salt precipitation (general/literature).
  • Functional role

    • Serves as an isotonic diluent, wash, or perfusate where modest buffering from the lactate/LA system and defined electrolytes (Na+, K+, Ca2+, Cl−) are desired (literature background).
  • When to choose versus alternatives (general)

    • Versus PBS: Lactated Ringer’s provides Ca2+ and lower phosphate; preferred when phosphate–metal precipitation is a concern or when Ca2+ signaling is relevant. PBS is preferred when defined phosphate buffering is required and Ca2+/Mg2+-free conditions are needed.
    • Versus Normal Saline (0.9% NaCl): Lactated Ringer’s supplies K+ and Ca2+ and lactate anion; saline is simpler and phosphate-compatible but lacks divalent cations and buffer capacity.
    • Versus HEPES-buffered saline: HEPES offers stronger buffering near pH 7.4; choose LR when minimal exogenous organic buffer is desired and calcium is needed.
Storage and Reconstitution
  • Item-specific storage and shipping

    • Storage Conditions: Store at -20°C (per product data).
    • Shipped In: Ice chest + ice pads (per product data).
  • Reconstitution/handling

    • This item is described as a solution; no reconstitution is specified. If frozen on receipt, thaw gradually at 2–8°C to minimize stratification and salt crystallization. Mix gently by inversion until homogeneous. Do not vortex if sterility is a concern.
    • After thawing, inspect for clarity, absence of particulates, and absence of persistent precipitate. If visible precipitate remains, warming to room temperature with gentle mixing may help redissolve salts; if unresolved, do not use.
    • If sterility is required and not specified on the CoA, sterile-filter through a 0.22 μm membrane into sterile containers.
  • Working aliquots and stability

    • Minimize freeze–thaw cycles by aliquoting upon first thaw. Record open/thaw dates. Avoid evaporation; recap promptly to maintain composition.
    • Protect from microbial contamination. For prolonged storage of opened containers, refrigeration (2–8°C) is typically preferred for aqueous salt solutions; however, defer to the CoA for any item-specific stability claims.
  • Specifications note

    • Exact composition, pH, and shelf life are Not specified for this item; refer to CoA/Spec Sheet.
Structure and Identity

Sodium lactate Ringer's solution is a multi-component aqueous electrolyte solution. For this catalog item, structural identifiers for a single molecule are not applicable.

  • Item-specific identifiers

    • CAS: Not specified for this item; refer to CoA/Spec Sheet.
    • Molecular Formula: Not specified for this item; refer to CoA/Spec Sheet.
    • Molecular Weight: Not specified for this item; refer to CoA/Spec Sheet.
    • SMILES: Not applicable for a multi-component solution; not specified for this item.
    • InChIKey: Not applicable for a multi-component solution; not specified for this item.
  • Composition context (literature/general)

    • “Ringer’s lactate” (also called lactated Ringer’s or Hartmann-type solution) typically contains sodium chloride, sodium lactate, potassium chloride, and calcium chloride in purified water (literature). The solution is electrically neutral overall and near-isotonic relative to physiological fluids (literature).
    • Functional motifs: inorganic ions (Na+, K+, Ca2+, Cl−) and the conjugate base of lactic acid (lactate, a 2-hydroxypropionate anion). No defined stereochemistry is assigned at the product level here; lactate in such solutions is commonly the L-isomer in literature formulations.
  • 2D description (general)

    • The solution comprises small inorganic ions dispersed in water and an organic alpha-hydroxycarboxylate anion (lactate). No ring systems or macromolecular structures are present. Because this is a mixture, a single structure depiction is not representative.
Synthetic Utility

As an aqueous salt mixture, sodium lactate Ringer’s solution is not typically employed as a reagent or solvent in organic synthesis.

  • Limited roles (general)

    • Aqueous phase/ionic strength modifier in educational demonstrations or benign extraction settings, acknowledging that high chloride and calcium contents can complicate metal-catalyzed processes and phase behavior.
    • Source of chloride and calcium ions for qualitative tests or instrument calibration (where concentrations are appropriate and documented on the CoA).
  • Constraints

    • Unsuitable for moisture-sensitive chemistries, organometallic reactions, and many catalytic processes due to water and dissolved ions.
    • Calcium precipitates with phosphate/carbonate/oxalate/sulfate; EDTA will chelate Ca2+, altering composition.

For synthetic work requiring aqueous media, select defined buffer systems or salt solutions with compositions matched to your reaction needs. Confirm this item’s exact composition on the CoA before any quantitative use.

Target Specificity

Not applicable. This product is an aqueous electrolyte solution and not a biological targeting reagent (e.g., antibody, probe, inhibitor). No target, epitope, species reactivity, clone, or isotype information applies.

Perguntas frequentes

How should this product be stored?
Store at ?20 °C. Freezer storage is required to maintain the specified shelf life.
How is this product shipped?
This product ships in an insulated container with ice pads. Unpack on arrival and transfer it to the storage condition stated above.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Deseja que lhe enviemos uma mensagem quando tivermos descontos disponíveis?

Lembrar-me mais tarde

Obrigado! Por favor, verifique a sua caixa de entrada de e-mail para confirmar.

Ops! As notificações estão desativadas.