Disponible para pedir
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
 ·  off list, applied to all prices below.
Size
Estado
Price
Qty
10T
P1456508-10T
8-12 wks(?) Production requires sourcing of materials. We appreciate your patience and understanding.
69,90US$
50T
P1456508-50T
8-12 wks(?) Production requires sourcing of materials. We appreciate your patience and understanding.
199,90US$
Enter a quantity for the sizes you want to add.

Descripción general

The purification kit is a highly efficient and flexible tool specifically designed for high-purity antibody purification from a variety of sample sources (such as serum, ascites, cell culture supernatant, or hybridoma supernatant). Unlike traditional pre-packed column kits, this kit does not include pre-packed columns or chromatography media. Instead, you can select and pack suitable media into empty columns of any scale according to your experimental needs, making it perfectly adaptable for both manual operation and automated purification systems. This product provides a high-concentration Protein A/G purification buffer, offering researchers maximum experimental flexibility to accommodate various empty chromatography columns, gravity-flow columns, or batch purification processes.

 

P1456508
Components
10T
50T
Storage
Quantity Per Test
P1456508A
Binding buffer(10×)
50 mL
250mL
2-8℃
5 mL
P1456508B
Elution buffer(5×)
10 mL
50 mL
2-8℃
1 mL
P1456508C
Neutralizer Buffer
10 mL
50 mL
2-8℃
1 mL
P1456508D
Coomassie Brilliant Blue Staining Solution
10 mL
50 mL
2-8℃
1 mL
P1455932E
Regeneration Buffer
10 mL
50 mL
2-8℃
10mL (Optional)

Note: The recommended amount of Purification resin for each test is 2 mL. 

Instructions for Use

Prior to use, dilute all component buffers to 1× concentration with deionized water. Specific operations can be adjusted according to the requirements of different purification tools.

I.     Sample Preparation

Before purification, clarify hybridoma supernatants, serum, or ascites samples by centrifugation or filtration through a 0.45 μm filter to avoid clogging the purification column and reducing its lifespan.

II.     Sample Purification

1.    Equilibration

Fill the purification column with 1× Binding Buffer (approximately 15 column volumes) to equilibrate the column, allowing the liquid to drain naturally.

2.    Sample Loading

Remove the top cap of the purification column and add the clarified sample to the Protein A purification column, allowing the liquid to drain naturally.

Note: If the antibody concentration in the sample is low or the sample volume is large, increase the number of loading cycles or extend the loading time to improve the binding efficiency between the antibody and the resin.

3.    Washing

Fill the purification column with 1× Binding Buffer (approximately 15 column volumes) to wash away unbound impurities, allowing the liquid to drain naturally.

4.    Elution

4.1 Prepare several 1.5 mL centrifuge tubes and pre-add 10 μL of Neutralizer Buffer to each tube.

4.2 Add 3 mL of 1× Elution Buffer (approximately 3 column volumes) to each purification column and collect the eluate by gravity. Collect 8 drops (approximately 0.5 mL) per tube and repeat until elution is complete.

5.  Dialysis

5.1 Take 2.5 μL of eluate from each tube, mix with 10 μL of Coomassie Brilliant Blue Staining Solution, and observe the gradient change of antibody elution.

5.2 Collect the eluate tubes with high antibody concentration and dialyze against an appropriate buffer to obtain highly purified IgG.

III.    Storage of Purification Column

1.    After antibody elution, add an additional 2 mL of 1× Elution Buffer to the column to wash away any residual antibody.

2.    Fill the purification column with 1× Binding Buffer (approximately 15 column volumes) to equilibrate the column, allowing the liquid to drain naturally.

3.    Fill the purification column with 20% ethanol (approximately 15 column volumes) for preservation, allowing the liquid to drain naturally.

4.    Add 5 mL of 20% ethanol to the column, cap the top, and seal the bottom cap. Store at 2-8℃ for direct use in subsequent purifications.

IV.   Column Regeneration (Optional)

Perform regeneration when a measurable decrease in column performance is observed, following these steps:

1.    Add 10 mL of Regeneration Buffer to the column for washing.

2.    Add 30 mL of double-distilled water (ddH₂O) to rinse the column thoroughly and remove residual Regeneration Buffer.

3.    Add 20 mL of 1× Binding Buffer to wash and equilibrate the resin.

4.    Add 15 mL of 20% ethanol for washing, then add 5 mL of 20% ethanol to the column. Cap the top and seal the bottom cap, and store at 2-8℃ 

Almacenamiento y envío
Condiciones de almacenamiento de almacenamiento
Store at 2-8°C
Enviado en
Wet ice
Estabilidad y almacenamiento
Store at 2-8°C long term (12 months).
Contents & Storage
P1456508
Components
10T
50T
Storage
Quantity Per Test
P1456508A
Binding buffer (10×)
50 mL
250 mL
2-8℃
5 mL
P1456508B
Elution buffer (5×)
10 mL
50 mL
2-8℃
1 mL
P1456508C
Neutralizer Buffer
10 mL
50 mL
2-8℃
1 mL
P1456508D
Coomassie Brilliant Blue Staining Solution
10 mL
50 mL
2-8℃
1 mL
P1455932E
Regeneration Buffer
10 mL
50 mL
2-8℃
10mL (Optional)

Note: The recommended amount of Purification resin for each test is 2 mL.

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificados (CoA, COO, BSE/TSE y tabla de análisis)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate TypeFechaArticulo