Bio-UltraBio™ One-step Firefly Luciferase Reporter Gene Assay Kit( Lyophilized )

Cat. No.: B1511294
Disponible para pedir
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. for Chemiluminescence ? Chemiluminescence grade — purity controlled to avoid quenching/background light. Use in chemiluminescent assays where signal fidelity is critical.
 ·  off list, applied to all prices below.
Size
Estado
Price
Qty
100T
B1511294-100T
8-12 wks(?) Production requires sourcing of materials. We appreciate your patience and understanding.
99,90US$
10×100T
B1511294-10×100T
8-12 wks(?) Production requires sourcing of materials. We appreciate your patience and understanding.
599,90US$
Enter a quantity for the sizes you want to add.
🧪

Why this grade

BioReagent,for chemiluminescence BioReagent,for Chemiluminescence for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Protected from light,Store at -20°C Ships Ice chest + Ice pads Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Descripción general

Genetic reporters are used commonly in cell biology to study gene expression and other cellular events coupled to gene expression, such as receptor activity, intracellular signal transduction, mRNA processing, protein folding and protein:protein interactions. Firefly luciferase is one of the most commonly used reporter genes in gene expression. It is an extremely sensitive, fast-responding and easy-to-use reporter gene. The chemiluminescence reaction it catalyzes is one of the most sensitive analytical tools for measuring gene expression.

Firefly luciferase is a protein with a molecular weight of approximately 61 kDa. In the presence of ATP, magnesium ions and oxygen, it can catalyze the oxidation of luciferin into oxyluciferin. During the oxidation process of luciferin, bioluminescence with a wavelength of approximately 560 nm is emitted, and this fluorescence can be measured by a chemiluminescence analyzer.

Bio-UltraBio™ One-step Firefly Luciferase Reporter Gene Assay Kit (Lyophilized) is  a one-step assay kit for directly measuring the intracellular firefly luciferase activity through chemiluminescence without the need for cell washing or collection. It features high sensitivity and high signal stability. This kit is a different packaging version of [O1375169] Bio-UltraBio™ One-step Firefly Luciferase Reporter Gene Assay Kit (Ready-to-use), and the detection signal intensities of the two are comparable. The signal half-life is approximately 2 hour. The detection reagent in the [O1375169] Bio-UltraBio™ One-step Firefly Luciferase Reporter Gene Assay Kit (Ready-to-use) is supplied as a ready-to-use liquid, offering the advantage of direct use without reconstitution. However, it requires storage at -80°C, and prolonged storage at -20°C may gradually reduce its detection performance.In contrast, this lyophilized powder product remains highly stable when stored at -20°C. For initial use, the firefly luciferase substrate must be reconstituted with the provided firefly luciferase detection buffer.

Precautions

1. For initial use, the firefly luciferase substrate must be reconstituted with the provided Firefly Luciferase Assay Buffer.

2. Repeated freeze-thaw cycles of the reconstituted Firefly Luciferase Substrate Detection Reagent should be minimized. It is recommended to aliquot the solution upon initial reconstitution and store it protected from light at -20°C or -80°C.

3. Avoid prolonged exposure of the reconstituted Firefly Luciferase Substrate Detection Reagent to room temperature.

4. The enzymatic reaction is temperature-sensitive. Both the cell culture plate and the detection reagent must be equilibrated to room temperature prior to assay initiation.

5. Detector Selection: Any instrument capable of measuring chemiluminescence is suitable for use with this kit. However, for identical samples, the background signal and measured values may vary between different detectors. Furthermore, readings obtained from different instruments for the same sample are not directly comparable.

6. To prevent well-to-well crosstalk, the use of opaque white or black cell culture plates is recommended.

Instruction for use 

1. Reagent preparation

Completely pour the Firefly Luciferase Detection Buffer into the vial containing the Firefly Luciferase Substrate. Invert the vial several times to fully dissolve the substrate.

Note: If the reconstituted Firefly Luciferase Detection Reagent is not fully used in a single experiment, it is recommended to aliquot it on ice immediately after reconstitution. The remaining aliquots should be stored at -20°C or -80°C.

2. Cell lysis

1) Adherent cells: Do not aspirate the cell culture medium; directly add the detection reagent of the same volume as the medium.

Suspended cells: The same as adherent cells.

2) Recommended usage volume:

Culture Vessel

96-well plate

48-well plate

24-well plate

12-well plate

6-well plate

Culture Medium Volume (μl/well)

100

150

200

300

500

Detection Reagent Volume (μl/well)

100

150

200

300

500

3) Lyse the cells for 5 minutes at room temperature, either on a microplate shaker or by standing.

3. Sample Addition

Samples in 96-well plates may proceed directly to the subsequent assay. For other sample types, pipette 200 μl of the mixed solution (culture medium + detection reagent) per well into the assay plate.

4.Detection

Initiate the chemiluminescence detector or a multifunctional microplate reader equipped with chemiluminescence functionality. Set parameters according to the instrument manual and experimental requirements, then proceed to measure the signal values.

Almacenamiento y envío
Condiciones de almacenamiento de almacenamiento
Protected from light,Store at -20°C
Enviado en
Ice chest + Ice pads
Estabilidad y almacenamiento
Bio-UltraBio™ One-step Firefly Luciferase Reporter Gene Assay Kit (Lyophilized): Each component has a shelf life of 1 year under under corresponding storage conditions.  B1511294A Firefly luciferase Detection buffer: Store at -20℃ long term. B1511294B Fir
Contents & Storage

B1511294

Components

100T

10 × 100T

Storage

Quantity Per Test

B1511294A

Firefly luciferase detection buffer

10 mL

10×10ml

-20℃

100μL

B1511294B

Firefly luciferase substrate

1 vial

10 vials

-20℃, Store in the dark.

100μL (After reconstitution )


Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificados (CoA, COO, BSE/TSE y tabla de análisis)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate TypeFechaArticulo
ZJ26F0434213Certificate of AnalysisApr 17, 2026 B1511294
Preguntas frecuentes y artículos
Calculadoras de soluciones
Reseñas

Reseñas de cliente

Need help choosing the grade?

Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.

View BioReagent grade guide → View for Chemiluminescence grade guide →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.