Bromophenol Blue Aqueous Solution (1%) - BioReagent

Cat. No.: B1528873
Disponible para pedir
CALIDAD & PUREZA BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. Suitable for electrophoresis ? Electrophoresis grade — low ionic/UV impurities for clean gel runs. Use in agarose/PAGE electrophoresis where impurities distort bands. Color change range: pH 3.0 (yellow) – pH 4.6 (blue)
Storage
Room temperature
Shipped In
Normal
Application
1192,1193
★
Talla
USA
Alemania (EU)*
Precio
Cantidad
10ml
B1528873-10ml
Fabricado bajo pedido · 8–12 semanas
16,90US$
Enter a quantity for the sizes you want to add.

Descripción general

Bromophenol blue is a pH indicator that changes color from yellow to blue over the pH range of 3.0–4.6. It is commonly used as an electrophoresis tracking dye to indicate the migration of small nucleic acids or proteins in gels, and is a widely used molecular biology reagent.

Procedure (for reference only):

Perform the operation according to the specific requirements of the experiment.

Precautions:

1.For your safety and health, please wear a lab coat and disposable gloves during operation.

2.This product is for research use only and must not be used for other purposes.

Especificaciones

Especificaciones y pureza
BioReagent, Suitable for electrophoresis, Color change range: pH 3.0 (yellow) – pH 4.6 (blue)
Estabilidad y almacenamiento
Store at RT long term (12 months).
Condiciones de almacenamiento de almacenamiento
Room temperature
Enviado en
Normal
Grado
BioReagent, Suitable for electrophoresis
Product Line
B1528873-10ml

Datos avanzados

Certificados (CoA, COO, BSE/TSE y tabla de análisis)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Calculadoras de soluciones
Reseñas

Reseñas de cliente

Application Protocols
  • No vendor-validated protocols are provided for this item. Below are general literature-style starting points; optimize for your system.

  • SDS-PAGE sample buffer (example workflow):

    • Prepare 2× loading buffer containing Tris-HCl, SDS, glycerol, and a reducing agent as required. Add bromophenol blue from the 1% stock to achieve 0.01% (w/v) in the 2× buffer. Mix with sample 1:1 and load. Adjust dye level for optimal visibility.
  • Agarose gel loading dye (example workflow):

    • To a viscous base (e.g., 30% glycerol or 40% sucrose in buffer), add the 1% stock to reach 0.01% (w/v). Optionally include a second tracking dye (xylene cyanol) for dual-front tracking. Load 1 part dye to 5–10 parts sample.
  • pH indicator for buffer prep (example workflow):

    • Add 1–2 drops of the 1% solution per 100 mL of acidic buffer under preparation. Titrate acid/base to the desired pH within the indicator range, then verify with a calibrated pH meter.

These protocols are generic guidance and not validated for this specific product lot; adjust concentrations and procedures to your laboratory requirements.

Biological Roles
  • Item relevance: This product is a laboratory indicator/tracking dye solution and does not have an intrinsic biological role in metabolism or signaling.

  • Literature context for bromophenol blue:

    • Not a natural metabolite; functions as a pH-sensitive chromophore that changes color with protonation state of phenolic groups.
    • In biochemical workflows, serves operational roles:
      • Visual tracking during electrophoresis of nucleic acids and proteins.
      • Visual endpoint indicator in acidic buffer/titration preparations.
    • Interactions: The sulfonated, phenolic dye can exhibit weak, nonspecific interactions with proteins, especially under acidic conditions; this is exploited only for visualization in some staining protocols but is not used for quantitative binding studies.
  • Compatibility with biological samples:

    • At typical working concentrations, it has negligible impact on biomolecule integrity in standard electrophoresis buffers. However, confirm that it does not interfere with specific downstream spectrophotometric assays (absorbance in visible region) or colorimetric enzyme assays.
  • Safety note: Use is limited to research applications. No medical, diagnostic, or therapeutic roles are implied or supported.

Buffer Applications
  • pH indication (literature guidance):

    • Bromophenol blue exhibits a color transition over approximately pH 3.0–4.6, shifting from yellow (acid form) to blue/purple (base form). This makes it suitable for monitoring preparation and titration of citrate, acetate, or formate buffers in the acidic range.
    • Practical use: add small aliquots of the 1% stock to the buffer under preparation, targeting a final dye level of 5–50 µM or 0.001–0.01% (w/v) depending on visibility and background needs. Verify the indicator does not interfere with downstream assays.
  • Electrophoresis sample buffers:

    • Protein SDS-PAGE (Tris-glycine): Include bromophenol blue in the sample loading buffer to track the leading ion front. The dye migrates rapidly, reaching the bottom near completion of the separation (literature practice). For Tris-Tricine systems, adjust expectations for different migration behavior.
    • Nucleic acid gels (agarose, PAGE): Combine with glycerol or sucrose in loading buffer to visualize sample entry and migration. The dye fronts provide coarse size-position markers when used alongside other dyes (e.g., xylene cyanol).
  • Practical tips:

    • Ionic strength and co-solutes (SDS, urea, salts) can subtly shift indicator color; calibrate once under your exact buffer composition.
    • Store prepared working buffers containing dye protected from strong light to preserve consistent color intensity.
Green Alternatives
  • Environmental and safety perspective:

    • An aqueous 1% solution avoids flammable organic solvents and minimizes volatile organic compound (VOC) exposure. Disposal considerations remain, as dye effluents can be environmentally persistent; follow institutional waste procedures.
  • Alternative indicators/tracking dyes (literature comparison):

    | Option | Typical use case | pH transition / behavior | Pros | Cons | |---|---|---|---|---| | Bromophenol blue (this product) | Fast front tracking in PAGE; acidic pH indication | ~3.0–4.6 | Strong color; works at very low concentrations; aqueous | Narrow pH range; may weakly bind proteins at low pH | | Xylene cyanol FF | Slower front tracking | Not an acid-base indicator | Distinct migration rate enables multi-band tracking | Less intense color; not an indicator | | Bromocresol green | Indicator in slightly higher pH | ~3.8–5.4 | Broader overlap near pH 4–5 | Different migration behavior in gels | | Natural indicators (e.g., anthocyanins) | Educational/low-toxicity demos | Broad, matrix-dependent | Renewable sources | Poor reproducibility; unstable vs pH/ionic strength |

  • Greener practice tips:

    • Use minimal effective dye concentration; collect dye-containing aqueous waste separately for proper treatment.
    • Prefer re-usable gel cassettes and minimize rinses with large volumes of water containing dyes.
Pharmaceutical Uses
  • This product is intended for research use only and is not manufactured to GMP or pharmacopeial monograph specifications.

  • Potential roles in pharmaceutical laboratories (general, non-clinical):

    • Visual indicator in acid-range titrations during method development or QC of excipients/actives (bench-scale, non-GMP contexts unless validated).
    • Tracking dye for monitoring flow or mixing in process development studies, where visible tracers aid visualization.
  • Not typically used as an excipient or in finished drug formulations. Any use in regulated environments would require suitability assessments, impurity profiling, and adherence to validated procedures beyond the scope of this listing.

  • Pharmacopeia status: Not specified for this item; refer to internal QA or pharmacopeial references if required.

Physical Properties
  • Item-specific physical parameters (solution):

    • Concentration: 1% (w/v) bromophenol blue in water.
    • Appearance, pH, density, refractive index, and UV-Vis data for this lot: Not specified for this item; refer to CoA/Spec Sheet.
  • General properties (literature, for bromophenol blue solute):

    • Acid–base transition (indicator range): approximately pH 3.0–4.6, with color change from yellow (acid) to blue/purple (basic form).
    • Strong visible absorbance in the 430–600 nm region depending on pH, enabling use at very low concentrations as a tracking dye.
    • High molar absorptivity typical of sulfonephthalein dyes; ionization enhances water solubility.
  • Solution behavior (general guidance):

    • Miscible with aqueous buffers; compatible with common electrophoresis sample buffers (e.g., Tris-glycine, MES, MOPS) and with denaturants (SDS, urea) at typical loading-dye levels.
    • Working concentration in gels is often in the 0.001–0.02% (w/v) range (literature); this 1% stock is typically diluted accordingly.

Note: Do not treat the literature ranges above as specifications for this product. For lot-specific attributes (e.g., exact absorbance at a given wavelength/pH), consult the CoA or SDS.

Quality and Grades
  • Item grade: BioReagent (item-specific).

    • BioReagent grade generally indicates suitability for common biochemical workflows (e.g., electrophoresis, buffer preparation), with attention to impurities that may interfere with biological assays. It does not imply clinical/diagnostic suitability.
  • What this means in practice:

    • Expect low levels of insoluble particulates and consistent dye performance in tracking and indicator roles.
    • UV-absorbing impurities and metal content are not specified for this item; refer to CoA/Spec Sheet if such parameters are critical to your application.
  • Stabilizers and additives: Not specified for this item; refer to CoA/Spec Sheet.

  • Batch-to-batch consistency:

    • For colorimetric indicators, lot-controlled absorbance versus pH is important. Users performing quantitative colorimetric work should verify extinction coefficients under their buffer conditions.
  • Suitability notes:

    • Appropriate for research use in life science workflows, including preparation of electrophoresis sample buffers and as a pH indicator in acidic buffer systems.
    • Not intended for clinical or diagnostic procedures.
Reaction and Applications
  • Primary research applications (expanding on typical catalog use):

    • Electrophoresis tracking dye: Added to nucleic acid or protein sample loading buffers, bromophenol blue provides a fast-moving front that indicates gel run progress. In SDS-PAGE, the dye front typically migrates near the ion front, helping time the run and stop before the dye exits the gel (literature practice).
    • pH indicator in acidic range: Useful for monitoring titrations and buffer preparations in the pH ~3.0–4.6 transition range (literature). Color shifts from yellow (acid) to blue/purple (less acidic), offering a visual endpoint.
    • Visual tracer: Employed to visualize solution movement in microfluidics, chromatography packing, or general lab workflows where a low-level tracer is helpful.
  • Practical tips:

    • Prepare working solutions by diluting the 1% stock into your sample buffer to reach typical loading dye levels (often 0.001–0.02% w/v in final samples, literature). Verify that the dye does not obscure detection wavelengths for downstream assays.
    • In protein work, the dye can weakly bind proteins at low pH; for analytical staining, use dedicated stains (e.g., Coomassie) after electrophoresis rather than relying on bromophenol blue color.
    • For nucleic acids, the dye is non-intercalating and does not replace fluorescent stains for detection; it is purely for tracking migration.
  • Compatibility:

    • Functions well with standard Tris-glycine, Tris-Tricine, MES, and MOPS systems. High salt or extreme pH may alter color or mobility; standardize conditions across experiments.
Reaction Conditions

Specific reaction conditions are not typically applicable to an aqueous indicator/tracking dye solution. However, for laboratory use the following general guidance applies (literature context):

  • Working concentration ranges:

    • Electrophoresis loading buffers: often 0.001–0.02% (w/v) bromophenol blue final concentration.
    • pH indication in buffers: minimal amount required for visible color, commonly in the low micromolar range.
  • Environmental parameters:

    • Temperature: ambient conditions are standard; color is primarily pH-dependent and only weakly temperature sensitive in common lab ranges.
    • pH: observable transition ~3.0–4.6 (indicator behavior), enabling qualitative monitoring of acidity.
  • Compatibility:

    • Stable in aqueous salts, Tris, citrate, acetate, MES/MOPS systems; color can be influenced by ionic strength and co-solutes. Avoid strong oxidants/reductants that may bleach the dye.

These are general literature guidelines for using bromophenol blue as an indicator or tracker, not specifications for this specific item.

Safety and Handling
  • GHS classification, signal word, pictograms, and H-statements: Not specified for this item; refer to SDS for authoritative safety information.

  • General laboratory safety (appropriate for dye solutions):

    • PPE: lab coat, safety glasses, and suitable gloves (e.g., nitrile). Avoid skin/eye contact—solutions can strongly stain and may cause irritation.
    • Hygiene: prevent ingestion and inhalation of aerosols; wash exposed skin after handling. Handle in a clean area to avoid staining equipment and benchtops.
    • First aid (overview; defer to SDS): rinse eyes/skin with water for several minutes if contacted; remove contaminated clothing; seek medical attention if irritation persists. If ingested, rinse mouth; do not induce vomiting—obtain medical advice.
  • Chemical incompatibilities and stability (general):

    • Stable as an aqueous dye at ambient conditions. Extreme pH or strong oxidizers can degrade the chromophore. Avoid strong reducing agents that may alter color or structure.
    • Light sensitivity is modest; store in amber or away from strong light to maintain color integrity over time (general precaution for indicators).
  • Spill/cleanup: absorb with inert material and rinse area with water; dye may leave persistent stains—use appropriate detergents or dilute bleach for decolorization of surfaces where compatible.

Always consult the product SDS for definitive hazard classifications and response measures.

Solvent Selection
  • This product is an aqueous solution. No solvent selection is required for use as a stock indicator/tracking dye. For dilution or formulation, use water or the target buffer system.

  • Miscibility and compatibility (general):

    • Fully miscible with water and standard biological buffers (Tris, phosphate, citrate, acetate, MES, MOPS, glycine). Compatible with SDS- and urea-containing solutions at typical loading-dye concentrations.
    • In organic-rich systems (e.g., >50% organic solvents), color and ionization may shift; verify performance if adding to mixed solvent systems.
  • When to adjust matrix:

    • For electrophoresis, dilute the 1% stock directly into sample loading buffer to achieve the typical tracking dye concentration used for your gel format.
    • For pH indication, add small aliquots to the working aqueous buffer and confirm that ionic strength and pH range (literature transition ~3.0–4.6) are appropriate.
  • Alternatives and comparisons (literature context):

    • Xylene cyanol FF tracks slower in PAGE and may be preferable for resolving very small fragments; bromocresol green has a different pH transition (approx. 3.8–5.4). Choose based on desired migration rate or pH window.
Storage and Reconstitution
  • Storage conditions (item-specific): Room temperature. Shipped under normal conditions.

  • Container handling:

    • Keep tightly closed to prevent evaporation and contamination. Store away from strong light to maintain color fidelity over time.
  • Reconstitution: Not applicable; the product is supplied as a ready-to-use 1% aqueous solution.

  • Stability and inspections:

    • If precipitate or color fading is observed, mix thoroughly to re-homogenize. Persistent precipitation or unexpected color changes may indicate contamination or degradation; prepare fresh solution or consult CoA/SDS.
    • Do not freeze unless validated for your workflow; freeze–thaw cycles can cause concentration gradients or container stress.
  • Compatibility notes:

    • For preparing working solutions, dilute with high-purity water or your target buffer. Record final concentrations to ensure run-to-run consistency in electrophoresis and buffer preparation.
  • Expiry/shelf-life: Not specified for this item; refer to CoA/Spec Sheet.

Structure and Identity
  • Item-specific: 1% aqueous solution of bromophenol blue (w/v), supplied ready-to-use.

  • SKU: B1528873; Grade: BioReagent.

  • CAS, InChIKey, SMILES, molecular formula, and molecular weight: Not specified for this item; refer to CoA/Spec Sheet.

  • Structural description (literature, for the solute bromophenol blue):

    • Bromophenol blue is a sulfonephthalein dye bearing multiple bromine substituents on a triphenylmethane-like core with a central sulfonyl bridge and phenolic groups. It exists as differently colored acid/base forms due to phenolic protonation state.
    • Functional groups: phenols (acid-base responsive), aryl bromides, sulfone/sulfonate features contributing to water solubility in ionic forms.
    • 2D structure in words: three aromatic rings connected through a central sp3-like carbon in the phthalein scaffold; a sulfone bridge links to a benzenesulfonate-type moiety; two phenolic oxygens capable of ionization; heavy bromination increases molar absorptivity and bathochromic shift.
  • Synonyms (literature): bromophenol blue; BPB; Tetrabromophenolsulfonephthalein.

Note: Structural identifiers above are provided as general literature context for the indicator dye used in this solution and are not item-specific specifications.

Synthetic Utility

As a ready-to-use aqueous indicator solution, this product is not generally employed as a reagent or building block in synthetic transformations. It serves primarily as a visualization aid. For chemical synthesis involving dyes or sulfonephthalein derivatives, neat bromophenol blue (solid) or suitably protected intermediates would be the appropriate starting materials. If your workflow requires a pH-responsive chromophore during a reaction (e.g., to visualize acidity changes), small additions of this solution can provide qualitative feedback but are not substitutes for quantitative pH control or titration.

Target Specificity

Not applicable. This product is a chemical indicator/tracking dye solution and is not an antibody, affinity reagent, or probe with biological target specificity.

¿Quieres que te enviemos un mensaje cuando tengamos descuentos disponibles?

Recordármelo más tarde

¡Gracias! Por favor, revisa tu bandeja de entrada de correo electrónico para confirmar.

¡Vaya! Las notificaciones están desactivadas.