GRADE & PURITYValidated?Validated grade — performance confirmed in defined applications before release. Use when you want documented assurance the reagent works as stated.ExactAb™?ExactAb™ — Aladdin's antibody line emphasizing precision and validated quality. Use for reliable, specificity-validated antibody applications.Ex:498nm?Fluorescence excitation maximum at 498 nm — the wavelength of light that best excites this fluorophore. Match it to your instrument's laser or filter set for the strongest signal.Em:517nm?Fluorescence emission maximum at 517 nm — the wavelength this fluorophore emits after excitation. Use it to pick the right detection filter and avoid channel cross-talk.0.5 mg/mL
Integrin alpha-X/beta-2 is a receptor for fibrinogen. It recognizes the sequence G-P-R in fibrinogen. It mediates cell-cell interaction during inflammatory responses. It is especially important in monocyte adhesion and chemotaxis.
Especies hospedadoras
Armenian hamster
Especificidad
CD11c
Inmunógeno
Mouse dendritic cells
Control positivo
Flow: C57BL/6 mouse splenocytes.
Conjugación
FITC
Excitación (nm)
Blue Laser(488nm)
Emisión (nm)
517nm
Ex/Em(nm)
Ex:498nm;Em:517nm
Grado
Em:517nm, Ex:498nm, ExactAb™, Validated
Isotipo
Armenian Hamster IgG
Método de purificación
Protein G purified
Concentración
0.5 mg/mL
Almacenamiento y envío
Condiciones de almacenamiento de almacenamiento
Store at 2-8°C,Protected from light,Do not freeze
Enviado en
Wet ice,Do not freeze
Estabilidad y almacenamiento
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Imágenes
CD11c Armenian Hamster mAb (FITC) (Ab178874) - Flow Cytometry Two-color flow cytometric analysis of CD11c expression on mouse splenocytes. C57BL/6 mouse spleen cells were stained with MHC Class II Rat mAb (APC) (Ab187213) and either Armenian Hamster IgG (FITC) (Ab191747; Left panel) or CD11c Armenian Hamster mAb (FITC) (Ab178874; Right panel) at 3 μg/mL. Total viable cells were used for analysis.
Aplicación
Aplicación
Dilution info
Flow Cytometry
≤1.0 μg/test,
the suggested use of this reagent is ≤1.0 μg per million cells in 100 µL staining volume
Documentation
📋 Safety Data Sheet (SDS)
Comprehensive hazard, handling, storage, and regulatory compliance document.
We use cookies to ensure the website functions properly and, where permitted, to improve your experience. You can manage your preferences at any time in Settings. Learn more in our Cookie Policy.
Shall we send you a message when we have discounts available?
Remind me later
Thank you! Please check your email inbox to confirm.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.