DBCO PEG Amine, DBCO-PEG-NH2 - MW 5000 Da

Cat. No.: D163521
Disponible para pedir
CALIDAD & PUREZA MW 5000 Da
Storage
Room temperature
Shipped In
Normal
★
Talla
USA
Alemania (EU)*
Precio
Cantidad
20mg
D163521-20mg
Fabricado bajo pedido · 8–12 semanas

1.183,90US$

1.381,90US$
Guardar 198,00 US$ (14.33%)
Enter a quantity for the sizes you want to add.

Especificaciones

Especificaciones y pureza
MW 5000 Da
Condiciones de almacenamiento de almacenamiento
Room temperature
Enviado en
Normal

Datos avanzados

Certificados (CoA, COO, BSE/TSE y tabla de análisis)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Preguntas frecuentes y artículos
Calculadoras de soluciones
Reseñas

Reseñas de cliente

Application Protocols

Note: No item-specific, tested protocols are provided in the Product Data. The following are general literature-style procedures to guide use. Adjust to your system.

A. Installing DBCO-PEG-NH2 onto a carboxylated protein (EDC/sulfo-NHS)

  • Buffer exchange protein into 50 mM MES, pH 5.8 (no amines). Add EDC (5–10 mM) and sulfo-NHS (10–25 mM) to activate for 15–30 min at room temp.
  • Adjust to pH 7.8–8.2 with 10× HEPES or phosphate. Add DBCO-PEG-NH2 at 2–10 equiv per estimated accessible carboxyl group or 3–10 equiv per protein lysine target; react 1–2 h at RT (or 4 °C overnight).
  • Quench with 20 mM Tris or 50 mM ethanolamine. Purify by desalting column (e.g., 7 kDa MWCO). Verify DBCO incorporation by UV or MS.

B. SPAAC with an azide-labeled partner

  • Prepare conjugation buffer: PBS, pH 7.4 (no sodium azide). Combine DBCO-bearing material with azide partner at 1.1–2.0 equiv DBCO per azide site, final concentration 10–100 µM (biomolecules).
  • Incubate 30–120 min at 20–37 °C with gentle mixing. Optional: include 5–10% DMSO to aid solubility. Monitor by MS or SEC.
  • Purify by SEC, dialysis, or spin filtration.

C. Small-molecule amide coupling (HATU)

  • Dissolve carboxylic acid (1.0 equiv) and DBCO-PEG-NH2 (1.2–1.5 equiv) in anhydrous DMF (0.05–0.2 M). Cool to 0 °C; add HATU (1.2–1.5 equiv) and DIPEA (2–4 equiv). Stir 1–3 h at 0–25 °C.
  • Quench with water, extract with EtOAc, wash, dry, and purify by chromatography.

General tips

  • Avoid Tris/glycine buffers during NHS coupling; avoid sodium azide during SPAAC.
  • Protect from strong light; store and handle under dry conditions for best performance.
Biological Roles

Item-specific biological roles

  • None specified; this product is a synthetic reagent for research use only.

General context (literature)

  • Bioorthogonality: DBCO–azide SPAAC proceeds without interfering with native biological functional groups, enabling labeling in complex media and on living systems (when cell-compatible conditions are used).
  • PEG effects: The PEG spacer reduces nonspecific binding, improves aqueous dispersibility, and can increase hydrodynamic radius, thereby enhancing accessibility of the DBCO group to azide partners on biomolecules or surfaces.
  • Azide introduction: Azido groups are often incorporated metabolically (e.g., azido sugars into glycans) or via synthetic modification (NHS–azide reagents) to create SPAAC-ready targets.
  • Applications in biochemical workflows: Affinity tagging, imaging probe attachment, pull-down assays, creation of triazole-stabilized conjugates, and distance-controlled multivalent displays using PEG spacers.

Limitations/considerations

  • Reaction selectivity relies on the absence of competing azides; buffers preserved with sodium azide will consume DBCO.
  • The amine terminus can engage in side reactions with electrophiles in biological matrices; protect or block as needed if only the DBCO is intended to react.

Note

  • No therapeutic/clinical role is claimed. Use is restricted to laboratory research, assay development, and materials preparation.
Buffer Applications

Applicability

  • This reagent is not a buffering agent. However, buffer choice is critical for its two primary uses: (1) amide coupling via the terminal amine and (2) SPAAC via the DBCO.

Recommended buffer systems (general/literature)

  • NHS/EDC coupling to carboxyls:
    • Buffer: 50–100 mM phosphate or HEPES, pH 7.5–8.5; alternatively 50–100 mM bicarbonate, pH ~8.3 for direct NHS reactions.
    • Avoid: Primary amine-containing buffers (Tris, glycine) during coupling as they compete with the reagent.
  • SPAAC with azides:
    • Buffer: PBS or HEPES, pH 6.5–8.0. Ionic strength (100–300 mM NaCl) can reduce nonspecific interactions without impairing click kinetics.
    • Compatibility: Catalyst-free; Mg2+/Ca2+ salts, mild detergents (0.01–0.1% Tween-20), and 0–20% DMSO or DMF cosolvent are generally tolerated by SPAAC.

Practical buffer tips

  • Degassing is not required for SPAAC. Maintain neutral pH to preserve protein integrity.
  • For sensitive proteins, include 0.5–2 mM EDTA only if metal chelation is needed; EDTA is compatible with SPAAC but avoid sodium azide preservatives.
  • After coupling, remove excess reagent by desalting columns (e.g., 7–10 kDa MWCO for proteins) or dialysis into storage buffer.
Green Alternatives

Context

  • DBCO-PEG-NH2 is a high-value bioconjugation reagent used in small amounts. While not a bulk solvent, greener choices can be made in solvent and reaction design.

Greener design choices (general)

  • Copper-free SPAAC vs CuAAC: SPAAC avoids copper catalysts and associated chelators, reducing metal waste and cytotoxicity in biological workflows.
  • Aqueous media: Favor buffered aqueous systems (PBS, HEPES) with minimal organic cosolvent for SPAAC steps when solubility permits.
  • Safer coupling agents: For amide formation, consider water-soluble carbodiimides (EDC) with NHS over uronium/PHOS coupling reagents that can be more hazardous.

Alternative click handles (comparison; literature)

  • BCN/DIBAC vs DBCO: Similar copper-free reactivity; BCN variants can offer different solubility and stability profiles. Choice may depend on payload hydrophobicity and protein compatibility.
  • Tetrazine–TCO (iEDDA): Faster kinetics in water and no catalyst; however, tetrazines can be air/light sensitive and less robust than DBCO in storage.

Mini-comparison table (general)

  • SPAAC (DBCO): Catalyst-free, moderate–fast rates, robust storage; sometimes needs organic cosolvent.
  • SPAAC (BCN): Catalyst-free, good aqueous compatibility for some analogs; slightly different kinetics.
  • iEDDA (TCO–tetrazine): Very fast, fully aqueous; reagents can be less stable and more costly.

Operational tips

  • Use high-atom economy linkers and minimize protecting groups.
  • Recover and appropriately dispose of DMF/DMSO; consider MeCN or greener solvents if compatible.
Pharmaceutical Uses

Item-specific regulatory/compendial status

  • Not specified for this item; refer to CoA/Spec Sheet. Supplied for research use only.

General roles in pharmaceutical R&D (literature)

  • Bioconjugation scaffold: DBCO-PEG-NH2 is used to introduce a SPAAC-ready handle onto drug candidates, peptides, proteins, polymers, and nanoparticles via amide bond formation. This enables modular attachment of azide-bearing payloads (imaging labels, affinity tags, solubilizers).
  • Process development: Evaluating linker length (PEG units) to tune PK/PD surrogates, sterics, and hydrodynamics in preclinical materials.
  • Analytical conjugation standards: Preparation of model conjugates for method development (HIC, SEC, CE-SDS, LC–MS) without introducing copper.
  • Device/surface modification: Functionalization of diagnostic surfaces and delivery devices to immobilize azide-containing capture ligands.

Manufacturing considerations (general)

  • Reagent quality: Low endotoxin/bioburden and defined PEG polydispersity may be desired depending on application; verify with supplier documentation.
  • Residuals: Removal of DMF/DMSO and coupling byproducts via diafiltration or chromatography is standard.
  • Stability: Protect from light and store as directed. Validate shelf life and reactivity in your process.

Note

  • No therapeutic claims are made. This product is not an API or excipient as supplied; it is a research reagent used to assemble conjugates in development settings.
Physical Properties

Item-specific data (from Product Data)

  • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
  • Other specs (MP/BP, density, solubility, pKa, logP, UV cutoff, water/peroxide/metal limits): Not specified for this item; refer to CoA/Spec Sheet.

General/literature guidance for DBCO–PEG–NH2 class

  • Physical form: Typically off-white solid or viscous syrup depending on PEG length (short PEGs often waxy solids; longer PEGs viscous oils).
  • Solubility profile: PEG imparts good solubility in polar aprotic solvents (DMSO, DMF, NMP, acetonitrile) and mixed aqueous/organic systems. Many DBCO–PEG–NH2 variants are soluble to partially soluble in water; solubility improves with longer PEG.
  • pKa (amine, literature): Primary aliphatic amine conjugate acid pKa typically ~9–10; effective nucleophilicity for amide coupling near pH 7.5–8.5.
  • Stability: DBCO strained alkyne is stable under neutral conditions but can undergo slow reaction with azides and certain nucleophiles; light and heat can accelerate side reactions. PEG and amine are generally robust.
  • Hygroscopicity: PEG chains can be mildly hygroscopic; handle under dry conditions for moisture-sensitive couplings.

Practical handling implications (general)

  • Avoid prolonged exposure to strong acids/bases and oxidants.
  • For accurate solubility and extinction coefficients of a specific lot/length, consult the CoA/Spec Sheet.
Quality and Grades

Item-specific grade/purity (from Product Data)

  • Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.

How to interpret quality for this reagent class (general guidance)

  • Functional integrity: For DBCO–PEG–NH2, the key quality attributes are (a) DBCO functionality (active strained alkyne, low polymeric or oxidized byproducts), (b) PEG length distribution (polydispersity), and (c) free amine content (titrable amine).
  • Typical assays (literature/industry): NMR to confirm DBCO aromatic and alkyne signals; LC–MS or MALDI to assess MW distribution; HPLC/UPLC purity; amine value (TNBS or NMR integration); residual solvents and water by KF.
  • Stabilizers: These materials are commonly supplied without stabilizers; if any stabilizer or salt form is used, it will be disclosed on the CoA. Implications: stabilizers can affect reactivity in conjugation; check documentation before critical applications.
  • Absorbance/UV: DBCO chromophore exhibits UV absorbance in the near-UV; if low-UV background is required (e.g., analytical methods), verify with the CoA.
  • Trace metals/peroxides: Not specified for this item; refer to CoA/Spec Sheet. For sensitive bioconjugations, low metal content may be desirable.

Practical recommendations

  • Request a CoA with exact PEG length distribution and purity for method validation.
  • For regulated workflows, qualify a lot by in-house test coupling to an NHS ester and an azide model substrate to confirm performance.
Reaction and Applications

Core reactions (literature)

  • Copper-free click (SPAAC): Strained alkyne (DBCO) reacts rapidly and selectively with organic azides to form triazoles without Cu(I) catalysis. Effective in live-cell compatible buffers and on biomacromolecules.
  • Amide formation: Terminal primary amine enables conjugation to carboxylic acids via NHS esters, carbodiimide coupling (EDC/NHS), or activated carbonates.

Representative applications (general)

  • Two-step bioconjugation: Install DBCO-PEG-NH2 onto carboxyl-bearing biomolecules (proteins, polymers, nanoparticles), then click with azide-bearing probes, polymers, or payloads.
  • Surface functionalization: Introduce DBCO handles on carboxylated surfaces (COOH-terminated SAMs, carboxylated polystyrene, silica) for subsequent azide immobilization.
  • Polymer chemistry: Synthesize block copolymers or networks via SPAAC, controlling spacing with PEG length to reduce steric hindrance and improve hydration.
  • ADC/biomaterial research: Use the amine to couple to activated linkers or spacers; employ DBCO for site-selective labeling of azide-tagged residues.

Practical tips (general)

  • Keep reagents and glassware free of adventitious azides (e.g., from NaN3-preserved buffers) unless intended for reaction.
  • For NHS coupling, maintain pH 7.5–8.5; minimize primary amine buffers (Tris) during coupling to avoid competition.
  • SPAAC is effective across pH 6–8; reaction rate increases with temperature and concentration; PEG helps mitigate aggregation.
  • Analyze conversions by LC–MS, SDS-PAGE (for proteins), or SPR/QCM for surfaces. Remove excess reagent by desalting or dialysis as appropriate.
Reaction Conditions

The following are general literature guidelines; optimize per system. No item-specific specifications are provided in the Product Data.

SPAAC (DBCO + Azide)

  • Solvent/buffer: PBS or HEPES, pH 6.5–8.0; 0–20% DMSO/DMF cosolvent if needed for solubility.
  • Concentration: 10–500 µM for biomolecules; 1–50 mM for small-molecule synthesis.
  • Stoichiometry: 1.1–2.0 equiv DBCO per azide site for complete conversion on biomolecules.
  • Temperature/time: 20–37 °C; minutes to a few hours depending on concentration and sterics. Gentle mixing; no degassing required.
  • Notes: Exclude sodium azide; light protection can minimize side reactions.

Amide coupling (installing DBCO-PEG-NH2 onto carboxyls)

  • Activation: EDC (1–1.5 equiv) + NHS or sulfo-NHS (1.2–2 equiv) in aqueous buffer pH 5.5–6.0 for activation, then adjust to pH 7.5–8.5 for amine coupling; or use NHS-activated esters directly.
  • Organic media alternative: In anhydrous DMF or DCM, use HATU/HOAt or TBTU with DIPEA (2–4 equiv) at 0–25 °C for 0.5–4 h for small molecules.
  • Protein conjugation: Work at 4–25 °C, pH 7.5–8.3, with limited organic cosolvent. Quench unreacted NHS esters with Tris or ethanolamine after coupling.

Workup/purification

  • Small molecules: Aqueous workup, extraction, and silica or reverse-phase chromatography (protect DBCO from prolonged strong acid/base).
  • Bioconjugates: Desalting columns, dialysis, spin filters (MWCO 3–30 kDa), or size-exclusion chromatography.

Analytics

  • Follow reaction by LC–MS (small molecules), UV–Vis (if payload is chromophoric), or SDS-PAGE/SEC for proteins.
Safety and Handling

Item-specific safety (from Product Data)

  • GHS classification, signal word, hazard statements, and pictograms: Not specified for this item; refer to SDS.

General safety considerations for DBCO–PEG–NH2 (literature/practice)

  • Potential hazards: Primary amines may cause skin/eye irritation and respiratory irritation if aerosolized. Aromatic strained alkynes can be harmful if ingested/inhaled and may be light-sensitive.
  • PPE: Wear lab coat, safety glasses or face shield, and appropriate chemically resistant gloves (e.g., nitrile). Use in a fume hood to avoid inhalation of vapors/aerosols.
  • Incompatibilities: Avoid strong oxidizers, strong acids/bases, and azide-containing decontamination solutions that could trigger unintended SPAAC. Copper is not required; avoid copper catalysts if copper-free bioconjugation is intended.
  • First aid (overview; defer to SDS):
    • Skin/eye contact: Rinse with water for ≥15 minutes; remove contaminated clothing. Seek medical attention for persistent irritation.
    • Inhalation: Move to fresh air; seek medical attention if symptoms persist.
    • Ingestion: Rinse mouth; do not induce vomiting; seek medical attention.
  • Spill response: Absorb with inert material, collect in compatible container, and decontaminate surfaces with suitable solvent/detergent. Prevent environmental discharge.
  • Storage notes: Store tightly closed at room temperature per Product Data. General best practice: protect from light and moisture, and keep desiccant in the container.

Authoritative source: Always consult the product-specific SDS for definitive hazard and response information.

Solvent Selection

Applicability

  • This is a bifunctional linker/reagent rather than a bulk solvent. Solvent selection here refers to media for dissolution and for conjugation reactions.

General solvent behavior (literature)

  • Polarity: Amphiphilic. PEG chain confers hydrophilicity; DBCO aromatic system imparts hydrophobic character.
  • Common solvents: High solubility in DMSO, DMF, NMP, dichloromethane (DCM), and acetonitrile. Many variants are moderately to highly soluble in aqueous buffers, especially with longer PEG.
  • Aqueous miscibility: Stock solutions are often prepared at 10–50 mM in anhydrous DMSO or DMF, then diluted into phosphate or HEPES buffers for SPAAC.

Choosing media by use-case (general)

  • Amide coupling (to carboxylates/NHS esters): DMF, DMSO, or DCM with a base (e.g., DIPEA) for small molecules; mixed DMF/buffer systems (pH 7.5–8.5) for biomolecules.
  • SPAAC with azides on biomolecules: Aqueous buffers (PBS, HEPES, or saline) at pH 6.5–8.0; small organic cosolvent (≤10–20% DMF or DMSO) can aid solubility without denaturing proteins.
  • Surface modification: Use anhydrous organic solvents for polymer substrates; buffered aqueous media for hydrophilic surfaces.

Brief comparison (general)

  • DBCO vs BCN/DIBAC: DBCO is typically more hydrophobic but highly reactive; BCN can offer improved aqueous solubility when PEG length is short.
  • Solvent cautions: Avoid amine-reactive solvents/additives (e.g., phosgene derivatives) and azide contaminants that can consume DBCO.
Storage and Reconstitution

Item-specific storage and shipping (from Product Data)

  • Storage conditions: Room temperature.
  • Shipped in: Normal.

General best practices (literature/practice)

  • Light/moisture protection: Store in a tightly sealed, light-resistant container with desiccant to preserve DBCO activity and minimize PEG hygroscopic uptake.
  • Stock solutions: Prepare concentrated stocks (e.g., 10–50 mM) in anhydrous DMSO or DMF for convenience. Aliquot to minimize freeze–thaw and headspace moisture.
  • Aqueous solutions: Prepare fresh before use; the amine can undergo slow degradation and DBCO can be consumed by trace azides over time. Short-term storage at 4 °C is acceptable; avoid sodium azide preservatives.
  • Shelf life: Not specified for this item; refer to CoA/Spec Sheet. Verify activity by a small-scale test click if material has been stored for extended periods.
  • Compatibility: Avoid prolonged exposure to strong acids/bases and oxidants. Do not store in buffers containing primary amines (may react with activated forms) or azides (will consume DBCO).

Reconstitution guidance

  • Warm viscous materials gently to room temperature to facilitate dissolution. Sonication can aid dissolution in DMSO/DMF.
  • Filter sterilization (0.22 µm) is possible for aqueous working solutions if required for biological assays; verify no loss by adsorption to filters for low-concentration work.

Research use note

  • For research use only.
Structure and Identity

Item-specific identifiers (from Product Data)

  • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
  • CAS, CID, InChIKey, SMILES: Not specified for this item; refer to CoA/Spec Sheet.

General structural description (literature)

  • Core motif: DBCO (dibenzocyclooctyne) — a strained cyclooctyne fused to two benzene rings; the ring strain activates the alkyne for copper-free azide–alkyne cycloaddition (SPAAC).
  • Linker: Poly(ethylene glycol) chain (PEGn) providing hydrophilicity, reduced aggregation, and increased aqueous compatibility; PEG length varies by product definition (not specified here).
  • Terminus: Primary amine (–NH2) at the PEG end, enabling amide formation with activated carboxyls (e.g., NHS esters) or other electrophiles.
  • Functional groups: Strained internal alkyne (DBCO), aryl rings (two benzene rings), ether repeats (–CH2–CH2–O–)n in PEG, terminal primary amine.
  • 2D depiction in words: Two fused benzene rings share a cyclooctyne ring bearing an internal alkyne; one benzylic position is tethered to a flexible –(O–CH2–CH2)n– chain that terminates in –NH2.

Stereochemistry (literature)

  • DBCO ring adopts conformations driven by ring strain; no stereocenters are inherent. PEG segment is achiral and conformationally flexible.

Naming notes (literature)

  • Common synonyms: DBCO–PEG–NH2, DBCO-amine linker, dibenzocyclooctyne–PEG–amine. Exact PEG length and counterions (if any) determine formal registries and MW.
Synthetic Utility

Functional group strategy (literature)

  • Dual-function linker: The molecule presents a nucleophilic primary amine and a strained alkyne. This orthogonality enables sequential ligations: first amide coupling (amine→carboxyl), then SPAAC (DBCO→azide), or the reverse when using activated azides.
  • PEG spacer: Controls distance and solubility, reduces steric hindrance in macromolecular or surface settings, and allows fine-tuning of conjugate properties by varying PEG length.

Common transformations

  • Amide coupling: With NHS esters, acid chlorides, anhydrides, or via EDC/NHS activation of carboxylates on biomolecules, polymers, or small molecules.
  • Urethane/thiourea formation: Reaction of the amine with chloroformates/activated carbonates or isothiocyanates to create carbamate/thiourea linkages.
  • SPAAC click: Rapid, selective triazole formation with organic azides on probes, polymers, or biomolecules; no copper catalyst required.

Retrosynthetic planning

  • Use DBCO-PEG-NH2 as a convergent module: install onto one partner through its amine, then connect to an azide-functional counterpart late-stage to minimize protecting group manipulations.

Selectivity and compatibility

  • The DBCO alkyne tolerates water, oxygen, and many functional groups; avoid azide-containing preservatives to prevent premature consumption.
  • The amine may require protection (e.g., Boc) if orthogonal manipulations are planned prior to final conjugation.

Characterization

  • Monitor progress by NMR (aromatic DBCO signals, PEG envelope), LC–MS/MALDI for mass shifts, and chromatographic purity (HPLC/SEC for bioconjugates).
Target Specificity

Not applicable to this product type.

  • This reagent is a chemical linker for SPAAC and amide coupling. It does not possess inherent biological target specificity (no antigen/epitope/clone/isotype). Any selectivity arises solely from the presence of azide partners or accessible carboxyl groups created by the user on their substrate.

¿Quieres que te enviemos un mensaje cuando tengamos descuentos disponibles?

Recordármelo más tarde

¡Gracias! Por favor, revisa tu bandeja de entrada de correo electrónico para confirmar.

¡Vaya! Las notificaciones están desactivadas.