Dehydroascorbic Acid (DHA) Content Assay Kit (Phenanthroline, Micro Method)

Cat. No.: D1521841
Disponible para pedir
CALIDAD & PUREZA BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
★
Talla
USA
Alemania (EU)*
Precio
Cantidad
100T
D1521841-100T
Fabricado bajo pedido · 8–12 semanas
269,90US$
Enter a quantity for the sizes you want to add.

Descripción general

Vitamin C (Vitamin C), also known as L-Ascorbic Acid (AsA), is an essential nutrient for higher primates and a few other organisms. In living organisms, Vitamin C acts as an antioxidant; it is an acidic hexose derivative and a lactone of an enolic hexuronic acid, protecting the body from damage by free radicals. It also functions as a coenzyme. Its widespread dietary sources are various fresh fruits and vegetables. Vitamin C has two isomers, the L-form and the D-form, but only the L-form possesses physiological function. Both the reduced and oxidized forms exhibit physiological activity. The detection principle of this kit is as follows: A reducing agent is used to reduce dehydroascorbic acid to reduced ascorbic acid. Under acidic conditions, the reduced ascorbic acid reduces ferric ions to ferrous ions, which then form a stable red chelate complex with phenanthroline. The absorbance is measured at 534 nm using a microplate reader. Within a certain concentration range (sample concentration controlled between 1-40 μg/ml), the absorbance shows a linear relationship with the ascorbic acid content, allowing for the determination of ascorbic acid concentration. This kit is primarily used for detecting Vitamin C (ascorbic acid) in plant tissues to calculate the total ascorbic acid content. By subtracting the original reduced ascorbic acid content present in the sample, the dehydroascorbic acid content can be obtained. The advantages of this method are: 1. Stable reaction with minimal fading; 2. Simple operation; 3. No interference from reducing sugars or other common reducing substances, ensuring good specificity; 4. High sensitivity. This product is for research use only and is not intended for use in diagnostic procedures.

Especificaciones

Especificaciones y pureza
BioReagent
Grado
BioReagent
Aplicación
Cell Metabolism
Método de detección
Colorimetric Method
Detection instrument
Microplate reader
Detection wavelength
534nm
Almacenamiento y envío
Condiciones de almacenamiento de almacenamiento
Store at 2-8°C,Protected from light
Enviado en
Wet ice
Estabilidad y almacenamiento
Store at 2-8℃ for 6 months. Store in the dark.

Datos avanzados

Certificados (CoA, COO, BSE/TSE y tabla de análisis)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Calculadoras de soluciones
Reseñas

Reseñas de cliente

Application Protocols

Item-specific step-by-step protocols, kit components, and recommended instrument settings are not provided here. Refer to the kit’s instruction booklet for authoritative procedures.

  • General workflow outline (literature-level guidance for phenanthroline micro DHA assays):

    1. Prepare standards and samples in the recommended assay buffer; protect from light.
    2. If required, perform selective pretreatment to distinguish ascorbate and DHA (e.g., convert DHA to ascorbate or vice versa) according to the method principle.
    3. Add phenanthroline/iron reagent(s) in micro volumes; mix thoroughly.
    4. Incubate at ambient temperature until color stabilizes.
    5. Measure absorbance at ~510 nm using a microplate reader or spectrophotometer.
    6. Subtract appropriate blanks; construct a standard curve and compute DHA concentrations, applying dilution factors.
  • Tested applications, recommended dilutions, and positive controls (item-specific): Not specified for this item; refer to the kit protocol and CoA.

Biological Roles

This section describes the biology of the target analyte (DHA) in general terms; it is not a claim about this product’s medical use.

  • Dehydroascorbic acid (literature):

    • DHA is the oxidized form of L-ascorbic acid (vitamin C), interconverting through redox cycling in cells and extracellular fluids.
    • Ascorbate functions as a key antioxidant and enzymatic cofactor; DHA can be taken up by cells via GLUT transporters and reduced back to ascorbate by intracellular reductants (e.g., glutathione-dependent systems, thioredoxin).
    • The ascorbate/DHA ratio is a marker of oxidative status in biological and food systems.
    • DHA is chemically less stable than ascorbate, prone to hydrolysis to 2,3-diketogulonic acid, especially at neutral–alkaline pH and elevated temperatures.
  • Analytical implications (literature):

    • Sample handling conditions (light, oxygen, pH, metals) strongly influence the measured DHA fraction.
    • Selective derivatization or enzymatic conversion steps are often employed to distinguish ascorbate from DHA in total vitamin C analyses.

This kit is intended for research use only to quantify DHA content; it is not intended for diagnostic or therapeutic purposes.

Buffer Applications

This product is not a general-purpose buffer; it is an assay kit with its own optimized reagent system. Buffer formulation details and pH ranges, if provided, are specific to the kit and should be followed exactly.

  • Item-specific buffer details: Not specified for this item; refer to the kit protocol.

  • Practical guidance (general):

    • Use the supplied or recommended assay buffer to ensure correct complexation and redox behavior.
    • If sample pretreatment requires deproteinization or pH adjustment, re-equilibrate samples to the kit’s working buffer before measurement to minimize matrix effects.
Green Alternatives
  • Greenness of the method (general):

    • Phenanthroline micro methods operate in aqueous media with small reaction volumes, reducing solvent waste compared to macro cuvette assays.
    • Visible-range detection (~510 nm) uses standard spectrophotometers or microplate readers—no hazardous derivatization reagents like DNPH are strictly required for DHA determination.
  • Comparison to alternative assays (literature):

    • DNPH-based carbonyl assays: Often involve strong acids and organic solvents; higher hazard and waste footprints.
    • HPLC-UV/ED for vitamin C/DHA: Higher solvent consumption and energy usage; improved selectivity but more resource intensive.
    • Iodometric titration: Minimal reagents but low selectivity and poor micro-scale compatibility.
  • Practical green tips:

    • Use microplate formats to minimize reagent volumes and waste.
    • Segregate metal–ligand waste for proper disposal; avoid unnecessary organic cosolvents.
    • Validate minimal sample pretreatment steps that still meet accuracy requirements to reduce chemicals and time.
  • Trade-offs:

    • Phenanthroline methods can be susceptible to matrix redox interferents; extra cleanup steps (which may add waste) can be needed in complex samples. Selectivity vs. greenness should be balanced per application.
Pharmaceutical Uses

No therapeutic or clinical claims are made for this product. It is for research use only.

  • Relevant non-clinical uses (general, analytical context):

    • Quality-control testing and R&D characterization of DHA/ascorbate content and redox balance in nutritional formulations, excipient systems, and stability studies.
    • Comparative method development alongside HPLC or electrochemical detection methods to establish orthogonal confirmation of vitamin C redox species.
  • Compendial status:

    • Any pharmacopeial monographs or acceptance criteria for vitamin C/DHA are outside the scope of this kit’s specification. Item-specific conformity: Not specified for this item; refer to CoA/Spec Sheet and internal method validation.
  • Formulation role:

    • Not an excipient or API; it is an analytical reagent kit designed to measure DHA in research and development settings.
Physical Properties

As an assay kit containing multiple reagents, conventional single-compound physical constants are not applicable item-wide.

  • Item-specific physical specifications:

    • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
    • Density, melting/boiling point, refractive index, UV cutoff, pKa, logP: Not specified for this item; refer to CoA/Spec Sheet.
  • Operational optical readout (literature, for phenanthroline assays):

    • Typical detection wavelength: ~510 nm (orange-red Fe(II)–phenanthroline complex).
    • Pathlength: compatible with microplate (micro method) or short-path cuvettes.
  • Solubility context (general):

    • Reagents in such kits are commonly aqueous buffers and ligand/metal solutions formulated for immediate dilution/use. Specific solvent composition and concentrations are not provided here; refer to the kit booklet/CoA for exact details.

Note: Where precise numerical specifications are required for method validation or regulatory documentation, consult the Certificate of Analysis (CoA) and the kit’s detailed protocol sheet.

Quality and Grades
  • Item grade (specific to this product):

    • BioReagent grade: indicates reagents suitable for biochemical workflows, emphasizing controlled impurity profiles, low background in spectrophotometric assays, and lot-to-lot consistency.
  • What BioReagent grade means in practice:

    • Low baseline absorbance in the visible range to maximize signal-to-noise at the phenanthroline detection wavelength.
    • Buffered components formulated for reproducibility in micro-volume formats.
    • Trace-metal content and redox activity of components are typically controlled to minimize blank drift (specific limits: Not specified for this item; refer to CoA/Spec Sheet).
  • Lot release and documentation:

    • Each lot should be accompanied by a Certificate of Analysis (CoA) detailing acceptance criteria relevant to performance (e.g., calibration linearity, blank absorbance range). Exact criteria: Not specified for this item; refer to CoA/Spec Sheet.
  • Stabilizers and preservatives:

    • If present, stabilizers/preservatives and their concentrations are reported in the kit documentation. Item-specific stabilizer details: Not specified for this item; refer to CoA/Spec Sheet.
  • Suitability notes:

    • Designed for research use only (as stated). Not for diagnostic procedures or clinical decision-making.
Reaction and Applications
  • Primary application (item-specific):

    • Quantitative determination of dehydroascorbic acid (DHA) content in research samples using a phenanthroline-based micro method. Suitable for laboratories assessing vitamin C redox status, food/nutrition research materials, plant extracts, and biochemical preparations.
  • Assay principle (literature overview of phenanthroline micro method):

    • DHA is quantified via its redox coupling to the Fe(III)/Fe(II) system; ascorbate (or a DHA-derived equivalent after selective conversion) reduces Fe(III) to Fe(II), which forms a stable orange-red tris(1,10-phenanthroline) complex measurable at ~510 nm. Differential measurement strategies allow selective DHA quantification versus total vitamin C. Exact reagent identities and sequences in this kit are not specified here; refer to the kit protocol.
  • Practical tips (general):

    • Calibrate with a fresh standard curve prepared in the same matrix/buffer as samples.
    • Protect standards and samples from light; minimize air exposure to limit further oxidation/reduction during handling.
    • Use microplates or microcuvettes with known optical pathlength; correct for pathlength if comparing across formats.
    • Include matrix blanks and spike-recovery controls to assess interference.
  • Typical performance characteristics (literature):

    • Linear range commonly spans low µM to sub-mM in micro methods; LOD/LOQ depend on kit formulation and optics. Item-specific performance: Not specified for this item; refer to CoA/Spec Sheet.
Reaction Conditions

Because this is an assay kit, “reaction conditions” refer to analytical reaction/setup conditions rather than synthetic transformations.

  • Item-specific conditions: Not specified for this item; refer to the kit protocol for reagent volumes, incubation times, and temperatures.

  • General literature guidance for phenanthroline micro assays:

    • Temperature: Ambient (20–25°C) is commonly used for color development; maintain consistent temperature for reproducibility.
    • pH: Mildly acidic buffers (e.g., acetate) are frequently employed to stabilize Fe(II)–phenanthroline complexes and control redox chemistry.
    • Incubation: Color typically develops within minutes to tens of minutes; monitor kinetics to identify the plateau before reading at ~510 nm.
    • Interferences: Chelators (EDTA), strong oxidants/reductants, and colored species overlapping 480–540 nm can bias results; include blanks/spikes.
    • Calibration: Prepare a fresh standard curve in the same buffer/matrix as samples; verify linearity over the expected concentration range.

These parameters are provided as general background. Follow the detailed instructions packaged with the kit for validated conditions.

Safety and Handling
  • GHS information (item-specific):

    • Signal word: Not specified for this item; refer to SDS.
    • H-statements: Not specified for this item; refer to SDS.
    • Pictograms: Not specified for this item; refer to SDS.
    • GHS classification: Not specified for this item; refer to SDS.
  • Storage and shipping (item-specific):

    • Storage: Store at 2–8°C, protected from light.
    • Shipping: Shipped on wet ice.
  • General laboratory precautions (best practice):

    • Wear appropriate PPE: lab coat, safety glasses, and nitrile gloves.
    • Avoid ingestion, inhalation, and skin/eye contact; handle solutions in a well-ventilated area.
    • Protect all light-sensitive reagents and standards from ambient light to prevent photodegradation of redox-active components.
    • Avoid contamination between reagents; use calibrated pipettes and clean plastics/glassware.
  • Chemical compatibility and stability (general guidance):

    • Redox-active matrices (e.g., strong reducing agents, transition metals) and high pH may interfere with DHA/Fe–phenanthroline chemistry; process such samples with appropriate controls.
    • Dispose of waste according to institutional and local regulations; chelated metal solutions and dye-containing waste may require specific disposal streams.

Always consult the Safety Data Sheet (SDS) included with the kit for authoritative hazard, first-aid, spill response, and disposal information.

Solvent Selection

This is an aqueous colorimetric assay kit; conventional solvent-selection guidance for synthetic reactions is not directly applicable. However, matrix and diluent choice affect data quality.

  • Polarity and medium (general, literature):

    • Phenanthroline–iron complex formation and DHA redox chemistry proceed efficiently in water-based buffers (commonly acetate, phosphate, or similar). Organic cosolvents (>10–20%) can alter equilibrium and molar absorptivity; minimize unless validated.
  • Miscibility and sample matrices:

    • Compatible with most aqueous sample types. If samples originate from organic extracts (e.g., food, plant matrices), evaporate organic solvent and reconstitute in the recommended assay buffer to avoid spectral and redox interferences.
  • When to choose alternative media:

    • High-fat, protein-rich, or strongly colored matrices may require deproteinization or clarification (e.g., precipitation with acids or organic solvents followed by removal and neutralization). Specific procedures: Not specified for this item; refer to kit protocol.
  • Comparison (literature context):

    • Aqueous phenanthroline assays are favored over strongly acidic/organic DNPH-based carbonyl assays when targeting DHA with a visible detection window and micro-volume compatibility.
Storage and Reconstitution
  • Storage (item-specific):

    • Store at 2–8°C, protected from light.
    • Shipped on wet ice to maintain integrity during transit.
  • Stability and shelf life:

    • Item-specific shelf life and post-opening stability: Not specified for this item; refer to CoA/Spec Sheet.
  • Reconstitution and preparation:

    • Some kit components may require dilution or reconstitution prior to use. Exact solvents, volumes, and order of mixing: Not specified for this item; refer to the kit protocol.
    • Allow refrigerated components to equilibrate to room temperature before use to avoid condensation and ensure accurate pipetting.
    • Keep light-sensitive reagents in amber containers or foil-wrapped during handling.
  • Handling notes:

    • Use clean, dry, labeled microtubes or reservoirs; avoid cross-contamination by dedicating tips to each reagent.
    • Return unused reagents to 2–8°C promptly after use.

For detailed stability claims, freeze–thaw guidance (if applicable), and component-specific storage after opening, consult the product’s instruction manual and CoA.

Structure and Identity

This product is an analytical kit designed to quantify dehydroascorbic acid (DHA) using a phenanthroline-based micro-scale colorimetric method. It is not a single, pure compound; rather, it comprises multiple reagents optimized for DHA determination.

  • Item identity (kit):

    • Product: Dehydroascorbic Acid (DHA) Content Assay Kit (Phenanthroline, Micro Method)
    • SKU: D1521841
    • Intended analyte: Dehydroascorbic acid (oxidized vitamin C)
    • Assay chemistry: 1,10-phenanthroline colorimetry in micro-format
    • Grade: BioReagent
  • Item-specific identifiers:

    • CAS: Not specified for this item; refer to CoA/Spec Sheet.
    • CID: Not specified for this item; refer to CoA/Spec Sheet.
    • InChIKey: Not specified for this item; refer to CoA/Spec Sheet.
    • SMILES: Not specified for this item; refer to CoA/Spec Sheet.
    • Molecular formula / weight: Not specified for this item; refer to CoA/Spec Sheet.
  • General structural context (literature):

    • Target analyte (DHA) is the oxidized dicarbonyl form of L-ascorbic acid; it possesses a 1,2-diketo-lactone framework in equilibrium with hydrated forms.
    • Reporter ligand 1,10-phenanthroline is a planar, bidentate N,N-chelating heteroaromatic that forms intensely colored complexes with Fe(II) (orange-red), enabling microplate or cuvette detection.
  • 2D description in words (literature):

    • DHA: a five-membered lactone ring with enediol-oxidized to diketone functionality; no stereocenters persist in the oxidized form.
    • 1,10-Phenanthroline: three fused aromatic rings with nitrogens at the 1 and 10 positions (ortho-diimine).
Synthetic Utility

Not typically applicable. This product is an analytical assay kit rather than a chemical building block or reagent for preparative synthesis.

  • If your workflow involves synthetic samples containing DHA or ascorbate derivatives, use this kit downstream for analytical quantification rather than as a reagent in the synthesis itself.
Target Specificity
  • Intended analyte (specific): Dehydroascorbic acid (DHA), the oxidized form of vitamin C.

  • Selectivity concept (general, literature):

    • Phenanthroline colorimetry detects Fe(II)–phenanthroline complex formation resulting from redox reactions linked to DHA/ascorbate. Selective measurement of DHA typically requires differential treatment (e.g., separate determinations of total vitamin C vs. ascorbate-only, with DHA calculated by difference). Exact selectivity strategy in this kit: Not specified for this item; refer to the kit protocol.
  • Cross-reactivity and interferences:

    • Potential interferents include reductants (e.g., sulfite, dithiothreitol), transition metals, and strongly colored compounds absorbing near 510 nm. Matrix-matched controls are recommended.

Preguntas frecuentes

How is this product shipped?
This product ships chilled on wet ice. Unpack on arrival and transfer it to the storage condition stated above.

¿Necesita ayuda para elegir la calidad?

Nuestra guía de selección de calidades cubre la pureza, el estado del estabilizador y la idoneidad de la aplicación para todas las variantes de nuestro catálogo.

Ver la guía de calidades BioReagent →

¿Quieres que te enviemos un mensaje cuando tengamos descuentos disponibles?

Recordármelo más tarde

¡Gracias! Por favor, revisa tu bandeja de entrada de correo electrónico para confirmar.

¡Vaya! Las notificaciones están desactivadas.