Bio FIREFLYGLO luciferase reporter gene detection kit

Cat. No.: G1375755
Disponible para pedir
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. for Chemiluminescence ? Chemiluminescence grade — purity controlled to avoid quenching/background light. Use in chemiluminescent assays where signal fidelity is critical.
 ·  off list, applied to all prices below.
Size
Estado
Price
Qty
10ml
G1375755-10ml
1-2 wks(?)
Item is derived from our semi-finished stock and is processed in 1-2 weeks.
189,90US$
100ml
G1375755-100ml
1-2 wks(?)
Item is derived from our semi-finished stock and is processed in 1-2 weeks.
1.049,90US$
Enter a quantity for the sizes you want to add.
🧪

Why this grade

BioReagent, for chemiluminescence BioReagent,for Chemiluminescence for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Protected from light,Store at -20°C Ships Ice chest + Ice pads Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Descripción general

Firefly Luciferase Reporter Gene Assay Kit (Glow) is a glow-type quantitative detection kit characterized by high sensitivity and stable luminescent signals. It is suitable for high-throughput detection of firefly luciferase expression in mammalian cells. This product significantly enhances luminescent signal intensity, effectively improving detection sensitivity. It can be used to detect firefly luciferase reporter gene expression in ADCC Reporter Bioassays or cells.

G1375755
Component
10 mL100 mL
Storage
G1375755A
Firefly Luciferase Reaction Buffer (Glow)
10 mL
100 mL
-20℃. Store in the dark.
G1375755B
Firefly Luciferase Substrate (Glow)
1 vial
1 vial
-20℃. Store in the dark.

he main features and differences among three One-Step Firefly Luciferase Reporter Gene Assay Kits from Aladdin are as follows:

For high luminescent signal requirements and detection within 30 minutes: Recommended:  Firefly Luciferase Reporter Gene Assay Kit (Glow Bright) (Cat. No. B1375760)

For both luminescent signal and stability requirements, suitable for batch or continuous operation: Recommended: Firefly Luciferase Reporter Gene Assay Kit  (Cat. No. F773892)

For standard luminescent signal requirements: Recommended:  Firefly Luciferase Reporter Gene Assay Kit (Glow) (Cat. No. G1375755)

For routine laboratory detection, the  Firefly Luciferase Reporter Gene Assay Kit (Glow Bright) (Cat. No. B1375760) is the recommended priority.

Product Cat. No.
Product Name
Luminescence Type
Signal Intensity
Sensitivity
Half-Life
Packaging
Suitable for Batch Samples
Optimal Use After Mixing & Storing at -20°C
F773892Firefly Luciferase Reporter Gene Assay Kit
Glow
Relatively High
Relatively Sensitive
Up to 2h
1 bottle Buffer
1 vial Substrate
Very Suitable
1 Month
G1375755
Firefly Luciferase Reporter Gene Assay Kit (Glow)
Glow
High
Sensitive
25-30min1 bottle Buffer
1 vial Substrate
Very Suitable
1 Week
B1375760
Firefly Luciferase Reporter Gene Assay Kit (Glow Bright)
Glow
Very High
Highly Sensitive
25-30min
1 bottle Buffer
1 vial Substrate
Very Suitable
1 Week

Instructions for Use:

1. User-Supplied Materials

  • PBS

  • Multichannel pipette

  • White or black opaque cell culture microplate

  • Luminometer or microplate reader equipped with a luminescence detection module.

2. Preparation Before Assay
(1) Initial Reconstitution: Upon first use, transfer the entire contents of the Firefly Luciferase Reaction Buffer (Glow) bottle into the Firefly Luciferase Substrate (Glow) vial. Mix thoroughly until the substrate is completely dissolved. Aliquot the reconstituted detection reagent as needed. For long-term storage, aliquot and store at -70°C. For short-term storage, store aliquots at -20°C for no longer than one month. Use reconstituted reagent promptly.
(2) Pre-assay: Before each experiment, equilibrate the aliquoted, frozen detection reagent to room temperature.

3. Procedure
(1) Equilibrate Plates: Remove the cell culture plate from the incubator and allow it to stand at room temperature for 5-15 minutes.
Note: Use white or black opaque cell culture plates to minimize signal interference between wells.
(2) Add Detection Reagent: Using a multichannel pipette, add the equilibrated Firefly Luciferase Reaction Buffer (Glow) containing the substrate to each cell culture well. The volume added should be equal to the volume of the culture medium in the well. For example:
* 96-well plate: Typically add 80-100 µL culture medium; add 80-100 µL detection reagent.
* 384-well plate: Typically add 20-30 µL culture medium; add 20-30 µL detection reagent.
(3) Mix to Lyse Cells: To ensure complete cell lysis, place the plate on an orbital shaker or an instrument with shaking capability. Shake at medium to high speed at room temperature for 5 minutes.
Note: A shaking time of 5 minutes is recommended. This can be adjusted based on cell density to ensure complete lysis and stable luminescent results.
(4) Detection: Following the shaking step, immediately measure firefly luciferase reporter gene activity using a luminometer or microplate reader.
Note: For optimal results, perform the detection as soon as possible after adding the detection reagent.

Precautions

  1. Instrument Selection: Any instrument capable of detecting chemiluminescence is suitable for use with this kit. However, background signal levels and measured values for identical samples may vary between different detectors. Values obtained from different instruments for the same sample are not directly comparable. To prevent well-to-well interference, the use of opaque white or black cell culture plates is strongly recommended.

  2. Consistent Conditions: Luminescent signals can be influenced by environmental factors such as medium components and temperature. Ensure consistent detection conditions across all samples within an experiment.

  3. Temperature Sensitivity: The enzymatic reaction is temperature-sensitive. It is essential to equilibrate both the detection reagent and the cell culture plate to room temperature before adding the reagent and performing the assay.

  4. Reagent Stability: To maintain the stability of the luciferase assay reagent, aliquot it appropriately after reconstitution. For long-term storage, store aliquots at -70°C protected from light. For short-term storage, store at -20°C for no longer than one month. Use aliquots promptly and avoid repeated freeze-thaw cycles.

  5. Multiple Plate Assay: If detecting multiple cell culture plates simultaneously, strive to maintain consistent incubation time after adding the detection reagent to each plate before reading. This ensures optimal and comparable results across plates.

  6. Emission Wavelength: The bioluminescence catalyzed by firefly luciferase exhibits a peak emission wavelength of 560 nm.

Almacenamiento y envío
Condiciones de almacenamiento de almacenamiento
Protected from light,Store at -20°C
Enviado en
Ice chest + Ice pads
Estabilidad y almacenamiento
Store at -20°C long term (12 months). Store in the dark. After reconstitution, the Firefly Luciferase Substrate (Glow) can be stored at -70℃ for 12 months, or at -20℃ for up to 1 month. Store in the dark.
Imágenes
Firefly Luciferase Reporter Gene Assay Kit (Glow) (G1375755) -Performance on serially diluted HEK293 cells (50 to 200,000)
The detection performance of this product on serially diluted HEK293 cells stably transfected with the firefly luciferase gene. The data shown in the figure were generated from a 100 μL cell culture sample mixed with 100 μL of detection reagent, followed by incubation on a shaker for 5 minutes. Actual measured data may vary depending on the detection instrument and other factors. Additionally, the maximum detectable cell number can vary considerably with cell type and the intrinsic level of luciferase expression.

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificados (CoA, COO, BSE/TSE y tabla de análisis)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate TypeFechaArticulo
ZJ25F0926937Certificate of AnalysisJul 14, 2026 G1375755
Preguntas frecuentes y artículos
Calculadoras de soluciones
Reseñas

Reseñas de cliente

Need help choosing the grade?

Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.

View BioReagent grade guide → View for Chemiluminescence grade guide →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.