Human CD3+T Cell Sorting Kit (Negative Selection)

Cat. No.: H1522404
Disponible para pedir
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
Size
USA
Alemania (EU)*
Price
Qty
10T
H1522404-10T
Fabricado bajo pedido en EE. UU. · 2–4 semanas ·
209,90US$
50T
H1522404-50T
Fabricado bajo pedido · 8–12 semanas
929,90US$
100T
H1522404-100T
Fabricado bajo pedido · 8–12 semanas
1.499,90US$
Enter a quantity for the sizes you want to add.
🧪

Why this grade

BioReagent BioReagent for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Store at 2-8°C,Do not freeze Ships Wet ice,Do not freeze Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Descripción general

The Human CD3⁺ T Cell Isolation Kit (Negative Isolation) is used to isolate CD3⁺ T cells from human peripheral blood mononuclear cells (PBMCs) by negative i solation. The principle is to use a cocktail of biotin-labeled monoclonal antibodies against non-target cells (non-CD3⁺ T cells), followed by removal of these non-target cells using streptavidin-labeled magnetic beads, thereby achieving the isolation of human peripheral blood CD3⁺ T cells. A magnetic separator is required for the isolation process.

Applications

Isolation of CD3⁺ T cells from human PBMCs.

H1522404
Component
Appearance
10T
50T
100T
Storage
H1522404A
Biotin-Antibody Mix
Liquid20 μL
100 μL
200 μL
2-8℃.
H1522404B
Streptavidin Magnetic Beads
Liquid
200 μL
1 mL
1 mL×2
2-8℃.

Protocol Example

  1. Prepare human PBMCs

    Isolate PBMCs from human peripheral blood using Ficoll density gradient centrifugation. Collect the PBMCs, wash the cells with PBS, and after centrifugation, resuspend the PBMCs in Isolation Buffer to a density of 1×10⁸ cells/mL.

    Note: Isolation buffer is PBS containing 2 mM EDTA and 2% fetal bovine serum (FBS), or PBS containing 2 mM EDTA and 0.5% BSA. The buffer must be pre-filtered through a 0.22 μm filter.

  2. Add Biotin-Antibody Mix

    Add 100 μL of cell suspension (1×10⁷ cells) to the bottom of a sterile FACS tube, then add 2 μL of Biotin-Antibody Mix. Mix well and incubate at 4°C for 10 min.

    Note: Add the cell suspension directly to the bottom of the FACS tube, avoiding the tube wall. Depending on the magnetic separator used, a centrifuge tube can also be used for cell isolation. If isolating more cells, increase the volume of Biotin-Antibody Mix proportionally.

  3. Add Streptavidin Magnetic Beads

    After incubation, add 20 μL of washed Streptavidin Magnetic Beads to the FACS tube, mix well, and incubate at 4°C for 10 min (the beads must be washed before use: vortex thoroughly to resuspend the beads, transfer the required volume of beads to a 1.5 mL centrifuge tube, add Isolation Buffer to a total volume of 1 mL, centrifuge at 10,000 g for 1 min or use a magnetic separator for 3 min, then discard the supernatant. Add 1 mL of Isolation Buffer and wash the beads once more, then resuspend the beads in the same volume of Isolation Buffer as originally taken. For example, if 20 μL of beads are taken, resuspend them in 20 μL of Isolation Buffer after washing).

    Note: If isolating more cells, increase the volume of Streptavidin Magnetic Beads proportionally. For example, to isolate 5×10⁷ cells, add 10 μL of Biotin-Antibody Mix and 100 μL of Streptavidin Magnetic Beads to 500 μL of cell suspension. If isolating fewer than 1×10⁷ cells, adjust the cell suspension volume to 100 μL, then add 2 μL of Biotin-Antibody Mix and 20 μL of Streptavidin Magnetic Beads.

  4. Dilute and mix

    After incubation, add 2.5 mL of Isolation Buffer to the FACS tube, and mix by pipetting 5 times (avoid vigorous shaking or inverting).

  5. Magnetic separation

    Place the FACS tube containing the cell suspension on a magnetic separator and let stand for 5 min.

  6. Collect CD3⁺ T cells

    Gently pour the cell suspension into a sterile centrifuge tube (do not remove the FACS tube from the magnetic separator while pouring). This cell suspension contains the purified human CD3⁺ T cells. Centrifuge at 300 g for 5 min, then discard the supernatant and collect the cells.

  7. Resuspend for further use

    Wash the cells as required for your experiment, then resuspend them in the desired buffer or culture medium for subsequent molecular or cell biology experiments.

Isolation Performance

CD3⁺ T cells were isolated from human PBMCs. Cells before and after isolation were stained with PE-labeled anti-human CD3 antibody (clone OKT3) and analyzed by flow cytometry. The purity of CD3⁺ T cells before and after isolation was 69.1% and 97.9%, respectively.

Precautions

  1. Avoid freezing the magnetic beads and antibody mix during use and storage.

  2. Low-retention pipette tips and centrifuge tubes are recommended to avoid loss of beads and antibodies due to adsorption.

  3. This product must be used with a magnetic separator.

  4. For research use only.

Almacenamiento y envío
Condiciones de almacenamiento de almacenamiento
Store at 2-8°C,Do not freeze
Enviado en
Wet ice,Do not freeze
Estabilidad y almacenamiento
Store at 2-8℃ long term (12 months). Do not freeze.
Contents & Storage
H1522404
Component
Appearance
10T
50T
100T
Storage
H1522404A
Biotin-Antibody Mix
Liquid20 μL
100 μL
200 μL
2-8℃.
H1522404B
Streptavidin Magnetic Beads
Liquid
200 μL
1 mL
1 mL×2
2-8℃.

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificados (CoA, COO, BSE/TSE y tabla de análisis)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate TypeFechaArticulo
ZJ26F0636353Certificate of AnalysisJun 11, 2026 H1522404
Preguntas frecuentes y artículos
Calculadoras de soluciones
Reseñas

Reseñas de cliente

Need help choosing the grade?

Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.

View BioReagent grade guide →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.