GRADE & PURITYRecombinant?Recombinant — produced via recombinant expression for defined sequence and consistency. Use for reproducible, animal-free proteins of known origin.Validated?Validated grade — performance confirmed in defined applications before release. Use when you want documented assurance the reagent works as stated.ExactAb™?ExactAb™ — Aladdin's antibody line emphasizing precision and validated quality. Use for reliable, specificity-validated antibody applications.1 μL/test
Cell adhesion molecule which is required for leukocyte transendothelial migration (TEM) under most inflammatory conditions.
Tyr-690 plays a critical role in TEM and is required for efficient trafficking of PECAM1 to and from the lateral border recycling
Especies hospedadoras
Mouse
Especificidad
CD31
Inmunógeno
Human CD31
Control positivo
Flow Cytometry: Human peripheral blood lymphocytes
Conjugación
PerCP-Cy5.5
Excitación (nm)
Blue Laser(488nm)
Emisión (nm)
690nm
Ex/Em(nm)
Ex:482nm;Em:690nm
Grado
ExactAb™, Recombinant, Validated
Tipo de cadena ligera
kappa
Método de purificación
Protein A purified
Concentración
1 μL/test
Almacenamiento y envío
Condiciones de almacenamiento de almacenamiento
Store at 2-8°C,Protected from light,Do not freeze
Enviado en
Wet ice,Do not freeze
Estabilidad y almacenamiento
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Flow cytometry analysis of CD31 expression by human peripheral blood monocytes (red) compared to an isotype control (blue). Cells were preincubated with Human Fc Receptor Blocking Solution (H1374078). The cells were then stained with Recombinant CD31 Antibody (PerCP-Cy5.5) (Ab232000) at 1μL/test for 1 hour at 4°C. Blue - Mouse IgG (PerCP-Cy5.5) (Ab190081). Black - Unlabelled control, cells without incubation with primary antibody.
Flow cytometry analysis of CD31 expression by human peripheral blood cells (right panel) compared to an isotype control (left panel). Cells were preincubated with Human Fc Receptor Blocking Solution (H1374078). The cells were then stained with Recombinant CD31 Antibody (PerCP-Cy5.5) (Ab232000) at 1μL/test for 1 hour at 4°C. Left panel - Mouse IgG (PerCP-Cy5.5) (Ab190081).
Aplicación
Aplicación
Dilution info
Flow Cytometry
1μl/Test
For flow cytometric staining, the suggested use of this reagent is 1 µL per million cells in 100 µL staining volume or 1 µL per 100 µL of whole blood.
Documentation
📋 Safety Data Sheet (SDS)
Comprehensive hazard, handling, storage, and regulatory compliance document.
We use cookies to ensure the website functions properly and, where permitted, to improve your experience. You can manage your preferences at any time in Settings. Learn more in our Cookie Policy.
Shall we send you a message when we have discounts available?
Remind me later
Thank you! Please check your email inbox to confirm.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.