SP Cation Exchange Rigid Agarose - BioReagent, 70% v/v; 75 μm

Cat. No.: S1523862
Disponible para pedir
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. 70% v/v; 75 μm
Storage
Store at 2-8°C,Do not freeze
Shipped In
Wet ice
Application
Protein purification
 ·  off list, applied to all prices below.
Size
Estado
Price
Qty
25ml
S1523862-25ml
8-12 wks(?) Production requires sourcing of materials. We appreciate your patience and understanding.
99,90US$
100ml
S1523862-100ml
8-12 wks(?) Production requires sourcing of materials. We appreciate your patience and understanding.
319,90US$
Enter a quantity for the sizes you want to add.
🧪

Why this grade

BioReagent, 70% v/v; 75 μm BioReagent for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Store at 2-8°C,Do not freeze Ships Wet ice Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Descripción general

Ion Exchange Chromatography (IEC) is a chromatographic separation method that uses ion exchange ligands as the stationary phase, and separates components based on the difference in binding affinity during the reversible exchange between component ions in the mobile phase and counterions on the stationary phase. With high resolution, large working capacity and easy operation, IEC has now become one of the most widely used purification technologies for the separation and purification of biochemical products, proteins, polypeptides and other substances.Ion exchange chromatography media are mainly composed of three parts: a crosslinked network skeleton (i.e., the matrix structure); functional groups immobilized on the skeleton; and mobile counterions with opposite charge to the functional groups, which are movable and capable of ion exchange.

SP Cation Exchange Rigid Agarose is based on high-rigidity agarose microspheres with an average particle size of 75 μm, and is prepared through chemical modification and functionalization. It has superior mechanical properties, exhibits high dynamic binding capacity under high flow rate conditions, and can process large-volume samples in a short time.

This product features high rigidity, high flow rate tolerance, high pressure resistance and low back pressure. It is commonly used in the capture and intermediate purification stages of biomolecules, and is suitable for easy scale-up to large-scale production.

Aladdin SP Cation Exchange Rigid Agarose is stored in 20% ethanol containing 0.2 M sodium acetate, with a volume ratio of gel to storage solution of 7:3. The product specification of our company refers to the actual volume of the gel.

Table 1 Product Specifications of SP Cation Exchange Rigid Agarose

Parameter

Specification

Matrix

High-rigidity Agarose

Ligand

Sulfopropyl

Mean particle size

75 μm

Ion Capacity

130-160 μmol H<sup>+</sup>/mL medium

Recommended Flow Rate

<600 cm/h

Recommended Pressure

<0.5 MPa (5 bar)

Working pH Range ①

4-13

pH Stability

4-13 (Long-term) 3-14 (Short-term)②

Chemical Stability

Stable in common buffers, such as 1 M NaCl, 1 M NaOH, 6 M guanidine hydrochloride, 8 M urea, 70% ethanol, 30% isopropanol, etc.

Storage

20% ethanol containing 0.2 M sodium acetate, 2~8℃

Shelf Life

5 years

Notes: 

① Working pH range: the pH range within which the separation and purification function can be achieved under the premise of stable chromatography medium.

② Long-term pH range: the pH range within which the medium remains stable for a long time without adverse effects on its subsequent performance. Short-term pH range: the empirically determined pH range for medium regeneration, cleaning in place and sanitization.

Instructions for Use

1. Column Packing

1.1 Preparation of Packing Buffer

Purified water, subjected to ultrasonic degassing for 15 minutes.

1.2 Preparation of Chromatography Medium

Calculate the required amount of chromatography medium (compression factor is approximately 1.15), weigh and set aside. Perform buffer exchange into the packing buffer using a vacuum filter flask. Add a certain amount of packing buffer to the exchanged medium to prepare a slurry with a concentration of approximately 50%.

1.3 Preparation of Chromatography Column

Inspect the chromatography column to ensure all components are intact and clean. Install the bottom column end fitting, tighten the O-ring, then vertically fix the chromatography column on an iron stand. Check and adjust the column with a spirit level to ensure it is perfectly vertical. Draw the packing buffer into a syringe, connect it to the outlet at the bottom of the column, slowly push out the liquid in the syringe to remove air bubbles from the bottom frit. Remove the syringe and screw on the end cap. Add packing buffer to the column to a height of approximately 2 cm.

1.4 Column Packing (taking a chromatography column with 16 mm inner diameter and 10 cm bed height as an example)

Mix the slurry thoroughly, and slowly pour it into the chromatography column guided by a glass rod. If there is a gap between the liquid level and the top of the column, fill it with packing buffer. Connect the flow adapter to the chromatography system, start the pump at a certain flow rate to remove air bubbles from the tubing and the top frit, then pause. Place the flow adapter into the column at a 45° angle, fix it in place and tighten the seal ring, taking care to avoid air bubbles entering. Unscrew the end cap at the bottom of the chromatography column, place the bottom tubing into the waste container, set the flow rate to 60 cm/h. After the medium interface remains unchanged, set the flow rate to 600 cm/h and maintain this flow rate for 45 minutes. Mark the interface with a marker pen and pause the system. Screw on the bottom end cap, disconnect the upper end of the column from the pump, slightly loosen the seal ring on the flow adapter, press the column end fitting to 2 mm below the gel surface, and tighten the seal ring. Connect the top and bottom tubing of the chromatography column to the chromatography system for column efficiency test.

2. Column Efficiency Test

After column packing is completed and before use, the packing quality of the chromatography column can be confirmed through column efficiency measurement and evaluation. Column efficiency is usually evaluated by the Height Equivalent to a Theoretical Plate (HETP) and the Asymmetry factor (As). Acetone or NaCl can be used as the sample for column efficiency measurement, and the sample solution and mobile phase are prepared according to the following table.

Table 2 Solution Preparation for Column Efficiency Test

Test SampleSample Solution PreparationMobile Phase PreparationDetection Method
Acetone0.1% (v/v) acetone in purified waterPurified waterUV detection at 280 nm
NaCl0.8 M NaCl in purified waterPurified waterConductivity detection

Calculate the Height Equivalent to a Theoretical Plate (HETP), number of theoretical plates (N) and Asymmetry factor (As) according to the UV or conductivity curve, using the following formulas: HETP = L / N 

N = 5.54 × (VR / Wh )2

As = a / b

Where: L is the column height; VR is the retention volume; Wh is the peak width at half height; a is the first half peak width at 10% of the peak height; b is the second half peak width at 10% of the peak height.

In general, the HETP value should be less than three times the average particle size of the packing material (i.e., HETP/D50 < 3, where D50 is the average particle size of the packing material), and As should be between 0.8 and 1.5.

3. Separation and Purification

3.1 Column Equilibration

Connect the chromatography column to the purification equipment, and rinse with binding buffer for more than 3-5 column volumes (CV) until the pH and conductivity of the column effluent are consistent with those of the binding buffer. Zero the UV detector after equilibration is completed.

3.2 Sample Loading

Load the sample solution filtered through 0.22/0.45 μm membrane onto the ion exchange chromatography column. The loading volume depends on the binding capacity of the chromatography medium, the concentration of the molecules bound to the medium in the sample solution, and other chromatographic conditions.

3.3 Column Washing

Rinse with binding buffer for 3-5 CV to remove impurities that do not bind to the medium under this condition (until the UV 280 detection value returns to near the baseline). Alternatively, perform column washing according to the impurity elution conditions determined in previous experiments.

3.4 Elution

Rinse the chromatography column with elution buffer, and start collecting the eluted sample when the target UV peak rises.

3.5 Washing and Storage

Wash with 1-2 M NaCl for 5 CV to remove reversibly bound impurities, then rinse with purified water until the conductivity of the effluent is 0, and finally rinse with 20% ethanol containing 0.2 M sodium acetate for 2-3 CV. Store the chromatography column in an environment at 2-8 ℃.Do not freeze.

4. Cleaning In Place (CIP)

Cleaning In Place (CIP) is the process of removing strongly bound, precipitated or denatured substances from the chromatography medium. Residual impurities will affect the chromatographic performance of the column. Severe aggregation will clog the chromatography column, increase back pressure and reduce flow rate. Therefore, regular CIP can prevent the accumulation of contaminants in the column bed and help maintain the binding capacity and flow rate of the medium.CIP should be performed after the chromatography column has been used for 3-5 cycles to restore the medium performance. Inorganic salts, acids, bases or organic solvents are usually used for cleaning. The recommended cleaning conditions for different types of impurities and contaminants are as follows:

4.1 Removal of impurities adsorbed by ion exchange

Wash the chromatography column with 2-3 CV of 2 M NaCl solution, then rinse the column with 3-5 CV of purified water.

4.2 Removal of protein precipitates and hydrophobic impurities

Soak the chromatography column in 1 M NaOH for more than 1 hour, then rinse the column with 5-10 CV of purified water.

4.3 Removal of strongly bound hydrophobic impurities

Rinse the chromatography column with 3-5 CV of 70% ethanol or 30% isopropanol for 15-20 minutes, then rinse the column with 3-5 CV of purified water.

4.4 Removal of nucleic acids

After rinsing with 1-2 CV of neutral buffer, wash with 2-5 CV of 0.1 M acetic acid at pH 3.0, then perform reverse flow washing with 1 M NaOH for 15-30 minutes. If the column is to be used immediately after cleaning, simply rinse with binding buffer for 3-10 CV.

5. Sanitization and Sterilization

Sanitization and sterilization are performed to minimize microbial contamination in the chromatography column. NaOH solution can be used as a disinfectant for this product. NaOH solution can effectively remove viruses, bacteria, yeast and endotoxins with extremely low operating costs. The sanitization steps are as follows:

5.1 Rinse the chromatography column with binding buffer for 3-5 CV.

5.2 Rinse the chromatography column with 0.5 M NaOH solution for 2-5 CV.

5.3 Soak the chromatography column in 0.5-1 M NaOH solution for 1 hour.

5.4 Rinse the chromatography column with binding buffer with pH between 7 and 8 for 5-10 CV to complete the sanitization process.

Precautions: When the chromatography column is severely contaminated, use 0.5 M NaOH mixed with 30-40% propanol for cleaning. High concentration of NaOH or prolonged NaOH treatment will reduce the binding capacity of the medium. Please pay attention to the cleaning concentration and time during sanitization.

6. Storage

Unused medium should be stored in a dry, ventilated and clean environment at 2-8 ℃, ensure the container mouth is completely sealed, and never freeze. Pre-packed chromatography columns should be soaked and sealed in 20% ethanol containing 0.2 M sodium acetate or 2% benzyl alcohol for storage to prevent microbial contamination.

7. Linear Scale-up

The optimized purification process at laboratory scale can be linearly scaled up to pilot or production scale. The following points should be noted during the scale-up process:

Keep the residence time unchanged to ensure the stability of the dynamic binding capacity.

Select the column volume according to the required binding capacity. If the column height is changed, pay attention to whether it will affect the purification steps.

Determine the column diameter according to the flow rate requirement, and determine the bed height according to the known residence time. The recommended bed height is generally 10-25 cm.

Ensure the sample concentration is uniform and consistent, and the elution conditions are the same.

Specifications

Especificaciones y pureza
BioReagent, 70% v/v; 75 μm
Estabilidad y almacenamiento
Store at 2-8℃ long term (60 months). Do not freeze.
Condiciones de almacenamiento de almacenamiento
Store at 2-8°C, Do not freeze
Enviado en
Wet ice
Este producto requiere envío en cadena de frío. Los servicios terrestres y otros servicios económicos no están disponibles.
Grado
BioReagent

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificados (CoA, COO, BSE/TSE y tabla de análisis)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Calculadoras de soluciones
Reseñas

Reseñas de cliente

Need help choosing the grade?

Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.

View BioReagent grade guide →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.