Uniform Polystyrene Microspheres - Color: blue, Size: 7.0μm, 2.5%w/v in Water - ethanol (1:1, v/v), Matrix: polystyrene

Cat. No.: C196694
Disponible para pedir
CALIDAD & PUREZA Color: blue, Size: 7.0μm, 2.5%w/v in Water - ethanol (1:1, v/v), Matrix: polystyrene
Storage
Protected from light,Room temperature
Shipped In
Normal
★
Talla
USA
Alemania (EU)*
Precio
Cantidad
10ml
C196694-10ml
2 Disponible
—

449,90US$

529,90US$
Guardar 80,00 US$ (15.10%)
Enter a quantity for the sizes you want to add.

Especificaciones

Especificaciones y pureza
Color: blue, Size: 7.0μm, 2.5%w/v in Water - ethanol (1:1, v/v), Matrix: polystyrene
Condiciones de almacenamiento de almacenamiento
Protected from light,Room temperature
Enviado en
Normal

Datos avanzados

Certificados (CoA, COO, BSE/TSE y tabla de análisis)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate TypeFechaArticulo
D2228116D2228116Certificate of AnalysisFeb 20, 2024 C196694
Propiedades químicas y físicas
Sensibilidadlight sensitive
Preguntas frecuentes y artículos
Calculadoras de soluciones
Reseñas

Reseñas de cliente

Application Protocols

No item-specific tested applications or protocols are provided in the Product Data. The following high-level workflows are general literature practices and should be optimized for your specific bead size/surface; they are not specifications for this SKU.

  • General suspension handling

    • Gently mix by inversion; avoid freezing unless permitted. If aggregates form, brief bath sonication (10–60 s) can help re-disperse.
  • Example: Passive protein adsorption (plain PS; literature/general)

    • Wash beads in PBS, resuspend in carbonate buffer pH 9.2, add protein at desired ratio, incubate 2–16 h at 4–25 °C with gentle rotation. Block with 1% BSA; wash 3× in PBS + 0.05% Tween 20.
  • Example: Colloidal crystal assembly (literature/general)

    • Clean glass slides, deposit bead suspension (0.1–1% v/v), allow slow evaporation in a dust-free enclosure. Control temperature/humidity for uniform domains.
  • Quality checks

    • Verify particle size/distribution via microscopy or DLS; confirm particle count by NTA or hemocytometer as needed.
  • For this SKU

    • Exact bead diameter, surface chemistry, concentration, and recommended buffers are Not specified for this item; refer to CoA/Spec Sheet for any lot-specific guidance.
Biological Roles

The product is a synthetic polymeric particulate and does not possess intrinsic biological roles. The information below provides general, non-clinical context for laboratory use.

  • General (literature/general)

    • Inert carrier: Polystyrene microspheres are commonly used as inert carriers for passive adsorption of proteins (e.g., antibodies, enzymes) due to hydrophobic interactions, enabling particle-based immunoassays and agglutination tests.
    • Model colloids: Serve as model systems to study colloidal interactions, Brownian motion, and cellular uptake mechanisms in vitro, with size-dependent endocytosis observed in many cell lines.
    • Optical standards: Due to their high refractive index, PS beads are used to characterize imaging systems and to calibrate scattering-based biophysical instruments.
  • Considerations

    • Endotoxin/bioburden levels and surfactant residues can impact cell-based experiments; for this item, such specifications are Not specified — verify via CoA if using in sensitive biological workflows.
    • Surface functionality is critical for specific bioconjugation; this item’s functional groups are Not specified.
  • Research Use Note (from Product Data)

    • For research use only. Not for human or animal diagnostic, therapeutic, or clinical use.
Buffer Applications

These microspheres are not buffering agents. However, their performance depends on the choice of suspension buffer. Item-specific buffer composition is Not specified for this item; refer to CoA/Spec Sheet.

  • General guidance for polystyrene bead suspensions (literature/general)

    • Working buffers: PBS or HEPES-buffered saline at pH ~7.2–7.6 commonly used. Maintain low-to-moderate ionic strength to balance colloidal stability and biomolecular interactions.
    • Surfactants: 0.01–0.1% nonionic surfactant (e.g., Tween 20) can reduce nonspecific aggregation; verify compatibility with assays.
    • Blocking: 0.1–1% BSA, casein, or fish gelatin can block nonspecific adsorption in bioassays using plain PS.
    • Antimicrobials: 0.02–0.05% sodium azide is sometimes included for storage stability in non-cellular assays; ensure compatibility with downstream processes and safety policies.
    • Filtration: Use 0.22–0.45 µm sterile filters for buffers when working with submicron beads to prevent introduction of dust/aggregates.
  • Not typically applicable

    • These beads do not provide buffering capacity; for actual pH control choose appropriate buffer systems separately.
Green Alternatives

While polystyrene microspheres are widely used, alternatives may offer environmental or safety advantages depending on the application.

  • Comparison (literature/general; not item-specific)

| Option | Advantages | Trade-offs | |---|---|---| | Silica microspheres | Inorganic, thermally stable, broad pH stability, low organic solvent swelling | Lower refractive index (~1.45), heavier (faster sedimentation), surface silanization needed for organics | | Cellulose/PLA/PLGA beads | Biobased/biodegradable, reduced persistence | Narrower solvent/pH windows, potential batch variability, lower optical index | | Poly(2-oxazoline)/PEG hydrogel beads | Aqueous, protein-resistant surfaces | Softer mechanics, lower optical contrast, potential dehydration issues | | 2-MeTHF-swollen PS loading (vs aromatics) | Greener solvent for dye swelling vs toluene/chloroform | Swelling efficiency may be lower; validate dye uptake |

  • Practical guidance

    • For optical calibration where high scattering is needed, PS remains superior. For environmentally considerate single-use assays, evaluate biodegradable carriers.
    • Waste management: Collect PS bead waste and minimize release to drains; consider filtration and solvent-free cleaning where feasible.
  • This item

    • Specific environmental certifications or recycled content: Not specified for this item; refer to CoA/Spec Sheet.
Pharmaceutical Uses

No therapeutic or clinical claims are made for this product. The following notes reflect general, non-clinical roles of polystyrene microspheres in development and manufacturing contexts.

  • General roles (literature/general)

    • Calibration and QC: Particle standards for validating particle sizers, filter integrity tests, and visual inspection systems in manufacturing environments.
    • Assay components: Carriers in in vitro diagnostic assay development (e.g., latex-enhanced immunoturbidimetry) during R&D. For regulated use, specifications such as particle size traceability, bioburden/endotoxin, and residual monomer levels must be qualified per application.
    • Process development: Model particulates to study filtration, mixing, and suspension dynamics in bioprocess engineering.
  • Regulatory notes

    • Pharmacopeial monographs generally do not apply to polystyrene beads as excipients; any use in GMP environments requires internal qualification and supplier documentation.
  • This item

    • Specific certifications (USP/EP/ISO), bioburden, endotoxin: Not specified for this item; refer to CoA/Spec Sheet.
    • Research Use Note: For research use only (from Product Data).
Physical Properties

Item-specific physical properties are not listed in the Product Data. Consult the CoA/Spec Sheet for particle size, concentration, and dispersion medium.

  • Item-specific (from Product Data)

    • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
    • Concentration/solids, size/size CV, surfactant, dispersant, and pH: Not specified for this item; refer to CoA/Spec Sheet.
  • Typical properties of polystyrene microspheres (literature/general; not item specifications)

    • Polymer density (bulk polystyrene): ~1.04–1.06 g/cm³ at 25 °C (literature); effective particle density may vary with porosity/crosslinking.
    • Refractive index (nD): ~1.59 at 589 nm (polystyrene; literature), enabling strong Mie scattering useful for optical calibration.
    • Glass transition temperature (Tg) of polystyrene: ~95–105 °C (literature); particles soften above Tg.
    • Solubility: Insoluble in water; soluble in aromatic solvents (e.g., toluene) and some chlorinated solvents (polymer literature). Intact microspheres are typically dispersed in aqueous media by surfactants without dissolution.
    • Surface charge: Plain polystyrene beads in water can exhibit slight negative zeta potential from adventitious sulfate end groups (emulsion polymerization; literature). Actual zeta potential for this item: Not specified.
  • Practical implications (general)

    • Sedimentation: Particles are denser than water; larger diameters settle faster (Stokes’ law). Gentle inversion or brief sonication can re-suspend; specific instructions for this SKU: Not specified for this item; refer to CoA/Spec Sheet.
Quality and Grades
  • Item-specific quality statements (from Product Data)

    • Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
    • Uniformity metrics (mean diameter, CV), surfactant type, endotoxin/bioburden levels: Not specified for this item; refer to CoA/Spec Sheet.
  • How to interpret quality for microspheres (general)

    • Size uniformity: Monodispersity is commonly expressed as coefficient of variation (CV). High-quality “uniform” microspheres often exhibit CV ≤ 5% (literature), enabling precise calibration and reproducible assay performance.
    • Concentration and solids: Reported as particles/mL and/or % solids. Verify by NTA/Coulter or manufacturer traceability for robust quantitation.
    • Surface chemistry: Plain (unfunctionalized) polystyrene relies on hydrophobic adsorption for protein capture. Functionalized variants (carboxyl, amino, streptavidin) offer covalent or high-affinity coupling. This item’s surface functionality: Not specified.
    • Optical traceability: For sizing/calibration, traceability to NIST or equivalent standards may be provided by some lots; check CoA for this SKU if required.
    • Cleanliness: Low residual monomer/surfactant and controlled endotoxin/bioburden are critical for bioassays. Values for this item: Not specified; refer to CoA.
  • Practical note

    • Match bead size and surface to your application. If you require certified diameters, fluorescence, or magnetic cores, confirm specifications on the CoA/Spec Sheet prior to use.
Reaction and Applications
  • Manufacturer Applications (from Product Data)

    • Not specified beyond product name. Typical uses expanded below are general for uniform polystyrene microspheres.
  • General applications (literature/general)

    • Analytical standards: Size and count standards for microscopy, particle sizing (DLS, NTA), and flow cytometry alignment/QA when appropriate size/fluorescence is available.
    • Assay development: Solid-phase capture in agglutination assays, latex-enhanced immunoassays, and turbidimetry using hydrophobic adsorption on plain beads. For covalent coupling, functionalized beads are preferred; functionality for this item is not specified.
    • Materials science: Templates for colloidal crystals, photonic bandgap materials, and inverse opals via infiltration and bead removal.
    • Separation and encoding: Barcoded/colored beads (if available) enable multiplexing; not specified for this item.
    • Education and method validation: Demonstrations of Brownian motion, Mie scattering, and Stokes’ sedimentation.
  • Practical tips (general)

    • Homogenization: Gently invert or roll; brief low-power bath sonication helps deaggregate. Avoid probe sonication unless validated, as it may fragment beads.
    • Surface blocking: For bioassays using plain PS, block non-specific binding with BSA or casein; verify compatibility with your detection chemistry.
    • Quantitation: Use hemocytometer, NTA, or flow cytometry for particles/mL; verify against CoA.
  • Limitations

    • Thermal sensitivity near Tg (~100 °C, literature). Solvent sensitivity to aromatics/chlorinated solvents. Functional coupling limited on plain PS without modification.
Reaction Conditions

This product is generally used as a particulate tool rather than a reactant. The following conditions reflect literature/general practices for working with polystyrene microspheres; they are not item-specific specifications.

  • Adsorptive immobilization (plain PS; literature/general)

    • Buffer: PBS or carbonate buffer pH 7.4–9.6. Protein loading often increases in slightly basic conditions.
    • Temperature/time: 4–25 °C, 1–16 h gentle mixing. Avoid foaming; rotate or end-over-end.
    • Post-treatment: Block with 0.1–1% BSA/casein; wash with buffer containing 0.01–0.1% nonionic surfactant.
  • Colloidal self-assembly (literature/general)

    • Solvent: Water or water/ethanol mixtures; slow evaporation or vertical deposition to form colloidal crystals.
    • Conditions: Clean substrates; control ionic strength to tune screening; ambient to 50 °C drying.
  • Dye loading by swelling (literature/general)

    • Swelling agents: Toluene or alternative swelling solvents; introduce dye, then deswell into non-solvent to trap dye. Note: Solvents like toluene can dissolve PS—optimize carefully; observe all safety rules.
  • Caution

    • For covalent coupling chemistries (EDC/NHS, glutaraldehyde), functional groups must be present; functionality for this item is Not specified. Verify bead surface prior to applying covalent protocols.
Safety and Handling
  • Item-specific hazard classification (from Product Data)

    • Signal word, H-statements, GHS classification, pictograms: Not specified for this item; refer to SDS for authoritative information.
  • General safety guidance for polystyrene microspheres (literature/general)

    • Expected hazards: Polystyrene is an inert polymer; dispersions are generally considered low hazard. Dry powders can present nuisance dust and potential combustible dust risks—avoid aerosol generation.
    • PPE: Wear safety glasses, lab coat, and appropriate gloves. Use a dust mask/respirator if handling dry powders or if aerosolization is possible; follow institutional risk assessment.
    • Handling: Gently invert to homogenize suspensions; avoid vigorous vortexing that can foam or shear aggregates. Prevent contamination of the suspension (use clean plastics/glassware).
    • Incompatibilities: Strong oxidizers and certain organic solvents may swell or dissolve polystyrene (e.g., toluene, chloroform). Avoid prolonged exposure of beads to aromatic/chlorinated solvents unless dissolution/swelling is intended.
    • First aid (overview): If eye contact occurs, rinse with water for several minutes; if inhaled (dust), move to fresh air; if skin contact, wash with soap and water. If ingested, rinse mouth and seek medical advice. Always defer to the product SDS.
  • Storage conditions (from Product Data)

    • Store protected from light at room temperature. Shipping condition: Normal. Avoid freezing unless explicitly allowed by CoA/SDS.
Solvent Selection

This product is a particulate dispersion or solid, not a molecular solvent. Solvent selection here refers to appropriate dispersion media for handling and application.

  • Item-specific medium: Not specified for this item; refer to CoA/Spec Sheet (common options include DI water with trace surfactant or buffered saline).

  • General guidance (literature/general)

    • Aqueous media: DI water, PBS, or low-ionic-strength buffers are typical. Add 0.01–0.1% nonionic surfactant (e.g., Tween 20) to minimize aggregation when appropriate to the application.
    • Organic exposure: Aromatic and chlorinated solvents can swell/dissolve polystyrene; avoid unless surface swelling is intentionally used for dye loading. Alcohols (EtOH, iPrOH) may partially dehydrate dispersions and promote aggregation.
    • Ionic strength and pH: Elevated ionic strength compresses double layers and can promote aggregation of unmodified beads. Maintain moderate ionic strength and neutral pH for colloidal stability, unless adsorption or flocculation is desired.
    • Comparative notes:
      • Polystyrene vs silica: Polystyrene is hydrophobic, buoyant in many density gradients, and optically higher index; silica is hydrophilic and stable in a wider pH range.
      • Plain vs functionalized PS: Plain relies on hydrophobic adsorption; carboxylated/amino beads support covalent coupling in buffered aqueous media.
Storage and Reconstitution
  • Storage (from Product Data)

    • Protect from light; store at room temperature. Shipping: Normal. Do not expose to extreme temperatures. If the product is supplied as a suspension, avoid evaporation and keep container tightly closed.
  • Item-specific formulation

    • Dispersant/buffer, surfactant, solids content, and preservatives: Not specified for this item; refer to CoA/Spec Sheet.
  • General guidance (literature/general)

    • Stability: Avoid freezing unless explicitly allowed, as freeze–thaw can cause irreversible aggregation or container rupture. Minimize headspace to reduce oxidative/evaporative changes in the medium.
    • Homogenization before use: Gently invert or roll to fully resuspend. If aggregates persist, short bath sonication (10–60 s) may be used; avoid harsh probe sonication.
    • Clean handling: Work in a clean environment to prevent dust contamination; use low-binding plasticware if protein adsorption is a concern.
    • Long-term storage: For extended storage, maintain original container and protect from UV/visible light to prevent photo-oxidation of the polymer. Do not add biocides or surfactants unless compatible with the intended application.
  • Reconstitution

    • If supplied as a dry powder (not specified), rehydrate with filtered buffer/water under gentle stirring; allow adequate time for wetting. Exact volumes and protocols: Not specified for this item; refer to CoA/Spec Sheet.
Structure and Identity

Item-specific identifiers from Product Data: not provided for this microsphere product. Where values are absent, consult the CoA/Spec Sheet or SDS.

  • Item-specific (from Product Data)

    • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
    • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
    • SMILES / InChI / InChIKey: Not applicable for particulate materials; not specified for this item.
    • CAS / CID: Not specified for this item; refer to CoA/Spec Sheet.
    • Grade/Purity, Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • General description (literature/general)

    • Composition: Polystyrene microspheres are spherical particles composed of atactic polystyrene, a hydrocarbon thermoplastic formed by radical polymerization of styrene.
    • Structural features: Repeating aromatic phenyl rings on a saturated carbon backbone [–CH2–CH(Ph)–]n confer hydrophobicity and a relatively high refractive index.
    • Particle architecture: Typically solid, monodisperse spheres. Some variants may be crosslinked (e.g., with divinylbenzene) or surface-modified; functionality for this specific item is not specified.
    • 2D structural depiction (conceptual): The repeating styrene unit contains a phenyl substituent on an ethylene backbone; in a sphere, polymer chains are entangled to form a dense, amorphous particle.
  • Identity considerations (general)

    • Uniformity refers to narrow size distribution (often quantified by coefficient of variation, CV). Exact mean diameter, CV, and surface chemistry for this SKU: Not specified for this item; refer to CoA/Spec Sheet.
Synthetic Utility

While not a reagent in the classical sense, uniform polystyrene microspheres provide valuable utility as solid supports and templates.

  • General utilities (literature/general)

    • Solid-phase platforms: Plain PS enables hydrophobic adsorption of small molecules, dyes, or proteins for bead-based screening and agglutination assays. Functionalized PS (e.g., COOH/NH2) supports covalent immobilization (EDC/NHS or carbodiimide, glutaraldehyde chemistries). Functionality for this item is Not specified.
    • Colloidal crystal templates: Close-packed PS spheres form opaline arrays that can be infiltrated (e.g., with silica, titania, or resists) to create inverse opals and photonic structures after bead removal.
    • Pickering emulsions: PS particles at interfaces can stabilize emulsions; wettability tuning via surface treatment improves performance.
    • Porous materials: Sacrificial templating yields macroporous foams or monoliths after polymer or ceramic curing and PS burnout/dissolution.
  • Advantages and cautions

    • Advantages: Highly uniform size distribution yields ordered packing and reproducible surface area. High refractive index aids optical manipulation and tracking.
    • Cautions: Sensitivity to organic solvents that swell/dissolve PS; thermal limitations near Tg; surface fouling in bioassays without adequate blocking.
  • Item-specific note

    • Exact size, surface chemistry, and concentration necessary for protocol design are Not specified for this item; consult CoA/Spec Sheet.
Target Specificity

Not applicable. This product is a material (uniform polystyrene microspheres), not a biological affinity reagent. No antigen/epitope, clone, isotype, or species reactivity applies.

  • Item-specific data from Product Data: None provided.
  • For affinity applications, select beads with the appropriate surface functionalization (e.g., streptavidin, Protein A/G, antibodies) — not specified for this item.

Preguntas frecuentes

How should this product be stored?
Store at room temperature, protected from light. The material is light-sensitive — keep it in its original opaque or amber container.
How is this product shipped?
This product ships under standard ambient conditions. No temperature-controlled packaging is required.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

¿Quieres que te enviemos un mensaje cuando tengamos descuentos disponibles?

Recordármelo más tarde

¡Gracias! Por favor, revisa tu bandeja de entrada de correo electrónico para confirmar.

¡Vaya! Las notificaciones están desactivadas.