Determine the necessary mass, volume, or concentration for preparing a solution.
최소한의 기준선 간섭이 필요한 민감한 크로마토그래피 및 분석 워크플로우용.
Store at -20°C,Avoid repeated freezing and thawing Ice chest + Ice pads 출고. 정확한 사양은 로트별 COA를 확인하세요.
SDS, COA, 데이터시트, 사양서를 다운로드할 수 있습니다. 로트별 COA는 로트 번호 조회를 통해 확인할 수 있습니다.
크로마토그래피, 유기 합성 및 교차 커플링 반응 분야의 동료 심사 논문 0편에서 인용되었습니다.
This product is a premixed system composed of Es Taq DNA Polymerase, Mg2+, dNTPs, PCR stabilizers and enhancers, with a concentration of 2 ×. Es Taq DNA Polymerase has excellent performance of high amplification efficiency and low mismatch rate. The unique MasterMix formula makes the entire reaction system very stable, with over 98% of PCR amplification successful at once. At the same time, complex templates can also be effectively amplified, and human error and contamination can be minimized to the greatest extent. This product has been added with a dye (blue), and can be directly subjected to electrophoresis detection after the reaction is completed. Most PCR products obtained from amplification have an "A" base attached to the 3 'end, making them suitable for direct use in T/A cloning. Mainly suitable for routine PCR reactions and gene cloning experiments that require high fidelity.
After testing, there was no exogenous nuclease activity; PCR method for detecting residual DNA without host; Can effectively amplify single copy genes from multiple genomes.
Notes: 2×Es Taq MasterMix contains Es Taq DNA Polymerase, 3mM MgCl2 and 400µM each dNTP. |
Usage:
The following is an example of a PCR reaction system and reaction conditions for amplifying a 1 kb fragment using human genomic DNA as a template. In practical operation, corresponding improvements and optimizations should be made based on the template, primer structure, and target fragment size.
1. PCR reaction system
|
Attention: The primer concentration should be between 0.1 and 1.0 as the final concentration μ M serves as a reference for setting the range. In the case of low amplification efficiency, the concentration of primers can be increased; When non-specific reactions occur, the primer concentration can be reduced to optimize the reaction system.
2. PCR reaction conditions
|
Attention:
1) In general experiments, if the annealing temperature is 5 ℃ lower than the melting temperature Tm of the amplification primer, and the ideal amplification efficiency cannot be achieved, the annealing temperature should be appropriately reduced; When non-specific reactions occur, increase the annealing temperature to optimize the reaction conditions.
2) The extension time should be set according to the size of the amplified fragment, and the amplification efficiency of Es Taq DNA Polymerase is 2 kb/min.
3) The number of cycles can be set based on the downstream application of the amplification product. If the number of cycles is too small, the amplification amount is insufficient; If there are too many cycles, the probability of mismatches will increase, and non-specific backgrounds will be severe. So, while ensuring product yield, the number of cycles should be minimized as much as possible.
위험성, 취급, 보관 및 규제 준수를 포괄하는 종합 문서.