ATP Determination Kit - BioReagent,for chemiluminescence,ready-to-use

Cat. No.: R1375244
주문 가능
등급 & 순도 BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. Ready-to-use ? Ready-to-use — supplied pre-formulated at working concentration, no prep needed. Use to save time and reduce pipetting/dilution errors. for Chemiluminescence ? Chemiluminescence grade — purity controlled to avoid quenching/background light. Use in chemiluminescent assays where signal fidelity is critical.
★
크기
USA
독일 (EU)*
가격
수량
100T
R1375244-100T
주문제작 · 8~12주
US$139.90
200T
R1375244-200T
주문제작 · 8~12주
US$199.90
Enter a quantity for the sizes you want to add.
🧪
이 등급을 선택하는 이유

BioReagent, ready-to-use, for chemiluminescence BioReagent,바로 사용 가능,화학발광용 최소한의 기준선 간섭이 필요한 민감한 크로마토그래피 및 분석 워크플로우용.

🌡

보관 및 배송

Protected from light,Store at -20°C Ice chest + Ice pads 출고. 정확한 사양은 로트별 COA를 확인하세요.

📋

품질 문서

SDS, COA, 데이터시트, 사양서를 다운로드할 수 있습니다. 로트별 COA는 로트 번호 조회를 통해 확인할 수 있습니다.

📚

문헌적 근거

크로마토그래피, 유기 합성 및 교차 커플링 반응 분야의 동료 심사 논문 0편에서 인용되었습니다.

개요

  ATP is the core molecule of cellular energy metabolism, and its concentration directly reflects the energy status of an organism and its organs. As a crucial energy substance, ATP participates in and regulates various physiological and pathological processes within cells; fluctuations in its levels significantly impact cellular function. Typically, ATP levels decrease during cell apoptosis, necrosis, or under toxic conditions, while specific stimuli like high glucose can upregulate ATP levels in certain cells. A decline in ATP often indicates impaired mitochondrial function and, during apoptosis, frequently occurs concurrently with a decrease in mitochondrial membrane potential.

  This kit is designed based on the catalytic principle of firefly luciferase: this enzyme requires ATP as an energy source to catalyze the light emission from luciferin. When both the luciferase and luciferin are in excess, the luminescence intensity is directly proportional to the ATP concentration within a certain range, enabling highly sensitive quantitative detection of ATP content in solutions, cells, or tissue samples.

  This kit can also be used to estimate cell concentration by measuring the amount of ATP released from living cell samples. This method specifically counts viable cells, as ATP is rapidly degraded upon cell death. Typically, each viable cell contains approximately 1 pg (10⁻¹² g) or about 2 fmol (2 × 10⁻¹⁵ mol) of ATP. For a specific cell line and growth medium, a more accurate ATP-to-cell ratio can be obtained by consulting the literature or by staining cells and counting viable cells under a microscope before measuring ATP content. Using the described method, this kit can measure ATP released from up to 5 × 10⁵ viable cells (sample density of 2 × 10⁷ cells/mL). Its sensitivity is significantly superior to that of microscopy-based counting using a hemocytometer, which typically detects only about 2 × 10⁵ cells/mL.

R1375244

Components

100T

200 T

Storage

Quantity Per Test

R1375244A

ATP Assay Lysis Buffer

50 mL

100 mL

-20℃

200μL

R1375244B

ATP Standard Solution, 0.5mM

0.1 mL

0.2 mL

-20℃, Store in the dark.

20μL

R1375244C

ATP Assay Reagent

10 mL

20 mL

-20℃, Store in the dark.

100μL

Precautions

1.   The detection reagent in this kit contains luciferase. Repeated freeze-thaw cycles will lead to gradual loss of its activity. For optimal results, after the first thaw, it can be appropriately aliquoted for storage. However, ensure the aliquoting containers are free from ATP contamination.

2.    Luciferase activity is sensitive to temperature. Therefore, both cells and the ATP detection reagent must be equilibrated to room temperature before the assay. Do not store the reagent at room temperature long-term.

3.    ATP, especially in lysed samples, is relatively unstable at room temperature. Operations should be performed on ice or at 4°C.

4.    Use white- or black-walled 96-well or 384-well plates suitable for cell culture for detection. Using standard clear plates may cause signal crosstalk between adjacent wells.

5.    Use 0.2 µm filtered ultrapure water (resistivity 17 MΩ·cm or equivalent specification).

6.    If dilution of sample solutions or dissolution of solid samples is required, the use of 0.2 µm filtered ultrapure water or a dilute buffer with a pH of approximately 7.8 is recommended. The use of arsenate as a sample buffer is not recommended, as it tends to reduce sensitivity through quenching. Additionally, high salt concentrations in samples can inhibit luciferase and decrease sensitivity. The Kₘ value for ATP increases with ionic strength.

7.    The addition of cell culture medium does not affect the detection reagent of this kit compared to simple ATP detection. If the medium contains unusually complex additional components, a preliminary test may be performed.

8.    The ATP Assay Lysis Buffer provided effectively lyses common cultured cells and tissues to release ATP. For certain specific tissues or samples, if the detected ATP level is significantly lower than expected, a portion of the lysate can be boiled for 2 minutes after lysis but before centrifugation to fully release ATP. Boiling will denature proteins, which will precipitate during subsequent centrifugation. Therefore, boiled samples cannot be used for protein concentration determination, SDS-PAGE, or Western blotting. Use the remaining, unboiled portion of the sample for these analyses.

9.    The final experimental results are closely related to factors such as reagent validity, the operator's technique, and the experimental environment. It is essential to pay close attention to these factors.

Instructions for Use 1 (Standard Curve Method)

1. Sample Preparation (Note: Perform cell/tissue lysis on ice or at 4°C):

(1) For Adherent Cells:

Aspirate the culture medium. Add lysis buffer proportional to 200 μL per well of a 6-well plate (i.e., approximately 1/10 of the 2 mL culture medium volume). Lyse the cells by pipetting up and down repeatedly or gently rocking the plate to ensure complete contact. Cells typically lyse immediately upon contact with the buffer. Centrifuge the lysate at 12,000× g for 5 minutes at 4°C. Collect the supernatant for subsequent assay.

(2) For Suspension Cells:

Centrifuge to pellet the cells, discard the supernatant, and gently resuspend the pellet. Add lysis buffer proportional to 200 μL per well of a 6-well plate (based on cell count). Lyse the cells by flicking the tube or brief vortexing to ensure complete contact. Cells typically lyse immediately. Centrifuge the lysate at 12,000× g for 5 minutes at 4°C. Collect the supernatant for subsequent assay.

(3) For Tissue Samples:

Add approximately 100-200 μL of lysis buffer per 20 mg of tissue. Homogenize using a glass homogenizer or other appropriate device. Thorough homogenization ensures complete lysis. Centrifuge the homogenate at 12,000× g for 5 minutes at 4°C. Collect the supernatant for subsequent assay.

2. Standard Curve Preparation:

Thaw the necessary reagents on ice. Dilute the ATP Standard Solution with the ATP Assay Lysis Buffer to create an appropriate concentration gradient. The specific concentrations depend on the expected ATP levels in your samples. For initial experiments, concentrations like 0.01, 0.03, 0.1, 0.3, 1, 3, and 10 µM can be tested. Adjust the range in subsequent experiments based on sample ATP concentrations.

3. ATP Concentration Measurement:

(1) Add 100 μL of the ATP Detection Reagent to each well of the assay plate. Incubate at room temperature for 3-5 minutes.

(2) Add 20 μL of the sample or the diluted ATP standard solution to the wells containing the reagent.

(3) Measure the Relative Light Units (RLU) using a luminometer.

Note: The sample volume can be adjusted within the range of 10-100 μL. If the ATP concentration in the sample is low, add up to 100 μL. If the concentration is high, use a smaller volume, ensuring the same volume is used for the standard curve dilutions. If the ATP concentration is exceptionally high, dilute the sample with ATP Assay Lysis Buffer before measurement.

Instructions for Use 2 (Internal Standard Method)

1. For Suspension Cells

(1) Sample Processing:

For suspension cells, samples can be directly taken for subsequent measurement.

(2) ATP Measurement:

① Add 100 μL of ATP detection solution to the required reaction wells. Let stand for 10 min or until equilibrated to room temperature.

② Sample Wells: Transfer 50 μL of the suspended cell sample into a microcentrifuge tube. Add 50 μL of pure water and 100 μL of detection lysis buffer. Mix thoroughly and lyse for 5-10 min. After lysis, transfer 100 μL of the mixture to a reaction well and mix.

③ Internal Standard Wells: Transfer 50 μL of the suspended cell sample into a microcentrifuge tube. Add 50 μL of ATP standard solution (as an internal standard) and 100 μL of detection lysis buffer. Mix thoroughly and lyse for 5-10 min. After lysis, transfer 100 μL of the mixture to a reaction well and mix.

Note: For optimal results, the amount of ATP spiked as the internal standard should be approximately equal to the amount of ATP present in the cell sample. The luminescence from the sample plus internal standard should be roughly double that of the sample alone.

④ Continue to incubate the plate at room temperature for 5-25 min to allow the luminescent signal to stabilize. Alternatively, measurements can be taken approximately every 5 min, using the value at the time point when the signal stabilizes as the experimental data.

⑤ Measure chemiluminescence using a multimode microplate reader equipped with chemiluminescence detection capability. Set the appropriate parameters according to the instrument's instructions and record the luminescence values.

(3) ATP Calculation

The amount of ATP in the cell sample can be calculated using the following formula:

Where:

ATP(SAM) is the amount of ATP in the cell sample (in moles)

ATP(IS) is the amount of ATP spiked as the internal standard (in moles)

L(SAM) is the luminescence emitted by the cell sample (value from the Sample Well)

L(SAM+IS) is the luminescence emitted by the cell sample plus the internal standard (value from the Internal Standard Well)

(4) Viable Cell Concentration Calculation (Omit if not required)

If the ATP content per cell is known (determined experimentally or obtained from literature), the number of viable cells per milliliter in the original sample can be estimated using the following formula:

2. For Adherent Cells

(1) Sample Processing:

Aspirate and discard the culture medium. Add lysis buffer to the wells at a ratio of 200 μL per well for a 6-well plate (equivalent to 1/10 of the 2 mL culture volume). To ensure complete lysis, use a pipette to repeatedly triturate or rock the plate to allow the lysis buffer to fully contact and lyse the cells. Lyse for 5-10 min before proceeding with the measurement.

(2) ATP Measurement:

① Add 100 μL of ATP detection solution to the required reaction wells. Let stand for 10 min or until equilibrated to room temperature.

② Sample Wells: Transfer 50 μL of the lysed sample into a microcentrifuge tube. Add 150 μL of ultrapure water and mix thoroughly. Transfer 100 μL of this mixture to a reaction well and mix.

③ Internal Standard Wells: Transfer 50 μL of the lysed sample into a microcentrifuge tube. Add 50 μL of ATP standard solution (as an internal standard) and 100 μL of ultrapure water. Mix thoroughly. Transfer 100 μL of this mixture to a reaction well and mix.

④ Continue to incubate the plate at room temperature for 5-25 min to allow the luminescent signal to stabilize. Alternatively, measurements can be taken approximately every 5 min, using the value at the time point when the signal stabilizes as the experimental data.

⑤ Measure chemiluminescence using a multimode microplate reader equipped with chemiluminescence detection capability. Set the appropriate parameters according to the instrument's instructions and record the luminescence values.

(3) ATP Calculation and Viable Cell Concentration Calculation:

Use the same formulas provided above in sections 1(3) and 1(4).

사양

동의어
Luminescent ATP Detection Assay Kit
사양 및 순도
BioReagent, ready-to-use, for chemiluminescence
등급
BioReagent, 바로 사용 가능, 화학발광용
감도
light-sensitive
보관 및 배송
보관 조건
Protected from light,Store at -20°C
배송
Ice chest + Ice pads
Contents & Storage

R1375244

Components

100T

200 T

Storage

Quantity Per Test

R1375244A

ATP Assay Lysis Buffer

50 mL

100 mL

-20℃

200μL

R1375244B

ATP Standard Solution, 0.5mM

0.1 mL

0.2 mL

-20℃, Store in the dark.

20μL

R1375244C

ATP Assay Reagent

10 mL

20 mL

-20℃, Store in the dark.

100μL

이미지
The performance of the ATP Determination Kit (R1375244) on ATP standards (0.01μM-10μM) 
The detection performance of this product for ATP standards. The data shown in the figure were obtained from 20 μL of standard combined with 100 μL detection reagent, incubated for 15 minutes, and then subtracted the blank control. Actual measured data may vary depending on the detection instrument and other factors. The data provided in the figure are for reference only.
The performance of the ATP Determination Kit (R1375244) on ATP standards (0.1nM-10μM) 
The detection performance of this product for ATP standards. The data shown in the figure were obtained from 100 μL of standard combined with 100 μL detection reagent, incubated for 15 minutes, and then subtracted the blank control. Actual measured data may vary depending on the detection instrument and other factors. The data provided in the figure are for reference only.

문서

📋 안전 데이터 시트(SDS)

위험성, 취급, 보관 및 규제 준수를 포괄하는 종합 문서.

<<<<<<< HEAD SDS 다운로드 → ======= SDS 다운로드 → >>>>>>> release248-p3

✅ 분석 성적서(COA)

로트별 품질 데이터. 로트 번호를 입력하여 정확한 COA를 확인하세요.

COA 조회 →

📊 데이터시트

제품 사양 및 응용 분야에 대한 빠른 참조 요약.

데이터시트 보기 →

🔬 사양서

이 등급의 전체 품질 특성 및 합격 기준.

사양서 보기 →

고급 데이터

인증서(CoA, COO, BSE/TSE 및 분석 차트)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

9 results found

Lot NumberCertificate Type날짜항목
ZJ26F0838456ZJ26F0838456Certificate of AnalysisAug 21, 2026 R1375244
ZJ26F0838455ZJ26F0838455Certificate of AnalysisAug 21, 2026 R1375244
ZJ26F0737089ZJ26F0737089Certificate of AnalysisJul 16, 2026 R1375244
ZJ26F0737088ZJ26F0737088Certificate of AnalysisJul 14, 2026 R1375244
ZJ26F0535390ZJ26F0535390Certificate of AnalysisMay 20, 2026 R1375244
ZJ26F0535389ZJ26F0535389Certificate of AnalysisMay 14, 2026 R1375244
ZJ26F0333247ZJ26F0333247Certificate of AnalysisMar 23, 2026 R1375244
ZJ26F0333248ZJ26F0333248Certificate of AnalysisMar 23, 2026 R1375244
ZJ25F1230217ZJ25F1230217Certificate of AnalysisDec 12, 2025 R1375244
자주 묻는 질문과 기사
Quantitative Determination of ATP by Luminescence and Its Application in Cellular Energetics
Rapamycin: A Life-Balance Regulator Born from Easter Island Soil
Technical Analysis and Clinical Applications of Lactate Dehydrogenase
Techniques for Assessing Cellular Energy Metabolism: Core Mechanisms of Glycolysis and the TCA Cycle, with Practical Assay-Kit Workflows
Bacterial Sodium Ion-Driven Energy Metabolism and Mechanisms of Transmembrane Coupled Transport
Ready-to-use Reagents
For Chemiluminescence
Mitochondrial Stress Signaling and Disease
Catalytic Mechanisms, Functional Division, and Research Applications of Key Enzymes in Microbial Acetate Metabolism
Role of ENTPD3 as an Islet β-Cell Marker and in Insulin Secretion
Targeting Mitochondria: Intervention Strategies for Tumor Energy Metabolism
솔루션 계산기
리뷰

고객 리뷰

등급 선택에 도움이 필요하신가요?

당사의 등급 선택 가이드는 카탈로그의 모든 변형 제품에 대해 순도, 안정제 상태 및 용도 적합성을 다룹니다.

BioReagent 등급 가이드 보기 → Ready-to-use 등급 가이드 보기 → for Chemiluminescence 등급 가이드 보기 →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.