Dexamethasone-d 4 is deuterium labeled Dexamethasone. Dexamethasone (Hexadecadrol) is a glucocorticoid receptor agonist. Dexamethasone also significantly decreases CD11b, CD18, and CD62L expression on neutrophils, and CD11b and CD18 expression on monocytes. Dexamethasone is highly effective in the control of COVID-19 infection. Dexamethasone inhibits production of exosomes containing inflammatory microRNA-155 in lipopolysaccharide-induced macrophage inflammatory responses.
사양
보관 조건
Store at -20°C
배송
Ice chest + Ice pads
이 제품은 콜드 체인 배송이 필요합니다.지상 및 기타 경제 서비스는 사용할 수 없습니다.
이름과 식별자
분자량
396.49
고급 데이터
인증서(CoA, COO, BSE/TSE 및 분석 차트)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
솔루션 계산기
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
리뷰
고객 리뷰
Application Protocols
Tested/validated applications: Not specified for this item; refer to CoA/Spec Sheet.
Recommended dilutions/conditions: Not specified for this item; refer to CoA/Spec Sheet.
Positive controls/standards: Not specified for this item; refer to CoA/Spec Sheet.
Note: While general LC–MS workflows for corticosteroids are widely available in the literature, only item-specific, supplier-validated protocols can be listed here; consult the product documentation for this SKU.
Biological Roles
Parent scaffold context (literature): Dexamethasone is a potent synthetic glucocorticoid that binds the glucocorticoid receptor (GR), modulating transcription via GREs (glucocorticoid response elements). In research, it is used to probe GR-mediated signaling, metabolism, and gene regulation.
Relevance of deuterated analogs in biology:
The deuterated variant (Dexamethasone-d) is not typically used to elicit biological responses; instead, it serves as a mass spectrometric tracer/internal standard to quantify the non-deuterated drug in complex biological matrices (plasma, serum, tissues, cell lysates).
Deuteration does not materially change receptor binding in most cases when labels are at non-exchangeable positions, but its primary role is analytical rather than pharmacological.
Metabolism and pathways (literature for parent compound):
Phase I transformations include reduction/oxidation at the 11β-hydroxyl/ketone system and side-chain modifications; Phase II conjugations commonly sulfate or glucuronidate hydroxyls.
In isotope-dilution studies, the internal standard co-experiences sample prep losses, enabling accurate recovery corrections without perturbing the biological system.
Experimental considerations:
Spike the internal standard at the earliest feasible step (e.g., at sample collection or before protein precipitation) to track matrix and handling losses.
Verify that deuterium labels are positioned to minimize H/D exchange under the pH and temperature conditions of your biological workflow (consult CoA).
Buffer Applications
This product is not a buffering reagent and is not typically used to prepare buffer systems.
Practical note: When used as an internal standard in bioanalytical assays, it is commonly prepared in organic solvent (DMSO, MeOH, or ACN) and then diluted into buffered mobile phases (e.g., water with 0.1% formic acid or ammonium formate) solely for chromatographic compatibility.
For buffer selection in LC–MS workflows, choose volatile systems (formate, acetate, 2–10 mM) to maintain signal quality and minimize salt deposition; this is general guidance, not item-specific.
Green Alternatives
Context: Dexamethasone-d is an isotopically labeled reference material; “greener” considerations focus on solvent and workflow selection rather than substitution of the analyte itself.
Solvent choices (greener options vs. conventional):
Methanol vs. acetonitrile: MeOH is generally preferred from a green chemistry perspective (renewable sources available, lower toxicity). However, ACN can provide sharper peaks and better deproteinization; choose MeOH when chromatographic performance remains acceptable.
Ethyl acetate or MTBE for LLE: EA is often considered greener than MTBE; evaluate extraction efficiency and emulsion tendency.
Aqueous mobile phases with low additive concentration (e.g., 0.05–0.1% formic acid) minimize solvent and salt load.
Process scale and waste minimization:
Miniaturize extraction (µL–mL scale) and use 96-well SPE/precipitation plates to cut solvent volumes.
Optimize injection volumes and column dimensions (narrow-bore, superficially porous particles) to reduce flow rates and solvent consumption without sacrificing sensitivity.
Comparison snapshot (general):
ACN (performance) vs. MeOH (greener) — tradeoff: backpressure and selectivity.
MTBE (volatile, less dense) vs. EA (greener, sometimes lower recovery) — tradeoff: phase separation ease.
Note: No direct “green substitute” exists for the analyte; ensure accurate isotopic labeling and stability data from the CoA to avoid re-runs and unnecessary resource use.
Pharmaceutical Uses
Role: Isotopically labeled internal standard for analytical and quality-control testing of dexamethasone and related corticosteroids. It is not intended for therapeutic use.
Typical applications in pharmaceutical analysis (general):
Bioanalytical method development and validation (e.g., per FDA/EMA guidance) for pharmacokinetic and exposure studies; the deuterated internal standard provides accuracy and precision across calibration ranges.
Release and stability testing: quantitation of dexamethasone in finished products or bulk materials by LC–MS/MS, supporting impurity profiling and content uniformity.
Cross-laboratory harmonization: use of a common labeled standard improves inter-lab comparability.
Formulation/excipient status: Not applicable; this product is supplied for research/analytical use only and is not an excipient.
Regulatory documentation:
CoA should be retained with analytical records to document identity, purity, and isotopic enrichment for each lot.
If used in GMP/GLP contexts, verify supplier qualifications and lot-specific data are suitable for the intended regulatory framework.
Note: No therapeutic, diagnostic, or clinical claims are made for this product. Handling and use are restricted to research and laboratory environments.
Physical Properties
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Melting point: Typical for dexamethasone (literature): ~262–264 °C (decomposition). Exact value for this deuterated analog is item-specific and may differ slightly; Not specified for this item.
Boiling point: Not applicable (decomposes before boiling; literature for parent compound).
Density: Not specified for this item; refer to CoA/Spec Sheet.
Solubility (literature, dexamethasone parent):
Water: very poorly soluble.
Organic: soluble in DMSO, methanol, ethanol, acetonitrile; limited solubility in nonpolar hydrocarbons.
Practical note: Prepare concentrated stock in DMSO or MeOH; dilute into aqueous buffers with co-solvent to avoid precipitation.
Partitioning (literature, dexamethasone parent): logP (XlogP3) ~1.9–2.0; pKa not ionizable under physiological pH for neutral form (phenolic/secondary alcohols only).
Spectral characteristics (general):
UV: enone chromophore absorbs in near-UV (~240–250 nm, literature for corticosteroid enones); exact extinction coefficient for the deuterated analog is not specified.
MS: Deuterated analog exhibits a +n Da mass shift relative to dexamethasone, where n equals the number of deuteriums (item-specific). Consult CoA for exact isotopic pattern and labeling positions.
Refractive index/optical rotation: Not specified for this item; refer to CoA/Spec Sheet.
Note: Where not explicitly provided above, values are literature guidance for the non-deuterated parent; use item CoA for method development and QC specifications.
Quality and Grades
Grade/Purity (item-specific): Not specified for this item; refer to CoA/Spec Sheet.
Isotopic labeling quality (general guidance for deuterated analytical standards):
Two independent quality dimensions are routine: chemical purity (area% by HPLC/GC/LC–MS) and isotopic enrichment (atom % D at labeled positions). High-quality internal standards often report ≥98% chemical purity and high isotopic enrichment (e.g., ≥98 atom% at labeled sites), but the exact values for this SKU are Not specified for this item.
Positional labeling (site specificity) matters for metabolic stability against H/D exchange. Verify labeling map on the CoA to ensure suitability for your matrix and extraction conditions.
Documentation and traceability:
Each lot typically ships with a Certificate of Analysis including: purity, isotopic enrichment, residual solvents, and recommended storage. For this SKU, consult the CoA/Spec Sheet for definitive values.
Implications for use:
For quantitative LC–MS/MS (isotope-dilution), match the internal standard’s chromatographic behavior to the analyte. Deuterium labels at non-exchangeable sites minimize retention time shifts and H/D back-exchange.
Stabilizers are generally unnecessary for solid steroid standards; if present in this SKU, they will be listed on the CoA. None are specified here.
Isotope-dilution mass spectrometry (IDMS): Dexamethasone-d is used as an internal standard to correct for variable extraction efficiencies, matrix effects, and ion suppression in LC–MS/MS assays targeting dexamethasone and related corticosteroids.
Method development: Co-elution with the native analyte enables accurate quantitation via analyte/IS peak area ratios. The deuterium-based mass shift allows clean MRM transition separation.
Protein precipitation with ACN or MeOH (3–4× volume), spiking the IS prior to precipitation.
Solid-phase extraction (SPE) using reversed-phase (C18) or polymeric sorbents; elute with MeOH or ACN. IS added before loading to track recoveries.
Liquid–liquid extraction from buffered matrices with MTBE or ethyl acetate; back-extract to mobile phase-compatible solvent.
Chromatography and MS considerations:
Reversed-phase LC with C18 or phenyl-hexyl columns; gradients from aqueous (0.1% formic acid) to organic (ACN or MeOH).
ESI positive mode typically affords strong [M+H]+; monitor MRM pairs offset by +n Da (n = number of deuteriums; item-specific). Verify transitions to avoid overlap with natural isotopologues.
Stability and exchange:
Maintain neutral to slightly acidic conditions in aqueous media to minimize H/D back-exchange if any labels reside at exchangeable positions; consult CoA for labeling map.
Additional research uses:
Recovery studies, matrix effect evaluations, and cross-validation between platforms (LC–MS vs. GC–MS after derivatization) where an isotopically labeled internal standard is essential.
Reaction Conditions
Analytical method conditions (general LC–MS/MS guidance for corticosteroids; adapt to your system):
Columns: C18 (2.1 × 50–100 mm, 1.7–3 µm) or phenyl-hexyl for π–π interactions.
Mobile phases: A = water + 0.05–0.1% formic acid (or 2 mM ammonium formate); B = ACN or MeOH.
Gradient: 20–60% B over 3–6 min, then wash and re-equilibrate (adjust for resolution of isobars/isomers).
Flow: 0.2–0.5 mL/min; Column temp: 30–45 °C.
MS: ESI(+) with MRM transitions specific to the analyte and deuterated IS (mass shift = +n Da; n is item-specific per CoA). Optimize collision energies empirically.
Sample prep (literature examples):
Protein precipitation: Add 3–4 volumes of cold ACN containing the internal standard to plasma/serum; vortex, centrifuge, and inject supernatant after dilution.
SPE: Condition (MeOH, then water), load sample spiked with IS, wash (5–10% MeOH in water), elute (MeOH or ACN), evaporate, and reconstitute in initial mobile phase.
LLE: Buffer to pH ~7–8, extract with MTBE or EA, evaporate, and reconstitute.
Stability considerations:
Keep extracts at 2–8 °C during batch runs; store long-term at −20 °C or below. Minimize cycles of drying/reconstitution to reduce adsorption losses.
Yields/metrics: Not applicable; use assay precision (%CV) and accuracy (%bias) with and without IS to evaluate performance (per bioanalytical validation guidance).
Safety and Handling
GHS/Classification (item-specific):
Signal word: Not specified for this item; refer to SDS.
Hazard statements: Not specified for this item; refer to SDS.
GHS pictograms: Not specified for this item; refer to SDS.
Storage conditions (Product Data): Store at −20 °C. Shipments are sent in an ice chest with ice pads to maintain cold chain.
General handling recommendations (research use only):
Work in a well-ventilated area or fume hood; avoid aerosolization and dermal exposure to steroidal compounds.
Use appropriate PPE: lab coat, safety glasses, and nitrile gloves; change gloves regularly to minimize permeation by organic solvents.
Avoid contact with strong oxidizers and strong acids/bases that may degrade the enone or hydroxyl functionalities.
First-aid overview (general):
Inhalation: Move to fresh air; seek medical attention if symptoms occur.
Skin contact: Wash with soap and water; remove contaminated clothing.
Eye contact: Rinse cautiously with water for several minutes; remove contact lenses if present and easy to do.
Ingestion: Rinse mouth; seek medical advice.
Waste and decontamination:
Collect organic solvent solutions and contaminated disposables as halogen-free organic waste unless otherwise required by local regulations.
Clean work surfaces with ethanol or isopropanol; avoid bleach with organic residues.
Authoritative information: Always consult the SDS for this specific SKU for definitive hazard, exposure controls, and regulatory details.
Solvent Selection
Polarity and solvation (general for dexamethasone analogs): Moderately lipophilic with multiple hydroxyls; dissolves well in polar aprotic/protic organic solvents (DMSO, methanol, ethanol, acetonitrile) and poorly in water.
Recommended solvents by use case (method-development guidance):
Stock solutions: DMSO (50–20,000 µg/mL) or MeOH/ACN (with 0.1% formic acid if LC–MS-compatible).
Working standards: Dilute with 50:50 ACN:water or MeOH:water containing 0.1% formic acid or 2 mM ammonium formate to enhance electrospray response.
Sample preparation: SPE elution with MeOH or ACN; LLE using ethyl acetate or MTBE from buffered aqueous matrices (pH ~7–8; literature).
Miscibility/compatibility (literature):
DMSO, MeOH, EtOH, and ACN are mutually miscible with water up to high fractions; avoid high aqueous content at low analyte concentrations to prevent precipitation.
Avoid strong bases/acids that may induce retro-aldol or hydration across the A-ring enone over prolonged exposure.
Choosing among alternatives:
DMSO maximizes solubility and stability for concentrated stocks but can suppress ESI in high percentages.
MeOH offers robust ESI signal and greener profile versus ACN; ACN can afford sharper peaks and lower backpressure in LC.
For NMR, CDCl3 or DMSO-d6 are suitable; beware H/D exchange in protic deuterated solvents if labeling includes exchangeable sites (verify with CoA).
Storage and Reconstitution
Storage (Product Data): Store at −20 °C. Shipped in an ice chest with ice pads to maintain a low temperature during transit.
Light/moisture: Protect from light and moisture. Store in tightly closed, inert atmosphere containers when possible.
Stability (general guidance): Solid deuterated steroid standards are typically stable for extended periods at −20 °C when kept dry. In solution, stability depends on solvent and temperature; DMSO or MeOH stocks stored at −20 °C are commonly stable for weeks to months. Exact shelf-life for this SKU is Not specified; consult CoA.
Reconstitution (general guidance for analytical use):
Allow vial to equilibrate to room temperature in a desiccator before opening to avoid condensation ingress.
Prepare a concentrated stock (e.g., 0.1–1.0 mg/mL) in LC–MS–compatible solvent such as DMSO, methanol, or acetonitrile.
Vortex to fully dissolve; if needed, sonicate briefly. Filter through 0.2 µm PTFE only if particulate is present.
Aliquot into low-adsorption vials to avoid repeated freeze–thaw; store aliquots at −20 °C or below. Minimize headspace to reduce evaporation.
Freeze–thaw: Avoid multiple cycles; thaw on ice and keep solutions cold during use. Discard aliquots showing precipitation or unexpected LC–MS response drift.
Documentation: Record preparation date, solvent, and concentration on the vial and in your ELN/LIMS; link to the lot’s CoA for traceability.
Structure and Identity
Item-specific identifiers (this SKU):
CAS: 2305607-27-4 (as provided)
Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
InChIKey: Not specified for this item; refer to CoA/Spec Sheet.
Compound type: Deuterium-labeled analog of dexamethasone intended for research use (commonly employed as an internal standard in analytical workflows).
Structural features (general, based on the dexamethasone scaffold; literature):
Tetracyclic steroid nucleus (cyclopentanoperhydrophenanthrene core) with an A-ring enone (3-keto-Δ4) functionality.
Characteristic substituents: 9α-fluoro, 11β-hydroxyl, 16α-methyl, 17α-hydroxyl, 20-keto/21-hydroxyl side chain.
Multiple stereocenters typical of corticosteroids; configuration follows that of dexamethasone (literature), while the deuterium labeling replaces one or more hydrogens at defined positions without altering carbon stereochemistry.
Isotopic labeling note:
“-d” indicates incorporation of deuterium (2H). The number and positions of deuterium atoms determine the exact formula and mass shift; these are item-specific and should be confirmed from the CoA/Spec Sheet for this SKU.
2D description (general): Four fused rings (three six-membered and one five-membered); an enone on the A-ring, hydroxyls at C11, C17, and C21, a ketone at C3 and C20, a 9α-fluoro substituent, and a 16α-methyl group. Deuterium substitution occurs at specified C–H positions but does not change the core topology.
Synthetic Utility
General perspective: Dexamethasone-d is not commonly employed as a synthetic building block; its primary value lies in its defined isotopic composition for analytical quantitation. Nevertheless, understanding its functional groups informs derivatization or reference method development.
Functional group reactivity (inherited from dexamethasone; literature):
A-ring enone (3-keto-Δ4): susceptible to Michael additions and conjugate reductions under strong conditions (typically avoided in analytical workflows).
Secondary/primary alcohols (11β, 17α, 21): can be esterified or silylated (e.g., TMS derivatives for GC–MS reference methods).
20-ketone: amenable to oxime formation or hydrazone derivatization; can improve detectability in certain methods.
Use in method harmonization:
The labeled analog can be derivatized in parallel with the analyte (e.g., MSTFA silylation) to act as an internal standard for GC–MS protocols when LC–MS is unavailable.
Isotopic integrity considerations:
Avoid conditions that promote H/D exchange if labels reside at exchangeable positions (protic acids/bases, elevated temperature, long reaction times). Confirm labeling map on the CoA before any derivatization.
Retrosynthetic value: Limited; any synthetic studies typically pertain to preparation of the labeled standard itself (site-selective deuteration), which is outside routine user scope but underscores the stability constraints during analytical derivatizations.
Target Specificity
Not applicable to this product type. This SKU is a small-molecule, deuterated steroid standard and is not an antibody or affinity reagent.
No antigen/epitope, clone, isotype, or species reactivity information applies.
For analytical specificity, consult the CoA for exact deuterium labeling and verify that the selected MRM transitions do not overlap with the natural isotopic envelope of dexamethasone under your instrument conditions.
자주 묻는 질문
How should this product be stored?
Store at ?20 °C. Freezer storage is required to maintain the specified shelf life.
How is this product shipped?
This product ships in an insulated container with ice pads. Unpack on arrival and transfer it to the storage condition stated above.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 2305607-27-4, the molecular formula is C22H25D4FO5, and the molecular weight is 396.49 g/mol.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.