등급 & 순도BioReagent?BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
DNA Grinding Buffer is composed of Tris, NaCl, EDTA, SDS, and distilled water. It is used for the grinding treatment of samples during DNA extraction, facilitating cell lysis and nucleic acid release.
사양
사양 및 순도
BioReagent
보관 조건
Store at 2-8°C
배송
Wet ice
이 제품은 콜드 체인 배송이 필요합니다.지상 및 기타 경제 서비스는 사용할 수 없습니다.
등급
BioReagent
Product Line
생물 제품
고급 데이터
인증서(CoA, COO, BSE/TSE 및 분석 차트)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
솔루션 계산기
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
리뷰
고객 리뷰
Application Protocols
No manufacturer-validated application protocols, tested applications, or recommended dilutions are provided for this item.
Item-specific note
Not specified for this item; refer to CoA/Spec Sheet for any lot-specific instructions.
General guidance (non-specific)
Follow standard DNA extraction SOPs appropriate to your sample type (plant, fungal, animal) and ensure compatibility of this buffer with the chosen downstream method. Perform small-scale pilot tests to optimize sample-to-buffer ratios and processing times.
All procedures should be validated by the end user for their specific application.
Biological Roles
This product is a laboratory buffer and has no intrinsic biological role in vivo. The following points describe the biochemical rationale for buffer components typically used in DNA grinding formulations (general literature context; exact composition of this item is not specified):
pH control
Buffers such as Tris maintain near-neutral to slightly basic pH (~7.5–8.5, literature) to minimize acid-catalyzed depurination of DNA.
Nuclease inhibition
Chelators (e.g., EDTA) sequester Mg2+/Mn2+, essential cofactors for many DNases, thereby reducing nuclease activity during homogenization.
Membrane/protein disruption
Ionic detergents (e.g., SDS, N-lauroylsarcosine) disrupt lipid bilayers and denature proteins, facilitating DNA release.
Polyvinylpyrrolidone (PVP) can bind polyphenols that otherwise oxidize and crosslink nucleic acids; reducing agents or sulfite salts can limit phenolic oxidation (literature practices).
Ionic strength effects
Salts (e.g., NaCl) stabilize duplex DNA and can assist in selective precipitation or phase partitioning during subsequent extraction and purification steps.
These biochemical functions collectively support the preservation of high-molecular-weight DNA during the physical stress of grinding/homogenization. Always consult the product CoA to determine which of these elements apply to this specific buffer.
Buffer Applications
This section outlines practical, laboratory-focused uses of DNA grinding buffers in nucleic acid workflows. Exact composition/pH/concentration for SKU D1528828 are not specified here; consult the CoA/Spec Sheet.
Typical use cases (literature/general)
Homogenization of plant, fungal, or animal tissues prior to DNA extraction.
Initial lysis medium preceding CTAB-based precipitation, organic extraction, or silica/magnetic-bead purification.
Stabilization of DNA during mechanical disruption and brief holding on ice.
Practical guidance
Temperature: Use chilled (2–8°C or on ice) during grinding to suppress nucleases.
Ratios: Common sample-to-buffer mass/volume ratios range 1:5 to 1:10 (w/v) for plant tissues (literature). Adjust based on tissue toughness and downstream capacity.
Clarification: Centrifuge the crude homogenate to pellet debris; decant supernatant for downstream processing.
Additives: If permitted by the product label, RNase A may be added when DNA-only preparations are desired; for polyphenol-rich samples, PVP supplementation is common in literature protocols.
Typical pH/ionic ranges (for context; not product specs)
pH ~7.5–8.5; NaCl from 0.1 to 1.5 M depending on protocol aims (e.g., protein precipitation vs. DNA solubility control). Detergent content varies widely (0–2% w/v).
Compatibility notes
Ensure compatibility with downstream kits (column/bind–wash–elute systems often specify allowable detergents and salt limits in the initial lysate). Preservatives in the buffer, if any, may inhibit enzymes—verify before direct enzymatic use.
Green Alternatives
Aqueous buffers are generally aligned with green chemistry principles; however, environmental impact depends on additives (detergents, chaotropes, preservatives) and waste handling.
Current product context
Composition of this item is not specified; refer to CoA/Spec Sheet for any preservatives or surfactants that may influence environmental profile.
Greener practice considerations (literature/general)
Prefer water-based buffers without hazardous preservatives (e.g., avoid sodium azide when feasible) and with biodegradable surfactants.
Minimize or eliminate phenol/chloroform extractions by using silica columns or magnetic beads downstream, reducing halogenated waste.
Use right-sized aliquots to reduce spoilage and bioburden-related disposal.
Comparison (general)
Conventional option: Phenol–chloroform extraction following lysis; excellent purity but produces toxic/halogenated waste and poses user hazards.
Greener alternative: Column/bead-based DNA purification using aqueous salt/ethanol systems; lower hazard profile, reduced VOC/halogenated waste, with comparable yields for many sample types.
Detergent choice: SDS is effective but persistent; alternatives like N-lauroylsarcosine are easier to rinse and may be less foaming; nonionic detergents (e.g., Triton X alternatives with better biodegradability) can be considered when compatible.
Waste management
Collect any detergent- or preservative-containing waste per institutional guidelines. Avoid drain disposal unless permitted. Rinse containers thoroughly before recycling if allowed.
Pharmaceutical Uses
This is a research-use-only laboratory buffer and is not intended for clinical or therapeutic applications.
Item-specific restriction
Research Use Note: For research use only (from Product Data). Not for drug, diagnostic, or in vivo use.
Excipients/formulation context
Not applicable. DNA grinding buffers are not used as pharmaceutical excipients. If buffer constituents (e.g., Tris, NaCl) appear in pharmacopeial contexts, their quality and regulatory status differ from research-grade mixtures.
For any regulated application, consult appropriate pharmacopeial monographs and use GMP-grade materials specifically qualified for that purpose.
Physical Properties
Item-specific specifications
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
pH, ionic strength, conductivity, buffer capacity: Not specified for this item; refer to CoA/Spec Sheet.
Density, refractive index, viscosity: Not specified for this item; refer to CoA/Spec Sheet.
Boiling point, melting point: Not applicable/relevant for an aqueous laboratory buffer; not specified for this item.
General/literature expectations for DNA grinding buffers (informational; not product specs)
Physical state: Typically a clear, colorless aqueous solution; some plant-focused formulations may appear slightly opaque if containing suspended polymer/insoluble components.
Typical pH range (literature): ~7.5–8.5 to preserve DNA integrity and reduce acid-mediated depurination.
Typical ionic components: Alkali metal salts (e.g., NaCl 0.1–1.5 M, literature ranges) to promote DNA stability or assist with protein aggregation/removal during subsequent steps.
Optional additives: Chelators (e.g., 1–10 mM EDTA, literature) to inhibit Mg2+-dependent nucleases; detergents (e.g., 0.1–2% w/v SDS or N-lauroylsarcosine, literature) to disrupt membranes; antioxidants/polyphenol binders (e.g., PVP, sodium sulfite, literature) for plant tissues.
Solubility profile (general)
Fully miscible with water by design; miscibility with organic solvents depends on detergent/polymer content. Not intended for nonaqueous media.
Important note: For exact values relevant to this specific item (pH, salt concentration, presence/absence of detergents or chelators), consult the product CoA/Spec Sheet.
Quality and Grades
Item-specific grade (from Product Data)
BioReagent grade: Intended for research and laboratory use. No medical/clinical use. Quality suitable for common molecular biology workflows, subject to the product’s specifications on the CoA.
What BioReagent typically implies (general explanation)
Sourcing and processing designed to minimize impurities that interfere with biochemical assays (e.g., nucleases, proteases, heavy particulates). For buffers used in DNA workflows, this often includes low bioburden and low nuclease activity (DNase/RNase-free status only if explicitly stated on the CoA/label).
UV transparency and chromatographic background are usually not defining criteria (unlike HPLC grade solvents). Instead, composition accuracy, pH control, and ionic strength consistency are key.
Stabilizers and preservatives
Not specified for this item; refer to CoA/Spec Sheet. If a preservative (e.g., sodium azide, ProClin) is present, it will be declared on the label/CoA; such additives improve shelf life but may affect enzyme-based downstream steps and require specialized disposal.
Release testing (context, general)
Typical release controls for similar buffers include pH, conductivity/ionic strength, identity by formulation check, appearance, and bioburden or nuclease tests when applicable. The exact tests for this product are not specified here; consult the CoA for definitive criteria.
Reaction and Applications
Primary application: mechanical disruption of cells/tissues while maintaining DNA integrity for subsequent purification. The buffer conditions aim to mitigate nuclease activity, solubilize membranes, and manage interfering compounds.
Item-specific facts
Intended use: DNA Grinding Buffer (research use only; see Product Data). Specific additives and concentrations are not specified for this item; refer to CoA/Spec Sheet.
Pre-lysis medium for tissue grinding with mortar and pestle, bead mill, rotor–stator, or cryogenic grinding (liquid nitrogen) prior to DNA isolation.
Initial extraction step for plant tissues, fungi, and some animal tissues to generate a crude lysate compatible with downstream clarification (centrifugation/filtration) and DNA capture (e.g., CTAB precipitation, silica binding, magnetic beads).
Nuclease inhibition via chelation (e.g., EDTA) and pH control; salt supports DNA structural stability while aiding in protein aggregation or phase partitioning during organic extraction steps.
Practical tips (general, not product-specific)
Work cold to minimize nuclease activity; pre-chill tubes and pestles.
Use appropriate sample-to-buffer ratios; insufficient buffer leads to localized heating and nuclease activation.
If polysaccharides or polyphenols are problematic (common in plants), consider adding PVP or reducing agents if compatible with the supplied buffer (only if permitted by the CoA/label).
Clarify lysate promptly (centrifuge 10–20 min, literature) to remove debris and proceed to DNA purification to minimize degradation.
Note: Follow the specific instructions on the item’s label/CoA when available; do not assume the presence of any particular component.
Reaction Conditions
There are no chemical reaction conditions specific to this product in the sense of synthetic transformations. The relevant “conditions” relate to sample processing during DNA extraction.
Item-specific
No manufacturer protocols provided. Composition and specific instructions are not specified for this item; refer to CoA/Spec Sheet.
General/literature guidance for sample processing
Temperature: Keep buffer and samples cold (2–8°C or on ice) during grinding to reduce nuclease activity.
Time: Minimize dwell time between homogenization and downstream stabilization/clarification to preserve DNA integrity.
Equipment: Mortar and pestle (often pre-chilled), bead mill, or rotor–stator homogenizer. For hard/woody tissues, cryogenic grinding with liquid nitrogen is common.
Centrifugation: Clarify lysates (e.g., 10–20 min at 10,000–20,000 × g, literature) before proceeding to DNA capture.
Compatibility: Verify detergent/salt tolerance of downstream binding matrices or enzymes.
These are general best practices, not product-specific specifications. Always defer to the product label/CoA and institutional SOPs.
Safety and Handling
Authoritative safety information must be taken from the SDS for SKU D1528828.
Item-specific hazard information
Signal word: Not specified for this item; refer to SDS.
H-statements: Not specified for this item; refer to SDS.
GHS classification and pictograms: Not specified for this item; refer to SDS.
General handling guidance for DNA grinding buffers (literature/general)
PPE: Wear lab coat, safety glasses, and appropriate gloves. If the buffer contains detergents (common in lysis/grinding buffers), use nitrile gloves and avoid generating aerosols; work in a fume hood if splashing or aerosolization is possible.
Incompatibilities: Avoid contact with strong oxidizers and acids/bases that could alter buffer pH or hydrolyze components; keep away from reactive metals if chelators are present.
First aid overview: In case of skin/eye contact, rinse with water for at least 15 minutes. If inhaled (aerosols), move to fresh air. If ingested, rinse mouth and seek medical attention. Always follow institutional SOPs.
Spill response: For small spills, absorb with inert material, collect for disposal; wash area with water. For large spills, contain and consult EHS.
Special risks: Some grinding buffers include SDS or similar surfactants that can cause skin/eye irritation; chelators can mobilize metals from surfaces; high-salt buffers may corrode certain metals.
Storage conditions (from Product Data)
Store at 2–8°C. Avoid microbial contamination; keep container tightly closed. Do not freeze unless the label/CoA explicitly permits.
Solvent Selection
This product is an aqueous buffer intended to be used as supplied.
Item-specific note
Formulation medium: Water (implied by buffer designation). Exact composition, pH, and salt/detergent content are not specified for this item; refer to CoA/Spec Sheet.
General guidance for choosing/using grinding buffers (literature)
Polarity and dielectric: Highly polar, high dielectric medium (water-based), supporting ionic strength needed for DNA stability and protein solubilization/precipitation.
Miscibility: Fully miscible with water; miscibility with alcohols (ethanol/isopropanol) is typically complete, but mixing may change effective buffer strength and can precipitate proteins or nucleic acids.
Compatibility: Suitable for tissue homogenization prior to DNA isolation. If phenol–chloroform extraction follows, ensure buffer pH and salt content are compatible with the extraction step. For silica-column workflows, high-salt chaotrope steps usually occur downstream; this grinding buffer provides the initial lysate environment.
Temperature use: Often used chilled (on ice or 2–8°C) to slow nuclease activity during grinding/homogenization.
When to choose alternatives
For polysaccharide/polyphenol-rich plant tissues, formulations with PVP and antioxidants can improve DNA quality (literature). For high-fat/membrane-rich samples, stronger detergents may be beneficial. If downstream enzyme reactions are immediate, choose buffers free of preservatives/detergents that inhibit polymerases.
Store at 2–8°C. Shipped on wet ice. Research use only.
Reconstitution/use
Physical form, concentration, and appearance are not specified for this item; refer to CoA/Spec Sheet. If supplied as a ready-to-use solution, employ directly without dilution. If supplied as a concentrate or dry mix, reconstitute/dilute with nuclease-free water per the label instructions.
Handling practices (general)
Mix gently before use to ensure homogeneity; avoid introducing bubbles/foam if detergents are present.
To minimize contamination and extend shelf life, work aseptically, use clean nuclease-free tools, and consider aliquoting into sterile containers to avoid repeated freeze–thaw or repeated warming.
Do not freeze unless explicitly permitted on the label/CoA; some buffers precipitate or phase-separate upon freezing due to salts/detergents.
Stability
Expiration date, pH, and any preservative content are not specified for this item; consult the CoA/Spec Sheet. Discard if turbidity, precipitate (not reversible by gentle warming), color change, or microbial growth is observed.
Always defer to the product label and lot-specific CoA for definitive instructions.
Structure and Identity
Concise overview: This product is a formulated aqueous buffer intended for mechanical disruption (grinding/homogenization) of biological samples prior to DNA isolation. It is a mixture, not a single defined compound.
Item-specific facts (from Product Data)
Product name: DNA Grinding Buffer (SKU: D1528828)
Grade: BioReagent
CAS: Not specified for this item; refer to CoA/Spec Sheet.
Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
SMILES / InChI / InChIKey: Not applicable to a multi-component mixture; not specified for this item.
General/literature description of typical composition (for context; exact composition of this item is not specified)
DNA grinding buffers commonly include an aqueous base buffered near neutral to slightly basic pH (e.g., Tris), chelators (e.g., EDTA) to inhibit nucleases, salts (e.g., NaCl) to stabilize DNA and modulate protein solubility, and optionally detergents (e.g., SDS, Sarkosyl) or polymers (e.g., PVP for polyphenol-rich plants). The exact components and concentrations vary by formulation.
Structural features (general, literature)
As an aqueous mixture, the “structure” consists of solvated ions and small molecules in water; there is no single 2D/3D molecular structure. Functional groups present depend on the buffer constituents (typical: amines from Tris, carboxylates/borates/chelates, sulfate groups from detergents).
Synthetic Utility
Not typically applicable. DNA Grinding Buffer is a prepared aqueous mixture designed for biomolecular sample preparation, not for use as a synthetic reagent or building block.
General note (literature)
While high-salt or detergent-containing aqueous media can influence biomolecule extraction or protein denaturation, they are not used as reagents in organic synthesis or materials construction.
Users interested in chemical synthesis should refer instead to dedicated reagents and solvents appropriate to their reaction class.
Target Specificity
Not applicable. This product is a buffer solution and is not an antibody, enzyme, probe, or affinity reagent with biological target specificity.
Item-specific data
No antigen/epitope, clone, isotype, or species reactivity information applies.
등급 선택에 도움이 필요하신가요?
당사의 등급 선택 가이드는 카탈로그의 모든 변형 제품에 대해 순도, 안정제 상태 및 용도 적합성을 다룹니다.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.