Determine the necessary mass, volume, or concentration for preparing a solution.
최소한의 기준선 간섭이 필요한 민감한 크로마토그래피 및 분석 워크플로우용.
Store at 2-8°C,Protected from light Wet ice 출고. 정확한 사양은 로트별 COA를 확인하세요.
SDS, COA, 데이터시트, 사양서를 다운로드할 수 있습니다. 로트별 COA는 로트 번호 조회를 통해 확인할 수 있습니다.
크로마토그래피, 유기 합성 및 교차 커플링 반응 분야의 동료 심사 논문 0편에서 인용되었습니다.
Product content
|
Products
The High Sensitivity Chemiluminescent Assay is a highly sensitive and enhanced assay for use with horseradish peroxidase (HRP) in immunoblotting experiments. It is based on a new generation of enhanced chemiluminescent substrate, which is catalyzed by HRP to emit light, and can be used to detect biological macromolecules such as proteins immobilized on membranes. The high sensitivity enables the detection of pg-level antigens with a strong and long-lasting luminescence signal, which can be detected by X-ray film exposure or chemiluminescence imaging.
Caveat
1. Please wear gloves and use clean equipment such as tweezers during the contact with the membrane to avoid protein contamination and high background.
2. Under the condition of avoiding light, the prepared working solution of chemiluminescence detection substrate can be stored stably at room temperature for 8 hours. Sunlight or other strong light may affect the working solution, so avoid prolonged exposure to strong light. Normal laboratory lighting for a short period of time does not affect the use of the working solution.
3. Aladdin Reagent offers a wide range of membranes for protein transfer, containment solutions, primary antibodies, enzyme-labeled secondary antibodies, buffers, etc. For details, please check the company's website.
Procedure
1. After incubation of the secondary antibody, the blotting membrane is washed thoroughly.
2. According to the required amount, eECL-A and eECL-B are mixed in equal volumes at a ratio of 1:1, and prepared as a chemiluminescence detection substrate working solution (about 1m working solution is used for an 8cm×6cm membrane).
3. Discard the washing buffer, add the luminescent substrate working solution dropwise onto the blotting membrane, make sure the working solution covers the whole membrane, and incubate for 3-5 minutes at room temperature.
4. Pipette off excess luminescent substrate working solution and place the blotting membrane between two layers of clean plastic film, this process should be completed carefully to avoid air bubbles between the membrane and the membrane.
5. X-ray film exposure is performed in a dark room, or the membrane is placed inside a chemiluminescence imager and tested according to the instrument instructions.
Schedules
|
위험성, 취급, 보관 및 규제 준수를 포괄하는 종합 문서.
<<<<<<< HEAD SDS 다운로드 → ======= SDS 다운로드 → >>>>>>> release248-p3Find and download the COA for your product by matching the lot number on the packaging.
| Lot Number | Certificate Type | 날짜 | 항목 |
|---|---|---|---|
| Certificate of Analysis | Mar 15, 2026 | E665966 | |
| Certificate of Analysis | Feb 10, 2026 | E665966 |