eECL Western Blot Kit

Cat. No.: E665966
주문 가능
★
크기
USA
독일 (EU)*
가격
수량
250ml
E665966-250ml
US 주문제작 · 2–4주 ·
—

US$427.90

US$499.90
저장 US$72.00 (14.40%)
50ml
E665966-50ml
US 주문제작 · 2–4주 ·
—

US$110.90

US$129.90
저장 US$19.00 (14.63%)
Enter a quantity for the sizes you want to add.
🧪
이 등급을 선택하는 이유

최소한의 기준선 간섭이 필요한 민감한 크로마토그래피 및 분석 워크플로우용.

🌡

보관 및 배송

Store at 2-8°C,Protected from light Wet ice 출고. 정확한 사양은 로트별 COA를 확인하세요.

📋

품질 문서

SDS, COA, 데이터시트, 사양서를 다운로드할 수 있습니다. 로트별 COA는 로트 번호 조회를 통해 확인할 수 있습니다.

📚

문헌적 근거

크로마토그래피, 유기 합성 및 교차 커플링 반응 분야의 동료 심사 논문 0편에서 인용되었습니다.

개요

Product content

E665966Component50 mL250 mLStorage
E665966AeECL-A (Luminol Enhancer)
25 mL 125 mL2-8℃.Protect from light.
E665966BeECL-B (Peroxide) 25 mL 125 mL2-8℃.Protect from light.

Products

The High Sensitivity Chemiluminescent Assay is a highly sensitive and enhanced assay for use with horseradish peroxidase (HRP) in immunoblotting experiments. It is based on a new generation of enhanced chemiluminescent substrate, which is catalyzed by HRP to emit light, and can be used to detect biological macromolecules such as proteins immobilized on membranes. The high sensitivity enables the detection of pg-level antigens with a strong and long-lasting luminescence signal, which can be detected by X-ray film exposure or chemiluminescence imaging.

Caveat

1. Please wear gloves and use clean equipment such as tweezers during the contact with the membrane to avoid protein contamination and high background.

2. Under the condition of avoiding light, the prepared working solution of chemiluminescence detection substrate can be stored stably at room temperature for 8 hours. Sunlight or other strong light may affect the working solution, so avoid prolonged exposure to strong light. Normal laboratory lighting for a short period of time does not affect the use of the working solution.

3. Aladdin Reagent offers a wide range of membranes for protein transfer, containment solutions, primary antibodies, enzyme-labeled secondary antibodies, buffers, etc. For details, please check the company's website.

Procedure

1. After incubation of the secondary antibody, the blotting membrane is washed thoroughly.

2. According to the required amount, eECL-A and eECL-B are mixed in equal volumes at a ratio of 1:1, and prepared as a chemiluminescence detection substrate working solution (about 1m working solution is used for an 8cm×6cm membrane).

3. Discard the washing buffer, add the luminescent substrate working solution dropwise onto the blotting membrane, make sure the working solution covers the whole membrane, and incubate for 3-5 minutes at room temperature.

4. Pipette off excess luminescent substrate working solution and place the blotting membrane between two layers of clean plastic film, this process should be completed carefully to avoid air bubbles between the membrane and the membrane.

5. X-ray film exposure is performed in a dark room, or the membrane is placed inside a chemiluminescence imager and tested according to the instrument instructions.

Schedules

concern

Possible causes

cure

Film reversal (white stripes, black background)

)

 

Excess HRP in the system

 

 

Dilute the HRP marker at least 10-fold.

Brown or yellow bands appear on the membrane

 

 

Strong glow seen in dark room

 

 

Short duration of light signal

 

 

 

 

Weak or no signal

Excessive HRP in the luminescent reaction system, eliminating Excessive substrate depletion, causing rapid signal reduction

 

Dilute the HRP marker at least 10-fold.

 

Insufficient amount of antigen/antibody

Increased antigen/antibody usage

 

Low protein transfer rate

Optimization of the transfer system

 

 

 

high context

Excess HRP in the system

Dilute the HRP marker at least 10-fold.

 

insufficiently closed

Optimization of closure procedures

 

Poor choice of containment reagents

Select another containment reagent

 

Inadequate rinsing

Increase rinsing time, frequency

 

overexposure

Reduced exposure time

 

High antigen/antibody concentration

Reduce the concentration of antigen/antibody used

 

Protein bands are punctate

Protein transfer failure

Optimizing the transfer process

 

Membrane not in equilibrium

Handle the membrane according to the instructions

 

Air bubbles between film and membrane

Remove all air bubbles before exposure

Presence of non-specific bands

(high background, short signal duration)

 

Too much HRP in the system

 

Dilution of HRP markers

Presence of non-specific bands

(background clean signal maintenance time normal)

Excessive use of monoclonal antibody

Further dilution of primary antibody

 

SDS leads to non-specific binding

Avoid using SDS during experiments

보관 및 배송
보관 조건
Store at 2-8°C,Protected from light
배송
Wet ice

문서

📋 안전 데이터 시트(SDS)

위험성, 취급, 보관 및 규제 준수를 포괄하는 종합 문서.

<<<<<<< HEAD SDS 다운로드 → ======= SDS 다운로드 → >>>>>>> release248-p3

✅ 분석 성적서(COA)

로트별 품질 데이터. 로트 번호를 입력하여 정확한 COA를 확인하세요.

COA 조회 →

📊 데이터시트

제품 사양 및 응용 분야에 대한 빠른 참조 요약.

데이터시트 보기 →

🔬 사양서

이 등급의 전체 품질 특성 및 합격 기준.

사양서 보기 →

고급 데이터

인증서(CoA, COO, BSE/TSE 및 분석 차트)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

2 results found

Lot NumberCertificate Type날짜항목
ZJ25F0521893ZJ25F0521893Certificate of AnalysisMar 15, 2026 E665966
ZJ25F0420894ZJ25F0420894Certificate of AnalysisFeb 10, 2026 E665966
자주 묻는 질문과 기사
솔루션 계산기
리뷰

고객 리뷰

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.