Electrolytic Decalcifying Solution (Formic Acid Method) - BioReagent , CAS No.3047612-66-5

CAS: 3047612-66-5 Cat. No.: E1525467
주문 가능
등급 & 순도 BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
Synonyms
Electrolytic Decalcification Buffer (Formic Acid Method)
Storage
Room temperature
Shipped In
Normal
Application
952
★
크기
USA
독일 (EU)*
가격
수량
500ml
E1525467-500ml
US 주문제작 · 2–4주 ·
—
US$59.90
Enter a quantity for the sizes you want to add.
🧪
이 등급을 선택하는 이유

BioReagent BioReagent 최소한의 기준선 간섭이 필요한 민감한 크로마토그래피 및 분석 워크플로우용.

🌡

보관 및 배송

Room temperature Normal 출고. 정확한 사양은 로트별 COA를 확인하세요.

📋

품질 문서

SDS, COA, 데이터시트, 사양서를 다운로드할 수 있습니다. 로트별 COA는 로트 번호 조회를 통해 확인할 수 있습니다.

📚

문헌적 근거

크로마토그래피, 유기 합성 및 교차 커플링 반응 분야의 동료 심사 논문 0편에서 인용되었습니다.

개요

When certain tissues contain bone substance or calcified lesions during tissue sectioning, calcium-containing tissues cannot be directly embedded in paraffin for sectioning. This is attributed to the density difference between calcium and paraffin, which makes it difficult to obtain intact sections.For calcium-containing tissues, decalcification is preferably performed after fixation, or fixation and decalcification may be carried out simultaneously, followed by subsequent procedures including dehydration, clearing, wax impregnation, embedding and sectioning.

A variety of decalcifying reagents are available, including organic acids, inorganic acids, ethylenediaminetetraacetic acid (EDTA) and electrolytic decalcification methods. Among organic acids, formic acid and acetic acid are suitable for decalcification of bone marrow tissues.

 

Electrolytic Decalcifying Solution is mainly composed of formic acid and dilute acid.Advantages: ① Rapid decalcification speed; ② Applicable to decalcification of most types of tissues.

Disadvantages: ① It may cause certain damage to tissues; ② Alkali treatment with sodium sulfate solution is required after decalcification.This reagent is intended solely for scientific research and shall not be used for clinical diagnosis or other purposes.

 

Materials to be Prepared by User:

1. PBS

2. Distilled water

3. Thermostatic water bath

4. 5% Sodium Sulfate Solution

 

Operating Procedures (For Reference Only):

1. When decalcifying bone tissues, the sampled tissue should not be too thick, with a recommended thickness of approximately 5 mm.

2. After tissue fixation, rinse the sample with PBS 3 times, 20 minutes each time.

3. Rinse the tissue with distilled water 3 times, 20 minutes each time.

4. Assemble the electrolytic device: Take a platinum wire, wrap one end of the wire around the specimen and place it on one side of the container bottom, then connect the other end of the platinum wire to the positive electrode of the power supply. On the opposite side of the container, insert the lower end of a steel sheet or carbon rod into the solution, and connect its upper part to the negative electrode of the power supply. Place an insulated organic glass plate between the positive and negative electrodes to prevent electrical conduction caused by electrode contact.

5. Add 150~200 mL Electrolytic Decalcification Solution and place the container in a thermostatic water bath at 37~45 ℃. A 6 V direct current power supply is generally used; the voltage can be adjusted to 8~10 V if a rectifier is equipped. Electrolysis normally lasts 10 minutes to 3 hours, and the duration can be extended to 6~8 hours for compact bone.

6. Rinse the sample with running tap water for several hours.

7. Perform alkali treatment by immersing the sample in 5% Sodium Sulfate Solution.

8. Conduct routine dehydration and embedding.

 

Precautions:

1. For bone tissue blocks with a thickness of 5 mm, the decalcification period is generally 10 min to 3 h.

2. Complete decalcification is required to avoid insufficient or excessive decalcification. The decalcification degree shall be controlled to ensure no adverse impact on tissue sectioning while minimizing decalcification duration, so as to prevent tissue damage caused by overlong decalcification.

3. Bone tissue shall be fixed prior to decalcification, or fixation and decalcification shall be conducted concurrently. Decalcification before fixation is prohibited to reduce tissue damage.

4. Check the decalcification progress at regular intervals. Excessive decalcification will aggravate tissue damage and compromise staining results.

5. Wear a lab coat and disposable gloves during operation for personal safety and health.

사양

동의어
Electrolytic Decalcification Buffer (Formic Acid Method)
사양 및 순도
BioReagent
안정성 및 스토리지
Store at room temperature long term (12 months).
보관 조건
Room temperature
배송
Normal
등급
BioReagent
Product Line
생물 제품

문서

📋 안전 데이터 시트(SDS)

위험성, 취급, 보관 및 규제 준수를 포괄하는 종합 문서.

<<<<<<< HEAD SDS 다운로드 → ======= SDS 다운로드 → >>>>>>> release248-p3

✅ 분석 성적서(COA)

로트별 품질 데이터. 로트 번호를 입력하여 정확한 COA를 확인하세요.

COA 조회 →

📊 데이터시트

제품 사양 및 응용 분야에 대한 빠른 참조 요약.

데이터시트 보기 →

🔬 사양서

이 등급의 전체 품질 특성 및 합격 기준.

사양서 보기 →

고급 데이터

인증서(CoA, COO, BSE/TSE 및 분석 차트)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate Type날짜항목
ZJ26F0939209ZJ26F0939209Certificate of AnalysisSep 15, 2026 E1525467
자주 묻는 질문과 기사
솔루션 계산기
리뷰

고객 리뷰

자주 묻는 질문

What does BioReagent mean?
BioReagent indicates that the product has been processed and tested for biological and biochemical applications. Specifications may include endotoxin limits, microbial controls, sterility, low DNase/RNase/protease activity, and verified biological activity where relevant.
How should this product be stored?
Store at room temperature.
How is this product shipped?
This product ships under standard ambient conditions. No temperature-controlled packaging is required.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 62625-28-9, the molecular formula is C19H9Br4O5S, and the molecular weight is 668.953 g/mol.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

등급 선택에 도움이 필요하신가요?

당사의 등급 선택 가이드는 카탈로그의 모든 변형 제품에 대해 순도, 안정제 상태 및 용도 적합성을 다룹니다.

BioReagent 등급 가이드 보기 →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.