Universal Cell Separation Medium - BioReagent, Sterile, Ready-to-use

Cat. No.: U1527595
주문 가능
등급 & 순도 BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. Ready-to-use ? Ready-to-use — supplied pre-formulated at working concentration, no prep needed. Use to save time and reduce pipetting/dilution errors. Sterile ? Sterile grade — processed and verified free of viable microorganisms. Use directly in aseptic procedures and cell culture without further sterilization.
Synonyms
General Cell Separation Medium
Storage
Room temperature
Shipped In
Normal
Application
Cell Culture
★
크기
USA
독일 (EU)*
가격
수량
100ml
U1527595-100ml
주문제작 · 8~12주
US$309.90
500ml
U1527595-500ml
주문제작 · 8~12주
US$1,099.90
Enter a quantity for the sizes you want to add.
🧪
이 등급을 선택하는 이유

BioReagent, Sterile, Ready-to-use BioReagent,바로 사용 가능,불임 최소한의 기준선 간섭이 필요한 민감한 크로마토그래피 및 분석 워크플로우용.

🌡

보관 및 배송

Room temperature Normal 출고. 정확한 사양은 로트별 COA를 확인하세요.

📋

품질 문서

SDS, COA, 데이터시트, 사양서를 다운로드할 수 있습니다. 로트별 COA는 로트 번호 조회를 통해 확인할 수 있습니다.

📚

문헌적 근거

크로마토그래피, 유기 합성 및 교차 커플링 반응 분야의 동료 심사 논문 0편에서 인용되었습니다.

개요

Is it sterile: Yes

Universal Cell Separation Medium is a fully validated density gradient centrifugation medium, suitable for the separation of cells, viruses, and subcellular particles. Based on well-established density gradient centrifugation technology, this product enables gentle, rapid, and efficient separation of a wide variety of cells, viruses, and subcellular components within the density range of 1.0–1.3 g/mL, and is applicable to most biological particle separation experiments with sedimentation coefficients greater than 60S.

The core component of this product is polyvinylpyrrolidone (PVP)-coated modified silica gel particles, with a particle size of 15–30 nm and a free PVP content of only 1%–2%, ensuring a stable and reliable formulation. Due to the inherent size variation of silica gel particles, differential sedimentation occurs during centrifugation, spontaneously generating a continuous isotonic density gradient. The experimental procedure is flexible and convenient: density gradients can be prepared using a gradient mixer or high-speed centrifuge; alternatively, the sample can be pre-mixed with the medium, allowing the gradient to form in situ and achieving both gradient establishment and sample separation in a single step. Target components can be obtained in one operation, effectively simplifying the experimental workflow and improving efficiency.

Product Applications

This product is suitable for processing biological samples such as blood and tissues. It efficiently performs the separation, purification, and enrichment of cells, bacteria, viruses, organelles, and various subcellular components. It also effectively separates intact viable cells from damaged cells and cellular debris.

Product Features

● Excellent Activity Protection: Low viscosity, non-toxic at isotonic conditions, high biocompatibility. Does not penetrate biological membranes, does not adhere to cells, and effectively preserves the density and viability of biological particles throughout the separation process.

● Convenient and Efficient Use: Spontaneously forms a continuous density gradient upon centrifugation. Supports large-volume sample processing with simple operation and short processing time.

● Broad Applicability: Compatible with a wide range of commonly used buffers and culture media, allowing flexible preparation of density gradients within the range of 1.0–1.3 g/mL.

● Stable and Reliable Performance: Optimized formulation with stringent quality control. Exhibits stable physicochemical properties. The stock solution can be repeatedly autoclaved, ensuring excellent experimental reproducibility.

Physical Properties and Specifications

● Appearance: Colorless to light yellow liquid

● Density: 1.130 ± 0.005 g/mL

● Osmolality: max. 25 mOsm/kg·H₂O

● Conductivity: max. 100 mS/m

● pH: 9.0 ± 0.5

● Viscosity: max. 15 cP

Instructions (For Reference Only)

1. Preparation of Density Gradient Medium

This product is based on the principle of density gradient centrifugation for sample separation. Separation is achieved by exploiting the differential sedimentation rates of various cells and particles in media of different densities. Therefore, the accuracy of the working solution density is the key factor ensuring successful separation. In addition to precise density control, appropriate osmolality must be maintained to preserve the structure and viability of the sample to be separated.

Universal Cell Separation Medium performs optimally in balanced salt solutions, physiological saline, or 0.25 M sucrose solutions. For cell samples, separation can be performed in gradients prepared with balanced salt solutions, cell culture media, or NaCl solutions. For subcellular components or viruses, which tend to aggregate in salt-containing environments, gradients prepared with sucrose solutions are recommended.

Note: When preparing gradients, you may directly follow the volume calculated in Step 1.1, mix the appropriate volumes of each solution to obtain the desired density, and then proceed to Step 1.3 for gradient preparation. Alternatively, you may first prepare an isotonic stock solution according to Step 1.2, dilute it with the isotonic solution to the desired density, and then proceed to Step 1.3 for gradient preparation.

1.1 One-Step Dilution (Direct Preparation of Target Working Solution)

(1) Determine the target density and volume of the working solution based on the target separation components. Then calculate the required volumes of undiluted Universal Cell Separation Medium, diluent, and distilled water using the following formula:

V₀ = V × (ρ − 0.1ρ₁₀ − 0.9) / (ρ₀ − 1)

V₀ = Volume of undiluted Universal Cell Separation Medium (mL)

V = Total volume of target working solution (mL)

ρ = Target density of working solution (g/mL)

ρ₀ = Density of undiluted Universal Cell Separation Medium (1.130 g/mL)

ρ₁₀ = Density of the diluent (density of 1.5 M NaCl solution is approximately 1.058 g/mL)

(2) After calculating V₀ using the above formula, measure V/10 of the diluent (1.5 M NaCl solution or 2.5 M sucrose solution). Mix the Universal Cell Separation Medium and the diluent thoroughly, then bring the final volume to V with distilled water.

Example: To prepare 100 mL of target working solution with a density of 1.07 g/mL using 1.5 M NaCl solution as the diluent:

ρ = 1.07 g/mL, ρ₀ = 1.130 g/mL, ρ₁₀ = 1.058 g/mL, V = 100 mL

Substituting into the formula: V₀ = 100 × (1.07 − 0.1 × 1.058 − 0.9) / (1.130 − 1) = 49.4 mL

Procedure: Mix 49.4 mL of Universal Cell Separation Medium with 10 mL of 1.5 M NaCl solution, then add distilled water to a final volume of 100 mL to obtain the target working solution.

1.3 Preformed Density Gradient Preparation:

Starting from the bottom to the top, layer the solutions in order of decreasing density (from high to low). Using a pipette tip or syringe, position it against the tube wall and allow the liquid to flow down naturally and slowly. Ensure that the upper layer (low density) does not splash into the lower layer (high density) or mix at the interface, so as to form a clean gradient.

Note: The tube wall may be pre-rinsed with FBS, and excess serum then removed. This pretreatment allows the layered separation solutions to flow smoothly along the tube wall, resulting in well-defined interfaces.

2. Density Gradient Centrifugation

The appropriate centrifugation method can be selected according to experimental requirements.

2.1 High-Speed Angle-Rotor Centrifugation (Spontaneous Gradient Formation):

Universal Cell Separation Medium will spontaneously form a continuous density gradient from the bottom to the top of the tube after centrifugation at approximately 10,000 × g (prepared in 0.15 M physiological saline) or 25,000 × g (prepared in 0.25 M sucrose solution) for 15 minutes. In this method, the sample can be uniformly mixed with the Universal Cell Separation Medium prior to centrifugation. During centrifugation, sample particles will be stratified within the spontaneously formed gradient according to their densities, and will ultimately become concentrated at the position where their density equals that of the surrounding medium, forming distinct isopycnic bands. This method is suitable for the efficient separation of subcellular particles or virus samples.

2.2 Low-Speed Swing-Bucket Rotor Centrifugation (Dependent on Preformed Gradients):

For shear-sensitive samples such as viable cells, low-speed centrifugation (e.g., 400 × g) using a swing-bucket rotor is recommended. This method typically relies on preformed continuous or discontinuous density gradients (Step 1.3). The sample can be gently layered onto the separation medium using a pipette tip or syringe before centrifugation. The centrifugation should be performed with slow acceleration and deceleration settings (e.g., set to grade 0 or 1) for 20–30 minutes. This approach effectively maintains gradient stability and prevents the already separated cell bands from remixing due to fluid disturbance, thereby allowing cells to migrate gently to their isopycnic positions, resulting in higher cell viability and recovery rates.

3. Harvesting Target Components

After density gradient centrifugation, the system forms a continuous density gradient (approximately 1.0–1.3 g/mL), in which various cells or particles will float or sediment to isopycnic bands where their own density (i.e., buoyant density) equals that of the surrounding medium. The target components can be obtained by carefully aspirating the target layer bands.

The typical densities and distribution positions of different cells and subcellular components in Universal Cell Separation Medium are provided in the table below for reference only. Please note that variations may exist among samples from different species.

CategorySample TypeBuoyant Density (g/mL)Position After SeparationRemarks
CellsPlatelet<1.04Upper layer or floating on liquid surfaceLightest, often floats on the surface
CellsLymphocyte1.055-1.065Middle layer, interfaceOften aggregates at the transparent band
CellsMonocyte1.060-1.068Middle-lower layerLocated below lymphocytes
CellsNeutrophil1.080-1.090Lower layerDirectly above red blood cells
CellsErythrocyte>1.09Bottom pelletHighest density, completely sediments to the bottom
Subcellular ComponentsCytoplasm<1.05Upper layer or floatingLightest soluble fraction
Subcellular ComponentsMicrosome1.09-1.12Middle layerBroad distribution
Subcellular ComponentsLysosome1.12-1.15Middle-lower layerOften located above mitochondria
Subcellular ComponentsMitochondria1.17-1.20Lower layerMainly concentrated in higher density region
Subcellular ComponentsNucleus>1.20Very bottomHighest density among nuclei

4. Washing

Since Universal Cell Separation Medium is non-cytotoxic and does not adhere to cell membranes, it is generally not necessary to remove it. Cells can be directly transferred to culture systems, viruses can be directly used for infection, and organelles can be directly applied to functional studies. If removal is required, washing can be performed according to the following methods.

(1) Cell samples: Gently wash with 5 volumes of pre-chilled physiological saline or PBS. Centrifuge at 200–400 × g for 2–10 minutes at 4°C. Discard the supernatant. Repeat washing 2–3 times if necessary, and collect the cell pellet.

(2) Subcellular components: After gentle washing with 5 volumes of pre-chilled physiological saline or PBS, centrifuge at 10,000–20,000 × g for 10–30 minutes at 4°C. Carefully discard the supernatant and collect the pellet.

Note: The specific centrifugal force depends on the target subcellular components.

(3) For viruses, exosomes, or smaller particles: For undiluted samples, centrifuge at 100,000 × g for 120 minutes (swing-bucket rotor) or 90 minutes (angle rotor) at 4°C to pellet the medium components from the Universal Cell Separation Medium, and collect the supernatant.

(4) Washing can also be performed by gel filtration, ion exchange chromatography, ultrafiltration centrifugation, or dialysis according to published protocols.

5. Reference Data: Density Determination of Universal Cell Separation Medium Gradients

A refractometer can be used to measure the density of fractionated Universal Cell Separation Medium solutions. The refractive index shows a linear correlation with the density of Universal Cell Separation Medium solutions. For reference, the density and refractive index of dilution series of Universal Cell Separation Medium in sucrose and sodium chloride solutions at 20°C are provided in the table below.

Density in Sucrose Solution (g/mL)Refractive Index in Sucrose SolutionDensity in NaCl Solution (g/mL)Refractive Index in NaCl Solution
1.03451.34571.00851.335
1.04841.34781.02431.3372
1.06181.34991.04031.3399
1.07651.35181.05581.3423
1.09031.35411.07131.3449
1.1041.35611.08691.347
1.1181.35821.10291.3493
1.13191.361.11891.3519
1.14611.36261.13051.3534
1.15471.36381.15131.3569

Precautions

1.After centrifugation, this product may leave residual silica precipitates on the tube wall and bottom, which are difficult to remove once dried. Therefore, consumables should be cleaned immediately after the experiment. Polycarbonate (PC) centrifuge tubes are recommended.

2.This product is stable within the pH range of 5.5–10.0. Conditions such as pH < 5.5, the presence of divalent cations (e.g., Ca²⁺, Mg²⁺), or high temperatures may cause colloidal silica gelation and destabilization. Experimental systems should avoid low pH, high salt, and divalent ion-containing environments.

3.Aggregation of colloidal silica upon long-term storage is an inherent property. In some batches, aggregates may be observed as slight precipitates at the bottom of the container or as a faint whitish band at a density of 1.04–1.05 g/mL. This band may form during gradient preparation centrifugation or low-speed centrifugation of preformed gradients. Silica aggregates do not interfere with biological particle separation, as the buoyant density of most cells and organelles in the separation medium is greater than 1.05 g/mL. For routine cell, virus, and organelle separation experiments, the impact of silica aggregates from the gradient medium is negligible.

4.This product is sterile-packaged. Strict aseptic techniques must be followed during operation to prevent contamination. If re-sterilization is required, only the stock solution can be autoclaved at 121°C for 30 minutes. Pre-mixed working solutions containing salts or sucrose should not be autoclaved, as this may induce gelation or caramelization; filtration through 0.22 μm membrane filters is also not recommended. During sterilization, minimize contact between the liquid and air to avoid solid particle precipitation at the liquid-air interface; narrow-mouth containers are recommended. If particles form, they can be removed by filtration through a 0.45 μm filter or by low-speed centrifugation at 500 × g for 5 minutes. If liquid evaporates during sterilization, the original density can be restored by adding the corresponding volume of distilled water.

5.Laboratory coats and disposable gloves should be worn during operation. Ensure proper safety protection.

6.This product is for research use only.

사양

동의어
General Cell Separation Medium
사양 및 순도
BioReagent, Sterile, Ready-to-use
안정성 및 스토리지
Store at RT long term (60 months).
보관 조건
Room temperature
배송
Normal
등급
BioReagent, 바로 사용 가능, 불임
Product Line
생물 제품

문서

📋 안전 데이터 시트(SDS)

위험성, 취급, 보관 및 규제 준수를 포괄하는 종합 문서.

<<<<<<< HEAD SDS 다운로드 → ======= SDS 다운로드 → >>>>>>> release248-p3

✅ 분석 성적서(COA)

로트별 품질 데이터. 로트 번호를 입력하여 정확한 COA를 확인하세요.

COA 조회 →

📊 데이터시트

제품 사양 및 응용 분야에 대한 빠른 참조 요약.

데이터시트 보기 →

🔬 사양서

이 등급의 전체 품질 특성 및 합격 기준.

사양서 보기 →

고급 데이터

인증서(CoA, COO, BSE/TSE 및 분석 차트)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
자주 묻는 질문과 기사
솔루션 계산기
리뷰

고객 리뷰

Application Protocols

Validated/tested application details (e.g., sample volumes, dilution factors, centrifugation g-forces and times, and interface collection steps) are not specified for this item.

General framework (literature; not item-specific):

  • Prepare sample: Dilute anticoagulated blood with an appropriate isotonic buffer if required by your SOP.
  • Layering: Carefully overlay the sample onto the separation medium to preserve a sharp interface.
  • Centrifugation: Spin at an RCF and time suitable for your target cell class; use minimal braking.
  • Harvest: Aspirate the desired interface fraction using sterile technique; transfer to a clean tube.
  • Wash: Dilute with buffer and centrifuge to remove residual medium; repeat as needed.
  • Count/assess: Determine yield and viability (e.g., trypan blue or dye-exclusion method) and proceed to downstream applications.

For lot-specific guidance and any manufacturer-recommended parameters, consult the CoA/Spec Sheet.

Biological Roles

This product is an enabling reagent for handling biological samples; it is not a biomolecule with intrinsic physiological function. Its role is operational—facilitating selective partitioning of cells based on physical properties.

General context (literature; not item-specific):

  • Density-based separations exploit differences in cell buoyant density, size, and morphology to enrich target populations (e.g., PBMCs) while depleting erythrocytes and granulocytes.
  • Properly formulated media are typically isotonic and compatible with mammalian cells to preserve viability through the centrifugation step.
  • After separation, cells are collected from defined interfaces and washed free of the medium to support downstream applications (flow cytometry, culture, nucleic acid extraction, and functional assays).
  • The operational outcome depends on sample type (whole blood, cord blood, bone marrow, tissue digests) and parameters such as RCF, time, temperature, and sample dilution.

For this SKU: Specific density, osmolality, or target cell recommendations are not specified in the Product Data. Users should consult the product CoA/SDS and validate recovery, viability, and purity under their laboratory conditions.

Buffer Applications

This product is a cell separation medium, not a general-purpose buffering agent. While such media are often aqueous and may include salts or buffering components, item-specific buffer composition and pH range are not specified for this SKU.

Practical guidance:

  • Use your standard wash buffer (e.g., PBS + protein/EDTA per your SOP) after separation to remove residual medium; optimize based on your downstream application. Composition should be validated empirically.
  • If pH control is critical during processing, monitor with a calibrated pH meter and adjust your ancillary buffers accordingly. Do not modify the separation medium unless the manufacturer explicitly supports it.
Green Alternatives

As a sterile, ready-to-use life-science formulation, conventional “green solvent” metrics (e.g., VOC content, solvent replacement) are not the primary consideration. Nevertheless, environmental and safety aspects can be optimized operationally.

  • Considerations (general, not item-specific):
    • Choose media that are aqueous, isotonic, and free of volatile organic solvents to minimize flammability and emissions.
    • Evaluate preservative systems and disposal requirements, especially if mixed with biological materials.
    • Minimize single-use plastics by aliquoting judiciously and matching container size to experimental scale.

Comparison (literature; not item-specific to this SKU):

  • Polymer-based density media vs. iodinated small-molecule media:
    • Polymer-based: Typically low volatility, established workflows, may require thorough washing to remove polymers from cells.
    • Iodinated media (e.g., iodixanol-type): Tunable density, iso-osmotic gradients, often high purity; disposal may require specific handling due to halogen content.

Recommendations:

  • Perform process mapping to reduce reagent consumption and waste.
  • Use validated closed-system processing (where possible) to reduce contamination risk and product losses.
  • Follow institutional guidelines for environmentally responsible disposal of biohazard-containing liquids.
Pharmaceutical Uses
  • Regulatory status: Supplied as a research-use-only BioReagent. It is not certified for clinical diagnostic or therapeutic manufacturing as provided.
  • Formulation/excipient roles: Not applicable; this product is intended as a laboratory cell separation reagent, not as a drug excipient.
  • Process development note (general): In bioprocess R&D, density-based separations may be explored for upstream sample cleanup or leukopak processing. Transition to clinical/GMP use requires vendor qualification, detailed composition disclosure, validated removal from final cell product, and process-specific comparability studies.
  • Pharmacopeial monographs: None cited for this SKU; consult internal QA if a pharmacopeial grade is required.
  • Trace impurities, bioburden, endotoxin limits: Not specified for this item; refer to CoA/Spec Sheet.
Physical Properties

Item-specific physical constants are not provided in the Product Data.

  • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Density, osmolarity, refractive index, pH: Not specified for this item; refer to CoA/Spec Sheet.
  • Boiling/melting point, vapor pressure, logP: Not applicable for a water-based laboratory medium in routine use; item-specific values are not provided.

Context (literature/general for cell separation media; not item-specific):

  • Such media are commonly aqueous, isotonic formulations designed to maintain cell viability during centrifugation.
  • Density-gradient media for mononuclear cell isolation often target an operational density near ~1.06–1.09 g/mL (literature), but the exact target for this product is not specified.
  • Typical usage temperature: ambient (room temperature), unless otherwise stated by the manufacturer; this item lists storage at room temperature.

Always consult the lot-specific CoA for numerical specifications pertinent to your application (e.g., density window, osmolality, conductivity, and ionic strength) before method development.

Quality and Grades
  • Item-specific grade: BioReagent, Ready-to-use, Sterile (per Product Data).
    • BioReagent: Suitable for laboratory research workflows; not certified for clinical diagnostic or GMP therapeutic use unless otherwise validated by the user’s quality system.
    • Ready-to-use: Formulation is supplied at use concentration—no dilution or activation step implied unless directed in the CoA or protocol.
    • Sterile: Manufactured/filtered to be free of viable microorganisms at release. Maintain aseptic technique after opening to preserve sterility.
  • What this means practically:
    • Reduced prep time and variability compared to in-house formulations.
    • Lot-to-lot reproducibility supported by manufacturer QC; consult CoA for specific QC metrics (e.g., sterility test method, endotoxin limit, density/osmolality if applicable). Item-specific numeric limits are not provided here.
  • Stabilizers/preservatives: Not specified for this item; refer to CoA/Spec Sheet. Presence or absence of preservatives affects open-bottle shelf-life and compatibility with sensitive cells.
  • UV/absorbance profile, metal/ionic content: Not specified for this item; refer to CoA/Spec Sheet.
  • Recommendation: For regulated workflows, perform incoming qualification (verification of density, pH, osmolality, endotoxin/bioburden, and functional cell recovery) aligned to your internal SOPs.
Reaction and Applications

This product is not intended for chemical synthesis or catalytic reactions. Instead, it serves as a laboratory reagent for cell separation workflows.

  • Application context (general, literature):
    • Enrichment of peripheral blood mononuclear cells (PBMCs), isolation of mononuclear fractions from whole blood or buffy coat, and preliminary cleanup of cell suspensions prior to downstream analysis.
    • Removal of erythrocytes, granulocytes, platelets, and debris depending on density and centrifugation conditions.
  • Practical tips (general, not item-specific):
    • Use freshly mixed blood or appropriately anticoagulated samples to minimize clumping; avoid hemolysis.
    • Layer diluted blood carefully over the medium to maintain a sharp interface; minimize turbulence.
    • Centrifuge with brake off (or low deceleration) during separation steps to preserve gradient interfaces.
    • Maintain room temperature if required by the medium; temperature shifts can alter density and viscosity.
    • Collect interphase with sterile, narrow-bore pipettes; wash cells gently to remove residual medium before functional assays.
  • For this SKU specifically: Detailed rotor speed, RCF, time, and interface identification guidance are not specified; consult the CoA/Spec Sheet and validate in your system.
Reaction Conditions

Not applicable to chemical reactions. For laboratory use, operating conditions relate to cell separation protocols rather than chemical kinetics.

General procedural parameters (literature guidance; not item-specific):

  • Temperature: Often room temperature; avoid large temperature swings that can affect density/viscosity and cell viability.
  • Centrifugation: Separation steps typically employ carefully controlled RCF (g), time, and acceleration/deceleration profiles with brakes off or reduced during gradient resolution.
  • Sample preparation: Gentle dilution with a suitable isotonic buffer and careful overlay onto the medium to maintain phase boundaries.

For this SKU, specific RCF, rotor type, time, and interface collection instructions are not specified. Optimize empirically for your instrument, sample type, and target cell population.

Safety and Handling
  • GHS classification, signal word, pictograms, and H-statements: Not specified for this item; refer to the product SDS for authoritative safety data.
  • General precautions (good laboratory practice):
    • Wear appropriate PPE: lab coat, safety glasses, and suitable gloves.
    • Avoid microbial contamination of the sterile medium; keep containers closed when not in use and work in a biosafety cabinet if sterility must be preserved.
    • Prevent aerosol formation and splashes; wipe spills promptly with an appropriate disinfectant.
  • Incompatibilities: As a water-based life-science reagent, avoid mixing with strong oxidizers, strong acids/bases, or reactive chemicals that could compromise composition or produce hazardous byproducts. Do not autoclave unless the label explicitly supports it (can alter formulation).
  • First aid (general guidance; defer to SDS):
    • Skin/eye contact: Rinse with water for several minutes; remove contact lenses if present and easy to do; seek medical advice if irritation persists.
    • Ingestion/inhalation: Rinse mouth; move to fresh air; seek medical attention as needed.
  • Sterility handling: Use sterile pipette tips/reservoirs; do not re-enter stock bottles with non-sterile tools. Consider aliquoting into sterile tubes to minimize repeated exposure.
  • Waste: Dispose according to institutional and local regulations. If used with biological samples, treat as biohazardous waste and decontaminate accordingly.
Solvent Selection

This product is a formulated cell separation medium, not a general-purpose solvent for synthetic chemistry or chromatography.

  • Polarity/miscibility: Typically aqueous and fully miscible with water-based buffers (general literature), but item-specific composition and compatibility are not provided; verify before mixing.
  • Intended use: Density- or property-based separation of cells rather than dissolution/solvation of analytes.
  • Selection guidance:
    • Choose this medium when you require a ready-to-use, sterile solution designed for cell isolation workflows.
    • If protocol compatibility with other media (e.g., phosphate-buffered saline, culture medium, or alternative gradient media) is a concern, run small-scale pilots to confirm phase behavior and cell recovery.
  • Alternatives (contextual): Labs may also consider sucrose-based cushions, polysaccharide gradients, or iodinated density media (literature, not item-specific). Select based on target cell type, centrifugation hardware, and downstream assays.
Storage and Reconstitution
  • Storage conditions (per Product Data): Room temperature. Avoid extreme temperatures and protect from contamination. Do not freeze unless specifically allowed by the manufacturer, as freezing may alter performance.
  • Shipping: Normal conditions (per Product Data).
  • Reconstitution: Not applicable; the product is ready-to-use. Do not dilute or modify unless your validated protocol and the product documentation support it.
  • Handling to maintain sterility:
    • Open under aseptic conditions; consider aliquoting into sterile containers to reduce repeated exposure.
    • Use sterile, single-use pipette tips; avoid touching the container rim; recap promptly.
  • Stability/shelf life: Not specified for this item; refer to CoA/Spec Sheet and container label for expiration and in-use guidance.
  • Pre-use equilibration: If stored in a cool environment, allow the medium to equilibrate to room temperature before use to maintain expected physical properties during separation.
  • Post-use storage: If the bottle has been opened, store tightly capped at room temperature as indicated and record the open date; discard if turbidity, precipitate, color change, or contamination is observed.
Structure and Identity
  • Product type: Universal Cell Separation Medium (ready-to-use, sterile). This is a formulated laboratory reagent rather than a single defined small molecule.
  • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
  • SMILES / InChI / InChIKey / CAS / CID: Not specified for this item; refer to CoA/Spec Sheet.
  • Structural features: This product is typically an aqueous formulation designed for density-based separation of cells. Exact constituents (e.g., polymers, iodinated contrast agents, salts, or carbohydrates) are not provided for this SKU.
  • 2D structure description: Not applicable; the product is a mixture/formulation rather than a single discrete structure.
  • Identity confirmation: Users should rely on lot-specific CoA/SDS for composition, osmolarity, density, and pH details where applicable.
Synthetic Utility

Not applicable. This product is a biological sample processing medium, not a synthetic building block or reagent for chemical transformations. It is not typically used in organic synthesis, materials fabrication, or catalysis.

If your objective is chemical synthesis, consider selecting defined reagents or solvents tailored to your transformation and consult the appropriate product pages for detailed synthetic utility guidance.

Target Specificity

Not applicable. This product is not an antibody or affinity reagent and does not possess biochemical target specificity. It separates cells based on physical properties (e.g., buoyant density) rather than antigen recognition.

Item-specific target claims are not provided for this SKU.

등급 선택에 도움이 필요하신가요?

당사의 등급 선택 가이드는 카탈로그의 모든 변형 제품에 대해 순도, 안정제 상태 및 용도 적합성을 다룹니다.

BioReagent 등급 가이드 보기 → Ready-to-use 등급 가이드 보기 → Sterile 등급 가이드 보기 →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.