Recombinant PSMB10/MECL1 Antibody: Protocol & Usage Guide
Recombinant PSMB10/MECL1 Antibody: Protocol & Usage Guide
Recombinant PSMB10/MECL1 Antibody is a high-specificity recombinant antibody targeting the immunoproteasome catalytic subunit PSMB10 (also known as MECL1), supplied as Ab123661 with lot-to-lot concentration variation of less than 5%, making it suitable for consistent and reproducible research applications.
- Product Name
- Recombinant PSMB10/MECL1 Antibody
- SKU
- Ab123661
- Clone Number
- R08-6I5 (Supplier Clone)
- Lot-to-Lot Concentration Variation
- < 5%
- Antibody Type
- Recombinant Antibody
- Target
- PSMB10 / MECL1 (Proteasome Subunit Beta-10)
Product Overview and Target Biology
Recombinant PSMB10/MECL1 Antibody (Ab123661) is designed to detect PSMB10, also designated MECL1 (Multicatalytic Endopeptidase Complex-Like 1), a catalytic beta subunit of the immunoproteasome. The immunoproteasome is a specialized form of the 26S proteasome induced by interferon-gamma (IFN-γ) and plays a central role in MHC class I antigen presentation and immune regulation.
PSMB10 replaces the constitutive subunit PSMB7 (β2) during immunoproteasome assembly and contributes trypsin-like proteolytic activity. Its expression is upregulated in immune tissues and in cells responding to inflammatory stimuli. Research into PSMB10 is relevant to fields including autoimmunity, cancer immunology, and infectious disease.
This antibody is derived from supplier clone R08-6I5 and is manufactured to ensure a batch-to-batch concentration variation of less than 5%, supporting reproducible experimental outcomes across multiple studies.
Storage, Handling, and Formulation
To maintain the activity and integrity of Recombinant PSMB10/MECL1 Antibody, observe the following handling guidelines:
- Storage Temperature: Store at –20 °C for long-term storage. Avoid repeated freeze-thaw cycles, which can compromise antibody performance.
- Aliquoting: Upon first thaw, prepare single-use aliquots to minimize freeze-thaw events.
- Working Solution Stability: Once diluted, use prepared working solutions promptly. Keep on ice during experimental procedures.
- Avoid Contamination: Use sterile, low-protein-binding tubes and pipette tips when handling the antibody to prevent degradation or loss of material.
Always centrifuge the vial briefly before opening to consolidate the contents. Specific formulation details (buffer composition, concentration, stabilizers) should be confirmed from the product datasheet at time of purchase.
Recommended Applications and Dilution Protocol
Recombinant PSMB10/MECL1 Antibody is intended for use in standard immunological assays. Typical applications for antibodies of this class include Western Blotting (WB), Immunohistochemistry (IHC), Immunofluorescence (IF), and Enzyme-Linked Immunosorbent Assay (ELISA). Confirm validated applications from the product datasheet before use.
General Dilution Guidelines (verify with current datasheet):
- Western Blotting: Titrate starting from a 1:500–1:2000 dilution in blocking buffer. Optimize based on signal intensity and background.
- Immunohistochemistry: Begin optimization at 1:50–1:200. Antigen retrieval conditions may need to be tested empirically.
- Immunofluorescence: Suggested starting range 1:100–1:500 in appropriate diluent.
Protocol Steps for Western Blotting:
- Prepare cell or tissue lysates under denaturing conditions (e.g., RIPA buffer with protease inhibitors).
- Resolve proteins by SDS-PAGE and transfer to PVDF or nitrocellulose membrane.
- Block membrane for 1 hour at room temperature with 5% non-fat dry milk or BSA in TBST.
- Incubate with Ab123661 primary antibody at the optimized dilution overnight at 4 °C.
- Wash three times with TBST (10 minutes each), then incubate with appropriate HRP-conjugated secondary antibody.
- Detect using chemiluminescent substrate. Expected band size for PSMB10 is approximately 29 kDa (verify with datasheet).
Quality Control and Batch Consistency
The Recombinant PSMB10/MECL1 Antibody is manufactured under a quality framework ensuring that inter-lot concentration variation remains below 5%. This is a critical specification for longitudinal studies and multi-site research programs where batch reproducibility directly impacts data comparability.
As a recombinant antibody generated from a defined clone (supplier clone R08-6I5), this product offers the advantage of sequence-defined specificity, reduced lot-to-lot variability compared to polyclonal antisera, and the potential for unlimited, consistent production.
Recommended quality checks before initiating a new experiment include:
- Visual inspection of the vial for particulates or unusual color changes.
- Running a positive control lysate or tissue section known to express PSMB10 to confirm antibody activity.
- Including a negative control (antibody omission or isotype control) to assess background and non-specific binding.
Troubleshooting Common Issues
If unexpected results are obtained when using Recombinant PSMB10/MECL1 Antibody, consult the following guidance:
| Issue | Possible Cause | Suggested Action |
|---|---|---|
| No signal detected | Insufficient antigen, over-diluted antibody, or inadequate antigen retrieval | Increase antibody concentration; optimize lysis or retrieval conditions; verify target expression in your cell/tissue model |
| High background | Under-blocking, antibody concentration too high, or cross-reactivity of secondary antibody | Extend blocking time; reduce primary antibody concentration; use more stringent wash steps |
| Multiple non-specific bands (WB) | Sample degradation or non-specific binding | Ensure fresh protease inhibitors in lysis buffer; optimize antibody dilution; run shorter exposure |
| Inconsistent results between lots | Storage deviation or improper handling | Confirm storage conditions; check freeze-thaw history; run side-by-side comparison with positive control |
Frequently asked questions
What is the clone number for Ab123661 and why does it matter?
The supplier clone number for Recombinant PSMB10/MECL1 Antibody (Ab123661) is R08-6I5. Clone numbers identify the specific B-cell clone from which the antibody variable regions are derived. For recombinant antibodies, this guarantees sequence-defined and reproducible epitope recognition across all production lots, which is essential for data consistency in long-term studies.
How should I validate Recombinant PSMB10/MECL1 Antibody in my experimental system?
Begin validation by using a positive control sample known to express PSMB10, such as IFN-γ-stimulated immune cells or relevant tissue lysates. Include a negative control (antibody omission or isotype control) in parallel. Confirm the detected band or signal corresponds to the expected molecular weight of PSMB10 (approximately 29 kDa for Western blotting; verify with the current datasheet). Knockdown or knockout cell lines can be used for definitive target validation if available.
What does a lot-to-lot concentration variation of less than 5% mean for my experiments?
A lot-to-lot concentration variation of less than 5% means that the antibody concentration delivered in each new lot will deviate by no more than 5% from the stated concentration. This tight specification ensures that researchers can use the same working dilution across different lots without needing to re-optimize, which is particularly valuable in multi-lot longitudinal studies and when establishing standardized assay protocols.
Is Recombinant PSMB10/MECL1 Antibody suitable for detecting PSMB10 in non-human species?
Species cross-reactivity depends on the degree of sequence conservation in the epitope region between human and other species. This information should be confirmed from the product datasheet for Ab123661. If cross-reactivity with your species of interest is not listed, empirical testing with appropriate positive and negative controls is recommended before drawing conclusions.
References
- Abcam product reference Ab17614 — source reference for Recombinant PSMB10/MECL1 Antibody clone R08-6I5. Confirm current datasheet for validated applications, formulation, and species reactivity.
- Tanaka K. The proteasome: overview of structure and functions. Proc Jpn Acad Ser B Phys Biol Sci. 2009;85(1):12-36. General reference for immunoproteasome biology including PSMB10/MECL1. doi:10.2183/pjab.85.12
- Groettrup M, Kirk CJ, Basler M. Proteasomes in immune cells: more than peptide producers. Nat Rev Immunol. 2010;10(1):73-78. Reviews immunoproteasome subunit biology and relevance to antigen presentation. doi:10.1038/nri2687
Products are supplied for research and development use only. Not for use in humans, animals, diagnosis, or therapy.
