Annexin V-APC/DAPI Apoptosis Detection Kit - BioReagent, Biological Stain, for microscopy, Suitable for Immunofluorescence(IF), ready-to-use, high purity

Cat. No.: A1456534
DISPONIBLE À COMMANDE
QUALITÉ & PURETÉ Suitable for Immunofluorescence(IF) ? IF grade — validated for immunofluorescence with low background staining. Use to localize targets in cells/tissue by fluorescence microscopy. BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. Ready-to-use ? Ready-to-use — supplied pre-formulated at working concentration, no prep needed. Use to save time and reduce pipetting/dilution errors. Biological Stain ? Biological stain grade — dyes characterized for staining cells and tissues. Use in histology and microscopy where staining consistency matters. for Microscopy ? Microscopy grade — reagents/stains suited to sample prep and imaging. Use in microscopy where clarity and low background are needed.
★
Taille
Allemagne (EU)
USA*
Prix
Qté
20T
A1456534-20T
Sur commande · 8–12 semaines
164,78€
50T
A1456534-50T
Sur commande · 8–12 semaines
277,59€
100T
A1456534-100T
Sur commande · 8–12 semaines
433,78€
200T
A1456534-200T
Sur commande · 8–12 semaines
694,10€
Enter a quantity for the sizes you want to add.
🧪
Pourquoi cette qualité

Suitable for Immunofluorescence(IF), BioReagent, ready-to-use, Biological Stain, for microscopy Biological Stain,BioReagent,pour la microscopie,Prêt à l'emploi,Suitable for Immunofluorescence(IF) pour les flux de travail chromatographiques et analytiques sensibles nécessitant une interférence de ligne de base minimale.

🌡

Stockage & expédition

Store at 2-8°C,Protected from light Expédition Wet ice. Consultez le COA spécifique au lot pour les spécifications exactes.

📋

Documents qualité

SDS, COA, fiche technique et fiche de spécifications disponibles au téléchargement. COA spécifique au lot accessible via la recherche par numéro de lot.

📚

Preuve documentaire

Cité dans 0 publications à comité de lecture couvrant la chromatographie, la synthèse organique et les réactions de couplage croisé.

Vue d’ensemble

  Annexins are a family of calcium-dependent phospholipid-binding proteins that preferentially bind phosphatidylserine (PS). Under normal physiologic conditions, PS is predominantly located in the inner leaflet of the plasma membrane. Upon initiation of apoptosis, PS loses its asymmetric distribution across the phospholipid bilayer and is translocated to the extracellular membrane leaflet marking cells as targets of phagocytosis. Once on the outer surface of the membrane, PS can be detected by fluorescently labeled Annexin V in a calcium-dependent manner.

  In early-stage apoptosis, the plasma membrane excludes viability dyes such as 4',6-diamidino-2-phenylindole (DAPI), propidium iodide (PI), 7-AAD. These cells will stain with Annexin V but not a viability dye, thus distinguishing cells in early apoptosis. However, in late stage apoptosis, the cell membrane loses integrity thereby allowing Annexin V to also access PS in the interior of the cell. A viability dye can be used to resolve these late-stage apoptotic and necrotic cells (Annexin V, viability dye-positive) from the early-stage apoptotic cells (Annexin V positive, viability dye-negative).

This kit is suitable for the identification and enumeration of dead cells, such as apoptotic or necrotic cells, by flow cytometry.

Instruction for use

1.  Dilute 10x Binding Buffer to 1x using distilled water (1 mL 10x Binding Buffer + 9 mL ddH2O).

2.  Wash cells twice with cold PBS and then resuspend the desired amount of cells in Annexin V Binding Buffer at a concentration of 0.5-1.0x106 cells /mL.

3.  Add 5 μL of Annexin V-APC and 2 μL of DAPI staining solution to 100 μL of cell suspension.

4.  Add 100 µLof 1x Binding Buffer to each assay.  Gently vortex the cells and incubate for 10 min at RT (25°C) in the dark.

Precautions

1. Please try to avoid light when using to slow down the quenching of fluorescence.

2. DAPI Solution is toxigenic and mutagenic; handle with care.

3. Due to the calcium dependence of the Annexin V:PS interaction, it is critical to avoid buffers containing EDTA or other calcium chelators during Annexin V experiments.

Spécifications

Synonymes
Annexin V-APC/DAPI Apoptosis Kit | Annexin V-APC Assay Kit
Spécifications et pureté
Suitable for Immunofluorescence(IF), BioReagent, ready-to-use, Biological Stain, for microscopy
Grade
Biological Stain, BioReagent, pour la microscopie, Prêt à l'emploi, Suitable for Immunofluorescence(IF)
Application
Apoptosis, Flow Cytometry, IF/ICC
Sensibilité
light-sensitive
Stockage et expédition
Conditions de stockage de stockage
Store at 2-8°C,Protected from light
Expédié en
Wet ice
Stabilité et stockage
Store at 2-8℃ long term (12 months)
Contents & Storage

A1456534

Components

20 T

50 T

100 T

Storage

Quantity Per Test

A1456534A

10× Annexin V Binding Buffer

5 mL

10 mL

20 mL

2-8℃

200 μL per  0.5-1.0x105 cells

A1456534B

Annexin V-APC

100 μL

250 μL

500 μL

2-8℃. Store in the dark.

5 μL per  0.5-1.0x105 cells

A1456534C

DAPI Staining Solution

40 μL

100 μL

200 μL

2-8℃. Store in the dark.

2 μL per 0.5-1.0x105 cells

Note: The recommended number of cells to stain per test is 0.5-1.0x10⁵ cells.
Images

Annexin V-APC/DAPI Apoptosis Detection Kit (A1456534) - Flow Cytometry
Flow cytometric analysis was performed on Jurkat cells, either untreated (left panel) or treated with 2 µM camptothecin (C111281) for 16 hours (right panel), using the Annexin V-APC/DAPI Apoptosis Detection Kit (A1456534).
The cells were stained with Annexin V-APC and DAPI and then analyzed. In the untreated sample (left panel), the majority of cells were negative for both Annexin V-APC and DAPI, indicating a viable, non-apoptotic population. Following the 16-hour treatment with camptothecin (right panel), three main cell populations were identified:
1. Viable, non-apoptotic cells: Annexin V-APC negative/DAPI negative.
2. Early apoptotic cells: Annexin V-APC positive/DAPI negative.
3. Late apoptotic and dead cells: Annexin V-APC positive/DAPI positive.

Documentation

📋 Fiche de données de sécurité (FDS)

Document complet couvrant les dangers, la manipulation, le stockage et la conformité réglementaire.

<<<<<<< HEAD Télécharger la SDS → ======= Télécharger la SDS → >>>>>>> release248-p3

✅ Certificat d'analyse (COA)

Données qualité spécifiques au lot. Saisissez votre numéro de lot pour récupérer le COA exact.

Rechercher le COA →

📊 Fiche technique

Résumé de référence rapide des spécifications et applications du produit.

Voir la fiche technique →

🔬 Fiche de spécifications

Attributs de qualité complets et critères d'acceptation pour cette qualité.

Voir la fiche de spécifications →

Données avancées

Certificats (CoA, COO, BSE/TSE et tableau d'analyse)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

3 results found

Lot NumberCertificate TypeDateArticle
ZJ26F0332435ZJ26F0332435Certificate of AnalysisMar 06, 2026 A1456534
ZJ26F0332436ZJ26F0332436Certificate of AnalysisMar 06, 2026 A1456534
ZJ26F0332437ZJ26F0332437Certificate of AnalysisMar 06, 2026 A1456534
FAQ et articles
Calculateurs de solution
Avis

Avis des clients

Foire aux questions

What does Suitable for Immunofluorescence(IF) mean?
Suitable for Immunofluorescence(IF) indicates the product has been validated for use in immunoassays such as ELISA, IF, IHC and flow cytometry. Validation may include positive/negative control samples, signal-to-noise testing, and protocol-specific QC. Lot-specific test data is published on the Certificate of Analysis where available.
What does BioReagent mean?
BioReagent indicates that the product has been processed and tested for biological and biochemical applications. Specifications may include endotoxin limits, microbial controls, sterility, low DNase/RNase/protease activity, and verified biological activity where relevant.
How should this product be stored?
Store at 2–8 °C, protected from light. The material is light-sensitive — keep it in its original opaque or amber container.
How is this product shipped?
This product ships chilled on wet ice. Unpack on arrival and transfer it to the storage condition stated above.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Souhaitez-vous que nous vous envoyions un message lorsque des réductions seront disponibles?

Me rappeler plus tard

Merci ! Veuillez vérifier votre boîte de réception e-mail pour confirmer.

Oups ! Les notifications sont désactivées.