Vue d’ensemble

Etching readily controlled with minimum undercutting. Room temperature operated. Cyanide-free for standard applications. Etch rate of 28 angstrom/sec @ 25 °C. Gold etchant is a combination of potassium iodide and iodine as complexing agents synthesized by electrochemically oxidizing gold.


Application

Gold etchant is a selective general-purpose etchant for gold, compatible with negative and positive photoresists. It is used to etch out gold (Au) electrodes prior to scanning electron microscopy (SEM) imaging for morphological study and metal layer for the preparation of nanoelectrodes array. Gold etchant can also be used in metal assisted chemical etching (MACE) for the fabrication of p-n junction silicon nanopillar based solar cells.

Spécifications

Synonymes
Potassium monoiodide, Antistrumin
Conditions de stockage de stockage
Protected from light,Room temperature
Expédié en
Normal

Données avancées

Certificats (CoA, COO, BSE/TSE et tableau d'analyse)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

16 results found

Lot NumberCertificate TypeDateArticle
K2606192K2606192Certificate of AnalysisAug 12, 2026 G433796
K2606255K2606255Certificate of AnalysisAug 12, 2026 G433796
G2620147G2620147Certificate of AnalysisJun 17, 2026 G433796
G2620149G2620149Certificate of AnalysisJun 17, 2026 G433796
F2602012F2602012Certificate of AnalysisAug 07, 2025 G433796
I2516627I2516627Certificate of AnalysisAug 07, 2025 G433796
I2516628I2516628Certificate of AnalysisAug 07, 2025 G433796
B2520012B2520012Certificate of AnalysisSep 09, 2024 G433796
I2420548I2420548Certificate of AnalysisSep 09, 2024 G433796
I2420549I2420549Certificate of AnalysisSep 09, 2024 G433796
D2418487D2418487Certificate of AnalysisApr 09, 2024 G433796
D2418491D2418491Certificate of AnalysisApr 09, 2024 G433796
D2418496D2418496Certificate of AnalysisApr 09, 2024 G433796
D2418498D2418498Certificate of AnalysisApr 09, 2024 G433796
A2409029A2409029Certificate of AnalysisMay 05, 2023 G433796
F2308528F2308528Certificate of AnalysisMay 05, 2023 G433796
Propriétés chimiques et physiques
SolubilitéH2O: miscible
SensibilitéLight sensitive
Sécurité et dangers (GHS)
Pictogramme(s)
GHS07,   GHS08,   GHS09
Signal
Danger
Mentions de danger

H302:Harmful if swallowed

H303:May be harmful if swallowed

H372:Causes damage to organs through prolonged or repeated exposure

Conseils de prudence

P260:Do not breathe dust/fume/gas/mist/vapors/spray.

P261:Avoid breathing dust/fume/gas/mist/vapors/spray.

P264:Wash hands [and …] thoroughly after handling.

P270:Do not eat, drink or smoke when using this product.

P271:Use only outdoors or in a well-ventilated area.

P272:Contaminated work clothing should not be allowed out of the workplace.

P273:Avoid release to the environment.

P280:Wear protective gloves/protective clothing/eye protection/face protection.

P284:[In case of inadequate ventilation] Wear respiratory protection.

P312:Call a POISON CENTER or doctor/... if you feel unwell.

P330:Rinse mouth.

P342:If experiencing respiratory symptoms:

P391:Collect spillage.

P301+P312:IF SWALLOWED: call a POISON CENTER/doctor/... IF you feel unwell.

P302+P352:IF ON SKIN: wash with plenty of water.

P304+P340:IF INHALED: Remove person to fresh air and keep comfortable for breathing.

P305+P351+P338:IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do - continue rinsing.

P333+P313:IF SKIN irritation or rash occurs: Get medical advice/attention.

P362+P364:Take off contaminated clothing and wash it before reuse.

P405:Store locked up.

P403+P233:Store in a well-ventilated place. Keep container tightly closed.

P501:Dispose of contents/container to an approved waste disposal plant.