QUALITÉ & PURETÉMoligand™?Moligand™ — Aladdin's line of ligands and bioactive small molecules. Use for receptor, pathway, and binding studies needing defined small-molecule tools.
This compound belongs to the class of organic compounds known as leucine and derivatives. These are compounds containing leucine or a derivative thereof resulting from reaction of leucine at the amino group or the carboxy group, or from the replacement of any hydrogen of glycine by a heteroatom.
External Descriptors
Not available
1. Djoumbou Feunang Y, Eisner R, Knox C, Chepelev L, Hastings J, Owen G, Fahy E, Steinbeck C, Subramanian S, Bolton E, Greiner R, and Wishart DS. ClassyFire: Automated Chemical Classification With A Comprehensive, Computable Taxonomy. Journal of Cheminformatics, 2016, 8:61.
Certificats (CoA, COO, BSE/TSE et tableau d'analyse)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Propriétés chimiques et physiques
Poids moléculaire
481.5
XLogP3
4.200
Hydrogen Bond Donor Count
2
Hydrogen Bond Acceptor Count
8
Rotatable Bond Count
9
Exact Mass
481.165 Da
Monoisotopic Mass
481.165 Da
Topological Polar Surface Area
107.000 Ų
Heavy Atom Count
33
Formal Charge
0
Complexity
785.000
Isotope Atom Count
0
Defined Atom Stereocenter Count
2
Undefined Atom Stereocenter Count
0
Defined Bond Stereocenter Count
0
Undefined Bond Stereocenter Count
0
The total count of all stereochemical bonds
0
Covalently-Bonded Unit Count
1
Calculateurs de solution
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Avis
Avis des clients
Application Protocols
Item-specific tested applications
Not specified for this item; refer to CoA/Spec Sheet.
General protocols for screening compounds (not item-specific)
Stock preparation: Dissolve compound in anhydrous DMSO to 10–50 mM. Vortex and, if necessary, brief sonication. Optionally clarify through a 0.2 µm PTFE filter. Record exact concentration.
Aliquoting: Dispense into low-bind tubes or 96/384-well source plates. Seal to prevent evaporation and moisture ingress. Bar-code for tracking.
Assay setup: Dilute stocks into assay buffer to achieve final DMSO ≤0.5–1% v/v. Include vehicle controls and positive/negative assay controls. Mix thoroughly (pipette or plate shaker) and briefly centrifuge to remove bubbles.
Aggregation control: Include 0.01–0.05% non-ionic surfactant when permissible. Run a detergent-based counterscreen or DLS/nephelometry check at top concentrations.
Stability check: Analyze time 0 and end-point samples by LC–MS/LC–UV to verify concentration and integrity under assay conditions.
Data integrity: Use triplicates, randomize plate layout to minimize edge effects, and include inter-plate standards for normalization.
These steps are general best practices; tailor to your specific biochemical/cell-based assay requirements.
Biological Roles
Item-specific status
No biological function, pathway annotation, or target assignment is provided for this product. Any roles are to be determined empirically in your research system.
General considerations (not item-specific; for small-molecule ligands)
Screening compounds can act as enzyme inhibitors/activators, receptor ligands, ion channel modulators, or disruptors of protein–protein interactions. Actual mechanism must be established through orthogonal assays and structure–activity relationship (SAR) studies.
Early triage includes checks for colloidal aggregation, redox cycling, PAINS motifs, and fluorescence interference to avoid artifactual readouts.
Follow-up characterization often covers: basic ADME profiling (solubility, permeability, microsomal stability, plasma protein binding), selectivity panels, and cytotoxicity windows to contextualize hits.
Documentation
Record experimental provenance (assay conditions, buffer composition, co-solvent %, plate map, controls) to ensure that any observed biological role is reproducible and attributable to the compound rather than vehicle or assay artifacts.
Research Use Only
This product is for research use only and not intended for diagnostic or therapeutic applications.
Buffer Applications
Applicability note
This product is not a buffering agent. Buffer use pertains to its deployment in biochemical or cellular assays.
General guidance for assay buffers with small-molecule ligands (not item-specific)
Common buffers: HEPES (25–50 mM, pH 7.2–7.5), PBS (1×), or Tris (25–50 mM, pH 7.4). Maintain ionic strength (e.g., 100–150 mM NaCl) to emulate physiological conditions when appropriate.
Co-solvent: Keep DMSO ≤0.5–1% v/v final to balance solubility and assay tolerance. Match vehicle across all wells.
Surfactant: 0.01–0.05% Tween-20 or 0.01% Triton X-100 can reduce non-specific adsorption and aggregation in enzyme or binding assays.
Metal sensitivity: If the target or compound is metal-reactive, use chelator-free buffers (avoid EDTA) or, conversely, include Mg2+/Mn2+ as needed for enzyme activity; verify per target.
Filtration: Filter buffers (0.2 µm) and degas when performing kinetic or optical assays to minimize noise.
Recipes (general examples, not item-specific)
HEPES assay buffer: 25 mM HEPES, 150 mM NaCl, 0.01% Tween-20, pH 7.4 at 25°C.
PBS + surfactant: 1× PBS with 0.01% Tween-20.
Always confirm that buffer components do not chemically react with the compound (e.g., nucleophiles, oxidants) and that pH does not induce precipitation.
Green Alternatives
Context
Specific environmental metrics (E-factor, solvent class, hazard rank) for this SKU are Not specified for this item; refer to CoA/Spec Sheet and SDS.
General greener-practice considerations for screening compounds (not item-specific)
Prefer DMSO as a primary stock solvent when compatible; it has a favorable safety/green profile relative to dipolar aprotics like DMF/NMP in many contexts.
Minimize solvent volumes via microtiter formats (96/384/1536-well) and acoustic dispensing to reduce waste.
Use aqueous assay buffers with ≤0.5–1% co-solvent when feasible to lower organic solvent usage.
Consolidate stability and solubility scouting to a small Design of Experiments (DoE) matrix to reduce iterative solvent consumption.
Trade-offs to consider
While greener alcohols (ethanol, isopropanol) can replace acetonitrile or DMF in some preparative steps, they may limit solubility for hydrophobic compounds and can alter assay baselines.
DMSO is hygroscopic; water uptake can influence concentration over time. Use sealed storage and periodic titer checks to maintain accuracy.
Waste management
Segregate halogenated vs non-halogenated waste if applicable; label all containers with compound ID and solvent. Employ solvent recovery where institutional programs exist.
Pharmaceutical Uses
Item-specific status
No pharmacopeial status, excipient role, or formulation specification is provided for this SKU. It is supplied for research use only.
General context (not item-specific)
Compounds in ligand/screening libraries are commonly used in early discovery as reference materials, tool compounds, or preliminary hits for SAR exploration. Any transition toward development typically involves resynthesis, impurity control, salt/solid-form selection, and comprehensive CMC characterization.
If used as an analytical reference standard, verify identity and purity by orthogonal methods and document traceability to a CoA.
Manufacturing/formulation caution
No information is provided to support use as an excipient or API. Do not use in human or veterinary products. No clinical claims are made or implied.
For any intended regulated use (GLP/GMP, stability programs, impurity profiling), obtain detailed specifications and agree on a quality/analytical package with Aladdin prior to procurement.
Physical Properties
Item-specific availability
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Melting/boiling point: Not specified for this item; refer to CoA/Spec Sheet.
Density: Not specified for this item; refer to CoA/Spec Sheet.
Solubility: Not specified for this item; refer to CoA/Spec Sheet.
LogP, pKa, refractive index, UV cutoff: Not specified for this item; refer to CoA/Spec Sheet.
General guidance (literature/practice for small-molecule library members; not item-specific)
Many drug-like screening compounds are handled as DMSO stock solutions (e.g., 10–50 mM) due to broad solubilizing power. If water solubility is required, co-solvent approaches (DMSO→buffer dilution) are routinely used.
Preliminary solubility scouting can be performed in: DMSO, DMF, ethanol, acetonitrile, isopropanol, and aqueous buffers with up to 1–2% DMSO. Visual clarity, nephelometry, or LC analytics can confirm solubilization.
Thermal behavior (mp/bp) and solid-state form (amorphous vs crystalline, solvate state) should be confirmed per lot if critical to your workflow (e.g., automated dispensing).
Tip for assay readiness
Before high-throughput use, verify: (a) solubility at the top assay concentration under final buffer conditions, (b) absence of light or redox sensitivity, and (c) chemical stability during assay runtime (e.g., LC–MS at 0 and end-point). Document any observed precipitation or color change.
Quality and Grades
Item-specific (from Product Data)
Grade/Purity designation: Moligand™
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
What Moligand™ implies (general description; not a specification)
Moligand™ products are positioned for small-molecule and ligand-centric research workflows (e.g., target binding, screening, and discovery). The designation emphasizes use in research, not for clinical applications.
Purity, residual solvent content, identity confirmation (NMR/LC–MS/HRMS), and water content are critical parameters for screening compounds, but exact values are lot-specific. For this SKU, all such values are Not specified for this item; refer to CoA/Spec Sheet.
Best practices for quality assurance
Request and archive the CoA/Spec Sheet for your lot, including analytical method details (e.g., HPLC conditions, detector wavelength) used to assign purity.
Upon receipt, consider in-house verification aligned with your screening QC (orthogonal LC method, HRMS match, and, if needed, 1H NMR to detect contaminants). Document any polymorph or solvate form if it affects weighing/dispensing.
If you require low UV background or trace metal specifications for specialized assays, confirm explicitly prior to purchase—these are Not specified for this item.
Research Use Note
For research use only.
Reaction and Applications
Applicability note
This SKU is part of a small-molecule/ligand collection and is typically used in screening and binding studies rather than as a synthetic reagent.
Research applications (general; not item-specific)
Biochemical target screening: assess modulation of enzymes, receptors, or protein–protein interactions using HTS/biochemical assays.
Biophysical binding: characterize direct interactions using SPR, MST, DSF/thermal shift, NMR (WaterLOGSY, STD), or ITC.
Cellular assays: evaluate phenotypic responses, reporter activity, or pathway modulation with appropriate controls and DMSO-matched vehicles.
Computational workflows: the provided CID can facilitate database cross-references for docking or similarity searches; always confirm structure identity against your lot documentation before reliance.
Practical tips
Prepare concentrated DMSO stocks (e.g., 10–50 mM), filter if feasible (PTFE, 0.2 µm) to remove particulates, and aliquot to avoid freeze–thaw cycles.
Include aggregation and redox interference controls (e.g., detergent presence, counterscreens) to reduce false positives.
Track compound stability in assay media by LC–MS at time 0 and end-point. Light-protect if aromatic or conjugated chromophores are suspected, pending structure confirmation.
Not a synthetic reagent
If you intend to derivatize or use in chemical reactions, obtain the full structure and stability profile first; no reaction guidelines are provided for this item.
Reaction Conditions
Applicability note
No synthetic reaction conditions are provided for this product because its structure and functional groups are not disclosed in the catalog entry.
General R&D considerations (not item-specific)
For stability assessments rather than synthesis: subject a small aliquot to forced degradation panels (acidic, basic, oxidative, photolytic, thermal) and monitor by LC–UV/MS to map liabilities before assay deployment.
If conjugation or labeling is contemplated after structure disclosure, select solvents and bases/acids compatible with the revealed functionalities, and validate conditions on milligram scale before scale-up.
All reaction-centric parameters (solvent, temperature, catalysts, stoichiometry, expected yields) are inherently structure-dependent and therefore cannot be responsibly proposed here.
Safety and Handling
Item-specific hazard information
GHS Classification: Not specified for this item; refer to SDS.
Signal word / H-statements / Pictograms: Not specified for this item; refer to SDS.
General laboratory precautions (not item-specific; defer to SDS as primary source)
Handle in a chemical fume hood wearing appropriate PPE: lab coat, nitrile gloves, and splash goggles. Avoid inhalation of dust/aerosols and contact with skin or eyes.
Prevent cross-contamination in screening collections by working with clean tools and avoiding moisture ingress. Cap vials promptly after use.
Incompatibilities are structure-dependent; in the absence of details, segregate from strong oxidizers, strong acids/bases, and ignition sources. Avoid prolonged light exposure unless stability is confirmed.
First aid (general): If on skin/eyes, rinse with water for 15 minutes and remove contaminated clothing; if inhaled, move to fresh air; if ingested, rinse mouth. Seek medical attention in all exposure cases. Provide the SDS to responders.
Spill/cleanup: Collect solids or absorb solutions with inert material. Dispose according to institutional and local regulations for organic laboratory chemicals.
Waste considerations
Dispose of unused compound and DMSO/organic solvent solutions as hazardous chemical waste. Do not discharge to drains. Label with known or suspected hazards when available.
Solvent Selection
Item-specific status
Solubility and preferred solvent: Not specified for this item; refer to CoA/Spec Sheet.
General guidance for small-molecule screening compounds (not item-specific)
Primary stock solvent: DMSO is commonly used due to high solvency and assay compatibility at ≤0.5–1% v/v final.
Alternative solvents when needed: DMF, NMP, acetonitrile, ethanol, or isopropanol. For aqueous delivery, prepare a concentrated organic stock and dilute into buffer with vigorous mixing to avoid precipitation.
Buffer selection for dilution: HEPES, PBS, or assay-specific buffers at physiological ionic strength; include low non-ionic surfactant (e.g., 0.01–0.05% Tween-20) to mitigate colloidal aggregation where relevant.
Small comparison (general)
DMSO: excellent solvency; generally biocompatible ≤1% v/v; hygroscopic.
DMF/NMP: strong solvency; may interfere with some assays; handle with added care.
Acetonitrile: miscible with water; volatile; limited solubility for very lipophilic compounds.
Verify clarity after dilution at the highest test concentration. If cloudiness forms, increase dilution factor, adjust pH/ionic strength, or switch co-solvent.
For plate-based work, pre-equilibrate stocks to ambient temperature to minimize condensation; centrifuge plates briefly to settle droplets.
Storage and Reconstitution
Item-specific (from Product Data)
Recommended storage condition: Room temperature.
Shipped in: Not specified for this item; refer to CoA/Spec Sheet.
General guidance (not item-specific; complements item-specific storage)
Keep the vial tightly closed in a dry place, protected from excessive light and humidity. Use desiccant in secondary containment for library storage.
Upon first opening, promptly prepare concentrated stock solutions (e.g., 10–50 mM) in dry DMSO for assay use. Dispense single-use aliquots to minimize repeated exposure to air and moisture.
Solution storage (general practice): Store DMSO aliquots at −20 °C or −80 °C in sealed containers; avoid repeated freeze–thaw cycles. Thaw at ambient temperature and vortex before use. Verify concentration periodically due to potential DMSO water uptake.
Solid stability is compound-dependent; if long-term archival is intended, consider inert-atmosphere storage and low humidity.
All reconstitution volumes, final concentrations, and long-term stability should be validated in your lab. When available, defer to the product’s CoA/Spec Sheet and SDS for definitive, lot-specific instructions.
Structure and Identity
Item-specific (from Product Data)
SKU: L611427
Product Name: L873724
CAS No.: L611427 (catalog identifier as listed)
PubChem CID: 9913088
InChIKey: 391536 (as provided)
Grade/Purity: Moligand™
Category: Small molecules and compound libraries (小分子和化合物库)
Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
Notes on structure description
The detailed chemical structure (2D/3D), functional groups, and stereochemistry are not disclosed in the current catalog entry.
Without a provided SMILES/InChI and formula, a structural narrative (e.g., ring systems, heteroatoms, substitution pattern) cannot be reliably described for this SKU.
Practical guidance
If you require definitive identity attributes (exact formula, exact mass, stereochemistry), request the Certificate of Analysis (CoA), Spec Sheet, or structure disclosure under your screening agreement.
PubChem CID is listed for cross-referencing, but users should confirm congruence between the catalog lot and any public database record before using literature properties or computational models.
Synthetic Utility
Applicability note
This SKU is offered as a small-molecule library member for screening; it is not positioned as a synthetic intermediate, and no structural details are disclosed here.
General guidance (not item-specific)
If you intend to leverage this material synthetically (derivatization, linker installation, conjugation), first obtain the full structure, functional group map, and stability profile. Without structural disclosure, reactivity and compatibility with coupling conditions (amide formation, cross-coupling, click chemistry, etc.) cannot be predicted.
For SAR or prodrug exploration, it is customary to resynthesize the scaffold to ensure full control over regiochemistry, stereochemistry, and impurity profile, followed by parallel analog generation.
Documentation
Request spectral data (1H/13C NMR, LC–MS/HRMS, HPLC chromatogram) and any protecting group or salt form information that could influence synthetic planning. All such details are Not specified for this item; refer to CoA/Spec Sheet.
Target Specificity
Item-specific status
No target annotation, epitope, or specificity information is provided for this product.
General guidance (not item-specific)
Determine specificity empirically with primary assays and confirm with orthogonal methods. Incorporate counterscreens against related targets and measure selectivity windows. Employ concentration–response curves and kinetic analyses (where applicable) to characterize binding mode or inhibition mechanism.
For any claimed target engagement, maintain full documentation (assay protocol, controls, raw data) and confirm identity/purity of the test article from your lot.
Foire aux questions
What is Moligand??
Moligand? is one of Aladdin Scientific's premium product lines, formulated for high-purity applications across multiple workflows. Compared to standard grades in the same workflow, Moligand? products typically offer tighter specifications, more rigorous QC, and stronger lot-to-lot consistency.
How should this product be stored?
Store at room temperature.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is L611427. InChIKey VYFDSJLOCIGIKP-SFTDATJTSA-N.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
Besoin d'aide pour choisir la qualité ?
Notre guide de sélection des qualités couvre la pureté, le statut du stabilisant et l'adéquation à l'application pour toutes les variantes de notre catalogue.
Nous utilisons des cookies pour garantir le bon fonctionnement du site et, lorsque cela est autorisé, pour améliorer votre expérience. Vous pouvez gérer vos préférences à tout moment dans les Paramètres. Pour en savoir plus, consultez notre Politique relative aux cookies.
Souhaitez-vous que nous vous envoyions un message lorsque des réductions seront disponibles?
Me rappeler plus tard
Merci ! Veuillez vérifier votre boîte de réception e-mail pour confirmer.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.