LAS101057 - 10mM in DMSO , Adenosine A2b receptor antagonist, CAS No.925676-48-8, Adenosine A2b receptor antagonist

CAS: 925676-48-8 Cat. No.: L656526 Formule: C18H14FN5O Poids moléculaire: 335.34 PubChem CID: 16071896
DISPONIBLE À COMMANDE
QUALITÉ & PURETÉ 10mM in DMSO
Storage
Protected from light,Store at -80°C
Shipped In
Dry ice packs + Cold packs
★
Taille
Allemagne (EU)
USA*
Prix
Qté
1ml
L656526-1ml
Sur commande · 8–12 semaines
40,70€
Enter a quantity for the sizes you want to add.

Vue d’ensemble

LAS101057 is a potent, selective, and orally efficacious A2B receptor antagonist.

In Vivo

At 3 mg/kg, LAS101057 is active in preventing Acetyl-β-methylcholine-induced AHR, and at 10 mg/kg it inhibits AHR to Acetyl-β-methylcholine to a level virtually equal to that seen with Hexadecadrol at 1 mg/kg . MCE has not independently confirmed the accuracy of these methods. They are for reference only.

Spécifications

Spécifications et pureté
10mM in DMSO
Mécanismes biochimiques et physiologiques
LAS101057 is a potent, selective, and orally efficacious A2B receptor antagonist.
Conditions de stockage de stockage
Protected from light,Store at -80°C
Expédié en
Dry ice packs + Cold packs
Ce produit nécessite l'expédition en chaîne froide. Les services terrestres et autres services économiques ne sont pas disponibles.
Type d'action
ANTAGONIST
Mécanisme d'action
Adenosine A2b receptor antagonist
Propriétés du produit
ALogP
1
Noms et identifiants
Isomères SMILES
C1CC1C(=O)NC2=CN=C(C(=N2)C3=CN=CC=C3)C4=C(C=NC=C4)F
PubChem CID
16071896
Poids moléculaire
335.34

Données avancées

Certificats (CoA, COO, BSE/TSE et tableau d'analyse)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Calculateurs de solution
Avis

Avis des clients

Application Protocols

No item-specific, validated application protocols are provided. The following is general best-practice guidance for handling small-molecule library compounds in research assays.

General protocol (stock preparation and plating)

  1. Equilibrate vial on ice and protect from light (item-specific). Briefly centrifuge to collect contents.
  2. Prepare a concentrated DMSO stock (e.g., 10–50 mM) using an amber, low-bind microvial. Mix gently; if needed, sonicate briefly or warm to ≤40 °C.
  3. If particulates remain, consider 0.2 µm PTFE filtration (verify no adsorption losses) or adjust solvent composition.
  4. Aliquot into single-use portions to avoid freeze–thaw; store at −80 °C.
  5. Immediately before use, dilute into assay buffer to the desired concentration, keeping the final DMSO ≤ assay tolerance (commonly 0.1–1% v/v). Include vehicle controls.
  6. For plate-based assays, pre-wet tips, use low-bind plastics, and minimize dwell time to reduce adsorption and evaporation.

Integrity checks (recommended)

  • Verify identity/purity by UPLC–MS upon receipt and after extended storage.
  • Assess apparent solubility and precipitation risk in the final assay matrix (visual check, light scattering).

Note

  • These steps are general research guidance and are not product-specific validated procedures.
Biological Roles

No target, pathway, or biological function is provided for this specific item. Accordingly, no biological role can be ascribed here.

General considerations for small-molecule library members (not product-specific)

  • Library compounds may or may not have annotated targets. Initial screens often reveal hits with unknown or multi-target profiles that require follow-up validation.
  • Follow-on studies can include chemoproteomics, thermal shift assays (CETSA/DSF), genetic interaction mapping, or CRISPR knockouts to infer mechanism of action.
  • Physicochemical descriptors (pKa, logP, polar surface area), when available, can guide hypotheses about cell permeability, subcellular localization, and potential liabilities (e.g., PAINS/aggregators). Obtain these from the CoA or literature before making assumptions.

Important

  • This product is supplied strictly for research use only. It is not intended for diagnostic, therapeutic, or other clinical uses. Without item-specific data, treat it as a research chemical of unknown biological function.
Buffer Applications

This product is not a buffering reagent. Specific buffer systems are therefore not applicable.

Practical notes for assay buffers (general)

  • When introducing small-molecule stocks to biological buffers, keep co-solvent (e.g., DMSO) at assay-validated levels (often 0.1–1% v/v) and include vehicle controls.
  • Verify compound solubility and stability in the final buffer (with proteins, salts, and cofactors present). Visual inspection, nephelometry, or UPLC can detect precipitation/degradation.
  • Consider adding 0.01–0.05% nonionic surfactant (e.g., Tween-20) to reduce nonspecific adsorption and colloidal aggregation, where compatible with the assay.
  • Pre-equilibrate temperature and pH, and use low-bind plastics or silanized glass to minimize adsorption losses for lipophilic compounds.

Item-specific note

  • Because this item should be protected from light and stored at −80 °C, prepare working solutions immediately before use and minimize light exposure during buffer preparation.
Green Alternatives

Although this item is a small-molecule library member (not a bulk solvent or reagent), greener choices can be applied to its handling, dissolution, and clean-up.

Greener handling choices (general)

  • Prefer DMSO as a primary stock solvent over DMF/NMP when compatible with your assay—DMSO exhibits a more favorable EHS profile and is biodegradable.
  • For aqueous working solutions, minimize organic co-solvent to the lowest effective percentage (commonly 0.1–0.5% DMSO) to reduce emissions and waste.
  • Use microscale preparation and miniaturized assays (e.g., 384- or 1536-well) to reduce solvent consumption and waste volumes.
  • For glassware cleaning, consider water-based detergents and ethanol/isopropanol before resorting to chlorinated solvents.

Illustrative comparison (general; not product-specific)

  • DMSO vs DMF: DMSO generally has lower volatility and improved safety profile; DMF offers strong solvency but is reprotoxic and should be minimized.
  • Ethanol vs Methanol: Ethanol is typically preferred for greener profiles; methanol use should be justified by necessity.

Waste minimization

  • Consolidate compatible organic waste streams, and implement in-well quench protocols to avoid additional solvent transfers where feasible.

Caveat

  • Always balance green preferences with data quality and compound stability (this item is light-sensitive and stored at −80 °C; plan workflows to limit exposure and repeat handling).
Pharmaceutical Uses

No pharmaceutical or excipient use is assigned to this product. It is supplied for research use only and is not intended for human or veterinary applications.

Context (general, non-product-specific)

  • Small-molecule library members may be used in discovery research for hit identification and early SAR exploration but are not produced under GMP nor listed with pharmacopeial monographs unless explicitly stated on documentation.
  • If downstream development is anticipated, consider parallel procurement of GMP-grade materials or establish a route from this research-grade substance to a qualified GMP source for later stages.

Documentation

  • Pharmacopeia status, residual solvent limits, elemental impurities, and other GMP/QC attributes are not provided for this item; refer to the CoA/Spec Sheet if applicable and perform internal qualification as required by your QA system.
Physical Properties

Item-specific physicochemical properties have not been provided in this listing. Where values are not listed below, consult the CoA/Spec Sheet or authoritative databases using CAS 925676-48-8 / CID 16071896.

  • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Melting point (MP): Not specified for this item; refer to CoA/Spec Sheet.
  • Boiling point (BP): Not specified for this item; refer to CoA/Spec Sheet.
  • Density: Not specified for this item; refer to CoA/Spec Sheet.
  • Refractive index: Not specified for this item; refer to CoA/Spec Sheet.
  • Solubility profile: Not specified for this item; refer to CoA/Spec Sheet.
  • LogP / cLogP: Not specified for this item; refer to CoA/Spec Sheet.
  • pKa(s): Not specified for this item; refer to CoA/Spec Sheet.

Practical guidance (general, literature-based)

  • For small-molecule library members with unknown solubility, begin with a stock in anhydrous DMSO (e.g., 10–50 mM), then prepare assay dilutions into aqueous buffer containing 0.1–1% DMSO while monitoring for precipitation (visual check or nephelometry).
  • If DMSO solubility is inadequate, screen co-solvents (DMF, ethanol, methanol) or formulate with aqueous buffer containing co-solvent and/or 0.01–0.05% nonionic surfactant (e.g., Tween-20) where assay-compatible.
  • Determine thermal behavior and polymorphism by DSC and XRPD if solid-state properties impact handling.

Important

  • Do not treat any inferred or general values as product specifications. For release-tested values applicable to your lot, rely exclusively on the CoA.
Quality and Grades

Item-specific quality designations are not listed in this entry.

  • Grade/Purity (item-specific): Not specified for this item; refer to CoA/Spec Sheet.

Context for small-molecule library materials (general guidance)

  • Library compounds are commonly released with identity confirmation (e.g., LC–MS and/or 1H NMR) and chromatographic purity reporting (e.g., HPLC/UPLC at 214/254 nm). However, acceptance criteria and analytical methods vary; always verify with the lot-specific CoA.
  • If a stabilizer or counterion is present, it should be disclosed on the CoA. This listing provides no stabilizer information; assume none added unless stated on your documentation.
  • For screening workflows, many groups accept ≥90–95% HPLC purity for primary screens, with higher thresholds for hit confirmation and SAR. Your internal QA policy should define fit-for-purpose criteria.

Recommendations

  • Request or download the current CoA for: identity method(s), purity with chromatograms, residual solvent data, and water content (if relevant). Where necessary, perform in-house verification (orthogonal LC–MS, qNMR) prior to critical studies.
  • If UV transparency or LC baseline behavior matters (e.g., bioassays with optical readouts), ask for UV spectra to identify interfering chromophores.
Reaction and Applications

This product is cataloged within a small-molecule/compound library and is typically used as a research screening tool compound rather than as a synthetic reagent. No manufacturer application text is provided for this entry.

Common research applications (general, non-product-specific)

  • High-throughput screening (HTS) and fragment/lead discovery: Evaluate activity across biochemical or cell-based assays to identify primary hits.
  • Mechanism-of-action exploration: Use orthogonal assays to probe phenotypic effects and prioritize targets for deconvolution.
  • SAR development: If structural analogs are available, build preliminary SAR by testing related chemotypes under identical assay conditions.
  • Counter-screening: Assess selectivity by testing hits across panels to eliminate promiscuous or assay-interfering chemotypes.

Practical tips for assay use

  • Prepare DMSO master stocks (e.g., 10–50 mM), aliquot to minimize freeze–thaw cycles, and protect from light (item-specific).
  • Verify compound integrity by LC–MS/UPLC prior to critical studies; re-check after prolonged storage or multiple freeze–thaw events.
  • Monitor for aggregation/precipitation (e.g., by detergent sensitivity or light scattering) to reduce false positives in biochemical assays.
  • Include vehicle controls (matching DMSO %) and positive/negative controls to benchmark assay performance (Z’-factor, signal window).

Note

  • This section provides general research-use guidance only and does not assign any biological activity or target to this specific item.
Reaction Conditions

Not applicable in the absence of a disclosed structure and without positioning this product as a synthetic reagent. No reaction conditions can be responsibly recommended.

General advice (if used in characterization or stability studies)

  • For stability assessments, avoid prolonged exposure to light and ambient temperatures; perform analyses rapidly and store samples on ice or at subzero temperatures when not in use.
  • Use neutral, anhydrous organic solvents (e.g., acetonitrile, DMSO) for LC–MS sample preparation unless the compound is known to be unstable under those conditions.
  • For kinetic solubility or degradation studies, bracket pH (e.g., pH 2, 7, 10) and temperature (4–40 °C) to map liability, recognizing this is general methodology and not product-specific guidance.
Safety and Handling

Safety information specific to this item is limited in the listing. Always review the product SDS before use and apply a conservative approach for an uncharacterized research chemical.

Provided item-specific directives

  • Storage conditions (item-specific): Protect from light; store at −80 °C.
  • Shipping (item-specific): Shipped on dry ice packs + cold packs.

GHS and hazard statements

  • Signal word / H-Statements / GHS classification / Pictograms: Not specified for this item; refer to SDS.

General laboratory precautions (not product-specific; best practice)

  • Handle in a chemical fume hood with standard PPE: lab coat, safety glasses, and appropriate chemical-resistant gloves (e.g., nitrile). Consider double-gloving for DMSO stocks.
  • Treat as potentially harmful if inhaled, ingested, or absorbed through skin; avoid aerosolization and contact with eyes/skin.
  • Because the compound is light-sensitive (item-specific note), minimize exposure using amber vials and covered work areas.
  • Avoid repeated freeze–thaw; thaw on ice, aliquot promptly, and refreeze.
  • Keep away from incompatible materials until known (oxidizers, strong acids/bases, reactive metals), and avoid heating or nebulizing unknown organics.

First-aid overview (consult SDS for specifics)

  • Skin/eye contact: Immediately flush with water for ≥15 min; remove contaminated clothing; seek medical evaluation.
  • Inhalation: Move to fresh air; monitor breathing; obtain medical attention.
  • Ingestion: Rinse mouth; do not induce vomiting; seek medical care.

Waste disposal

  • Collect in organic hazardous waste per institutional and regulatory guidance; decontaminate surfaces with compatible solvents and detergents.
Solvent Selection

Because detailed structure is not disclosed here, select solvents using a pragmatic screening cascade suitable for diverse small molecules. None of the properties below are product specifications; they are general best practices.

Recommended workflow

  • Start with anhydrous DMSO to prepare a concentrated master stock (e.g., 10–50 mM), checking for clarity and stability.
  • If insoluble in DMSO or if assay intolerance exists, try: DMF, ethanol, methanol, or co-solvent systems (e.g., 10–30% DMSO or EtOH in aqueous buffer).
  • For aqueous delivery, limit organic co-solvent to assay-compatible levels (commonly 0.1–1% v/v DMSO; confirm tolerance for your system).

Miscibility/compatibility notes (general)

  • DMSO: miscible with water and organics; can enhance skin absorption—use gloves.
  • DMF: excellent solvent power; consider toxicity and hygroscopicity.
  • Ethanol/Methanol: good miscibility; watch enzyme compatibility and evaporation.
  • Aqueous buffers: pH can strongly influence ionizable compounds’ solubility; consider buffering strength and ionic strength.

Small comparison (general)

  • DMSO vs DMF: DMSO is typically more assay-friendly; DMF reserved for difficult solubilizations.
  • Ethanol vs Methanol: ethanol is generally more biocompatible; methanol often increases solubility but may disrupt proteins.

Tips

  • Warm gently (≤40 °C) and sonicate to aid dissolution; avoid prolonged heating or light exposure (item-specific: light-sensitive).
  • Filter 0.2 µm if particles persist and filtration is compatible with your assay and the compound’s adsorption characteristics.
Storage and Reconstitution

Item-specific storage/shipping

  • Storage conditions: Protect from light; store at −80 °C.
  • Shipped in: Dry ice packs + cold packs.

General best practices for small-molecule library compounds (not product-specific)

  • Upon receipt, keep the container cold and protected from light. Record receipt date and condition.
  • Allow vial to equilibrate on ice before opening to minimize moisture ingress and thermal shock. If supplied as a frozen solution, mix gently after thaw.
  • Prepare single-use aliquots in amber, low-bind vials to avoid repeated freeze–thaw cycles; backfill with inert gas if the compound is known (from CoA) to be air/moisture sensitive.
  • For reconstitution, choose anhydrous DMSO unless the CoA specifies otherwise. If DMSO is unsuitable, evaluate DMF, ethanol, or mixed solvent systems.
  • Label aliquots with compound ID, concentration, solvent, preparation date, and operator initials; maintain a freeze–thaw log.
  • Avoid prolonged bench-top exposure; keep on ice or in a chilled block during handling and return promptly to −80 °C.

Not provided in this listing

  • Appearance, exact form (solid vs solution), concentration (if solution), stabilizers, and any specific reconstitution instructions: Not specified for this item; refer to CoA/Spec Sheet.

Reminder

  • This product is supplied for research use only. Always defer to the lot-specific CoA and SDS for definitive instructions.
Structure and Identity

Concise identity information for professional use. Item-specific identifiers are provided; fine-grained structural descriptors are not disclosed in this listing.

  • SKU: L656526
  • Product Name: LAS101057
  • CAS: 925676-48-8
  • PubChem CID: 16071896 (literature identifier reference)
  • InChIKey: Not specified for this item; refer to CoA/Spec Sheet.
  • SMILES: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular Formula: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular Weight: Not specified for this item; refer to CoA/Spec Sheet.
  • Category Path: 全部 / 可售 / 小分子和化合物库 (Small molecules and compound libraries)

Structural description

  • Item-specific functional groups, ring systems, and stereochemistry are not disclosed here. For structural elucidation, consult the certificate of analysis (CoA), the specification sheet, or authoritative literature associated with CAS 925676-48-8 / CID 16071896.

Notes for users

  • If you require structural metadata (2D depiction, protonation state, tautomers), request the latest CoA/Spec Sheet or retrieve literature data linked to the above identifiers for computational docking, ADME prediction, or cheminformatics workflows.
Synthetic Utility

Synthetic applications cannot be detailed without a disclosed structure. This item is offered as a small-molecule library member primarily for screening, not as a defined synthetic building block in this listing.

Guidance (general)

  • If you plan to use the compound in synthesis (e.g., as a precursor or reference standard), obtain the full structural information and impurity profile from the CoA or literature (CAS 925676-48-8 / CID 16071896) and evaluate functional group compatibility, protecting group strategies, and stability.
  • Confirm identity via orthogonal methods (LC–MS, 1H/13C NMR, HRMS) before committing to multistep synthesis or analytical qualification work.
  • If analog synthesis is envisioned, construct a retrosynthetic plan once the scaffold and substituent pattern are known; assess availability of key intermediates and potential late-stage diversification handles.

Note

  • No named reactions or reactivity patterns are claimed for this item due to absent structural disclosure in the listing.
Target Specificity

No target, enzyme, receptor, or pathway specificity is provided for this product.

  • Target/Pathway: Not specified for this item; refer to CoA/Spec Sheet.
  • Species reactivity / selectivity panel: Not specified for this item; refer to CoA/Spec Sheet.

Guidance (general)

  • If used in target-based assays, include counter-screens and orthogonal readouts to rule out assay interference and off-target effects.
  • Utilize computational and experimental profiling (e.g., broad kinase panels, GPCR assays, or thermal shift arrays) to establish specificity where relevant.

Foire aux questions

How should this product be stored?
Store at ?80 °C, protected from light. The material is light-sensitive — keep it in its original opaque or amber container.
How is this product shipped?
This product ships frozen with dry ice and cold packs. Unpack on arrival and transfer it to the storage condition stated above; handle dry ice with insulated gloves in a ventilated area.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 925676-48-8, the molecular formula is C18H14FN5O, and the molecular weight is 335.34 g/mol.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Souhaitez-vous que nous vous envoyions un message lorsque des réductions seront disponibles?

Me rappeler plus tard

Merci ! Veuillez vérifier votre boîte de réception e-mail pour confirmer.

Oups ! Les notifications sont désactivées.