Mouse CD4⁺ T Cell Isolation Kit (Negative Isolation)

Cat. No.: M1522407
DISPONIBLE À COMMANDE
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
★
Size
Allemagne (EU)
USA*
Price
Qty
10T
M1522407-10T
Sur commande · 8–12 semaines
173,46€
50T
M1522407-50T
Sur commande · 8–12 semaines
763,52€
100T
M1522407-100T
Sur commande · 8–12 semaines
1 301,52€
Enter a quantity for the sizes you want to add.
🧪

Why this grade

BioReagent BioReagent for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Store at 2-8°C,Do not freeze Ships Wet ice,Do not freeze Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Vue d’ensemble

The Mouse CD4⁺ T Cell Isolation Kit (Negative Isolation) is used to isolate CD4⁺ T cells from mouse spleen or other tissue single-cell suspensions by negative i solation. The principle is to use a cocktail of biotin-labeled monoclonal antibodies against non-target cells (non-CD4⁺ T cells), followed by removal of these non-target cells using streptavidin-labeled magnetic beads, thereby achieving the isolation of mouse CD4⁺ T cells. A magnetic separator is required for the isolation process.

Applications

Isolation of CD4⁺ T cells from mouse spleen and lymph nodes.

M1522407
Component
Appearance
10T
50T
100T
Storage
M1522407A
Biotin-Antibody Mix
Liquid20 μL
100 μL
200 μL
2-8℃.
M1522407B
Streptavidin Magnetic Beads
Liquid
200 μL
1 mL
1 mL×2
2-8℃.

Protocol (Using Mouse Spleen CD4⁺ T Cell Isolation as an Example)

  1. Prepare single-cell suspension

    Grind the spleen on a 70 μm cell strainer, rinse the strainer with pre-chilled PBS, collect the cell suspension into a 50 mL centrifuge tube, and centrifuge at 500 g for 5 min.

  2. Lyse red blood cells

    After centrifugation, discard the supernatant, add 5 mL of ACK red blood cell lysis buffer, lyse at room temperature for 5 min, then add 20 mL PBS and centrifuge at 500 g for 5 min.

    Note: The red blood cell lysis step can be adjusted in volume and time depending on the lysis buffer used. A small amount of red blood cell residue will not affect subsequent isolation or cell purity.

  3. Filter and count cells

    After centrifugation, discard the supernatant, resuspend the splenocytes in PBS, filter the cell suspension through a 70 μm cell strainer, and count the cells. After counting, centrifuge at 500 g for 5 min.

    Note: The cell suspension must be passed through a cell strainer to remove tissue and cell clumps; otherwise, subsequent cell isolation purity may be affected.

  4. Adjust cell density

    After centrifugation, discard the supernatant, resuspend the cells in Isolation Buffer to a density of 1×10⁸ cells/mL.

    Note: Isolation buffer is PBS containing 2 mM EDTA and 2% fetal bovine serum (FBS), or PBS containing 2 mM EDTA and 0.5% BSA. The buffer must be pre-filtered through a 0.22 μm filter.

  5. Add Biotin-Antibody Mix

    Add 100 μL of cell suspension (1×10⁷ cells) to the bottom of a sterile FACS tube, then add 2 μL of Biotin-Antibody Mix. Mix well and incubate at 4°C for 10 min.

    Note:

    • When adding the cell suspension, add it to the bottom of the tube, avoiding the tube wall.

    • Depending on the magnetic separator used, a centrifuge tube can also be used for cell isolation.

    • If isolating more cells, increase the volume of Biotin-Antibody Mix proportionally.

  6. Add Streptavidin Magnetic Beads

    After incubation, add 20 μL of washed Streptavidin Magnetic Beads to the FACS tube (the beads must be washed before use: vortex to resuspend the beads, transfer the required volume of beads to a 1.5 mL centrifuge tube, add 1 mL of Isolation Buffer, centrifuge at 10,000 g for 1 min or use a magnetic separator for 3 min, then discard the supernatant. Add 1 mL of Isolation Buffer and wash the beads once more, then resuspend the beads in the same volume of Isolation Buffer as originally taken. For example, if 20 μL of beads are taken, resuspend them in 20 μL of Isolation Buffer after washing). Mix well and incubate at 4°C for 10 min.

    Note:

    • If isolating more cells, increase the volume of Streptavidin Magnetic Beads proportionally. For example, to isolate 5×10⁷ cells, add 10 μL of Biotin-Antibody Mix and 100 μL of Streptavidin Magnetic Beads to 500 μL of cell suspension.

    • If isolating fewer than 1×10⁷ cells, adjust the cell suspension volume to 100 μL, then add 2 μL of Biotin-Antibody Mix and 20 μL of Streptavidin Magnetic Beads.

  7. Dilute and mix

    After incubation, add 2.5 mL of Isolation Buffer to the FACS tube, and mix gently by pipetting up and down 5 times (avoid vigorous shaking or inverting).

  8. Magnetic separation

    Place the FACS tube containing the cell suspension on a magnetic separator and let stand for 5 min.

  9. Collect CD4⁺ T cells

    Gently pour the cell suspension into a sterile centrifuge tube (do not remove the FACS tube from the magnetic separator while pouring). This cell suspension contains the purified mouse CD4⁺ T cells. Centrifuge at 500 g for 5 min, then discard the supernatant and collect the cells.

  10. Resuspend for further use

    Wash the cells as required for your experiment, then resuspend them in the desired buffer or culture medium for subsequent molecular or cell biology experiments.

Isolation Performance

CD4⁺ T cells were isolated from C57BL/6 mouse splenocytes. Cells before and after isolation were stained with FITC anti-mouse CD4 antibody (clone GK1.5) and analyzed by flow cytometry. The purity of CD4⁺ T cells before and after isolation was 20.3% and 98.8%, respectively.

Precautions

  1. Avoid freezing the magnetic beads and antibody mix during use and storage.

  2. Low-retention pipette tips and centrifuge tubes are recommended to avoid loss of beads and antibodies due to adsorption.

  3. This product must be used with a magnetic separator.

  4. For research use only.

Specifications

Spécifications et pureté
BioReagent
Grade
BioReagent
Application
Cell analysis
Stockage et expédition
Conditions de stockage de stockage
Store at 2-8°C,Do not freeze
Expédié en
Wet ice,Do not freeze
Stabilité et stockage
Store at 2-8℃ long term (12 months). Do not freeze.
Contents & Storage
M1522407
Component
Appearance
10T
50T
100T
Storage
M1522407A
Biotin-Antibody Mix
Liquid20 μL
100 μL
200 μL
2-8℃.
M1522407B
Streptavidin Magnetic Beads
Liquid
200 μL
1 mL
1 mL×2
2-8℃.

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificats (CoA, COO, BSE/TSE et tableau d'analyse)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

2 results found

Lot NumberCertificate TypeDateArticle
ZJ26F0838450Certificate of AnalysisAug 19, 2026 M1522407
ZJ26F0737984Certificate of AnalysisJul 31, 2026 M1522407
FAQ et articles
Calculateurs de solution
Avis

Avis des clients

Need help choosing the grade?

Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.

View BioReagent grade guide →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.