MS Columns - BioReagent, sterile

Cat. No.: M1520097
DISPONIBLE À COMMANDE
QUALITÉ & PURETÉ BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. Sterile ? Sterile grade — processed and verified free of viable microorganisms. Use directly in aseptic procedures and cell culture without further sterilization.
Synonyms
gM Columns
Storage
Room temperature
Shipped In
Normal
Application
Cell analysis
★
Taille
Allemagne (EU)
USA*
Prix
Qté
1EA
M1520097-1EA
Sur commande · 8–12 semaines
25,95€
25EA
M1520097-25EA
Sur commande · 8–12 semaines
216,85€
Enter a quantity for the sizes you want to add.
🧪
Pourquoi cette qualité

BioReagent, sterile BioReagent,Les stériles pour les flux de travail chromatographiques et analytiques sensibles nécessitant une interférence de ligne de base minimale.

🌡

Stockage & expédition

Room temperature Expédition Normal. Consultez le COA spécifique au lot pour les spécifications exactes.

📋

Documents qualité

SDS, COA, fiche technique et fiche de spécifications disponibles au téléchargement. COA spécifique au lot accessible via la recherche par numéro de lot.

📚

Preuve documentaire

Cité dans 0 publications à comité de lecture couvrant la chromatographie, la synthèse organique et les réactions de couplage croisé.

Vue d’ensemble

Cell separation column is a specialized consumable designed for column-based cell sorting, developed specifically for the gentle isolation of cells labeled with nanomagnetic beads. Due to the extremely small size of the cell separation nanomagnetic beads (particle size: 50–100 nm), a high-intensity magnetic field is required to attract the labeled cells. The column contains an optimized matrix that, when used with a magnetic separation system, amplifies the magnetic field nearly ten-thousand-fold, enabling efficient capture and gentle elution of magnetically labeled cells. It is widely used for cell enrichment, depletion, and sorting in research and preclinical stages.


Cat. No.
Product Name
Max. Load of Labeled Cells
Max. Total Cell Load
M1520097MS Columns
1× 10⁷
2× 10⁸
L1520103LS Columns
1× 10⁸
2× 10⁹

Note: When isolating cells larger than lymphocytes, the column capacity may be reduced.



Procedure

1. Column Preparation

(1) Column installation: Insert the separation column into a suitable magnetic stand, ensuring the column wings face forward. Place a collection tube at the column outlet.

(2) Column priming: Add 500 μL of separation buffer to the column and allow it to flow through naturally.

(3) Discard flow-through: Replace the collection tube. The column is now ready.


2. Magnetic Separation

Magnetic labeling must be performed before magnetic separation. Refer to the nanomagnetic bead instructions for specific labeling methods.

(1) Cell suspension preparation: Resuspend cells in separation buffer, using 50 μL of buffer per 10⁷ cells.

Note: For higher cell numbers, increase the buffer volume accordingly.


(2) Sample loading: Apply the cell suspension to the prepared column. Collect the flow-through containing unlabeled cells.


(3) Washing: Wash the column three times with 500 μL of separation buffer. Collect the unlabeled cells that pass through and combine them with the flow-through from step (2).

Note: Once the column reservoir is empty, immediately add the same volume of buffer for the washing steps.


(4) Remove the column and place it on a new collection tube.


(5) Elution: Add 1 mL of separation buffer to the column and use the supplied plunger to quickly elute the magnetically labeled cells.

Note: (Optional) To improve the purity of magnetically labeled cells, the eluted cells can be passed through a second MS column for re-sorting.



Precautions

  1. The MS columns and matching plunger are supplied individually in sterile packaging. They are intended for single use and reuse is not recommended.

  2. Prepare the separation buffer before the experiment: PBS (pH 7.2), 0.5% BSA, and 2 mM EDTA. Mix thoroughly and store at 4 °C.

  3. Due to differences in samples and research objectives, optimal experimental conditions should be determined by the user.

  4. This product is for research use only.

  5. For your safety and health, please wear a lab coat and disposable gloves during operation.

Spécifications

Synonymes
gM Columns
Spécifications et pureté
BioReagent, sterile
Stabilité et stockage
Store at room temperature long term (24 months).
Conditions de stockage de stockage
Room temperature
Expédié en
Normal
Grade
BioReagent, Les stériles
Product Line
Produits biologiques

Documentation

📋 Fiche de données de sécurité (FDS)

Document complet couvrant les dangers, la manipulation, le stockage et la conformité réglementaire.

<<<<<<< HEAD Télécharger la SDS → ======= Télécharger la SDS → >>>>>>> release248-p3

✅ Certificat d'analyse (COA)

Données qualité spécifiques au lot. Saisissez votre numéro de lot pour récupérer le COA exact.

Rechercher le COA →

📊 Fiche technique

Résumé de référence rapide des spécifications et applications du produit.

Voir la fiche technique →

🔬 Fiche de spécifications

Attributs de qualité complets et critères d'acceptation pour cette qualité.

Voir la fiche de spécifications →

Données avancées

Certificats (CoA, COO, BSE/TSE et tableau d'analyse)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

2 results found

Lot NumberCertificate TypeDateArticle
ZJ26F0737619ZJ26F0737619Certificate of AnalysisJul 21, 2026 M1520097
ZJ26F0737620ZJ26F0737620Certificate of AnalysisJul 21, 2026 M1520097
FAQ et articles
Calculateurs de solution
Avis

Avis des clients

Besoin d'aide pour choisir la qualité ?

Notre guide de sélection des qualités couvre la pureté, le statut du stabilisant et l'adéquation à l'application pour toutes les variantes de notre catalogue.

Voir le guide des qualités BioReagent → Voir le guide des qualités Sterile →

Souhaitez-vous que nous vous envoyions un message lorsque des réductions seront disponibles?

Me rappeler plus tard

Merci ! Veuillez vérifier votre boîte de réception e-mail pour confirmer.

Oups ! Les notifications sont désactivées.