Determine the necessary mass, volume, or concentration for preparing a solution.
pour les flux de travail chromatographiques et analytiques sensibles nécessitant une interférence de ligne de base minimale.
Store at -20°C,Avoid repeated freezing and thawing Expédition Ice chest + Ice pads. Consultez le COA spécifique au lot pour les spécifications exactes.
SDS, COA, fiche technique et fiche de spécifications disponibles au téléchargement. COA spécifique au lot accessible via la recherche par numéro de lot.
Cité dans 0 publications à comité de lecture couvrant la chromatographie, la synthèse organique et les réactions de couplage croisé.
Products content

Products Introduction
The Single Cell Whole Genome Amplification Kit can be used as a template for whole genome amplification of single cells or micro samples. The total time for single-cell amplification is about 3 hours, and 2-5 μg of genomic DNA, with a size of 200-1500 bp, can be obtained after lysis, pre-amplification and amplification. The amplified product can be widely used in second-generation sequencing, large fragment copy number variation analysis, SNP typing, qPCR analysis and gene chip analysis.
Bring your own instruments and reagents
PCR instrument
Reaction tubes: low adsorption tubes recommended
Gun Heads: High quality filtered gun heads are recommended
Microcentrifuge, vortex mixer
caveat
The sensitivity of this product is very high, the experimental operation should be completed in a positive pressure ultra-clean bench or clean environment, the concentration of the amplification reaction products is high, should be well isolated to avoid aerosol contamination caused by amplification products.
Operation flow diagram

procedure
Pre-experiment preparation
Single cells were obtained by flow cytometry sorting, buffer dilution, micromanipulation and laser microdissection. It is recommended that the cells be washed prior to the experiments with a 1× PBS solution free of Mg2+ and Ca2+ , taking care to ensure that the volume of PBS solution in subsequent experiments does not exceed 2 µl.
take note of
Since the whole experiment is carried out in the same PCR tube and the reaction volume is small, the pipette tip should not touch the liquid in the tube when adding liquid, so as to avoid taking single cells or DNA out of the reaction system; when pipetting, please add the liquid along the wall of the tube carefully and do not blow the liquid in the PCR tube; before the reaction, please centrifuge briefly to make sure that the liquid in the reaction system is mixed evenly. Thaw the cell lysate, pre-amplifier and amplifier on ice before use.
cell lysis
1)Mix Cell Lysis Buffer and Cell Lysis Enzyme according to the number of reactions N, shake to mix, centrifuge briefly and set aside.

2)Mix single cells with the cell lysis mix in a PCR tube and run the following program.

2. Pre-amplification reaction
1)Mix Cell Lysis Buffer and Cell Lysis Enzyme according to the number of reactions N, shake to mix, centrifuge briefly and set aside.

2)Add 5 μl of pre-amplification mix to 10 μl of lysis reaction product from the previous step and run the following program.
3. Amplification reaction
1)Mix Amplification Buffer and Amp Enzyme Mix according to the number of reactions N, mix with shaking, centrifuge briefly and set aside.

2)Add 60 μl of amplification mix to 15 μl of pre-amplification reaction product from the previous step and run the following program.

Note: The number of cycles can be adjusted as needed, 14 cycles are recommended for single cells obtained by flow sorting, etc.
Amplification product detection
1. Agarose gel electrophoresis
5 μl of the amplified product was subjected to agarose gel electrophoresis (1% agarose gel, 110 V, 25-35 min), and the amplified product was 200-1500 bp in size.
2. Quantitative
Amplification products were subjected to magnetic bead or column purification, and purified products were quantified using Qubit with a final yield of 2-5 μg.
Document complet couvrant les dangers, la manipulation, le stockage et la conformité réglementaire.
<<<<<<< HEAD Télécharger la SDS → ======= Télécharger la SDS → >>>>>>> release248-p3Données qualité spécifiques au lot. Saisissez votre numéro de lot pour récupérer le COA exact.
Rechercher le COA →Résumé de référence rapide des spécifications et applications du produit.
Voir la fiche technique →Attributs de qualité complets et critères d'acceptation pour cette qualité.
Voir la fiche de spécifications →