Technical Articles: Reagent Chemistry, Synthesis & Bioscience Guides

CLASP1 Antibody Guide: Applications, Protocols & Validation

Recombinant Cytoplasmic linker associated protein 1/CLASP1 Antibody is a high-specificity research tool designed to detect endogenous CLASP1 protein in a range of experimental applications, enabling scientists to investigate microtubule stabilization, kinetochore-microtubule attachment, and cell division with confidence.

Product Name
Recombinant Cytoplasmic linker associated protein 1/CLASP1 Antibody
SKU
Ab380048
Target Protein
CLASP1 (Cytoplasmic linker associated protein 1)
Antibody Type
Recombinant antibody
Key Biological Role
Microtubule plus-end stabilization, kinetochore attachment, mitotic spindle regulation
Recommended Storage
Store at -20°C; avoid repeated freeze-thaw cycles

CLASP1 Target Biology and Research Significance

Recombinant Cytoplasmic linker associated protein 1/CLASP1 Antibody (Ab380048) targets CLASP1, a highly conserved member of the CLASP (Cytoplasmic Linker Associated Protein) family. CLASP1 is a microtubule plus-end tracking protein (+TIP) that plays essential roles in microtubule stabilization at the cell cortex, kinetochore-microtubule attachment during mitosis, and the regulation of mitotic spindle dynamics.

CLASP1 interacts with CLIP-170 and EB1 family members at growing microtubule ends and is recruited to kinetochores during cell division, where it promotes persistent microtubule attachment and correct chromosome segregation. Dysregulation of CLASP1 has been associated with chromosomal instability and has been reported in various cancer contexts, making it a target of interest in cell biology, oncology, and drug discovery research.

Using a validated antibody such as Ab380048 allows researchers to reliably detect endogenous CLASP1 protein levels, examine subcellular localization, and study protein-protein interactions in relevant biological models.

Sample Preparation and Protocol Optimization Tips

Optimal results with Ab380048 depend on careful sample preparation and protocol optimization. The following guidelines represent general best practices for CLASP1 detection.

Cell and Tissue Lysis: Use RIPA buffer supplemented with protease inhibitor cocktail to prevent CLASP1 degradation. Because CLASP1 interacts with microtubules, some protocols benefit from the inclusion of a microtubule-stabilizing agent (e.g., taxol) during lysis when studying microtubule-bound fractions. Centrifuge lysates at 12,000–16,000 × g for 10–15 minutes at 4°C to remove debris.

Protein Quantification: Normalize protein loading using a BCA or Bradford assay. Load 20–40 µg of total protein per lane for WB applications, though optimization may be required depending on CLASP1 expression levels in the chosen cell line.

Antigen Retrieval (for IHC on FFPE sections): Heat-induced epitope retrieval (HIER) with citrate buffer (pH 6.0) or Tris-EDTA buffer (pH 9.0) is generally recommended for paraffin-embedded tissue sections. Confirm compatibility with the specific antibody format and validate with known positive control tissue.

Antibody Dilution Titration: Always titrate Ab380048 to determine the optimal concentration for your system. Begin with the dilution range recommended in the datasheet and adjust based on signal-to-noise ratio in your specific experimental context.

Storage, Handling and Quality Assurance

Proper storage and handling of Recombinant Cytoplasmic linker associated protein 1/CLASP1 Antibody is essential to maintain antibody activity and ensure reproducible experimental results.

Storage Conditions: Store at -20°C upon receipt. For short-term use (up to 1–2 weeks), the antibody may be stored at 4°C. Avoid repeated freeze-thaw cycles, which can lead to protein aggregation and loss of binding activity. Aliquot the antibody into single-use volumes to minimize freeze-thaw events.

Formulation Considerations: Many recombinant antibodies are supplied in a stabilizing buffer containing glycerol or BSA. Do not dilute the stock solution until immediately before use. Consult the product datasheet for specific formulation details of Ab380048.

Quality Controls: As a recombinant antibody, Ab380048 offers batch-to-batch consistency advantages over conventional hybridoma-derived antibodies. Nevertheless, researchers should include a positive control (cell line or tissue known to express CLASP1) and a negative control (CLASP1 knockdown or knockout lysate where available) in each experimental run to confirm specificity.

Contamination Prevention: Use sterile technique when handling the antibody stock. Avoid introducing sodium azide into working solutions used for live-cell or in vivo applications, as azide can be cytotoxic.

Frequently asked questions

What is CLASP1 and why is it an important research target?

CLASP1 (Cytoplasmic Linker Associated Protein 1) is a microtubule plus-end stabilizing protein critical for kinetochore-microtubule attachment, mitotic spindle function, and chromosome segregation. Its dysregulation is linked to chromosomal instability and has been implicated in cancer biology, making it a relevant target for cell biology and oncology research.

Why is my CLASP1 band not visible or running at an unexpected size on western blot?

CLASP1 is a large protein of approximately 170 kDa, which can be challenging to resolve and transfer efficiently. Ensure you are using a low-percentage gel (6–8%) or gradient gel, and optimize your transfer conditions for high-molecular-weight proteins (extended transfer time or wet transfer). Additionally, confirm that your cell line expresses CLASP1 at detectable levels, and verify that sample preparation included protease inhibitors to prevent degradation.

Which fixation method is recommended for CLASP1 immunofluorescence?

Cold methanol fixation is often preferred for CLASP1 immunofluorescence because it effectively extracts soluble cytoplasmic proteins and preserves cytoskeletal structures, allowing clearer visualization of CLASP1 at microtubule plus ends and kinetochores. Paraformaldehyde (PFA) fixation followed by detergent permeabilization is also commonly used. The optimal method may vary by cell type and application, so testing both conditions is advisable.

How should I validate the specificity of Ab380048 in my experimental system?

Specificity validation should include a positive control using a cell line or tissue known to express CLASP1, alongside a negative control such as a CLASP1 siRNA knockdown or CRISPR knockout sample. Comparing the signal obtained with Ab380048 between these samples is the most reliable way to confirm on-target detection. Including an isotype control antibody at the same concentration is also recommended for immunofluorescence and immunoprecipitation experiments.

What are the advantages of using a recombinant antibody like Ab380048 compared to conventional antibodies?

Recombinant antibodies are produced using defined sequences expressed in a consistent host system, offering superior batch-to-batch reproducibility compared to hybridoma-derived monoclonal antibodies. This consistency is especially important for longitudinal studies and regulatory compliance. Recombinant antibodies can also be engineered for enhanced specificity and affinity, reducing background and improving signal quality in demanding applications.

References

  1. Akhmanova A, Hoogenraad CC, Drabek K, et al. CLASPs are CLIP-115 and -170 associating proteins involved in the regional regulation of microtubule dynamics in motile fibroblasts. Cell. 2001;104(6):923-935. doi:10.1016/S0092-8674(01)00265-4
  2. Maiato H, Fairley EA, Rieder CL, et al. Human CLASP1 is an outer kinetochore component that regulates spindle microtubule dynamics. Cell. 2003;113(7):891-904. doi:10.1016/S0092-8674(03)00465-3
  3. Mimori-Kiyosue Y, Grigoriev I, Sasaki H, et al. Mammalian CLASPs are required for mitotic spindle organization and kinetochore alignment. Genes Dev. 2006;20(13):1714-1728. doi:10.1101/gad.1437606

Products are supplied for research and development use only. Not for use in humans, animals, diagnosis, or therapy.

Categories: Technical Articles: Reagent Chemistry, Synthesis & Bioscience Guides

Products are supplied for research and development use only. Not for use in humans, animals, diagnosis, or therapy.

Cite this article

Aladdin Scientific. "CLASP1 Antibody Guide: Applications, Protocols & Validation" Aladdin Knowledge Base, updated 2026. 11. 25.. https://www.aladdinsci.com/us_ko/faqs/clasp1-antibody-applications-protocols-validation-guideline-en.html
Was this article helpful? Yes No 1 out of 1 found this helpful

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.